• Epro ZW0502/1217/0211+PR6423/005-0F2 8 mm Eddy Current Sensor
  • Epro ZW0502/1217/0211+PR6423/005-0F2 8 mm Eddy Current Sensor
  • Epro ZW0502/1217/0211+PR6423/005-0F2 8 mm Eddy Current Sensor
  • Epro ZW0502/1217/0211+PR6423/005-0F2 8 mm Eddy Current Sensor
Product Overview The Epro ZW0502/1217/0211 + PR6423/005-0F2 Eddy Current Sensor System is a non-contact displacement measurement configuration designed for industrial machinery monitoring. It combines t……
Epro ZW0502/1217/0211+PR6423/005-0F2 8 mm Eddy Current Sensor
  • Epro
  • ZW0502/1217/0211+PR6423/005-0F2
  • 8 mm Eddy Current Sensor
  • Germany
  • 8 mm
  • 0.1 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Epro ZW0502/1217/0211+PR6423/005-0F2 8 mm Eddy Current Sensor

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Epro ZW0502/1217/0211+PR6423/005-0F2 8 mm Eddy Current Sensor

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Epro ZW0502/1217/0211+PR6423/005-0F2 8 mm Eddy Current Sensor

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Epro ZW0502/1217/0211+PR6423/005-0F2 8 mm Eddy Current Sensor

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Epro ZW0502/1217/0211 + PR6423/005-0F2 Eddy Current Sensor System is a non-contact displacement measurement configuration designed for industrial machinery monitoring. It combines the PR6423/005-0F2 eddy-current proximity probe with the associated ZW0502/1217/0211 signal-conversion unit. The system is intended to measure the movement of conductive metallic targets, particularly rotating machinery shafts.

Eddy-current measurement technology is widely used in condition-monitoring applications because it can detect shaft movement without requiring physical contact between the probe and the monitored surface. This makes it suitable for equipment operating at high rotational speeds, where continuous mechanical contact would be impractical.

The PR6423/005-0F2 is an 8 mm probe configuration. It is designed to measure static and dynamic displacement, including radial shaft vibration, axial shaft movement, and shaft position. The associated converter processes the probe signal and provides an output suitable for connection to an appropriate monitoring or control system.

This type of measurement is important in machinery where changes in shaft position or vibration can indicate developing mechanical problems. Monitoring data can help maintenance teams identify abnormal operating conditions and investigate potential bearing wear, rotor imbalance, misalignment, or other mechanical issues.

The product is relevant to rotating equipment such as turbines, compressors, pumps, and other critical industrial machinery. Correct installation requires attention to the probe, converter, extension cable, target material, measurement gap, and monitoring-system configuration.

Technical Specifications

Parameter Specification
Brand Epro / Emerson
System Designation ZW0502/1217/0211 + PR6423/005-0F2
Product Type Eddy Current Displacement Measurement System
Sensor Model PR6423/005-0F2
Converter Model ZW0502/1217/0211
Measurement Principle Eddy-current technology
Measurement Type Non-contact displacement
Probe Diameter 8 mm
Linear Measurement Range 0–5 mm
Incremental Scale Factor Approximately 8 V/mm
Target Material Conductive ferromagnetic metal
Typical Target Material Ferromagnetic steel
Probe Protection IP66
Probe Operating Temperature -35°C to +200°C, including specified cable configuration
Cable and Connector Temperature -35°C to +150°C
Converter Mounting DIN rail
Converter Protection IP20
Converter Frequency Response 0–20 kHz (-3 dB), according to converter specification
Converter Rise Time Less than 15 μs
Typical Applications Shaft vibration, axial displacement, radial displacement, and position monitoring
Sensor Head Diameter 8 mm
Dimensions Provided 8 mm probe diameter
Weight Provided 0.1 kg

Note: The supplied weight of 0.1 kg is treated as the listing weight for the probe configuration. The complete assembly weight may vary depending on the converter, cable, connectors, and accessories included. Confirm the exact order contents before procurement.

Function and Working Principle

The Epro PR6423/005-0F2 uses the eddy-current principle to measure the distance between the probe tip and a conductive metallic target. It converts changes in this distance into an electrical signal that can be processed by the associated measurement electronics.

1. Eddy-Current Measurement

When the probe is energized, it produces an electromagnetic field around its sensing tip. When a conductive metallic target approaches the probe, the electromagnetic field induces electrical currents in the target material.

These currents are known as eddy currents. Their effect changes the electrical characteristics of the probe circuit. The measurement electronics evaluate this change and determine the distance between the probe and the target.

Because the process does not require physical contact, the probe can monitor the surface of a rotating shaft while the machine is operating.

