Product Overview The GE IC200ALG260A VersaMax Analog Input Module is an industrial automation component designed to collect analog signals from field instruments and transmit measurement data to a progr……
GE IC200ALG260A Analog Input Module
  • GE
  • IC200ALG260A
  • Analog Input Module
  • USA
  • 110 x 66.8 x 50 mm
  • 0.25 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

GE IC200ALG260A Analog Input Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IC200ALG260A Analog Input Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IC200ALG260A Analog Input Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IC200ALG260A Analog Input Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IC200ALG260A VersaMax Analog Input Module is an industrial automation component designed to collect analog signals from field instruments and transmit measurement data to a programmable logic controller (PLC). It belongs to the GE Fanuc VersaMax distributed I/O platform and provides an interface between industrial sensors, transmitters, and the control system.

In industrial processes, many important operating variables are measured through analog signals. Pressure transmitters, temperature measurement instruments, flow sensors, and other field devices commonly provide standard voltage or current signals. The IC200ALG260A receives these signals and converts them into digital data that can be processed by a VersaMax PLC or network interface unit.

This module provides eight single-ended analog input channels and supports both voltage and current input operation. Its supported signal ranges include 4–20 mA current, 0–10 V DC voltage, and ±10 V DC voltage. The input mode and range are configured through the appropriate carrier jumper settings.

With 12-bit input resolution, the IC200ALG260A is designed for general industrial measurement and monitoring applications. It can be used to acquire process information from multiple field devices through one compact I/O module, helping reduce the need for separate input modules for different measurement points.

The module receives its operating power from the VersaMax backplane and does not require a separate external power supply for normal module operation. Its LED indicators provide basic information about internal field-side power and backplane power status.

The IC200ALG260A is suitable for applications where PLC systems need to monitor analog process variables and use those measurements in control logic, alarms, sequencing, and process supervision.

Technical Specifications

Parameter Specification
Brand GE Fanuc
Manufacturer GE / Emerson Automation
Model IC200ALG260A
Product Series VersaMax
Product Type Analog Input Module
Input Channels 8 single-ended channels
Resolution 12-bit
Input Signal Type Voltage and current
Current Input Range 4–20 mA
Voltage Input Range 0–10 V DC / ±10 V DC
Input Configuration Single-ended, common return
Input Impedance – Voltage Mode 126 kΩ maximum
Input Impedance – Current Mode 200 Ω maximum
Typical Accuracy at 25°C ±0.3% of full scale
Maximum Accuracy at 25°C ±0.5% of full scale
Input Filter Response 5.0 ms
Module Update Rate 0.4 ms
Backplane Current Consumption 130 mA maximum at 5 V
External Power Supply Not required for module operation
Isolation 250 V AC continuous; 1500 V AC for 1 minute
LED Indicators INT PWR and OK
Configuration Range and mode selection through carrier jumpers
Diagnostics Loss of internal power
Dimensions Provided 110 × 66.8 × 50 mm
Weight Provided 0.25 kg
Platform GE Fanuc VersaMax PLC and distributed I/O

Note: Dimensions refer to the module body and exclude the height of the carrier and mating connectors. Verify the exact revision and carrier configuration before installation.

Function and Working Principle

The primary function of the IC200ALG260A is to receive analog signals from field devices, convert the measured values into digital data, and make the information available to the PLC control system.

1. Analog Signal Acquisition

Industrial sensors and transmitters measure physical variables such as pressure, temperature, flow, and liquid level. Their outputs are often represented by standard voltage or current signals.

The IC200ALG260A accepts up to eight single-ended analog inputs. This allows several field measurement devices to be connected to one module, provided their signal types and ranges are compatible with the configured input channels.

For example, a process installation may use separate transmitters to monitor pressure at different points in a pipeline. The module collects the analog signals and makes the resulting measurements available to the PLC.

2. Voltage Input Processing

In voltage mode, the module supports bipolar and unipolar voltage ranges.

The bipolar range is ±10 V DC, while the unipolar range is 0–10 V DC. The selected range must correspond to the connected instrument’s output signal.

Voltage inputs are measured relative to the common return. Correct wiring and signal grounding are important for maintaining measurement stability and reducing interference.

3. Current Input Processing

The module also supports 4–20 mA current signals, which are widely used in industrial instrumentation.

A 4–20 mA transmitter represents a measured process variable through a current signal. For example, a pressure transmitter may use 4 mA to represent the lower measurement limit and 20 mA to represent the upper measurement limit.

The IC200ALG260A receives the current signal and converts it into digital information for PLC processing. The control program can then scale the input data into engineering units such as bar, °C, liters per minute, or percentage.

4. Analog-to-Digital Conversion

The module uses 12-bit resolution to represent the analog input measurement as digital data.

The PLC can use these values for calculations, comparisons, alarms, and control decisions. The module provides eight words of analog input data to the control system.

The actual measurement accuracy depends on the input range, field wiring, transmitter performance, environmental conditions, and system configuration.

