Product Overview The Schneider Electric NW12H1 MasterPact Circuit Breaker is a low-voltage air circuit breaker designed for power distribution protection in industrial facilities, commercial buildings, ……
Schneider NW12H1 Circuit Breaker
  • Schneider
  • NW12H1
  • Circuit Breaker
  • France
  • 439 x 441 x 395 mm
  • 90 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 3

Our advantage

Schneider NW12H1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW12H1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW12H1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW12H1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW12H1 MasterPact Circuit Breaker is a low-voltage air circuit breaker designed for power distribution protection in industrial facilities, commercial buildings, and large electrical installations. It belongs to the MasterPact NW family, which is engineered for applications requiring high-current switching, short-circuit protection, and reliable isolation of electrical distribution systems.

With a rated current of 1250 A, the NW12H1 is intended for use in main distribution boards, switchgear assemblies, and high-capacity feeder circuits. Its H1 performance classification provides a rated ultimate short-circuit breaking capacity of 65 kA at 440 V AC. This capability makes it suitable for electrical networks where fault current levels require substantial interruption performance.

The NW12H1 configuration described here is a three-pole, drawout-type circuit breaker frame supplied without a control unit. Its drawout construction allows the breaker to be moved between connected, test, and disconnected positions within a compatible switchgear installation. This arrangement supports inspection and maintenance procedures without requiring the entire switchgear assembly to be dismantled.

The breaker is designed for AC power distribution networks operating at 50/60 Hz, with a rated operational voltage of up to 690 V AC. It also supports isolation in accordance with the applicable IEC 60947-2 requirements.

The complete product configuration is important when purchasing or replacing this breaker. The NW12H1 designation identifies the breaker frame and performance class, but does not by itself confirm the presence of a protection trip unit, auxiliary contacts, motor mechanism, or other accessories. The required control and protection components must be verified separately.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series MasterPact NW
Model NW12H1
Product Type Air Circuit Breaker
Device Application Power Distribution Protection
Rated Current 1250 A at 40°C
Number of Poles 3P
Performance Class H1
Rated Operational Voltage Up to 690 V AC
Network Frequency 50/60 Hz
Rated Ultimate Short-Circuit Breaking Capacity (Icu) 65 kA at 440 V AC
Rated Service Short-Circuit Breaking Capacity (Ics) 65 kA at 440 V AC
Rated Short-Time Withstand Current (Icw) 65 kA for 1 second
Rated Insulation Voltage (Ui) 1000 V AC
Rated Impulse Withstand Voltage (Uimp) 12 kV
Mounting Type Drawout
Number of Poles Three
Control Unit Not included in this configuration
Control Type Push-button
Suitability for Isolation Yes
Maximum Breaking Time 25 ms
Power Dissipation 230 W
Dimensions 439 × 441 × 395 mm
Weight 90 kg
Standards IEC 60947-2

Specifications refer to the documented three-pole drawout NW12H1 frame configuration. Confirm the complete catalog reference and accessory configuration before ordering.

Function and Working Principle

The NW12H1 is designed to protect electrical distribution circuits by opening its main contacts when a qualifying fault or switching condition requires interruption. Its operation involves the mechanical switching mechanism, main current path, arc-interruption system, and compatible protection equipment.

1. Normal Current Distribution

During normal operation, the circuit breaker’s main contacts remain closed, allowing current to flow from the incoming power source to the connected distribution circuit.

The 1250 A rated-current capacity makes the NW12H1 suitable for high-current distribution applications when the surrounding electrical equipment, conductors, and protection coordination are correctly designed.

The rated current is not an instruction to operate continuously at any arbitrary current. Actual loading must account for ambient temperature, installation conditions, conductor ratings, and the applicable electrical design requirements.

2. Overload and Short-Circuit Protection

Circuit protection systems are designed to identify abnormal current conditions and disconnect affected circuits before damage develops.

The NW12H1 frame is designed to work with an appropriate protection control unit. The exact protection functions depend on the trip unit selected and installed. These may include long-time, short-time, instantaneous, and ground-fault protection, depending on the control unit configuration.

Because the described configuration is supplied without a control unit, buyers must not assume that a complete protection system is included with the breaker frame.

