| 15980777398 |

The Epro PR6424/119-021 16 mm Eddy Current Sensor is a non-contact displacement sensor designed for monitoring the condition and operating behavior of rotating machinery. It belongs to the PR6424 sensor family, which is used in industrial machinery protection and condition-monitoring systems.
Eddy current sensors measure the distance between the probe tip and a conductive target without requiring physical contact. In rotating equipment, the target is commonly a ferromagnetic steel shaft. Changes in the distance between the probe and the shaft produce corresponding changes in the sensor’s electrical response. A compatible signal converter or monitoring system processes this response to determine shaft displacement, vibration, or position.
The PR6424 series is commonly used in applications involving steam turbines, gas turbines, compressors, pumps, and industrial fans. These machines depend on stable shaft operation, bearing condition, and mechanical alignment. Continuous displacement and vibration measurements can help operators identify abnormal movement and investigate developing mechanical problems.
The PR6424/119-021 is identified as a 16 mm eddy current sensor. Its 16 mm sensing head is intended for installations where a suitable mounting arrangement and measurement clearance are available. The sensor is designed to operate as part of a complete measurement chain rather than as an independent display or monitoring instrument.
Typical PR6424 family specifications include a sensitivity of 4 V/mm, a static measurement range of ±2.0 mm, and a nominal center air gap of approximately 2.7 mm. These are family-level reference values; the exact cable length, connector arrangement, and mounting details should be confirmed against the complete ordering information for PR6424/119-021.
| Parameter | Specification |
|---|---|
| Brand | Epro |
| Manufacturer / Product Line | Emerson EPRO |
| Model | PR6424/119-021 |
| Product Series | PR6424 |
| Product Type | 16 mm Eddy Current Sensor |
| Measurement Principle | Non-contact eddy current |
| Sensor Head Diameter | 16 mm |
| Reference Sensitivity | 4 V/mm |
| Reference Linearity | ≤ ±1.5% |
| Static Measurement Range | ±2.0 mm |
| Dynamic Measurement Range | 0–1,000 μm peak-to-peak |
| Nominal Center Air Gap | Approximately 2.7 mm |
| Typical Target Material | Ferromagnetic steel |
| Reference Shaft Diameter | ≥80 mm |
| Sensor Sleeve Material | Stainless steel |
| Cable Material | PTFE |
| Reference Operating Temperature | Confirm exact variant documentation |
| Weight Provided | 0.2 kg |
| Typical Applications | Turbines, compressors, pumps, fans, and rotating machinery |
Note: Electrical performance figures are based on published PR6424 family specifications. Confirm the exact temperature rating, cable length, connector type, and mechanical configuration for PR6424/119-021 before installation. The approximately 0.2 kg family reference weight is specified for a sensor with a 1 m cable without armor.
The PR6424/119-021 uses the eddy current principle to measure the distance between its sensing head and a conductive target. It provides a non-contact measurement method suitable for machinery where the target moves continuously during operation.
An eddy current probe contains a sensing coil near its tip. When the associated measurement electronics energize the coil with an alternating electrical signal, an electromagnetic field is generated around the probe head.
When a conductive metal target enters this field, electrical currents known as eddy currents are induced in the target surface. These currents influence the electromagnetic characteristics of the sensing coil.
The resulting electrical change is related to the distance between the probe and the target.
As the shaft moves relative to the sensor, the gap between the probe tip and the shaft surface changes. The probe’s electrical response changes accordingly.
A compatible signal converter processes the response and produces a measurement signal that can be interpreted by a machinery monitoring system.
This arrangement allows the system to monitor shaft movement without direct mechanical contact between the sensor and the rotating component.
The PR6424 family has a published static measurement range of approximately ±2.0 mm. Within the specified measurement range and correct installation conditions, the system can monitor changes in shaft position relative to the probe.
Static displacement measurements are useful for observing shaft position, axial movement, and changes in mechanical alignment.
When a shaft vibrates, the distance between the shaft surface and the stationary probe changes continuously. The sensor detects these variations, allowing the monitoring system to evaluate shaft vibration.
Dynamic measurement is particularly important for high-speed rotating machinery. Abnormal vibration may be associated with imbalance, misalignment, bearing wear, looseness, or other mechanical conditions.
The sensor provides measurement information; diagnosis requires analysis of the signal together with machine operating conditions and other monitoring data.
The probe is normally connected to compatible signal-conditioning electronics. These electronics convert the probe response into a usable output for a machinery monitoring or protection system.
Depending on the system configuration, the resulting signal may be used for:
The sensor, cable, converter, and monitoring input must be selected as a compatible measurement chain.
The PR6424/119-021 is intended to function as a sensing element in a larger machinery monitoring arrangement. Its measurements can help maintenance teams understand the movement and operating condition of rotating equipment.
Shaft vibration is an important indicator of rotating machinery condition. Excessive or changing vibration can be associated with imbalance, misalignment, mechanical looseness, bearing problems, or changes in operating conditions.
A correctly installed eddy current sensor can provide continuous shaft-displacement information for monitoring and diagnostic purposes.
