Product Overview The Schneider Electric NW10H1 MasterPact NW Circuit Breaker is a low-voltage air circuit breaker designed for high-current power distribution systems. It belongs to the MasterPact NW fa……
Schneider NW10H1 Circuit Breaker
  • Schneider
  • NW10H1
  • Circuit Breaker
  • France
  • 439 x 441 x 395 mm
  • 90 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 3

Our advantage

Schneider NW10H1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW10H1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW10H1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW10H1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW10H1 MasterPact NW Circuit Breaker is a low-voltage air circuit breaker designed for high-current power distribution systems. It belongs to the MasterPact NW family and is used to protect electrical installations against overloads and short-circuit conditions while providing switching and isolation functions.

The NW10H1 has a 1000 A frame rating and an H1 breaking-capacity classification. Its rated ultimate short-circuit breaking capacity is 65 kA at 440 V AC. This makes it suitable for appropriately engineered distribution systems in industrial plants, commercial facilities, and large electrical installations where dependable protection and controlled power distribution are essential.

The configuration associated with the supplied dimensions and weight corresponds to a three-pole, drawout-type basic circuit breaker frame without a control unit. This distinction is important because MasterPact NW10H1 products are available in different configurations, including fixed and drawout mounting arrangements, different pole counts, and versions with or without trip units.

As a drawout circuit breaker, the unit can be withdrawn from its chassis for inspection, testing, and maintenance without requiring the entire switchgear assembly to be dismantled. The drawout arrangement is particularly useful in installations where maintenance access and equipment availability are important.

The NW10H1 is designed for integration into low-voltage switchboards and power distribution systems. Its application requires appropriate selection of the trip unit, current sensor rating, accessories, chassis, and electrical connections according to the protection design.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family MasterPact NW
Model NW10H1
Product Type Air Circuit Breaker
Device Application Power Distribution Protection
Frame Current Rating 1000 A
Breaking Capacity Class H1
Rated Ultimate Breaking Capacity (Icu) 65 kA at 440 V AC
Rated Operational Voltage Up to 690 V AC
Rated Insulation Voltage (Ui) 1000 V AC
Rated Impulse Withstand Voltage (Uimp) 12 kV
Frequency 50/60 Hz
Pole Configuration 3P for the referenced configuration
Mounting Type Drawout
Control Unit Not included in the referenced basic-frame configuration
Utilization Category Category B
Suitability for Isolation Yes, subject to applicable IEC requirements
Dimensions Provided 439 × 441 × 395 mm
Weight Provided 90 kg
Protection Standard IEC 60947-2
Typical Application Industrial and commercial low-voltage distribution

The dimensions and weight correspond to the referenced three-pole drawout configuration. Confirm the complete order number and actual accessories before purchasing.

Function and Working Principle

The MasterPact NW10H1 is designed to control and protect high-current electrical distribution circuits. It provides a switching mechanism and a protective interruption function within a low-voltage power distribution system.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating level for an extended period. If not properly controlled, excessive current can cause conductors and electrical equipment to overheat.

In a complete MasterPact installation, the compatible trip unit monitors electrical conditions and initiates circuit interruption when configured protection thresholds are exceeded.

The basic frame itself should not be confused with a complete protective assembly. The appropriate control and trip unit must be selected and installed for the intended protection functions.

2. Short-Circuit Protection

Short circuits can produce extremely high fault currents. The NW10H1 H1 performance class provides a rated ultimate short-circuit breaking capacity of 65 kA at 440 V AC.

When the installed protection system detects a qualifying fault, the circuit breaker opens its contacts to interrupt the current. Correct selection requires checking the prospective fault current at the installation point and confirming that the breaker rating is adequate for the electrical system.

3. Switching and Isolation

The circuit breaker supports controlled switching of electrical distribution circuits. It can be used to connect or disconnect feeders and other power distribution sections.

The MasterPact NW range is suitable for isolation in accordance with applicable IEC requirements. Isolation procedures must still follow the installation’s electrical safety rules and approved lockout procedures.