3. Arc Interruption

When the breaker opens under load or fault conditions, an electrical arc may form between separating contacts. The breaker’s arc-interruption system is designed to control and extinguish this arc so that current can be interrupted safely within the device’s rated operating conditions.

The H1 performance classification provides a 65 kA rated ultimate short-circuit breaking capacity at 440 V AC. The actual protection design must still consider the prospective fault current at the installation point and the system’s coordination requirements.

4. Drawout Mechanism

The drawout construction allows the breaker to be positioned within a compatible switchgear cradle.

Typical operating positions include:

  • Connected: The main circuit and required auxiliary connections are engaged for normal operation.
  • Test: The breaker is positioned for permitted control and functional checks while the main power circuit is isolated.
  • Disconnected: The breaker is separated from the main circuit connections for inspection or maintenance procedures.

The exact position indicators, interlocks, and operating sequence must follow the switchgear manufacturer’s instructions.

5. Electrical Isolation

The NW12H1 is identified as suitable for isolation under the applicable IEC 60947-2 requirements. This function supports maintenance and electrical system management when used according to the specified procedures.

Isolation does not replace lockout/tagout practices, verification of absence of voltage, or other mandatory safety measures.

Role in Industrial Power Distribution Systems

The NW12H1 is typically installed in a main low-voltage distribution assembly or a high-capacity feeder section. Its role is to provide switching and protection for important electrical circuits.

Main Distribution Board Protection

In a main distribution board, the breaker can protect a major incoming or outgoing circuit. Its current rating and breaking capacity must be coordinated with the supply transformer, busbar system, downstream feeders, and available fault current.

Industrial Switchgear Integration

The drawout design allows the breaker to be integrated into compatible switchgear assemblies. This can support maintenance planning and equipment inspection while keeping the overall switchgear arrangement organized.

Compatibility depends on the correct cradle, mechanical dimensions, primary connections, auxiliary wiring, and interlocking arrangement.

Power System Selectivity

The NW12H1 belongs to Category B equipment, supporting short-time withstand coordination in appropriately engineered protection systems.

Protection selectivity is achieved by coordinating the settings and characteristics of upstream and downstream protective devices. The breaker frame alone does not establish selectivity; the selected trip unit and the complete protection study are essential.

Electrical System Monitoring

When equipped with compatible control and monitoring accessories, a MasterPact installation may provide operating information to a power-management or building-management system.

The exact monitoring capability depends on the selected control unit, communication accessories, and switchgear design. These functions should not be assumed to be included with the basic breaker frame.

Industrial Applications

The NW12H1 is intended for high-current low-voltage distribution applications where reliable switching and fault interruption are required.

1. Industrial Main Switchboards

Large manufacturing facilities use main switchboards to distribute electrical power to production lines, machinery, HVAC systems, and auxiliary services.

A 1250 A breaker frame can be used in a suitable main or feeder circuit where the electrical design requires this current rating and breaking performance.

2. Power Distribution Panels

Industrial distribution panels divide incoming power among multiple downstream circuits. The NW12H1 can serve as a major feeder protective device when its rated voltage, current, and fault-interruption capability match the system requirements.

3. Transformer Secondary Protection

The breaker may be considered for a transformer secondary distribution arrangement. Selection must account for transformer capacity, impedance, available short-circuit current, conductor sizing, and coordination with upstream protection.

4. Data Centers and Critical Facilities

Data centers and other critical facilities require carefully coordinated power distribution systems. High-capacity circuit breakers can form part of switchboards supplying UPS systems, cooling equipment, and other essential loads.

The complete protection and redundancy architecture must be designed around the facility’s electrical requirements. The NW12H1 alone does not provide a complete redundant power system.

5. Commercial and Infrastructure Buildings

Large commercial buildings, infrastructure installations, and utility-related facilities may use high-current air circuit breakers in main distribution assemblies.

The breaker must be selected according to the applicable electrical standards, fault levels, load profiles, and maintenance requirements.

Installation and System Integration

The NW12H1 is a large, heavy electrical component. Installation should be performed by qualified personnel using the manufacturer’s instructions and the approved switchgear design.

1. Verify the Complete Model Configuration

Before installation, check the model designation, pole count, rated current, H1 breaking capacity, mounting type, and control-unit configuration.

The configuration described here is three-pole and drawout, without a control unit. If the project requires integrated electronic protection, the appropriate compatible control unit must be selected separately.