2. Shaft Displacement Measurement

The probe detects changes in the distance between its sensing tip and the shaft surface. These changes can represent radial movement, axial movement, or other displacement depending on the probe’s orientation.

For radial vibration monitoring, probes are commonly installed near the shaft at designated measurement positions. The measured signal can help identify changes in shaft movement during operation.

For axial displacement monitoring, the probe is positioned to measure movement along the shaft axis. This is particularly relevant to machines where axial thrust and rotor position are important operating parameters.

3. Signal Conversion

The PR6423 probe works with compatible measurement electronics. The ZW0502/1217/0211 converter configuration processes the sensor signal and provides an electrical output for the monitoring system.

The converter is an important part of the measurement chain. Correct matching between the probe, converter, cables, connectors, and monitoring equipment is necessary to obtain reliable measurements.

4. Dynamic and Static Measurement

Eddy-current systems can measure both static and dynamic displacement.

Static measurement can be used to observe shaft position or changes in the operating gap. Dynamic measurement can capture vibration-related movement and other rapidly changing mechanical conditions.

The useful measurement bandwidth depends on the complete sensor and converter configuration, as well as the monitoring equipment and installation.

Role in Industrial Machinery Monitoring

The ZW0502/1217/0211 + PR6423/005-0F2 system can form part of a machinery protection or condition-monitoring arrangement. It provides displacement information that helps operators and maintenance engineers evaluate the mechanical condition of rotating equipment.

Shaft Vibration Monitoring

Shaft vibration is an important indicator of rotating machinery condition. Changes in vibration amplitude or operating patterns may be associated with imbalance, misalignment, bearing problems, looseness, or other mechanical issues.

The eddy-current probe provides non-contact shaft displacement measurements that can be evaluated by a compatible monitoring system.

Axial Position Monitoring

Axial shaft position is important in turbines, compressors, and other machines with thrust-bearing arrangements. Excessive axial movement may indicate a mechanical condition requiring investigation.

When installed in the correct orientation, the probe can provide displacement information for monitoring axial shaft movement.

Bearing Condition Assessment

Changes in shaft position and vibration can help maintenance teams investigate bearing-related problems. The probe does not directly diagnose bearing failure, but its measurement data can contribute to a broader condition-monitoring strategy.

Machinery Protection

In critical machinery applications, displacement measurements may be connected to monitoring equipment configured with alarm and shutdown functions. The monitoring system evaluates the incoming signals against established operating limits.

The sensor itself is a measurement component. Alarm thresholds, trip logic, and machinery shutdown functions must be implemented and validated within the appropriate monitoring and protection system.

Industrial Applications

The Epro 8 mm eddy-current probe configuration is suitable for applications requiring non-contact measurement of metallic shaft displacement.

1. Steam and Gas Turbines

Turbines operate at high rotational speeds and can experience changes in shaft position and vibration due to operating conditions or mechanical deterioration.

Eddy-current probes can be installed at designated measurement locations to monitor radial shaft vibration and axial displacement. These measurements can support machinery condition assessment and protection strategies.

2. Industrial Compressors

Centrifugal and other rotating compressors require monitoring of shaft movement and mechanical stability. Changes in vibration can indicate developing issues such as rotor imbalance, misalignment, or bearing deterioration.

The PR6423 probe can provide displacement information for compatible compressor monitoring systems.

3. Industrial Pumps

Large pumps used in power generation, petrochemical processing, and water treatment may require continuous vibration and shaft-position monitoring.

Non-contact measurement is useful where the shaft rotates continuously and physical contact with the monitored surface is not practical.

4. Gearboxes and Rotating Machinery

Gearboxes and other rotating equipment may experience changes in shaft movement due to wear, load variation, or mechanical defects.

When the probe installation and target geometry are suitable, displacement measurements can contribute to machinery condition monitoring.

5. Power Generation Facilities

Power plants rely on turbines, generators, pumps, and auxiliary rotating equipment. Continuous monitoring of shaft vibration and position can help maintenance teams evaluate equipment behavior and plan inspections.

The Epro sensor configuration can be considered for machinery installations that use compatible eddy-current monitoring systems.

6. Petrochemical and Process Industries

Compressors, pumps, and other rotating machines are essential to many chemical and petrochemical processes. Monitoring shaft displacement can help identify abnormal mechanical behavior before it develops into a more serious operational issue.

For hazardous-area installations, the complete measurement loop must be checked against the applicable certification and installation requirements. A probe’s protection rating alone does not establish the suitability of the entire system for a hazardous location.

Installation and System Integration

Accurate eddy-current measurement depends on the correct installation of the probe and its associated electronics.