4. Drawout Operation

The referenced configuration uses a drawout mounting arrangement. This allows the breaker to be moved between operating, test, and disconnected positions according to the compatible chassis design.

The arrangement supports maintenance activities and equipment inspection while helping reduce the work required to remove the complete switchgear assembly.

5. Protection Coordination

A properly engineered protection system coordinates the circuit breaker with upstream and downstream protective devices. This helps ensure that a fault is isolated by the appropriate protective device while limiting unnecessary interruption to other parts of the electrical network.

Protection coordination depends on the selected trip unit, current sensor, system fault level, and protective-device settings.

Role in Industrial Power Distribution Systems

The NW10H1 is generally installed in the main or distribution switchgear of a facility. It can protect incoming feeders, transformer secondary circuits, large distribution branches, and other high-current electrical circuits when correctly selected.

Main Distribution Protection

In a main low-voltage distribution board, the circuit breaker can serve as a protective switching device for an incoming or outgoing feeder. Its 1000 A frame rating provides a high-current platform for appropriately rated distribution applications.

The final current protection setting depends on the installed trip unit and current sensor configuration.

Transformer Feeder Protection

The breaker may be used on the low-voltage side of a transformer to protect downstream distribution equipment. Engineers must consider transformer capacity, rated secondary current, short-circuit impedance, and the prospective fault current.

Generator and Power Source Distribution

In suitable systems, MasterPact circuit breakers can be incorporated into generator distribution and power-source switching arrangements. The complete electrical design must account for generator characteristics, system grounding, protection coordination, and any required interlocking.

Switchgear Integration

The drawout configuration is designed for use with a compatible chassis and switchgear assembly. Correct mechanical and electrical compatibility is essential for safe installation and operation.

Industrial Applications

1. Manufacturing Facilities

Large manufacturing plants use low-voltage distribution systems to supply production machinery, motor control centers, compressors, pumps, and auxiliary equipment.

The NW10H1 can be applied to appropriately rated distribution feeders where its current and breaking-capacity specifications meet the system requirements.

2. Data Centers

Data centers require structured power distribution to support server rooms, cooling systems, UPS equipment, and auxiliary infrastructure.

A suitable MasterPact circuit breaker can form part of the facility’s low-voltage protection architecture. Its application must be coordinated with upstream protection, downstream distribution devices, and the facility’s redundancy design.

3. Commercial Buildings

Large commercial buildings may use high-current air circuit breakers in main distribution boards supplying lighting, HVAC systems, elevators, and other electrical loads.

The breaker should be selected according to the building’s calculated demand, fault level, and distribution arrangement.

4. Power Distribution Rooms

Industrial power distribution rooms often contain switchgear assemblies that require high-current switching and protective interruption.

The drawout design can simplify inspection and maintenance procedures when used with the correct chassis and operating mechanism.

5. Infrastructure and Utility Facilities

Water treatment plants, transportation facilities, industrial utilities, and other infrastructure installations may require high-capacity low-voltage circuit protection.

The NW10H1 can be considered for suitable feeder applications after evaluating system voltage, fault current, load characteristics, and protection coordination.

Installation and System Integration

Correct installation is essential for safe operation and reliable circuit protection.

1. Verify the Complete Configuration

NW10H1 is a model designation rather than a complete configuration description. Before installation, confirm:

  • Three-pole or four-pole construction.
  • Fixed or drawout mounting.
  • Basic frame or complete breaker assembly.
  • Trip unit and control-unit configuration.
  • Current sensor rating.
  • Compatible chassis and cradle.
  • Required auxiliary contacts and accessories.

The referenced 90 kg configuration is a three-pole drawout basic frame without a control unit. Do not assume that every NW10H1 product has the same dimensions or weight.

2. Check Electrical Ratings

Confirm that the installation voltage and prospective short-circuit current are within the circuit breaker’s specified ratings.

The H1 class provides 65 kA Icu at 440 V AC. The protection engineer must also check the applicable Ics and Icw ratings, system fault conditions, and coordination requirements before approving the device.