2. Check Switchgear Compatibility

Confirm that the switchgear cradle is designed for the specific MasterPact NW frame and configuration.

Important checks include:

  • Breaker frame and mounting dimensions.
  • Drawout cradle compatibility.
  • Primary connection arrangement.
  • Busbar and terminal clearances.
  • Mechanical and electrical interlocks.
  • Auxiliary connection requirements.
  • Connected, test, and disconnected position operation.

A breaker that shares the NW12H1 designation may still differ in mounting arrangement or accessory configuration.

3. Mechanical Handling

The supplied product weight is 90 kg. Use suitable lifting equipment and approved handling procedures when moving or installing the breaker.

Do not lift the breaker by operating handles, terminals, auxiliary components, or other parts that are not designed for lifting. Follow the manufacturer’s lifting instructions and ensure that the installation area can safely support the equipment.

4. Electrical Connections

Inspect the primary terminals, connection surfaces, and switchgear busbars before installation. Confirm that all connections are clean, correctly aligned, and tightened to the manufacturer’s specified torque values.

Use conductors and connection hardware suitable for the installation’s current and temperature requirements.

5. Protection Unit Configuration

Since the specified configuration does not include a control unit, confirm the intended protection functions and select the compatible trip unit before commissioning.

Protection settings should be based on the electrical system study, including load current, transformer characteristics, conductor protection, available fault current, and downstream device coordination.

6. Functional Testing

Before energizing the equipment, verify the mechanical operation, position indicators, interlocks, auxiliary circuits, and protection-unit installation.

Carry out the required commissioning tests according to the manufacturer’s procedures and applicable electrical standards. Record the protection settings and test results for future maintenance.

Compatible System Components

The NW12H1 is part of a larger switchgear system. Its successful operation depends on compatible mechanical, electrical, and protection components.

Component Function Compatibility Considerations
MasterPact NW drawout cradle Supports the breaker and provides its connection positions Must match the breaker frame and mounting configuration
Compatible trip unit Provides electronic protection functions Not included in the specified configuration; verify compatibility
Auxiliary contacts Provide breaker status signals Confirm contact arrangement and accessory requirements
Undervoltage release Supports specified undervoltage tripping functions Optional configuration; verify control voltage
Shunt trip release Allows remote electrical tripping Select according to the required control voltage and accessory system
Motor mechanism Supports electrical operation where required Check whether included or required by the application
Switchgear busbars Carry current to and from the breaker Confirm current rating, connection arrangement, and thermal design
Power monitoring system Collects electrical and operating information Requires compatible monitoring and communication accessories
Control power supply Supplies compatible control circuits Verify voltage, current capacity, and circuit protection

These components are not necessarily included with the breaker. Confirm the bill of materials and accessory list before purchasing.

Alternative Models and Replacement Considerations

When replacing an NW12H1, selecting another 1250 A breaker is not sufficient by itself. The replacement must match the electrical performance, mechanical arrangement, protection functions, and switchgear interface.

Alternative or Related Model Selection Considerations
MasterPact NW12H1 fixed version Same general frame and performance class, but the fixed mounting arrangement is different from the drawout version
MasterPact NW12H2 Higher H2 performance class; verify system coordination and switchgear compatibility
MasterPact NW12N1 Different short-circuit performance class; only suitable where the system fault level permits
Newer MasterPact NW generation May offer a replacement path, but dimensions, cradle, trip unit, and accessories must be checked
MasterPact MTZ family A newer product family that may be considered for an upgrade, subject to engineering review

Before selecting a replacement, compare:

  • Rated operational voltage.
  • Rated current and temperature conditions.
  • Icu, Ics, and Icw ratings.
  • Number of poles.
  • Fixed or drawout mounting.
  • Cradle and primary connection compatibility.
  • Trip unit and protection functions.
  • Auxiliary contacts and control accessories.
  • Mechanical and electrical interlocks.
  • Panel dimensions and busbar arrangements.

A replacement should be approved only after the switchgear and protection design have been reviewed.

Key Advantages

High-Current Distribution Capability

The 1250 A rated-current capacity makes the NW12H1 suitable for appropriately designed high-current distribution circuits.

65 kA H1 Breaking Performance

Its H1 performance classification provides a 65 kA rated ultimate short-circuit breaking capacity at 440 V AC, supporting applications with substantial prospective fault currents.

