Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Ingersoll Rand 80060239 Coolant is a compressor coolant used in compatible Ingersoll Rand compressed-air systems. It forms part of the compressor lubrication and thermal-management circuit, helping the compression system operate within its intended temperature range while reducing friction and wear between moving components.
In an oil-lubricated screw compressor, coolant circulates through the compression and cooling system as the compressor operates. It absorbs heat generated during compression and helps maintain suitable lubrication conditions for the airend and associated components.
The coolant is particularly relevant during routine compressor servicing. Maintaining the correct coolant condition and replacement interval helps prevent excessive thermal loading, lubricant degradation, and operating problems associated with contaminated or deteriorated compressor fluid.
For maintenance teams, the 80060239 should be selected according to the compressor model and manufacturer requirements. Coolant condition, contamination, operating temperature, and service history should be considered when planning replacement or replenishment.
| Parameter | Specification |
|---|---|
| Manufacturer | Ingersoll Rand |
| Part Number | 80060239 |
| Product Number | 47667845001 |
| Product Type | Compressor Coolant |
| Primary Function | Compressor lubrication and heat management |
| System Role | Lubrication and thermal-management medium |
| Application | Oil-lubricated compressor systems |
| Capacity | 15 L |
| Weight | 15 kg |
During compressor operation, the coolant circulates through the lubrication and cooling circuit. In an oil-injected screw compressor, fluid is introduced into the compression process to provide lubrication and absorb heat generated as air is compressed.
After leaving the compression stage, the coolant and compressed-air mixture passes through the air/oil separation system. The separated coolant is then routed through the cooling and filtration circuit before being returned to the compressor.
Compressor Airend → Coolant / Air Mixture → Air/Oil Separator → Coolant Circuit → Cooler / Filter → Compressor Airend
The condition of the coolant directly affects heat transfer, lubrication, and the overall condition of components exposed to the circulating fluid. Contamination, oxidation, or deterioration can reduce its ability to perform these functions and may contribute to elevated operating temperatures or increased component wear.
The 80060239 Coolant operates as part of the compressor’s fluid-management circuit rather than as an independent mechanical component. It works together with the airend, separator, cooler, filter, and oil-return system.
Compressor Airend → Air/Oil Separator → Coolant Cooler → Coolant Filter → Compressor Airend
| System Element | Function |
|---|---|
| Compressor Airend | Compresses air and generates operating heat |
| 80060239 Coolant | Lubricates components and absorbs compression heat |
| Air/Oil Separator | Separates coolant from compressed air |
| Coolant Cooler | Removes heat from circulating coolant |
| Coolant Filter | Removes contaminants from the fluid circuit |
| Oil Return System | Returns separated coolant to the compressor |
| Compressor Controller | Monitors and manages compressor operation |
| Application | Typical Use |
|---|---|
| Industrial Screw Compressors | Compressor lubrication and cooling |
| Manufacturing Plants | Maintaining compressed-air compressor operation |
| Process Air Systems | Supporting continuous compressor service |
| Plant Utility Systems | Compressor coolant replacement and maintenance |
| Packaging Facilities | Maintaining compressed-air equipment |
| Workshop Compressor Systems | Routine compressor fluid servicing |
| Compressor Service Operations | Coolant replacement and system maintenance |
| OEM Compressor Packages | Fluid maintenance for compatible equipment |
| Component | Function |
|---|---|
| Ingersoll Rand Compressor | Uses the coolant within the lubrication circuit |
| Screw Compression Element | Compresses air and generates operating heat |
| Air/Oil Separator | Separates coolant from compressed air |
| Coolant Filter | Removes contaminants from circulating coolant |
| Coolant Cooler | Transfers heat away from the coolant |
| Oil Return Line | Returns separated coolant to the compressor |
| Thermostatic Valve | Regulates coolant flow according to temperature |
| Compressor Controller | Monitors compressor operating conditions |
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| Ingersoll Rand 80060239 | Compressor Coolant | Compressor lubrication and cooling |
| Ingersoll Rand 54601513 | Air/Oil Separator Element | Air/oil separation in screw compressors |
| Ingersoll Rand 39911631 | Oil Filter | Compressor coolant filtration |
| Ingersoll Rand 47638842001 | Air Filter Main Core | Compressor intake air filtration |
| Ingersoll Rand 47638843001 | Air Filter Safety Filter | Secondary intake air filtration |
| Ingersoll Rand Compressor Coolants | Compressor Fluid Family | Compressor lubrication and heat control |
| Ingersoll Rand Compressor Filters | Filter Components | Compressor fluid and air filtration |
80060239 serves as compressor coolant within the lubrication and cooling circuit. In compatible systems, it helps lubricate moving components while carrying heat away from the compression process.
Elevated operating temperature, abnormal coolant condition, contamination, unusual deposits, or changes in compressor operating behavior can indicate that the coolant circuit requires inspection. The compressor’s maintenance documentation should determine the appropriate replacement interval.
A restricted filter can reduce fluid circulation, while a contaminated cooler can reduce heat-transfer performance. Checking both components helps ensure that fresh coolant can circulate effectively through the compressor system.
Verify the coolant level, inspect the system for leaks, confirm circulation, and monitor operating temperature and pressure after startup. Any abnormal condition should be investigated before the compressor returns to normal service.