• Schneider LC1F150R7 Contactor
  • Schneider LC1F150R7 Contactor
  • Schneider LC1F150R7 Contactor
  • Schneider LC1F150R7 Contactor
Product Overview The Schneider Electric LC1F150R7 TeSys F Contactor is a three-pole industrial switching device designed for controlling electric motors and resistive loads in low-voltage power distribu……
Schneider LC1F150R7 Contactor
  • Schneider
  • LC1F150R7
  • Contactor
  • France
  • 170 x 163.5 x 171 mm
  • 3.43 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 1

Our advantage

Schneider LC1F150R7 Contactor

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider LC1F150R7 Contactor

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider LC1F150R7 Contactor

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider LC1F150R7 Contactor

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric LC1F150R7 TeSys F Contactor is a three-pole industrial switching device designed for controlling electric motors and resistive loads in low-voltage power distribution and automation systems. It belongs to the TeSys F contactor range, which is designed for industrial applications requiring reliable switching of high-current electrical loads.

The LC1F150R7 features three normally open main contacts and an AC-3 rated operational current of 150 A at operating voltages up to 440 V AC. Its AC-1 thermal current rating is 250 A under the specified temperature conditions. The R7 coil designation identifies a 440 V AC control coil, an important specification when matching the contactor to an existing control circuit.

In an industrial motor-control system, a contactor provides an electrically operated method of connecting and disconnecting the motor from its power supply. It receives a control signal through its coil circuit and operates its main contacts accordingly. This allows a PLC, relay-control circuit, or other automation equipment to coordinate motor operation without directly switching the full motor load through low-power control devices.

The LC1F150R7 can be used in motor starters, industrial machinery, pump systems, compressors, fans, and other installations that require switching performance within its rated operating conditions. Its suitability depends on the motor’s power, current, starting characteristics, switching frequency, and the electrical protection used in the complete installation.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Range TeSys F
Model LC1F150R7
Product Type Industrial Contactor
Contactor Series LC1F
Number of Poles 3P
Main Contact Configuration 3 NO
AC-3 Rated Operational Current 150 A
AC-1 Rated Operational Current 250 A
Rated Operational Voltage Up to 690 V AC
Control Coil Voltage 440 V AC
Control Coil Frequency 40–400 Hz
Normal Application Motor Control and Resistive Loads
AC-3 Motor Power 75 kW at 380–400 V AC
AC-3 Motor Power 80 kW at 415–440 V AC
AC-3 Motor Power 90 kW at 500 V AC
AC-3 Motor Power 100 kW at 660–690 V AC
AC-4 Motor Power 22 kW at 400 V AC
Rated Impulse Withstand Voltage 8 kV
Conventional Free-Air Thermal Current 250 A at 40°C
Rated Short-Time Withstand Current 1200 A for 10 seconds at 40°C
Front Protection IP2X with appropriate shrouds
Dimensions 170 × 163.5 × 171 mm
Weight 3.43 kg

Electrical ratings depend on utilization category, ambient temperature, voltage, and installation conditions. Always consult the applicable manufacturer documentation when selecting the contactor for a specific motor or load.

Function and Working Principle

The LC1F150R7 operates through an electromagnetic switching mechanism. Its control coil generates a magnetic field when energized, causing the internal moving contact assembly to change position. This movement connects or disconnects the three main power circuits.

1. Electromagnetic Coil Operation

The contactor uses a 440 V AC control coil. When the correct control voltage is applied, the coil produces a magnetic field that attracts the moving armature.

This mechanical movement closes the three normally open main contacts. When the coil is de-energized, the magnetic force is removed and the contact mechanism returns to its normal open position.

The coil voltage must match the control supply. Applying an incorrect voltage can cause unreliable operation, excessive heating, or damage to the coil.

2. Three-Pole Main Contact Switching

The LC1F150R7 has three normally open main contacts for switching a three-phase electrical circuit.

When the contactor is energized, the three main contacts close to connect the power supply to the motor or other load. When the coil is de-energized, the contacts open and interrupt the normal operating current.

The three-pole arrangement is commonly used in industrial motor starters and three-phase power-control systems.

3. Motor Starting and Stopping

In a direct-on-line motor starter, the contactor connects the motor directly to the supply when a start command is received. A stop command or protective-device operation interrupts the coil circuit, causing the main contacts to open.

The contactor is a switching component rather than a motor speed controller. It does not independently regulate motor frequency or speed. Where variable-speed operation is required, it may be used alongside a suitable variable frequency drive according to the manufacturer’s switching and protection recommendations.

