The Schneider NS1000H Circuit Breaker is a high-capacity industrial circuit protection device from Schneider Electric’s ComPacT NS family. Designed for low-voltage power distribution systems, it provides protection against electrical overloads and short-circuit faults in industrial facilities, commercial buildings, and large electrical installations.
The NS1000H belongs to the H performance class of the ComPacT NS circuit breaker range. Its rated current class is 1000 A, and the H version provides a rated ultimate short-circuit breaking capacity of 70 kA at 415 V AC. These characteristics make it suitable for distribution applications where substantial current capacity and dependable fault interruption are required.
Circuit breakers play an important role in protecting electrical installations. When an abnormal current condition occurs, the breaker interrupts the circuit to help prevent damage to cables, switchboards, connected equipment, and other electrical components. The appropriate protection settings and breaker configuration must be selected according to the electrical system design.
The NS1000H series is available in different configurations, including three-pole and four-pole versions, fixed and withdrawable mounting arrangements, and different operating mechanisms. Depending on the selected reference, it may be supplied with a MicroLogic trip unit or as a basic circuit breaker frame without a trip unit.
For procurement and replacement projects, the complete Schneider Electric reference number is essential. The NS1000H designation identifies the breaker family and performance class, but does not independently specify every mechanical and protection feature.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Series | ComPacT NS |
| Model | NS1000H |
| Product Type | Industrial Circuit Breaker |
| Breaker Category | Molded Case / Low-Voltage Power Circuit Breaker |
| Rated Current Class | 1000 A |
| Rated Operational Voltage | Up to 690 V AC, depending on configuration |
| Frequency | 50/60 Hz |
| Breaking Capacity Class | H |
| Ultimate Breaking Capacity | 70 kA at 415 V AC |
| Number of Poles | 3P or 4P, depending on configuration |
| Mounting Type | Fixed or withdrawable, depending on reference |
| Operating Mechanism | Manual or electrical, depending on reference |
| Trip Unit | MicroLogic or separate trip unit, depending on configuration |
| Protection Functions | Overload and short-circuit protection when equipped with the appropriate trip unit |
| Dimensions Provided | 224 × 210 × 182 mm |
| Weight Provided | 14 kg |
| Typical Application | Industrial power distribution and electrical protection |
Note: NS1000H covers multiple configurations. The specifications above describe the series and supplied listing information. The exact voltage, pole count, operating mechanism, trip unit, and protection functions must be confirmed against the complete catalog number.
The Schneider NS1000H is designed to protect electrical distribution circuits by interrupting current when abnormal operating conditions exceed the limits established by the selected protection arrangement.
Its operation combines switching contacts, an arc-interruption system, and a compatible protection mechanism.
An overload occurs when a circuit carries more current than its intended operating level for an extended period.
If the breaker is equipped with a suitable trip unit, its overload protection function monitors current and operates according to configured protection characteristics. When the overload condition reaches the trip threshold for the specified duration, the breaker opens the circuit.
This helps protect electrical cables, busbars, and connected equipment from excessive thermal stress.
A short circuit can produce a sudden and extremely high current. Without effective protection, this fault current may cause severe damage to electrical equipment and distribution infrastructure.
The NS1000H H-class design provides a 70 kA ultimate breaking capacity at 415 V AC. This indicates its rated ability to interrupt a specified short-circuit current under the applicable test conditions.
The actual fault level at the installation point must be calculated and compared with the breaker rating before selection.
The circuit breaker also functions as a switching device. Depending on its operating mechanism, authorized personnel can open or close the circuit manually or through an electrical operating mechanism.
This functionality is useful in power distribution systems that require controlled switching, maintenance isolation, or remote operation.
Isolation procedures must still follow the applicable electrical safety requirements. Opening a breaker should not automatically be treated as sufficient proof that equipment is safe to work on.
When a circuit breaker opens under load or fault conditions, an electrical arc may form between its contacts.
The breaker uses an internal arc-extinguishing arrangement to control and interrupt this arc. This process allows the circuit to be disconnected safely within the device’s rated operating conditions.
The high breaking capacity of the NS1000H makes it relevant to installations with substantial available short-circuit current.
In a distribution network, circuit breakers must work together so that a fault is isolated as close as possible to its source.
The appropriate trip-unit settings, time delays, and coordination characteristics help reduce unnecessary interruption to unaffected circuits.
Protection coordination should be evaluated as part of the complete electrical system rather than by considering one breaker independently.
The NS1000H can serve as a major protective switching component in industrial low-voltage distribution systems.
In a main distribution panel, a suitably configured NS1000H can protect a high-current feeder or distribution section. Its 1000 A current class makes it relevant to installations with substantial electrical loads.
The actual application depends on the supply arrangement, calculated load current, fault level, and protection study.
Large motor control centers contain multiple motor starters, drives, and auxiliary electrical circuits. A properly selected main or feeder circuit breaker can protect the distribution section supplying these devices.
