• Schneider NT08H1 Circuit Breaker
  • Schneider NT08H1 Circuit Breaker
  • Schneider NT08H1 Circuit Breaker
  • Schneider NT08H1 Circuit Breaker
Product Overview The Schneider Electric NT08H1 MasterPact NT Circuit Breaker is a low-voltage air circuit breaker designed for power distribution protection in industrial facilities, commercial building……
Schneider NT08H1 Circuit Breaker
  • Schneider
  • NT08H1
  • Circuit Breaker
  • France
  • 322 x 288 x 277 mm
  • 30 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 3

Our advantage

Schneider NT08H1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NT08H1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NT08H1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NT08H1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NT08H1 MasterPact NT Circuit Breaker is a low-voltage air circuit breaker designed for power distribution protection in industrial facilities, commercial buildings, and large electrical installations. It belongs to the MasterPact NT product family and is intended to protect electrical systems against overloads and short-circuit faults when equipped with a suitable protection unit.

The NT08H1 is an 800 A frame-rated circuit breaker with an H1 breaking-capacity classification. Its published short-circuit breaking capacity is 42 kA at 440 V AC. The device is designed for applications where reliable switching, electrical isolation, and coordinated protection are important to the operation of a power distribution system.

The circuit breaker can be used in main distribution boards, switchboards, and industrial electrical rooms. It provides a means of connecting and disconnecting power circuits while supporting protection coordination with upstream and downstream protective devices.

The supplied product configuration corresponds to a three-pole, drawout-type basic breaker frame without a control unit. This distinction is important because the NT08H1 designation can be used across different configurations. Pole count, mounting arrangement, trip unit, chassis, and accessories must be checked against the complete order number before installation or replacement.

For maintenance and procurement projects, confirming the complete product configuration is essential. A basic breaker frame without a control unit should not be treated as a complete, ready-to-operate protected circuit breaker unless the required compatible protection and operating components are provided.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family MasterPact NT
Model NT08H1
Product Type Air Circuit Breaker
Frame Rating 800 A
Performance Classification H1
Ultimate Breaking Capacity (Icu) 42 kA at 440 V AC
Rated Operational Voltage Up to 690 V AC
Rated Frequency 50/60 Hz
Poles 3P for the referenced configuration
Mounting Type Drawout
Control Unit Not included in the referenced basic-frame configuration
Insulation Voltage (Ui) 1000 V AC
Impulse Withstand Voltage (Uimp) 12 kV
Short-Time Withstand Capability Configuration and rating dependent
Applicable Standard IEC 60947-2
Dimensions Provided 322 × 288 × 277 mm
Weight Provided 30 kg
Typical Application Low-voltage power distribution protection

Note: The dimensions and weight correspond to the supplied listing information and the referenced 3-pole drawout configuration. Confirm the exact order number, chassis, and accessories before using these values for installation or shipping.

Function and Working Principle

The NT08H1 circuit breaker is designed to control and protect electrical distribution circuits. Its operating mechanism allows the contacts to open and close, while the protection system detects electrical fault conditions and initiates circuit interruption when the required protection components are installed.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating level for an extended period. If the condition is not corrected, conductors and connected equipment may overheat.

A compatible protection unit monitors current and determines whether the overload condition requires the breaker to trip. The selected protection settings must match the electrical installation and the characteristics of the protected circuit.

2. Short-Circuit Interruption

A short circuit can produce extremely high fault current. The circuit breaker is designed to interrupt the current within its specified breaking capacity.

The NT08H1 H1 classification provides a 42 kA ultimate breaking capacity at 440 V AC. The actual suitability of the breaker depends on the prospective fault current at the installation point and the applicable voltage rating.

Engineers must ensure that the available fault current does not exceed the device’s rated interruption capability.

3. Switching and Isolation

The breaker provides switching functionality for connecting and disconnecting a power circuit. It can also be used for electrical isolation when installed and operated according to the applicable standards and procedures.