4. Arc Interruption

When a contactor opens while carrying current, an electrical arc can form between the separating contacts. The contactor’s arc-control design helps manage this switching event.

The ability to interrupt a load depends on the contactor’s rated operational conditions and utilization category. A contactor should not be treated as a substitute for a circuit breaker or short-circuit protective device.

5. Control Circuit Isolation

The coil circuit operates separately from the main power contacts. This allows low-power control equipment, such as PLC outputs or auxiliary relays, to command the switching of a higher-power load through a properly designed control circuit.

The control circuit must be designed with suitable protection and an interface appropriate for the 440 V AC coil.

Role in Industrial Control Systems

The LC1F150R7 can serve as a switching element in industrial motor-control and electrical distribution systems. It connects the control logic of a machine with the power circuit supplying the motor or load.

PLC-Based Motor Control

A PLC can control the contactor through an appropriately rated interface, relay, or control circuit. When the PLC receives a start condition, it can energize the contactor coil through the designed control arrangement.

The PLC may also monitor auxiliary contacts to determine whether the contactor has changed state. This feedback can be used in machine sequencing, alarm handling, and interlock logic.

The PLC output must not be connected directly to the 440 V AC coil unless the output and interface are specifically rated for that voltage and load.

Motor Starter Assemblies

The contactor can be incorporated into a motor starter assembly with suitable overload protection, short-circuit protection, and isolation equipment.

In a conventional starter, the contactor performs the switching function while an overload relay monitors motor current and provides a protective trip signal when required.

The selection of these components must be coordinated to meet the motor’s electrical characteristics and the applicable standards.

Industrial Power Distribution

In some installations, the contactor is used to switch resistive loads or control power circuits as part of an automated electrical distribution arrangement.

The AC-1 and AC-3 ratings are different and should not be interchanged. AC-1 applies to specified non-inductive or slightly inductive loads, while AC-3 applies to squirrel-cage motor starting and switching during normal operation.

Equipment Interlocking

The contactor can be integrated into electrical interlocking arrangements to prevent incompatible equipment from operating simultaneously.

For example, a machine may use control logic to prevent two motor groups from starting at the same time. Such interlocks should be implemented through an appropriate control and safety design rather than relying on the contactor alone.

Industrial Applications

The TeSys F LC1F150R7 is intended for industrial switching applications where its 150 A AC-3 rating and 440 V AC coil configuration match the installation requirements.

1. Industrial Pump Systems

Large industrial pump installations use contactors to connect and disconnect three-phase motors. The LC1F150R7 may be considered for a suitable motor starter where its current and power ratings meet the pump motor’s requirements.

Applications include water circulation, industrial process pumping, cooling systems, and fluid-transfer equipment.

2. Air Compressors

Industrial compressors often use high-power electric motors that require reliable switching and coordinated protection.

The contactor can form part of a compressor motor starter, working with overload protection, pressure-control equipment, and the machine’s control system.

The motor’s starting current and operating duty must be evaluated before selecting the contactor.

3. Ventilation and Fan Systems

Large ventilation equipment and industrial fans use contactors to control motor power. The LC1F150R7 may be suitable for compatible three-phase fan motors within its AC-3 rating.

In automated ventilation systems, a PLC or building-management controller can coordinate contactor operation with temperature, pressure, and airflow signals.

4. Manufacturing Machinery

Industrial production equipment may use contactors to control motors driving conveyors, mixers, material-handling systems, and auxiliary machinery.

The three-pole switching arrangement allows the contactor to control a three-phase power circuit through an appropriately designed motor-control panel.

5. Resistive Heating Equipment

The LC1F150R7 can also be applied to resistive loads within its AC-1 rating and operating conditions.

Examples may include industrial heating circuits and other resistive electrical equipment. The load current, switching frequency, temperature, and required protective devices must be checked before use.

6. Industrial Material Handling

Material-handling systems often contain several motors that operate according to a coordinated production sequence. Contactors can switch individual motor circuits in response to control commands and safety interlocks.

The LC1F150R7 may be considered for appropriately rated equipment such as lifting auxiliaries, conveyors, and heavy-duty handling machinery.

Installation and System Integration

Correct installation is essential for reliable switching, electrical safety, and long-term operation.

1. Verify the Coil Voltage

The LC1F150R7 uses a 440 V AC control coil. Before installation, confirm that the available control supply matches this rating and the specified frequency range.

Do not assume that all LC1F150 contactors have the same coil voltage. Different suffixes identify different coil configurations.