3. Verify Chassis Compatibility

A drawout circuit breaker must be installed in a compatible chassis. Check the frame size, pole arrangement, connection layout, mechanical interlocks, and electrical accessories.

Do not force a breaker into a chassis that has not been verified for the exact configuration.

4. Inspect Electrical Connections

Inspect the main terminals, busbar connections, insulation surfaces, and contact areas before commissioning.

Connection torque, conductor sizing, busbar arrangement, and phase identification must follow the manufacturer’s installation documentation and applicable electrical standards.

5. Configure the Protection System

Install and configure the appropriate trip unit and current sensors where required. Protection settings should be based on the system load, conductor capacity, equipment requirements, and coordination study.

Unverified or arbitrary protection settings can result in inadequate fault protection or unnecessary trips.

6. Perform Commissioning Tests

Before energizing the equipment, verify the mechanical operation, drawout positions, interlocks, auxiliary circuits, and protection functions.

Testing should be conducted by qualified electrical personnel using suitable procedures and instruments. Record the final settings and commissioning results for future maintenance.

Compatible System Components

The NW10H1 is part of a larger switchgear assembly. The following components may be required depending on the installation configuration.

Component Function Compatibility Considerations
MasterPact NW chassis Supports the drawout breaker Must match frame size, pole count, and mounting configuration
Trip unit Provides electronic protection functions Select according to the required protection scheme
Current sensors Provide current measurement for protection Confirm sensor rating and trip-unit compatibility
Auxiliary contacts Provide breaker status signals Verify contact type and control voltage
Closing and opening accessories Support remote or controlled operation Confirm accessory compatibility
Shunt trip Enables electrical opening commands Check coil voltage and control-circuit requirements
Undervoltage release Provides undervoltage-related tripping or control Confirm rated voltage and operating characteristics
Switchgear busbars Carry current between distribution components Verify current capacity, connection geometry, and temperature limits
PLC or power monitoring system Monitors breaker status and distribution conditions Requires suitable auxiliary contacts or compatible communication equipment

Not all components are included with the basic frame. The final bill of materials should be checked against the complete breaker configuration.

Alternative Models and Replacement Considerations

The MasterPact NW family includes different frame sizes and breaking-capacity classes. A replacement should be selected according to the electrical system and physical installation rather than model-family similarity alone.

Model or Option General Description Replacement Considerations
NW10N1 1000 A frame, N1 breaking-capacity class Lower breaking-capacity class; verify fault-level requirements
NW10H1 1000 A frame, H1 breaking-capacity class Reference model
NW10H2 1000 A frame, H2 breaking-capacity class Higher breaking-capacity class; verify system and chassis compatibility
NW12H1 1250 A frame, H1 class Different frame-current rating and installation requirements
NW08H1 800 A frame, H1 class Lower frame-current rating; not a direct substitute without engineering review

When replacing an NW10H1, check:

  • Rated operational voltage.
  • Frame and sensor current ratings.
  • Icu, Ics, and Icw values.
  • Pole count.
  • Fixed or drawout construction.
  • Trip-unit type and protection functions.
  • Chassis and cradle compatibility.
  • Terminal and busbar arrangement.
  • Auxiliary contacts and control accessories.
  • Switchgear dimensions and clearances.

A higher breaking-capacity class does not automatically make a breaker a direct replacement. Mechanical fit, trip-unit compatibility, and the complete protection design must also be verified.

Key Advantages

High-Current Distribution Capability

The 1000 A frame rating makes the NW10H1 suitable for appropriately designed high-current low-voltage distribution applications.

65 kA H1 Breaking Capacity

The H1 performance class provides a 65 kA rated ultimate short-circuit breaking capacity at 440 V AC, subject to the applicable operating conditions and product configuration.

Drawout Maintenance Arrangement

The drawout design allows the breaker to be moved from its operating position for inspection and maintenance when installed in a compatible chassis.

Industrial Switchgear Integration

The MasterPact NW family is designed for integration into low-voltage switchgear and distribution assemblies.