1. Verify Probe and Converter Compatibility

Before installation, confirm that the PR6423/005-0F2 probe is compatible with the ZW0502/1217/0211 converter and the associated cables and connectors.

Do not assume that every PR6423 probe can be connected to every converter configuration. Check the complete model numbers and manufacturer documentation.

2. Select the Correct Measurement Position

The probe should be mounted at the measurement location specified by the machinery design. For shaft vibration measurement, the probe is normally positioned near the shaft surface with a suitable mounting arrangement.

For axial displacement measurement, the probe must be aligned with the intended axial target surface.

Probe position, mounting stiffness, and target geometry all influence measurement quality.

3. Set the Initial Air Gap

The initial distance between the probe tip and the metallic target must be established according to the manufacturer’s calibration and installation requirements.

The correct gap is essential for maintaining the probe within its linear measurement range. An incorrect gap may result in inaccurate readings, limited measurement range, or an invalid signal.

Do not determine the installation gap from the nominal measurement range alone. Follow the specific probe and converter instructions.

4. Check Target Material and Surface

Eddy-current measurement depends on the electrical and magnetic properties of the target material. The PR6423 system is designed for suitable conductive metallic targets, with ferromagnetic steel specified for typical applications.

Surface condition, target diameter, material properties, and nearby metallic structures should be considered during installation.

5. Route Cables Correctly

Probe cables and converter connections should be installed according to the manufacturer’s wiring recommendations. Avoid unnecessary cable extensions, improper connectors, and routing arrangements that may introduce electrical interference.

Where the installation involves long cable runs or multiple measurement channels, verify the complete cable configuration and channel compatibility.

6. Mount the Converter

The ZW0502 converter is designed for DIN-rail mounting and has an IP20 protection configuration. It should be installed in a suitable electrical cabinet with adequate environmental protection.

Maintain clear separation between sensitive measurement wiring and power conductors where required. Proper grounding and cabinet layout help reduce interference.

7. Commission and Verify the Measurement

After installation, verify the probe gap, signal output, converter operation, and monitoring-system response.

Compare the measured output with the expected displacement range. Check for abnormal signal fluctuations, cable faults, unstable readings, and incorrect scaling.

Record the final installation details and measurement settings for future maintenance.

Compatible System Components

The sensor configuration operates as part of a complete measurement chain. The following components may be required depending on the installation.

Component Function Integration Considerations
PR6423/005-0F2 probe Detects shaft displacement without contact Confirm probe diameter, model, target material, and mounting arrangement
ZW0502/1217/0211 converter Processes the probe signal Verify exact compatibility with the probe and output requirements
Probe extension cable Connects the probe to the measurement electronics Confirm cable type, length, and connector compatibility
Monitoring module Receives and evaluates measurement signals Check input range, scaling, and channel configuration
Machinery protection system Evaluates vibration and displacement conditions Configure alarm and trip limits according to the machinery design
PLC or DCS Integrates monitoring information into plant control Confirm signal type and interface compatibility
DIN rail Supports converter mounting Use a suitable cabinet mounting arrangement
Shielded instrumentation cable Carries measurement or output signals Follow grounding and shielding recommendations
Metallic shaft or target Provides the surface being measured Confirm target material, diameter, and surface condition

The components listed are examples of a complete measurement installation. They are not necessarily included in the supplied product package.

Alternative Models and Replacement Considerations

When replacing an Epro eddy-current probe, the replacement should be selected according to the complete measurement system rather than probe diameter alone.

Alternative or Related Model Application Consideration
Epro PR6423/00 series Related 8 mm eddy-current probe configurations; check thread, cable, and mounting options
Epro PR6423/01 series Related 8 mm probe configuration with different cable and construction options
Epro PR6423/10 series Related 8 mm configuration with a different thread standard
Epro PR6423/11 series Related probe configuration; confirm cable and installation details
Epro PR6424 series Another eddy-current probe family; verify measurement range and system compatibility
Compatible Epro measurement converter Required for correct signal conditioning and measurement output

Before selecting a replacement, compare:

  • Complete probe model number and suffix.
  • Probe diameter and mounting thread.
  • Measurement range and sensitivity.
  • Initial air gap and calibration requirements.
  • Cable length and connector type.
  • Converter compatibility.
  • Target material and shaft diameter.
  • Temperature and environmental ratings.
  • Monitoring-system input requirements.
  • Any required hazardous-area approvals.

A probe with the same 8 mm diameter is not necessarily a direct replacement. Differences in sensitivity, measurement range, cable configuration, and converter compatibility can affect the complete measurement system.