2. Check Main Circuit Ratings

Confirm that the contactor’s AC-3 current rating is suitable for the motor’s full-load current and operating conditions.

For motor applications, consider:

  • Motor rated voltage.
  • Full-load current.
  • Motor power.
  • Starting current.
  • Starting frequency.
  • Load characteristics.
  • Ambient temperature.
  • Required electrical endurance.

For resistive loads, use the applicable AC-1 rating rather than the AC-3 motor rating.

3. Mounting and Panel Layout

The supplied dimensions are 170 × 163.5 × 171 mm, with a listed weight of 3.43 kg.

Provide adequate space for mounting, power connections, control wiring, inspection, and maintenance. Follow the manufacturer’s mounting instructions and clearance requirements.

The panel should also provide suitable ventilation and protection against dust, moisture, and other environmental conditions that could affect electrical equipment.

4. Power Wiring

The main power conductors must be sized according to the load current, installation method, ambient temperature, and applicable electrical standards.

Use the appropriate terminals, lugs, and tightening torque specified by the manufacturer. Loose power connections can create excessive heat and lead to contact damage or equipment failure.

5. Control Wiring

Connect the 440 V AC coil circuit using suitable conductors and protective devices. Ensure that control wiring is clearly identified and separated from other circuits where required.

Where a PLC or low-voltage controller is used, select a properly rated interposing relay or interface device if necessary.

6. Overload and Short-Circuit Protection

A contactor does not provide complete motor overload or short-circuit protection by itself.

A suitable overload relay or motor-protection device should be selected according to the motor’s rated current and application. Upstream fuses or circuit breakers must also be coordinated with the contactor and the installation’s short-circuit requirements.

7. Commissioning and Functional Testing

After installation, inspect all power and control connections. Verify the coil voltage, mechanical operation, contact condition, and protective-device settings.

Test the start and stop sequence under controlled conditions. Confirm that the contactor releases correctly when the control circuit is interrupted and that overload and emergency-stop arrangements operate as designed.

Compatible System Components

The LC1F150R7 is normally installed as part of a larger motor-control assembly. The following components may be used in a suitable system, subject to electrical and mechanical compatibility.

Component Function Integration Considerations
Three-phase AC motor Converts electrical power into mechanical motion Match motor current and power to the contactor’s AC-3 rating
PLC Controls automated motor sequences Use a suitable output interface for the 440 V AC coil
Interposing relay Interfaces low-voltage control signals with the coil circuit Verify coil and contact ratings
Thermal overload relay Protects the motor against sustained overload Select according to motor nameplate current
Circuit breaker or fuses Provides short-circuit protection Coordinate ratings with the contactor and motor circuit
Auxiliary contact block Provides additional control and status contacts Confirm compatible TeSys F accessories
Control transformer or supply Provides the required control voltage Ensure the output matches the coil requirements
Emergency-stop circuit Initiates a machine stop through the designed safety system Use an appropriate safety architecture and approved components
Control cabinet Houses the contactor and associated devices Allow sufficient mounting space and ventilation

Not all listed components are included with the LC1F150R7. Confirm the required accessories and complete starter configuration before purchasing.

Alternative Models and Replacement Considerations

When replacing an LC1F150R7, the most important factors are the main contact ratings, coil voltage, pole arrangement, mounting requirements, and auxiliary-contact configuration.

Alternative or Related Model Replacement Considerations
Schneider Electric LC1F150 series Check the coil suffix carefully; different suffixes represent different control voltages
Schneider Electric LC1F115 series Lower current rating; suitability depends on the actual motor and load
Schneider Electric LC1F185 series Higher current rating; verify dimensions, coil voltage, and accessories
Schneider Electric LC1G150 series Newer TeSys G family option; evaluate mounting, wiring, control, and application compatibility
Schneider Electric TeSys F replacement contactor Confirm manufacturer-recommended replacement information for the exact reference

A replacement should not be selected solely because it has the same number of poles or a similar current rating.

Before substitution, compare:

  • AC-3 rated operational current.
  • AC-1 thermal current.
  • Control coil voltage and frequency.
  • Main contact configuration.
  • Motor power rating at the actual supply voltage.
  • Short-time withstand current.
  • Auxiliary-contact requirements.
  • Mounting dimensions and terminal arrangement.
  • Applicable electrical standards.
  • Coordination with overload and short-circuit protection.

The LC1F150R7’s 440 V AC coil is a particularly important identification point. A replacement with a different coil voltage may not operate correctly in the existing control circuit.