Drawout Construction

The drawout arrangement allows the breaker to be positioned within a compatible cradle, supporting inspection and maintenance procedures.

Isolation Suitability

The breaker is suitable for isolation under the applicable IEC 60947-2 requirements when installed and operated according to the manufacturer’s instructions.

Category B Selectivity Support

The Category B classification supports protection coordination strategies that use short-time withstand capability and suitable trip-unit settings.

MasterPact NW System Integration

The NW12H1 belongs to an established low-voltage switchgear family, allowing it to be integrated with compatible MasterPact NW cradles and accessories.

Technical FAQs

1. What is the Schneider Electric NW12H1?

The NW12H1 is a MasterPact NW low-voltage air circuit breaker frame designed for power distribution protection. The configuration discussed here is a 1250 A, three-pole, H1, drawout-type version.

2. What is the rated current of the NW12H1?

Its rated current is 1250 A at 40°C. Actual operating conditions must also account for the switchgear design, conductor ratings, ambient temperature, and applicable derating requirements.

3. What does H1 mean?

H1 identifies the breaker’s performance class. For this model, the rated ultimate short-circuit breaking capacity is 65 kA at 440 V AC.

4. What is the rated operational voltage?

The documented NW12H1 configuration has a rated operational voltage of up to 690 V AC at 50/60 Hz. Always confirm the complete product documentation for the exact configuration.

5. Is the NW12H1 a three-pole breaker?

The configuration described here is three-pole. Other NW12H1 variants may have different pole counts, so the complete reference must be checked before ordering.

6. Does this version include a trip unit?

No. The documented three-pole drawout configuration is supplied without a control unit. A compatible protection unit must be selected separately if electronic protection functions are required.

7. What is the difference between a fixed and drawout circuit breaker?

A fixed breaker is mounted directly into the switchgear assembly. A drawout breaker is installed in a compatible cradle and can be moved between specified operating positions. The two arrangements have different mechanical and connection requirements.

8. Can the NW12H1 be used at 690 V AC?

Its rated operational voltage is specified up to 690 V AC. The applicable breaking-capacity rating and complete installation conditions must be checked at the actual system voltage.

9. What should be checked before purchasing a replacement?

Verify the full catalog reference, pole count, rated current, H1 performance, mounting type, trip-unit arrangement, cradle, terminals, and accessories. Also confirm the condition and test history of used equipment.

10. What are the dimensions and weight of the NW12H1?

The supplied dimensions are 439 × 441 × 395 mm, and the weight is 90 kg. These values match the documented three-pole drawout configuration. Confirm the actual product and packaging details before shipping or installation planning.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric NW12H1, begin by identifying the complete configuration required by the existing switchgear. The NW12H1 designation alone does not establish whether the unit is fixed or drawout, three-pole or four-pole, or supplied with a protection control unit.

For replacement projects, compare the product nameplate and original equipment documentation. Confirm the rated current, voltage, breaking capacity, pole count, mounting arrangement, trip-unit requirements, and accessory configuration.

For used or refurbished circuit breakers, inspect the main contacts, arc chambers, operating mechanism, drawout contacts, position indicators, and auxiliary components. Request available inspection and functional test records, and confirm the condition of the compatible cradle where applicable.

Maintenance should follow the manufacturer’s recommended inspection intervals and procedures. Particular attention should be given to contact condition, mechanical operation, terminal connections, interlocks, insulation condition, and trip-unit testing.

Because the breaker weighs approximately 90 kg, transportation and installation require appropriate lifting equipment and qualified personnel. Keep the breaker in a clean, dry, and suitable storage environment before installation.

Conclusion

The Schneider Electric NW12H1 MasterPact Circuit Breaker is a 1250 A, three-pole, H1 air circuit breaker designed for high-current low-voltage power distribution systems. With a 65 kA rated ultimate short-circuit breaking capacity at 440 V AC, a drawout mounting arrangement, and isolation suitability, it is intended for demanding industrial and commercial switchgear applications.

The configuration described in this article is supplied without a control unit. Buyers should therefore verify the required trip unit, cradle, accessories, and complete catalog reference before ordering. Accurate configuration matching is essential for safe installation, reliable protection, and long-term switchgear maintenance.