5. Input Filtering and Update Rate

The module has a 5 ms input filter response and a 0.4 ms module update rate.

Input filtering helps reduce the effect of short-duration electrical disturbances and signal fluctuations. The update rate describes how frequently the module updates its input data internally; it should not be confused with the complete response time of the PLC application.

For applications involving rapidly changing signals, engineers should evaluate the complete measurement and control-system response rather than relying on the module update rate alone.

Role in Industrial Control Systems

The IC200ALG260A acts as the analog measurement interface between field instrumentation and the VersaMax control platform.

PLC Process Monitoring

The module supplies analog measurement data to the PLC. The controller can process this information and use it to determine whether equipment is operating within the required limits.

For example, a PLC may monitor pressure readings from several transmitters and activate an alarm if one measurement exceeds a configured threshold.

Process Control

Analog input values can be used as feedback for process-control functions. A PLC may compare the measured value with a target value and adjust a pump, valve, heater, or other actuator through a separate output module or control device.

The IC200ALG260A performs the input acquisition function. It does not directly provide analog output signals to control actuators.

Alarm and Interlock Logic

The digital values received by the controller can be used to trigger alarms and interlocks.

For example, if a pressure transmitter reports a value above a defined operating limit, the PLC can generate an alarm or initiate a programmed protective response.

The reliability of these functions depends on correct transmitter scaling, PLC programming, wiring, and system-level safety design.

Distributed I/O Architecture

The VersaMax platform supports distributed I/O arrangements. The IC200ALG260A can be installed as part of a local or remote I/O configuration, depending on the selected carrier, power supply, CPU, and network interface architecture.

This allows analog measurement points to be integrated into larger automation systems without requiring every field signal to be wired directly to a central controller rack.

Industrial Applications

The IC200ALG260A can be used in industrial systems that require monitoring of standard voltage and current signals.

1. Process Automation

Chemical processing, water treatment, and general manufacturing facilities use analog transmitters to measure operating variables.

The module can acquire signals from compatible pressure, temperature, and flow transmitters. The PLC then uses these measurements for process monitoring, control calculations, and alarm management.

2. Water and Wastewater Treatment

Water treatment systems commonly monitor tank levels, pipeline pressure, flow rates, and other process conditions.

The IC200ALG260A can receive compatible 4–20 mA or voltage signals from field instruments. These measurements can be used by the PLC to coordinate pumps, valves, and treatment equipment.

3. Manufacturing Equipment

Production machinery often contains sensors that monitor temperature, pressure, position, or other process conditions.

The module provides multiple analog input channels for collecting these measurements. The PLC can use the data to monitor equipment operation and coordinate production sequences.

4. Pumping Systems

Industrial pumping installations may use pressure and flow transmitters to monitor operating conditions.

The module can acquire these signals and provide the measurements to the PLC. The control system can then use the data to regulate pump operation through compatible motor drives or output devices.

5. HVAC and Building Utility Systems

Industrial heating, ventilation, and cooling systems use analog sensors to monitor temperature, pressure, and other environmental variables.

The IC200ALG260A can collect compatible sensor signals for centralized monitoring and control through a VersaMax PLC system.

6. Energy and Utility Monitoring

Industrial utility systems may monitor pressure, temperature, and other operating parameters associated with compressed air, steam, cooling water, and process utilities.

The module can provide analog measurements to the PLC for equipment supervision, operating reports, and alarm functions.

Installation and System Integration

Correct installation is necessary to achieve reliable signal acquisition and stable PLC operation.

1. Verify Module and Carrier Compatibility

Before installation, confirm that the IC200ALG260A is compatible with the selected VersaMax carrier and system configuration.

Check the module revision, carrier type, terminal arrangement, and PLC or network interface requirements. The carrier provides the physical connection and field wiring interface for the module.

2. Configure Input Mode and Range

The module supports voltage and current operation. The required mode and voltage range are selected through the appropriate jumpers on the carrier terminals.

The configuration must match the connected field instrument.

  • Current mode: 4–20 mA.
  • Bipolar voltage mode: ±10 V DC.
  • Unipolar voltage mode: 0–10 V DC.

Do not connect a voltage signal to a channel configured for current operation or vice versa. Incorrect configuration can result in inaccurate measurements or abnormal input readings.

3. Connect Field Instruments

Each channel uses a signal connection and a common return arrangement. The field wiring should follow the manufacturer’s terminal assignment.

All eight inputs are single-ended and share a common return. The system should not be treated as having eight independently isolated input channels.

Use appropriate cable shielding and grounding practices, particularly when the module is installed near variable frequency drives, motors, contactors, or other sources of electrical interference.

4. Check Backplane Power

The module receives operating power from the VersaMax backplane and has a maximum 5 V backplane current consumption of 130 mA.

Verify that the system power supply and backplane have sufficient capacity for all installed modules. Although the IC200ALG260A does not require a separate external supply for its own operation, connected field transmitters may require their own power sources.