Isolation for maintenance must always follow the site’s safety procedures. Opening a circuit breaker alone does not replace lockout/tagout procedures or verification that the equipment is de-energized.

4. Drawout Operation

The referenced configuration is drawout type. A drawout breaker is installed in a compatible chassis and can be moved between defined operating positions according to the manufacturer’s instructions.

This arrangement can simplify inspection, maintenance, and replacement compared with a fixed installation. The correct chassis and mechanical interlocking arrangement are essential for safe operation.

5. Protection Coordination

The breaker forms part of a coordinated electrical protection system. Its protection settings and characteristics should be selected in relation to upstream and downstream devices.

Proper coordination helps isolate the affected circuit while reducing unnecessary interruption to other parts of the distribution network.

Role in Industrial Power Distribution Systems

The MasterPact NT08H1 can serve as a major switching and protection device in low-voltage distribution systems. It is typically installed in a main or sub-distribution switchboard where electrical loads require high-current protection.

Main Distribution Protection

In a main distribution panel, the breaker can protect a feeder supplying downstream distribution boards or industrial equipment. Its 800 A frame rating makes it suitable for installations designed around this current class, provided the selected sensor and protection settings are appropriate.

Generator and Transformer Distribution

Industrial facilities may use circuit breakers to connect and protect power sources such as transformers or generators. The NT08H1 may be considered in suitable distribution arrangements, but generator protection and source-transfer requirements must be evaluated separately.

Integration with Electrical Monitoring

A complete MasterPact installation may be equipped with compatible monitoring and control accessories. Depending on the selected protection unit and accessories, the electrical system may support measurement, status indication, alarms, and remote operation.

The basic-frame configuration described here does not include a control unit. Required monitoring and protection functions must therefore be confirmed as part of the complete equipment configuration.

Coordination with Downstream Equipment

The breaker can protect feeders supplying motor control centers, distribution panels, HVAC systems, and other industrial loads. Protection coordination should be evaluated using the electrical characteristics of all connected devices.

Industrial Applications

1. Industrial Main Switchboards

Large manufacturing plants require dependable protection for incoming supplies and major distribution feeders. The NT08H1 can be used in an appropriately rated switchboard to provide high-current circuit switching and protection.

2. Commercial Building Power Distribution

Commercial facilities such as data centers, hospitals, and large office buildings often use low-voltage distribution systems with high-current feeder circuits.

A compatible MasterPact NT configuration may be used where its electrical ratings, protection functions, and installation arrangement meet the project requirements.

3. Manufacturing Facilities

Production plants commonly distribute electrical power to multiple production lines, motor control centers, and auxiliary systems. A suitably configured air circuit breaker can protect major feeder circuits and support planned maintenance.

4. Data Center Electrical Infrastructure

Data centers depend on coordinated electrical distribution to supply servers, cooling systems, UPS equipment, and supporting infrastructure.

The NT08H1 may be used in suitable low-voltage distribution arrangements. However, critical facilities require detailed protection studies, redundancy planning, and coordination with UPS and generator systems.

5. Utility and Infrastructure Installations

Water treatment plants, transportation facilities, and other infrastructure installations use large electrical distribution systems. A high-current air circuit breaker can provide switching and protection for appropriately designed feeder circuits.

The final selection must account for environmental conditions, available fault current, system voltage, and required protection functions.

Installation and System Integration

Correct installation is essential for the safe operation of an 800 A air circuit breaker. Installation and commissioning should be performed by qualified electrical personnel using the manufacturer’s instructions.

1. Verify the Complete Configuration

Before installation, confirm the complete order number and identify the following:

  • Three-pole or four-pole arrangement.
  • Fixed or drawout mounting type.
  • Compatible chassis and cradle.
  • Rated current and sensor configuration.
  • Protection or trip unit requirements.
  • Required electrical and mechanical accessories.

The NT08H1 designation alone does not identify every configuration detail.