Isolation Capability

The range supports isolation in accordance with applicable IEC requirements, helping facilitate safe electrical maintenance procedures when used correctly.

Configurable Protection Architecture

The complete breaker assembly can be configured with suitable trip units, current sensors, and accessories to meet the protection requirements of different distribution systems.

Technical FAQs

1. What is the Schneider Electric NW10H1?

The NW10H1 is a MasterPact NW air circuit breaker model designed for high-current low-voltage power distribution. It has a 1000 A frame rating and belongs to the H1 breaking-capacity class.

2. What is the rated current of the NW10H1?

Its frame rating is 1000 A at 40°C. The actual protection current depends on the selected current sensor and trip-unit configuration.

3. What is the breaking capacity of the NW10H1?

The H1 version has a rated ultimate short-circuit breaking capacity of 65 kA at 440 V AC. The applicable rating must be checked against the system voltage and manufacturer documentation.

4. Is the NW10H1 a fixed or drawout circuit breaker?

The NW10H1 family includes different mounting configurations. The referenced 439 × 441 × 395 mm, 90 kg configuration is a three-pole drawout basic frame without a control unit.

5. Does this configuration include a trip unit?

The referenced basic-frame configuration is supplied without a control unit. A suitable protection unit and associated components must be confirmed for the complete installation.

6. What is the difference between Icu and Ics?

Icu is the rated ultimate short-circuit breaking capacity, while Ics is the rated service short-circuit breaking capacity. Both are important when evaluating a circuit breaker’s ability to interrupt faults and remain suitable for continued service.

7. Can the NW10H1 protect a transformer feeder?

It may be used in a properly engineered transformer feeder protection arrangement. The transformer rating, secondary voltage, prospective fault current, and protection coordination must be evaluated before selection.

8. What chassis is required for the drawout version?

The breaker requires a compatible MasterPact NW chassis matching its frame, pole count, and mechanical configuration. Confirm the complete order number before purchasing a replacement chassis.

9. Can an NW10H2 replace an NW10H1?

Not automatically. Although both use the NW10 frame, their breaking-capacity classes differ. Mechanical configuration, chassis compatibility, trip unit, and protection coordination must all be checked.

10. What should be inspected before purchasing a used NW10H1?

Check the nameplate, pole configuration, mounting type, contact condition, operating mechanism, drawout mechanism, insulation surfaces, trip-unit availability, and included accessories. Request suitable test records for equipment intended for critical power distribution systems.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric NW10H1, identify the complete configuration before confirming an order. The model designation alone does not specify every mechanical and electrical option.

For the referenced drawout configuration, verify that the unit is three-pole, has the correct frame arrangement, and is supplied without a control unit if that is what the application requires. Confirm whether the chassis, trip unit, current sensors, and auxiliary accessories are included separately.

For used or refurbished circuit breakers, request clear photographs of the nameplate, main contacts, operating mechanism, terminals, and drawout assembly. Check for mechanical damage, overheating, corrosion, contamination, and signs of unauthorized modification.

Maintenance should follow the manufacturer’s instructions and the facility’s electrical maintenance program. Inspection may include contact condition, mechanical operation, connection integrity, insulation condition, trip-unit testing, and verification of interlocks.

Before replacing an existing breaker, compare its complete configuration with the proposed replacement. Differences in pole count, mounting arrangement, trip-unit type, or chassis design can prevent direct installation even when both devices carry the NW10H1 model designation.

Conclusion

The Schneider Electric NW10H1 MasterPact NW Air Circuit Breaker is a high-current protection device designed for low-voltage power distribution systems. It has a 1000 A frame rating and an H1 breaking-capacity classification, with a rated ultimate short-circuit breaking capacity of 65 kA at 440 V AC.

The supplied dimensions and weight correspond to a three-pole drawout basic-frame configuration without a control unit. Correct identification of the complete configuration is essential when purchasing, installing, or replacing this equipment.

For industrial switchgear maintenance and power distribution projects, the NW10H1 provides a platform for high-current switching and protection when paired with the appropriate trip unit, chassis, sensors, and accessories.