Axial shaft movement can be important in turbines, compressors, and other rotating machines. Monitoring axial position helps operators observe changes in the shaft’s location relative to the machine structure.
Where axial displacement is a critical protection parameter, the sensor arrangement and monitoring channel must be designed according to the equipment manufacturer’s requirements.
A machinery protection system can use sensor signals to evaluate operating conditions and identify measurements that exceed configured limits.
The PR6424 sensor itself does not independently perform all protection functions. Alarm and trip decisions depend on the connected monitoring hardware, configured thresholds, signal quality, and overall protection-system design.
Measurement signals can be incorporated into a plant’s machinery monitoring and maintenance strategy. Engineers may compare vibration and displacement trends with operating speed, load, temperature, and other machine data.
This information can support condition-based maintenance and help maintenance teams investigate changes before they develop into more serious equipment problems.
The PR6424 16 mm eddy current sensor family is intended for critical rotating machinery. Its non-contact measurement principle makes it suitable for applications where continuous shaft movement must be monitored.
Steam turbines operate at high rotational speeds and require reliable monitoring of shaft behavior. Eddy current sensors can measure shaft vibration and displacement, providing information that helps operators assess mechanical stability.
Typical monitoring objectives include observing radial shaft movement, tracking changes in vibration, and supporting machinery protection strategies.
Gas turbines are used in power generation and industrial energy systems. Their rotating assemblies operate under demanding mechanical and thermal conditions.
A suitable eddy current sensor arrangement can provide shaft-displacement measurements for machinery monitoring systems. Correct sensor positioning and temperature compatibility are essential.
Centrifugal and other high-speed compressors require accurate monitoring of rotating components. Shaft vibration and displacement measurements can help identify changes in mechanical behavior.
The PR6424 family is relevant to compressor applications where non-contact shaft measurement is required. The exact probe and monitoring configuration should be selected according to the compressor design.
Large industrial pumps may operate continuously in power plants, refineries, chemical facilities, and water-processing installations.
Eddy current sensors can be used in suitable pump monitoring arrangements to observe shaft movement and vibration. Their measurements can support maintenance assessments and investigation of abnormal operating conditions.
Large fans and blower systems can experience imbalance, misalignment, and mechanical looseness. Shaft vibration monitoring helps maintenance personnel identify changes in operating behavior.
A properly installed eddy current sensor can provide non-contact displacement information for compatible fan monitoring systems.
Rotating electrical machines require mechanical stability as well as electrical performance. Shaft movement measurements can contribute to the assessment of rotor behavior and machine condition.
The sensor should be selected and installed according to the generator’s monitoring design and the requirements of the connected protection system.
Correct installation is essential for measurement accuracy and long-term reliability. The probe must be mounted securely, positioned correctly, and connected to compatible monitoring electronics.
Before installation, confirm that the sensor is PR6424/119-021. Do not rely only on the PR6424 family designation.
Different ordering suffixes can identify different cable lengths, connector arrangements, mounting details, and other configuration characteristics. Confirm these details before selecting replacement cables or converters.
The probe should be positioned so that its sensing head faces the intended conductive target. The mounting arrangement must maintain the required measurement clearance and prevent unwanted contact between the probe and rotating components.
The sensor should be installed in a mechanically stable position. Vibration or movement of the mounting bracket can introduce measurement errors.
The PR6424 family specifies a nominal center air gap of approximately 2.7 mm. This is a reference value rather than a substitute for the installation procedure applicable to the exact probe and measurement system.
The initial gap must be established according to the manufacturer’s instructions and the connected converter’s requirements.
An incorrect gap may reduce measurement accuracy or cause the sensor to operate outside its intended linear range.
Eddy current measurement depends on the electrical and magnetic properties of the target material. Published PR6424 specifications use ferromagnetic steel as the reference target material.
If the shaft material differs from the reference material, verify the measurement characteristics and calibration requirements before commissioning.
The sensor cable should be routed away from sources of mechanical damage, excessive heat, and electrical interference.
Avoid sharp bends, crushing, and unnecessary tension. Maintain the specified minimum bending radius for the actual cable configuration. If the installation uses armored cable, confirm the applicable bending requirements.
The cable and connector must also be compatible with the associated signal converter.
The probe should be connected to the appropriate EPRO signal converter or compatible machinery monitoring equipment.
Confirm the complete sensor and converter combination before energizing the system. A probe from the same product family is not automatically interchangeable with every converter or monitoring channel.
After installation, establish the correct air gap and verify the signal using the prescribed commissioning procedure.
Check the sensor response, cable condition, connector integrity, and measurement stability. Compare the results with the expected operating range and document the initial measurement condition.