The breaker must be coordinated with downstream motor protection and short-circuit protective devices.
The NS1000H may be considered for protection on the low-voltage side of a transformer, provided its rated current, interrupting capacity, and protection characteristics are suitable.
Transformer impedance, available fault current, cable capacity, and downstream protection settings must be included in the engineering assessment.
Industrial facilities may use generators or backup power systems to maintain essential operations during utility interruptions.
A suitable circuit breaker can form part of the associated distribution and switching arrangement. Generator applications require particular attention to fault-current characteristics and protection settings because generator fault behavior differs from that of utility supplies.
The Schneider NS1000H is intended for high-current electrical distribution applications where a suitable breaker configuration is required.
Manufacturing facilities often contain multiple production lines, large motors, heating equipment, and automated machinery. A high-capacity circuit breaker can protect major distribution feeders supplying these systems.
The NS1000H may be used in an appropriately designed main or sub-distribution panel.
Industrial switchboards distribute electrical power to different production areas and equipment groups. Circuit breakers help protect individual feeders and provide controlled switching.
The NS1000H’s 1000 A current class and H-level breaking capacity make it relevant to suitable high-current distribution arrangements.
Data centers require dependable electrical distribution for server rooms, cooling systems, UPS equipment, and supporting infrastructure.
A properly selected high-capacity breaker can protect a main distribution feeder or other suitable electrical section. Selectivity and coordination are particularly important because unnecessary power interruptions can affect critical loads.
Large commercial buildings, transportation facilities, and infrastructure installations may contain high-capacity distribution panels.
The NS1000H can be considered for suitable applications where its electrical and mechanical configuration meets the project requirements.
Industrial substations and facility distribution networks require coordinated protective devices to manage overloads and short circuits.
The NS1000H can be incorporated into a suitable low-voltage distribution arrangement after verification of fault levels, operating voltage, and protection coordination.
Correct installation is essential for the safe and reliable operation of a high-current circuit breaker.
Before installation, identify the complete catalog number and confirm the exact NS1000H configuration.
Important details include:
A basic breaker frame without a trip unit must not be treated as equivalent to a complete protected circuit breaker.
Confirm that the rated current is appropriate for the connected circuit and that the rated operational voltage matches the installation.
The available short-circuit current at the installation point must also be calculated. The breaker must have an adequate breaking capacity for the actual system conditions.
The 70 kA rating at 415 V AC should not be assumed to apply unchanged at every operating voltage.
The supplied dimensions are 224 × 210 × 182 mm. Confirm the manufacturer’s dimensional drawing for the exact reference before preparing the switchboard.
For fixed installations, verify the mounting support, terminal positions, cable access, and required clearances.
For withdrawable versions, confirm the compatibility of the cradle, guide rails, and associated mechanical interlocking arrangements.
The incoming and outgoing conductors must be selected according to the rated current, installation environment, and applicable electrical standards.
Check terminal preparation, conductor cross-section, connection hardware, and tightening torque against the manufacturer’s instructions.
Incorrect electrical connections may cause excessive temperature rise, connection failure, or unreliable operation.
Where a MicroLogic trip unit is installed, protection settings must be selected according to the electrical design.
Relevant settings may include long-time overload protection, short-time protection, and instantaneous short-circuit protection, depending on the trip-unit model.
Protection settings should be established through a coordination study and verified by qualified electrical personnel.
Before energizing the installation, inspect the breaker, mounting arrangement, electrical connections, and associated accessories.
Check mechanical opening and closing functions, operating mechanism performance, auxiliary contacts, and trip-unit configuration where applicable.
Testing should follow the manufacturer’s procedures and the project’s electrical commissioning requirements.
The NS1000H is generally installed as part of a larger electrical distribution system.
| Component | Function | Integration Considerations |
|---|---|---|
| Main distribution panel | Houses and distributes electrical power | Confirm mounting dimensions and rated current |
| Busbar system | Distributes current between electrical devices | Verify current capacity, connection layout, and short-circuit withstand rating |
| MicroLogic trip unit | Provides electronic protection functions | Select a compatible unit and configure protection settings |
| Electrical operating mechanism | Enables remote or electrical opening and closing | Confirm compatibility with the breaker reference |
| Auxiliary contacts | Provide breaker status signals | Verify contact arrangement and control voltage |
| Shunt trip accessory | Enables remote tripping | Confirm coil voltage and accessory compatibility |
| Undervoltage release | Trips or prevents closing under specified voltage conditions | Verify voltage rating and control-circuit design |
| Current transformers | Supply measurement signals where required | Confirm ratio, accuracy, and system integration |
| Switchboard enclosure | Provides mechanical protection and mounting | Check clearances, ventilation, and electrical ratings |
| Downstream circuit breakers | Protect individual outgoing circuits | Perform protection coordination and selectivity checks |
Accessories and trip units may be ordered separately depending on the breaker configuration. Always verify the supplied bill of materials.
