The Epro PR6426/000-030+CON021/916-200 32 mm Eddy Current Sensor is a non-contact displacement measurement assembly designed for monitoring the movement and position of rotating machinery shafts. It combines a PR6426 eddy current sensor with a CON021 signal converter configured for an extended measurement range.
Manufactured under the Epro machinery monitoring product family, now associated with Emerson’s machinery health solutions, this sensor assembly is intended for applications where accurate shaft-position information is important to equipment condition monitoring and operational protection.
The system is designed to measure radial and axial shaft displacement, including shaft position, eccentricity, and dynamic movement. Unlike contact-based measurement devices, an eddy current sensor does not need to touch the rotating target. It operates by detecting changes in the electromagnetic field produced between the probe and a suitable conductive target.
The PR6426 sensor has a 32 mm sensor head diameter and is designed for large rotating machinery. Its standard sensor specification includes a static measurement range of ±4.0 mm, nominal sensitivity of 2 V/mm, and maximum linearity error of ±1.5%. The associated CON021/916-200 converter provides a 20 mm extended-range measurement configuration. The performance of the complete measuring chain must be considered when selecting and commissioning the assembly.
Typical applications include steam turbines, gas turbines, hydro turbines, compressors, pumps, and industrial fans. In these machines, shaft displacement measurements can help operators and maintenance engineers identify changes in mechanical condition before they develop into serious equipment problems.
The PR6426/000-030+CON021/916-200 is therefore relevant to machinery protection systems, vibration monitoring installations, and industrial condition-monitoring projects where reliable non-contact shaft measurement is required.
| Parameter | Specification |
|---|---|
| Brand | Epro |
| Manufacturer / Product Family | Emerson Epro |
| Model | PR6426/000-030+CON021/916-200 |
| Product Type | Eddy Current Sensor Assembly |
| Sensor Model | PR6426/000-030 |
| Signal Converter | CON021/916-200 |
| Sensor Head Diameter | 32 mm |
| Measurement Principle | Non-contact eddy current |
| Standard PR6426 Static Range | ±4.0 mm |
| CON021 Converter Configuration | 20 mm extended-range version |
| PR6426 Nominal Sensitivity | 2 V/mm |
| PR6426 Maximum Linearity Error | ±1.5% |
| Nominal Center Air Gap | Approximately 5.5 mm |
| Long-Term Drift | Less than 0.3% |
| Standard Target Material | Ferromagnetic steel |
| Recommended Shaft Diameter | Greater than 200 mm |
| Sensor Operating Temperature | -35 to +175°C |
| Short-Term Temperature Excursion | Up to 200°C for less than 4 hours |
| Sensor Sleeve Material | Stainless steel |
| Cable Material | PTFE |
| Cable Diameter | 2.8 mm |
| Sensor Mounting Plate | 80 × 40 mm |
| Dimensions | Not supplied as a single overall assembly dimension |
| Weight Provided | 0.92 kg |
| Typical Applications | Turbines, compressors, pumps, and fans |
Important: The ±4.0 mm range and 2 V/mm sensitivity describe the standard PR6426 sensor specification. The CON021/916-200 is a 20 mm extended-range converter configuration. Do not use the sensor-only figures as the complete measuring-chain calibration data.
The PR6426 uses the eddy current principle to measure the distance between the sensor head and a conductive target, typically a rotating steel shaft. The sensor generates an electromagnetic field, and the electrical characteristics of that field change as the distance to the target changes.
The associated converter processes the sensor signal and provides an output suitable for monitoring and control equipment.
When the sensor is installed near a rotating shaft, it establishes a controlled measurement gap between the probe tip and the shaft surface.
As the shaft moves toward or away from the sensor, the electromagnetic response changes. The sensor and converter system translates this change into a measurement signal representing the displacement of the target.
Because the sensor does not physically contact the shaft, it can monitor continuous movement without introducing mechanical friction at the measurement point.
This principle is particularly useful in high-speed rotating machinery, where contact-based measurement could introduce wear or interfere with normal operation.
Shaft position is an important parameter in many large rotating machines. Changes in the shaft’s position may indicate bearing wear, changes in operating conditions, thermal expansion, or mechanical alignment problems.
The PR6426 can be installed to measure radial or axial shaft movement, depending on the mechanical arrangement and monitoring objective.
For example, an axial measurement installation can help track the movement of a turbine rotor relative to its reference position. Radial measurements can provide information about shaft movement within the bearing assembly.