2. Confirm Electrical Ratings

Check the system voltage, frequency, rated current, and prospective short-circuit current. The installation’s available fault current must remain within the breaker’s applicable interruption rating.

The 800 A frame rating should not automatically be interpreted as the actual protection setting. The installed sensor and protection unit determine the available current settings and protection characteristics.

3. Prepare the Drawout Chassis

For a drawout installation, use the compatible chassis specified for the breaker. Confirm that the guide rails, mechanical interlocks, shutters, and position indicators operate correctly.

Do not force the breaker into the chassis. Mechanical resistance or misalignment should be investigated before operation.

4. Check Primary and Secondary Connections

Inspect the primary connection points, secondary wiring, grounding arrangements, and accessory connections. Ensure that all connections are correctly installed and tightened according to the manufacturer’s specified procedures.

Secondary circuits used for control, indication, or protection must be checked against the selected accessories and control unit.

5. Configure Protection Functions

The referenced basic-frame configuration is supplied without a control unit. A compatible protection unit must be selected and configured where required for the intended application.

Protection settings should be based on the system study, conductor ratings, load characteristics, and coordination requirements. Do not apply arbitrary settings based only on the breaker frame rating.

6. Commissioning and Testing

Before energizing the system, qualified personnel should verify the mechanical operation, electrical connections, protection configuration, interlocks, and auxiliary functions.

Functional testing should follow the manufacturer’s procedures and the site’s commissioning requirements. Record the final configuration and protection settings for future maintenance.

Compatible System Components

The NT08H1 is normally installed as part of a complete MasterPact NT assembly. The following components may be relevant depending on the selected configuration.

Component Function Compatibility Considerations
MasterPact NT chassis Supports a drawout breaker installation Must match the breaker frame and mounting arrangement
Compatible trip unit Provides electrical protection functions Select according to the required protection scheme
Sensor plug Establishes the applicable current rating Must match the protection unit and breaker configuration
Auxiliary contacts Provide breaker status signals Verify contact arrangement and accessory compatibility
Shunt trip Enables remote electrical tripping Confirm control voltage and accessory compatibility
Undervoltage release Trips or prevents closing under specified voltage conditions Verify voltage rating and control-circuit requirements
Closing mechanism Supports breaker closing operation Confirm the required operating arrangement
Electrical distribution busbars Carry power to and from the breaker Check current rating, connection dimensions, and temperature limits
Switchboard enclosure Houses the breaker and associated equipment Confirm dimensions, clearances, and heat dissipation

The table describes typical system components, not a statement that these accessories are included with the supplied breaker frame.

Alternative Models and Replacement Considerations

When replacing an NT08H1, the complete configuration must be reviewed. A breaker with the same frame rating may differ in breaking capacity, mounting type, pole count, protection unit, and accessories.

Alternative or Related Model Considerations
MasterPact NT08H2 Related NT08 frame with a different breaking-capacity classification
MasterPact NT08L1 Higher breaking-capacity class; requires application-specific verification
MasterPact NT10H1 Higher frame rating; not automatically interchangeable
MasterPact NW08H1 Related MasterPact family with different frame and physical configuration
Schneider Electric LV947120 A newer replacement reference associated with certain NT08H1 configurations; verify exact application and configuration

Before selecting a replacement, compare:

  • Rated operational voltage.
  • Frame current and sensor rating.
  • Ultimate and service breaking capacities.
  • Pole count.
  • Fixed or drawout mounting arrangement.
  • Trip unit and protection functions.
  • Chassis and connection dimensions.
  • Auxiliary contacts and operating accessories.
  • Switchboard space and installation requirements.

A newer breaker may require changes to the chassis, busbar connections, control wiring, and protection coordination. Replacement should be treated as an engineering task rather than a simple physical substitution.

Key Advantages

High-Current Distribution Capability

The 800 A frame rating supports use in suitably designed low-voltage distribution systems with substantial feeder loads.

H1 Breaking-Capacity Classification

The H1 performance classification provides a specified 42 kA ultimate breaking capacity at 440 V AC, subject to the applicable ratings and configuration.

