Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The 330180-X1-R0 is a precision proximity transducer system based on eddy current measurement technology. It is designed for continuous, non-contact monitoring of shaft vibration, displacement, and rotor position in high-speed rotating machinery.
The system is widely applied in machinery protection and condition monitoring environments where accurate real-time displacement measurement is required to prevent mechanical failure and ensure stable operation.
It operates by detecting changes in the electromagnetic field between the probe and a conductive target surface, converting these changes into a proportional electrical signal for monitoring systems.
(Manufacturer name intentionally removed as requested)
This series is widely used in industrial monitoring systems due to its stability, accuracy, and long service life under harsh operating conditions.
The 330180-X1-R0 is suitable for a wide range of heavy industrial applications, including:
| Parameter | Specification |
|---|---|
| Operating voltage | 24 V DC |
| Output signal type | Analog voltage signal |
| Signal technology | Eddy current induction |
| Output impedance | 50–100 Ω |
| Frequency response | Up to 10 kHz |
| Signal stability | High long-term stability |
| Parameter | Specification |
|---|---|
| Measurement range | 0 – 5 mm (typical linear range) |
| Resolution | ≤ 1 μm |
| Accuracy | ±0.25% – ±0.5% full scale |
| Linearity | High linear response within calibrated region |
| Repeatability | Excellent under stable operating conditions |
| Parameter | Specification |
|---|---|
| Operating temperature | -40°C to +121°C |
| Storage temperature | -55°C to +125°C |
| Humidity range | 5% – 95% non-condensing |
| Vibration resistance | Up to 20 g depending on installation |
| EMI protection | High electromagnetic interference shielding |
| Parameter | Specification |
|---|---|
| Signal conditioner dimensions | 100 mm × 160 mm × 50 mm |
| Probe material | Stainless steel housing |
| Cable type | Shielded coaxial cable |
| Cable length options | 3 m / 5 m / 9 m |
| Total system weight | ~2.0 kg |
| Probe weight | ~0.08 kg |
| Mounting type | Panel / rack installation |
The system operates using eddy current electromagnetic induction:
This enables highly accurate non-contact displacement measurement at micrometer level resolution.
| Parameter | 330180-X1-R0 | 330180-X1-05 | 330180-X1-R0 143416-22 | 330180-X1-R0 145004-33 | 330180-X1-R0 145004-41 |
|---|---|---|---|---|---|
| Measurement type | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 0–5 mm | 0–2 mm | 0–5 mm | 0–5 mm | 0–5 mm |
| Accuracy | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS |
| Dimensions | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm |
| Weight (kg) | 2.0 kg | 2.0 kg | 2.0 kg | 2.0 kg | 2.0 kg |
| Parameter | 330780-93-00 | 330881-28-12-110-02-02 | 330103-00-08-10-02-00 | 330106-05-45-10-02-00 | 330104-00-08-10-02-00 |
|---|---|---|---|---|---|
| System type | Proximity probe | Signal conditioner | Proximity probe | Proximity probe | Proximity probe |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency range | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 2–5 mm | 2–5 mm | 2–5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 90×140×40 mm | 110×170×55 mm | 85×130×35 mm | 85×130×35 mm | 85×130×35 mm |
| Weight (kg) | 1.6 kg | 2.3 kg | 1.2 kg | 1.2 kg | 1.2 kg |
| Parameter | 330901-00-15-10-02-05 | 330905-00-14-10-02-00 | 330909-00-35-10-02-05 | 330910-00-14-10-02-00 | 330930-00-07-10-02-00 |
|---|---|---|---|---|---|
| Product type | Proximity probe | Signal module | High sensitivity probe | Vibration probe | Industrial probe unit |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 7 mm | 5 mm | 5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.25% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 95×150×45 mm | 120×180×60 mm | 100×160×50 mm | 95×150×45 mm | 90×140×40 mm |
| Weight (kg) | 1.8 kg | 2.5 kg | 2.1 kg | 1.7 kg | 1.5 kg |
The 330180-X1-R0 is a high-precision eddy current proximity transducer system designed for continuous monitoring of rotating machinery. It provides excellent accuracy, strong environmental resistance, and long-term operational stability.
Its modular structure and compatibility with industrial monitoring systems make it a reliable solution for turbine, compressor, and heavy machinery protection applications.