Shaft eccentricity describes the difference between the geometric center of a shaft and its actual rotational behavior. Excessive eccentricity can contribute to vibration, uneven mechanical loading, and increased bearing stress.
The PR6426 can provide displacement information that helps monitoring equipment evaluate shaft movement and eccentricity.
When used with an appropriate monitoring system, the measured signal can support the identification of abnormal operating patterns and changes in rotating machinery condition.
The CON021/916-200 component is the signal converter associated with this assembly. It processes the sensor signal and provides the corresponding measuring-chain output.
Its 20 mm extended-range configuration is intended for measurement applications requiring a wider displacement range than the standard PR6426 sensor range alone.
The converter and sensor must be treated as a matched measurement chain. Using an incorrect converter, incompatible sensor, or mismatched calibration can result in inaccurate readings.
The sensor assembly can be incorporated into a machinery monitoring system to provide ongoing shaft-displacement information.
Depending on the monitoring architecture, measured signals may be used for:
The sensor provides measurement information; the interpretation, alarm logic, and shutdown decisions are handled by the connected monitoring and control system.
The PR6426/000-030+CON021/916-200 is intended to operate as part of a wider machinery condition-monitoring arrangement. Its main role is to convert mechanical shaft movement into an electrical measurement signal that can be evaluated by monitoring equipment.
Steam, gas, and hydro turbines contain rotating shafts that operate under demanding mechanical and thermal conditions. Monitoring shaft position and displacement helps engineers understand changes in rotor behavior.
The PR6426’s 32 mm sensor head is designed for large-shaft measurement applications. It can be used in suitable turbine monitoring installations where its measurement range, target geometry, and environmental ratings meet the project requirements.
Industrial compressors may operate continuously and experience changing loads, temperatures, and operating speeds. Shaft movement measurements can help identify abnormal mechanical conditions.
A properly installed eddy current sensor can provide continuous displacement information for use by the compressor monitoring system.
Large industrial pumps are used in water treatment, oil and gas processing, chemical production, and power generation. Changes in shaft movement may indicate mechanical wear, bearing problems, or alignment changes.
The PR6426 can be considered for pump monitoring applications where its large sensor head and measurement characteristics are appropriate.
Large fans and blowers often operate for extended periods. Shaft displacement measurements can contribute to the monitoring of rotating assemblies and help maintenance personnel assess changes in mechanical condition.
The sensor must be installed at a suitable measurement location with appropriate clearance from surrounding ferrous materials.
Steam turbines operate at high rotational speeds and under demanding thermal conditions. Monitoring axial and radial shaft displacement is important for evaluating rotor position and mechanical stability.
The PR6426 can provide non-contact displacement measurements when installed with a suitable converter and monitoring arrangement.
Gas turbines are used in power generation and industrial process applications. Their rotating assemblies require continuous monitoring to support reliable operation.
The sensor can be used to measure shaft movement and position in suitable large-shaft installations.
Hydro turbines operate with large rotating components and may experience changes in mechanical loading and operating conditions.
Shaft-position monitoring can help maintenance teams evaluate rotor movement and identify changes that require further inspection.
Compressors used in refineries, petrochemical facilities, and gas-processing plants often operate as critical production assets.
Non-contact displacement monitoring can provide information about shaft movement and contribute to machinery protection strategies.
Pumps used in power stations, water facilities, and industrial processing plants may require continuous monitoring of rotating components.
The PR6426 can be used where the shaft diameter, target material, measurement range, and installation geometry are compatible with its specifications.
Large ventilation and process-air systems depend on stable rotating machinery operation. Shaft displacement monitoring can help identify mechanical changes that may affect equipment reliability.
The sensor should be installed in a location that provides a stable target surface and sufficient clearance around the probe.
Correct installation is essential for measurement accuracy and long-term reliability. Eddy current sensors are sensitive to probe position, target material, installation geometry, and cable routing.
Before installation, confirm that the PR6426/000-030 sensor is paired with the specified CON021/916-200 converter.
The converter’s extended measurement configuration is an important part of the complete assembly. A different converter model may have a different measuring range, sensitivity, output characteristic, or electrical interface.
Do not substitute a converter based only on physical appearance or connector compatibility.
The PR6426 is designed to measure ferromagnetic steel targets. The manufacturer’s standard target material is 42CrMo4 steel.