Drawout Maintenance Arrangement

The referenced drawout configuration can simplify inspection and replacement when used with the correct chassis and operating procedures.

Industrial Power Distribution Design

The MasterPact NT family is designed for large-scale low-voltage distribution applications where dependable switching and protection are required.

Expandable Configuration

Compatible protection units and accessories can be selected to meet the monitoring, control, and protection requirements of the installation.

Standard-Based Protection

The product family is designed around IEC 60947-2 requirements. The complete installed assembly must still be selected, installed, and tested according to the applicable standards.

Technical FAQs

1. What is the Schneider Electric NT08H1?

The NT08H1 is a MasterPact NT air circuit breaker with an 800 A frame rating and H1 breaking-capacity classification. It is used in low-voltage power distribution systems.

2. What is the rated current of the NT08H1?

The frame rating is 800 A. The actual current-sensing and protection configuration depends on the selected sensor and compatible protection unit.

3. What is its breaking capacity?

The H1 version has a published ultimate breaking capacity of 42 kA at 440 V AC. The applicable rating must be checked against the installation voltage and fault level.

4. Is the NT08H1 suitable for 690 V AC systems?

The product documentation identifies a rated operational voltage up to 690 V AC. The corresponding interruption rating and system conditions must be verified before application.

5. Does this configuration include a trip unit?

The referenced three-pole drawout basic-frame configuration is specified without a control unit. A compatible protection unit must be selected where required.

6. What is the difference between a fixed and drawout circuit breaker?

A fixed breaker is mounted directly in its installation position. A drawout breaker is installed in a compatible chassis and can be moved between defined positions for operation, isolation, and maintenance.

7. Can the NT08H1 be used as a main circuit breaker?

It may be used as a main breaker when its voltage, current, breaking capacity, protection configuration, and installation arrangement meet the electrical design requirements.

8. What chassis is required?

The drawout breaker must be paired with the compatible MasterPact NT chassis specified for the exact configuration. The chassis must be verified separately when ordering replacement equipment.

9. What should be checked before purchasing a replacement?

Confirm the complete reference number, pole count, mounting type, protection unit, sensor rating, chassis compatibility, accessories, and physical dimensions. Also verify the breaker’s condition and test history.

10. Are the supplied dimensions and weight correct?

The supplied dimensions of 322 × 288 × 277 mm and weight of 30 kg correspond to the referenced three-pole drawout basic-frame configuration. Other NT08H1 configurations, including four-pole or different mounting versions, may have different dimensions and weights.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric NT08H1, verify the full reference number rather than relying only on the NT08H1 model designation. Confirm whether the requested item is a basic breaker frame or a complete assembly with the required protection and operating components.

For replacement projects, compare the existing breaker’s pole count, chassis, sensor rating, trip unit, auxiliary accessories, and connection arrangement. A basic frame supplied without a control unit may require additional components before it can perform the intended protection function.

For used or refurbished equipment, request clear photographs of the nameplate, front panel, primary contacts, and mechanical interfaces. Confirm the operating condition, maintenance history, and availability of suitable test documentation.

During routine maintenance, inspect the breaker mechanism, contact condition, electrical connections, chassis alignment, and accessory wiring according to the manufacturer’s maintenance procedures. Any testing, adjustment, or repair involving high-current switching equipment should be performed by qualified personnel.

Conclusion

The Schneider Electric NT08H1 MasterPact NT Circuit Breaker is an 800 A low-voltage air circuit breaker with an H1 breaking-capacity classification of 42 kA at 440 V AC. The referenced three-pole drawout configuration is supplied without a control unit and is intended for integration into a compatible electrical distribution assembly.

Its drawout arrangement and high-current distribution capability make it relevant to industrial switchboards, commercial power systems, and infrastructure installations. For procurement and replacement, verifying the complete order number, protection configuration, chassis, and accessories is essential to ensure safe and technically appropriate integration.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501