Key Advantages

High-Current Motor Switching

The 150 A AC-3 rating supports suitable three-phase motor-control applications within the manufacturer’s specified operating conditions.

Three-Pole Switching Design

Three normally open main contacts allow the contactor to switch a three-phase power circuit.

440 V AC Control Coil

The R7 coil configuration is designed for a 440 V AC control supply, making it suitable for systems engineered around this voltage.

Multiple Utilization Categories

The TeSys F contactor range supports AC-1, AC-3, and AC-4 application categories, subject to the ratings specified for the exact model and operating conditions.

Industrial Motor-Control Integration

The contactor can be incorporated into PLC-controlled motor starters, pump systems, compressors, fans, and other industrial machinery.

Established TeSys F Design

The TeSys F range provides a contactor platform for industrial power switching and motor-control assemblies.

Maintenance and Replacement Identification

The complete LC1F150R7 catalog number helps distinguish this 440 V AC coil version from other LC1F150 variants, supporting more accurate spare-parts selection.

Technical FAQs

1. What is the Schneider Electric LC1F150R7?

The LC1F150R7 is a three-pole TeSys F industrial contactor designed for motor control and resistive-load switching. It has a 150 A AC-3 rated operational current and a 440 V AC control coil.

2. What does the R7 suffix mean?

The R7 suffix identifies the 440 V AC coil version. This is an important specification when matching the contactor to an existing control circuit.

3. How many main poles does the LC1F150R7 have?

It has three main poles, with three normally open contacts (3 NO). It is designed for switching three-phase power circuits.

4. What is its AC-3 current rating?

The rated operational current is 150 A under the specified AC-3 conditions at voltages up to 440 V AC and the manufacturer’s stated temperature limit.

5. What is its AC-1 current rating?

The AC-1 rated operational current is 250 A under the specified conditions. This rating applies to the relevant non-inductive or slightly inductive load category and should not be substituted for the AC-3 motor rating.

6. Can the LC1F150R7 control an industrial motor?

Yes. It can be used in an appropriately designed motor-control circuit when the motor current, power, voltage, starting conditions, and protective-device coordination are within the contactor’s ratings.

7. Can it be controlled by a PLC?

Yes. A PLC can command the contactor through a suitable control interface. Because this model uses a 440 V AC coil, the PLC output must be connected through an appropriately rated switching arrangement.

8. Does the contactor provide overload protection?

No. The contactor performs switching but does not replace a motor overload relay or short-circuit protective device. Suitable protection must be installed as part of the complete motor starter.

9. What are the dimensions and weight?

The supplied dimensions are 170 × 163.5 × 171 mm, and the listed weight is 3.43 kg. These values should be used as the product listing parameters, with physical measurements checked when exact panel or shipping calculations are required.

10. Can another LC1F150 contactor replace this model?

Not automatically. Other LC1F150 variants may have different coil voltages. Confirm the complete catalog number, especially the coil suffix, along with the main electrical ratings and accessories before replacement.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric LC1F150R7, verify the complete catalog number and confirm that the coil voltage is 440 V AC. This is particularly important when sourcing replacement contactors for existing motor-control panels.

For new or surplus units, inspect the nameplate, terminal condition, housing, mounting points, and contactor mechanism. Confirm whether auxiliary contacts or other accessories are included, as these may be separate components.

During routine maintenance, inspect the main power connections for signs of overheating, check the coil circuit, and examine the contact condition according to the equipment manufacturer’s maintenance procedures. Excessive contact wear, abnormal noise, or inconsistent operation should be investigated before the contactor is returned to service.

The contactor should be used with correctly coordinated overload and short-circuit protection. Avoid using it outside its specified utilization category or electrical ratings. Where the switching duty is frequent or involves demanding motor operation, evaluate electrical endurance and the manufacturer’s application guidance.

For replacement projects, compare the coil voltage, main contact ratings, terminal arrangement, dimensions, and auxiliary-contact requirements. A similar-looking contactor may not be electrically interchangeable.

Conclusion

The Schneider Electric LC1F150R7 TeSys F Contactor is a three-pole industrial contactor designed for motor control and resistive-load switching. It features a 150 A AC-3 rated operational current, a 250 A AC-1 rating, three normally open main contacts, and a 440 V AC control coil.

With dimensions of 170 × 163.5 × 171 mm and a listed weight of 3.43 kg, it can be incorporated into suitable industrial motor starters and power-control assemblies. Accurate coil-voltage identification, proper protective-device coordination, and correct installation are essential for reliable operation and replacement compatibility.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501