The shaft surface should be suitable for eddy current measurement. Surface condition, material properties, geometry, and nearby metallic structures can influence the measurement.
The standard PR6426 specification identifies a shaft diameter greater than 200 mm. Confirm the target geometry and required measurement area before installation.
The standard PR6426 sensor specification gives a nominal center air gap of approximately 5.5 mm.
The actual setup must follow the applicable sensor and converter instructions. Correct probe positioning is necessary to maintain the intended measurement range and output characteristics.
An incorrect air gap can cause inaccurate readings or place the sensor outside its specified linear operating region.
The sensor head has a diameter of 32 mm and uses an 80 × 40 mm mounting plate configuration.
The manufacturer’s mechanical drawing identifies an 80 mm diameter clearance area free of ferrous material around the sensor. This requirement helps prevent nearby metal from affecting the electromagnetic measurement field.
The mounting arrangement should also provide sufficient space for the cable and connector.
The PR6426 uses a PTFE cable with a nominal diameter of 2.8 mm. The manufacturer’s drawing specifies a minimum bending radius of 25 mm for non-armored cable and 35 mm for armored cable.
Avoid sharp bends, excessive tension, crushing, or contact with moving mechanical components.
Cable routing should minimize exposure to electrical interference and excessive mechanical vibration.
The sensor cable must be connected to the compatible CON021 converter using the correct connector and installation procedure.
The converter should be mounted in an appropriate location where it is protected from environmental conditions beyond its specified ratings.
Verify the converter’s supply voltage, terminal assignments, grounding, and output connections using its own technical documentation.
After installation, connect the converter output to the intended machinery monitoring or protection equipment.
Configure the correct measurement range, calibration, alarm thresholds, and signal scaling. The system should be tested against known mechanical or calibration references before being placed into normal operation.
The PR6426/000-030+CON021/916-200 assembly is part of a measurement chain. Its operation depends on the correct combination of sensor, converter, cabling, and monitoring equipment.
| Component | Function | Compatibility Considerations |
|---|---|---|
| PR6426/000-030 sensor | Detects shaft displacement without contact | Must match the specified converter configuration |
| CON021/916-200 converter | Processes the sensor signal | 20 mm extended-range configuration; verify calibration and electrical requirements |
| Sensor cable | Transfers the probe signal to the converter | Confirm cable length, connector, and protection type |
| LEMO connector and adapter | Provides the sensor-side connection arrangement | Verify connector configuration before replacement |
| Machinery monitoring system | Receives and evaluates measurement signals | Confirm input range, signal scaling, and channel configuration |
| Shaft target | Provides the conductive measurement surface | Use a suitable ferromagnetic steel target |
| Sensor mounting plate | Holds the probe in its measurement position | Maintain the specified mounting geometry and clearance |
| Control or protection system | Processes alarms and operating conditions | Configure alarm and trip logic according to the machinery protection design |
The components listed above describe the measurement arrangement. They should not be assumed to be included in every supplier’s product package.
The PR6426 belongs to the Epro PR642x eddy current sensor family. Other models may be available for different shaft sizes, measuring ranges, or installation arrangements.
| Model or Product | Description | Replacement Considerations |
|---|---|---|
| PR6426/000-030 | 32 mm eddy current sensor | Sensor component of the specified assembly; converter must be matched |
| PR6426 with CON021/916-120 | 32 mm sensor with 12 mm extended-range converter | Different converter range; verify measurement requirements |
| PR6426 with CON021/916-160 | 32 mm sensor with 16 mm extended-range converter | Not equivalent to the 20 mm configuration |
| PR6426 with CON021/916-200 | 32 mm sensor with 20 mm extended-range converter | Same converter range configuration as the specified assembly |
| PR6425 sensor family | Eddy current sensor for other shaft measurement applications | Different probe dimensions and measurement characteristics |
| PR6424 sensor family | Smaller eddy current sensor configuration | Not a direct substitute for a 32 mm PR6426 installation |
Before replacing the assembly, compare:
A replacement sensor that fits the mounting location may still be electrically incompatible with the existing converter. Always verify the complete measurement chain.
The eddy current principle allows shaft displacement to be measured without physical contact between the sensor and the rotating target. This avoids mechanical contact wear at the sensing point.
The 32 mm PR6426 sensor head is intended for large-shaft measurement applications, including turbines, compressors, pumps, and fans.