Key Advantages

Non-Contact Measurement

The eddy-current principle allows the probe to measure shaft displacement without physical contact with the rotating surface. This supports continuous monitoring without mechanical wear at the sensing interface.

Compact 8 mm Probe Design

The 8 mm sensing head is suitable for installations where mounting space is limited and a compact proximity probe is required.

Static and Dynamic Displacement Measurement

The system can be used for shaft-position and vibration-related measurements, supporting different machinery monitoring requirements.

High-Temperature Probe Capability

The PR6423 probe documentation specifies a high operating-temperature capability for the probe and its defined cable configuration. The temperature limits of the cable, connector, and converter must also be observed.

Industrial Machinery Applications

The system is suitable for appropriately configured monitoring installations on turbines, compressors, pumps, and other rotating equipment.

Integration with Monitoring Systems

The converter provides signal conditioning for connection to compatible machinery monitoring equipment. Correct system matching is essential for reliable measurement.

Support for Predictive Maintenance

Continuous displacement measurements can help maintenance teams identify changes in machinery behavior and investigate potential mechanical problems before they result in unplanned downtime.

Technical FAQs

1. What is the Epro ZW0502/1217/0211 + PR6423/005-0F2?

It is an eddy-current displacement measurement configuration combining a ZW0502/1217/0211 converter with a PR6423/005-0F2 proximity probe. It is designed for non-contact measurement of metallic target displacement.

2. What is the diameter of the PR6423/005-0F2 probe?

The probe has an 8 mm sensing-head diameter. Its mounting dimensions and overall installed length should be checked against the manufacturer’s mechanical drawing.

3. What does this sensor measure?

It measures the distance between the probe tip and a conductive metallic target. In rotating machinery applications, this can be used to monitor radial shaft vibration, axial displacement, and shaft position.

4. What is the measurement range?

The PR6423/005 configuration is specified with a linear measurement range of approximately 0–5 mm. The actual usable range depends on the complete probe configuration and correct installation.

5. Does the probe require physical contact with the shaft?

No. It uses eddy-current technology to measure displacement without touching the monitored metallic surface.

6. What target material should be used?

The system is intended for conductive metallic targets. Ferromagnetic steel is a typical specified target material. The target’s material properties and geometry should be considered during calibration and installation.

7. What is the function of the ZW0502 converter?

The converter processes the signal from the eddy-current probe and provides a suitable measurement output for compatible monitoring equipment. It must be matched with the probe and associated cables.

8. Can the system be used for turbine monitoring?

Yes. Eddy-current displacement systems are commonly used for turbine shaft vibration and position monitoring. The installation must follow the turbine’s measurement-point design and the requirements of the machinery protection system.

9. Can this sensor connect directly to a PLC?

The probe should not be treated as a conventional direct-wired PLC sensor. It requires compatible measurement electronics. The converter or monitoring system provides the appropriate signal interface, which must be checked before PLC integration.

10. What should be checked before replacing an existing probe?

Verify the complete model number, probe diameter, mounting thread, measurement range, sensitivity, cable length, connector, target material, converter compatibility, and initial air gap. Matching only the probe diameter is insufficient.

Procurement and Maintenance Recommendations

When purchasing the Epro ZW0502/1217/0211 + PR6423/005-0F2, verify whether the supplied package includes only the probe or the complete probe-and-converter configuration. The product designation contains two model identifiers, and the included components should be clearly stated on the quotation and packing list.

For replacement projects, compare the complete probe and converter model numbers with the installed equipment. Check the cable length, connector arrangement, mounting thread, measurement range, and target material. These details are essential for maintaining measurement accuracy.

For used or surplus equipment, request clear photographs of the probe label, connector, cable, and converter. Inspect the probe tip and cable for mechanical damage. Confirm the condition of the converter terminals and housing before installation.

During maintenance, check the probe mounting, cable condition, connector security, and signal stability. Keep the probe tip clean and avoid mechanical damage during removal or installation. Recheck the initial air gap and measurement scaling after replacement.

For critical rotating machinery, preserve the original measurement settings and installation records. Changes to probe position, converter configuration, or target geometry may affect the measurement baseline and alarm interpretation.

Conclusion

The Epro ZW0502/1217/0211 + PR6423/005-0F2 is an 8 mm eddy-current displacement measurement configuration designed for non-contact monitoring of rotating machinery. Its PR6423 probe measures static and dynamic displacement of conductive metallic targets, while the associated converter processes the measurement signal for use with compatible monitoring equipment.

With applications in turbines, compressors, pumps, and other industrial rotating machinery, this system can contribute to shaft vibration and position monitoring. Accurate probe installation, correct converter matching, suitable target material, and proper calibration are essential for reliable operation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501