The ComPacT NS family includes several current and performance classes. A replacement must be selected according to the actual electrical and mechanical requirements.
| Alternative Model or Series | Description | Replacement Considerations |
|---|---|---|
| ComPacT NS800H | 800 A class, H performance | Lower current class; not a direct replacement without load assessment |
| ComPacT NS1000N | 1000 A class, N performance | Different short-circuit breaking capacity |
| ComPacT NS1000L | 1000 A class, L performance | Higher breaking-capacity class; verify configuration |
| ComPacT NS1250H | 1250 A class, H performance | Higher current class; check cable and protection coordination |
| ComPacT NS1600H | 1600 A class, H performance | Higher current class and potentially different physical requirements |
| Newer Schneider Electric ComPacT products | Current-generation circuit protection equipment | Requires detailed electrical and mechanical compatibility review |
Before selecting an alternative, compare:
A breaker with the same 1000 A rating is not necessarily a suitable substitute. The breaking capacity, trip-unit characteristics, mechanical dimensions, and accessory configuration must also match the application.
The NS1000H is designed for high-current distribution applications with a 1000 A current class.
Its H performance class provides a 70 kA ultimate breaking capacity at 415 V AC, making it suitable for appropriately engineered systems with substantial prospective fault currents.
The ComPacT NS1000H family offers different pole arrangements, mounting styles, operating mechanisms, and trip-unit configurations.
When equipped with the appropriate trip unit, the breaker can provide protection against overload and short-circuit conditions.
The range supports integration into industrial switchboards and distribution systems using compatible accessories and control components.
The NS1000H is relevant to maintenance projects involving existing ComPacT NS installations. Accurate catalog identification helps reduce the risk of selecting an incompatible replacement.
The Schneider NS1000H is a high-capacity circuit breaker in the ComPacT NS family. It is designed for low-voltage electrical distribution and has a 1000 A current class with H-level short-circuit breaking performance.
The NS1000H is a 1000 A class breaker. The actual rated current and permissible settings depend on the selected configuration and installed trip unit.
The H performance version provides a rated ultimate breaking capacity of 70 kA at 415 V AC. The applicable rating should always be checked against the operating voltage and manufacturer’s technical documentation.
Yes. The ComPacT NS1000H family includes both three-pole and four-pole configurations, depending on the complete product reference.
No. Some versions are supplied as basic breaker frames without a trip unit. Other configurations include a MicroLogic protection unit. The exact catalog number must be checked before ordering.
Yes. Electrically operated versions are available within the ComPacT NS1000H range. Manual and electrical operating configurations should not be treated as mechanically identical.
Both belong to the 1000 A ComPacT NS family, but they have different short-circuit performance classes. The H version is rated at 70 kA at 415 V AC, while the N version has a lower breaking-capacity rating. The correct choice depends on the calculated fault current.
It may be used on a suitable transformer feeder or secondary distribution circuit. Selection requires checking transformer capacity, rated voltage, available short-circuit current, cable protection, and coordination with downstream devices.
Confirm the full catalog number, pole count, trip-unit type, mounting arrangement, operating mechanism, voltage rating, breaking capacity, and accessories. Also verify that the replacement fits the existing switchboard.
The supplied listing information gives dimensions of 224 × 210 × 182 mm and a weight of 14 kg. Actual dimensions and weight can vary according to the breaker configuration and included accessories, so verify the physical unit before shipping or installation.
When purchasing a Schneider NS1000H circuit breaker, the first step is to identify the complete product reference. The NS1000H family includes several configurations, and the family designation alone is insufficient to confirm the exact trip unit, pole arrangement, and operating mechanism.
For replacement applications, compare the original nameplate and technical documentation with the proposed unit. Confirm whether the breaker includes a protection unit, electrical operating mechanism, auxiliary contacts, and other required accessories.
For used or refurbished equipment, request clear photographs of the nameplate, terminals, operating mechanism, and visible internal components where appropriate. Ask for information about the product’s condition and available functional testing.
During maintenance, inspect electrical connections, mounting hardware, operating mechanisms, and auxiliary circuits according to the manufacturer’s recommendations. Protection settings should be reviewed after any major change to the electrical distribution system.
Because this is a high-current protective device, installation, testing, and maintenance should be performed by qualified electrical personnel using appropriate safety procedures.
The Schneider NS1000H Circuit Breaker is a high-capacity ComPacT NS product designed for industrial and commercial low-voltage power distribution. With a 1000 A current class and an H-level ultimate breaking capacity of 70 kA at 415 V AC, it is intended for applications that require substantial current handling and dependable short-circuit interruption.
The NS1000H family offers multiple configurations, including different pole arrangements, mounting methods, operating mechanisms, and trip-unit options. For procurement and replacement projects, verifying the complete catalog number is essential to ensure electrical, mechanical, and protection compatibility.