The CON021/916-200 converter provides a 20 mm extended-range configuration, supporting applications that require a wider measurement range than the standard PR6426 sensor specification alone.
The PR6426 sensor specification identifies an operating temperature range of -35 to +175°C, with short-term temperature excursions up to 200°C for less than four hours. Actual installation limits must be checked against the complete assembly and cable arrangement.
The standard PR6426 specification identifies sensitivity of 2 V/mm, maximum linearity error of ±1.5%, and long-term drift below 0.3%.
These figures apply to the standard sensor specification; the complete measuring-chain performance must be confirmed using the corresponding converter documentation.
The sensor can provide displacement information to machinery monitoring equipment, helping operators assess shaft position and identify changes in rotating equipment behavior.
The assembly is intended for use in several types of large rotating machinery, including steam turbines, gas turbines, hydro turbines, compressors, pumps, and fans.
It is a non-contact eddy current displacement measurement assembly consisting of a 32 mm PR6426 sensor and a CON021/916-200 signal converter.
The 32 mm value refers to the diameter of the PR6426 sensor head. It is not the diameter of the complete sensor assembly or the mounting plate.
The standard PR6426 specification identifies a static measurement range of ±4.0 mm. The specified CON021/916-200 converter is a 20 mm extended-range configuration, so the complete measuring-chain range must be interpreted using the matched converter documentation.
The standard PR6426 sensor specification gives a nominal sensitivity of 2 V/mm, with a maximum linearity error of ±1.5%.
The standard target material is ferromagnetic steel, with 42CrMo4 identified as the reference material. Other target materials may require separate evaluation and calibration.
The PR6426 sensor specification identifies an operating range of -35 to +175°C. It also permits short-term temperature excursions up to 200°C for less than four hours. Check the converter and complete assembly limits separately.
No. It uses the eddy current principle to measure the distance between the sensor head and a conductive target without physical contact.
Typical applications include steam turbines, gas turbines, hydro turbines, compressors, pumps, and fans. The shaft size, target material, measurement range, and installation geometry must meet the sensor requirements.
Not automatically. The converter must match the sensor’s electrical characteristics and required measurement range. Using an incompatible converter can result in incorrect measurement scaling or unreliable operation.
Confirm the complete model number, sensor head diameter, converter configuration, cable length, connector type, mounting arrangement, and measurement range. Also verify the physical condition of the sensor cable and probe head.
When sourcing the Epro PR6426/000-030+CON021/916-200, verify that the supplied package includes the correct PR6426 sensor and CON021/916-200 converter configuration. Some listings may describe the sensor head separately from the complete measurement assembly, so the package contents should be confirmed before ordering.
The converter model is particularly important. The CON021/916-200 is configured for a 20 mm extended measurement range. A similar-looking CON021 converter with a different suffix may have a different measuring range or calibration characteristic.
For replacement projects, compare the existing installation’s probe dimensions, mounting plate, cable length, connector arrangement, and monitoring-system input requirements. Confirm whether the sensor is supplied with an armored or non-armored cable and whether the required adapter plug is included.
During maintenance, inspect the sensor head for mechanical damage and check the cable for cuts, crushing, excessive bending, or connector contamination. Verify the mounting condition and ensure that nearby metallic structures do not violate the required clearance.
The monitoring system should be checked periodically to confirm that the measurement signal remains consistent with the expected calibration and operating conditions. Alarm limits should be reviewed against the machinery manufacturer’s requirements and the site’s protection strategy.
For critical turbine and compressor applications, sensor replacement should be followed by appropriate calibration and functional testing. Correct installation and configuration are essential for dependable shaft-displacement monitoring.
The Epro PR6426/000-030+CON021/916-200 32 mm Eddy Current Sensor is a non-contact measurement assembly designed for shaft-position and displacement monitoring in large rotating machinery. Combining the PR6426 sensor with the CON021/916-200 extended-range converter, it supports measurement applications involving turbines, compressors, pumps, and industrial fans.
The standard PR6426 sensor specification includes a 32 mm head diameter, ±4.0 mm static range, 2 V/mm sensitivity, and a maximum linearity error of ±1.5%. The associated converter provides a 20 mm extended-range configuration, making correct sensor-converter matching essential.
For industrial maintenance, machinery protection, and replacement projects, the complete model number and measurement-chain configuration should always be verified. Proper mounting, cable routing, target preparation, and calibration help maintain reliable measurement performance throughout the equipment’s service life.