The PR6424/119-021 operates as part of a complete eddy current measurement system. The following components represent typical equipment categories used in such installations.
| Component | Function | Compatibility Considerations |
|---|---|---|
| EPRO signal converter | Conditions the probe signal | Confirm compatibility with the exact PR6424 probe configuration |
| Machinery monitoring system | Processes and evaluates measurement signals | Verify sensor input type and measurement-channel settings |
| Extension cable | Connects the probe to the converter | Match cable type, connector, and electrical characteristics |
| Probe mounting bracket | Holds the sensor in position | Maintain mechanical stability and correct measurement clearance |
| Shaft target | Provides the conductive measurement surface | Confirm material and surface suitability |
| PLC or DCS | Receives process or monitoring information | Integration depends on the monitoring system’s available outputs |
| Machinery protection system | Evaluates operating conditions and protection limits | Configure alarm and trip functions according to the machine protection design |
| Cable protection accessories | Protect the cable in industrial environments | Select according to temperature, vibration, and mechanical conditions |
The exact compatible converter, extension cable, and monitoring equipment should be determined from the complete sensor ordering information and the existing machinery monitoring system.
The PR6424 series includes different probe variants and cable configurations. A replacement should not be selected based only on the 16 mm head diameter.
| Alternative or Related Model | Consideration |
|---|---|
| EPRO PR6424 series variants | May share the 16 mm sensing principle, but cable, connector, mounting, and environmental specifications can differ |
| EPRO PR6424/000-100 | A related PR6424 configuration; verify its mechanical and cable arrangement before considering substitution |
| EPRO PR6423 series | A different sensor family variant; measurement range and probe configuration must be checked |
| EPRO PR6422 series | Another related eddy current sensor family with different measurement characteristics |
| Compatible EPRO measurement system | The converter and monitoring channel must match the selected probe and cable configuration |
Before replacing the PR6424/119-021, check:
A probe with the same diameter may not be electrically or mechanically interchangeable. For critical machinery, verify the replacement against the original equipment documentation.
The sensor measures shaft displacement without physical contact with the rotating target. This avoids the mechanical wear associated with contact-based measurement methods.
The PR6424 family is designed for applications involving turbines, compressors, pumps, fans, and other rotating equipment.
The sensor can provide information about changes in the distance between the probe and the shaft, supporting radial displacement and vibration monitoring.
Published PR6424 family specifications include 4 V/mm sensitivity and a static measurement range of ±2.0 mm. These characteristics provide a technical basis for suitable machinery monitoring applications.
The family documentation identifies a stainless-steel sensor sleeve and PTFE cable construction. These materials are intended for demanding industrial measurement environments within the specified operating limits.
When paired with compatible signal-conditioning electronics, the probe can supply measurement information to machinery monitoring and protection equipment.
The 16 mm sensing head supports installation in machinery locations designed for this probe size, subject to the required mounting clearance and mechanical arrangement.
It is a 16 mm non-contact eddy current sensor used for measuring shaft displacement and vibration in compatible rotating machinery monitoring systems.
The supplied specification identifies a 16 mm sensor head diameter.
It uses electromagnetic induction. An alternating field generated by the sensing coil interacts with the conductive target, and changes in the electrical response are used to determine the distance between the probe and the target.
Published PR6424 family specifications give a reference sensitivity of 4 V/mm. Confirm the exact measurement-chain configuration before using this value for calibration or replacement planning.
The published PR6424 family static measurement range is approximately ±2.0 mm.
The PR6424 family documentation specifies an approximate nominal center air gap of 2.7 mm. The actual installation gap should follow the applicable sensor and converter instructions.
The published reference target material is ferromagnetic steel. Other target materials may produce different measurement characteristics and require verification.
Typical applications include steam turbines, gas turbines, compressors, pumps, and industrial fans. The sensor can be used where non-contact shaft displacement or vibration measurement is required.
The probe is normally used with compatible signal-conditioning electronics. The converter processes the probe response and provides a signal suitable for the monitoring system.
Verify the complete model number, cable length, connector, mounting dimensions, sensitivity, measurement range, target material, and converter compatibility. The full suffix is important because different variants may have different mechanical or electrical configurations.
When purchasing the Epro PR6424/119-021, verify the complete model number and inspect the probe’s physical condition. The sensing tip, threaded body, cable, and connector should be checked for damage, deformation, corrosion, or signs of previous mechanical stress.
Confirm whether the supplied item includes the required cable and connector arrangement. The listed weight of 0.2 kg should be treated as the supplied product-listing value; published family data gives approximately 200 grams for a sensor with a 1 m cable without armor. Cable length and protection can affect the actual weight.
For replacement projects, compare the new probe with the installed unit and check compatibility with the existing signal converter and monitoring system. A matching 16 mm head diameter alone is not sufficient to establish interchangeability.
During maintenance, inspect the cable routing, connector condition, mounting stability, and sensor clearance. Avoid damaging the sensing tip during removal or installation. Record the installed air gap and baseline measurement values so that future readings can be compared with the original operating condition.
For critical rotating machinery, sensor replacement and commissioning should follow the equipment manufacturer’s procedures and the plant’s machinery protection requirements.
The Epro PR6424/119-021 16 mm Eddy Current Sensor is designed for non-contact measurement of shaft displacement and vibration in industrial rotating machinery. Its PR6424 family characteristics, including 4 V/mm reference sensitivity, ±2.0 mm static measurement range, and approximately 2.7 mm nominal center air gap, make it suitable for appropriately configured machinery monitoring applications.