5. Configure PLC Parameters

The PLC or network interface configuration should identify the installed module and allocate the appropriate input data.

The control program should scale the raw input values into the engineering units used by the application. For current signals, the scaling should correspond to the transmitter’s configured measurement range.

Verify channel assignments carefully to prevent incorrect readings from being associated with the wrong process variable.

6. Commissioning and Testing

After installation, check the following items:

  • Confirm that the module is seated correctly in its carrier.
  • Verify the input-mode and range jumper settings.
  • Inspect terminal connections and common returns.
  • Confirm that field transmitters have the required power.
  • Check the INT PWR and OK LED indicators.
  • Verify that the PLC recognizes the module.
  • Compare PLC readings with a calibrated field instrument.
  • Test alarms and control logic using appropriate commissioning procedures.

These checks help identify wiring, configuration, and scaling problems before the system enters normal operation.

Compatible System Components

The IC200ALG260A is part of a wider VersaMax automation architecture. Its operation depends on compatible mounting, power, controller, and field-wiring components.

Component Function Integration Considerations
VersaMax PLC CPU Processes input data and executes control logic Confirm system compatibility and module configuration
VersaMax Network Interface Unit Connects distributed I/O to a control network Select the appropriate interface for the system architecture
VersaMax I/O Carrier Provides the module mounting and field connection interface Verify carrier type and terminal assignment
VersaMax Power Supply Supplies the required backplane power Check available current capacity
Analog Transmitters Provide voltage or current measurement signals Confirm 4–20 mA or supported voltage ranges
Pressure Sensors Measure process pressure Verify transmitter output and scaling
Temperature Transmitters Provide temperature measurement signals Check signal type and measurement range
Flow Transmitters Supply flow measurement signals Confirm output configuration and engineering units
Control Cabinet Houses the PLC and I/O equipment Provide suitable environmental protection and wiring space
Shielded Signal Cable Connects field instruments to the I/O carrier Apply appropriate shielding and grounding practices

The table describes typical system components. It does not mean that these accessories are included with the IC200ALG260A.

Alternative Models and Replacement Considerations

Several VersaMax analog input modules provide related functions, but their channel counts, input types, resolution, and isolation arrangements may differ.

Model General Description Replacement Considerations
IC200ALG230 4-channel, 12-bit voltage/current analog input module Similar signal types but fewer input channels
IC200ALG260 8-channel, 12-bit voltage/current analog input module Closely related base model; verify revision and configuration
IC200ALG262 8-channel, 15-bit current input module Different input type and resolution
IC200ALG264 15-channel, 15-bit current input module Different channel arrangement and signal characteristics
IC200ALG266 15-channel current input module with enhanced overvoltage protection Check input range, protection, and system compatibility
IC200ALG320 VersaMax analog output family Output function, not a direct input replacement

A replacement should not be selected only because it belongs to the same VersaMax family. Before substitution, compare the number of channels, signal ranges, resolution, electrical isolation, carrier compatibility, backplane current requirements, and PLC configuration.

For an existing IC200ALG260A installation, using the same complete catalog number and a compatible revision is generally the most straightforward approach, subject to hardware and system verification.

Key Advantages

Eight Analog Input Channels

The module provides eight single-ended input channels, allowing several compatible field instruments to share one compact I/O module.

Voltage and Current Signal Support

It supports 4–20 mA current signals and both 0–10 V DC and ±10 V DC voltage ranges, providing flexibility for different industrial transmitters.

12-Bit Resolution

The 12-bit conversion capability allows the PLC to process analog measurements for monitoring, control calculations, and alarm functions.

Backplane-Powered Operation

The module receives its operating power through the VersaMax backplane, avoiding the need for a separate external module power supply.

Diagnostic LED Indicators

The INT PWR and OK indicators provide basic information about internal field-side power and backplane power status.

Compact VersaMax Design

Its compact form factor supports installation in VersaMax I/O systems where panel space and modular expansion are important considerations.

Integration with PLC Control Logic

The module makes analog measurement data available to the controller for process monitoring, equipment supervision, and automated control functions.

Technical FAQs

1. What is the GE IC200ALG260A?

The GE IC200ALG260A is an eight-channel analog input module in the VersaMax distributed I/O family. It receives voltage and current signals from industrial field devices and provides digital measurement data to the PLC.

2. How many input channels does the module provide?

It provides eight single-ended analog input channels arranged in one group.

3. What input signals does the IC200ALG260A support?

It supports 4–20 mA current signals, ±10 V DC bipolar voltage signals, and 0–10 V DC unipolar voltage signals.

4. What is the resolution of the module?

The module has 12-bit analog input resolution.

5. Does the module require an external power supply?

No separate external power supply is required for normal module operation. It receives power from the VersaMax backplane. Connected field transmitters may require external power depending on their design.

6. What is the module update rate?

The specified module update rate is 0.4 ms. Its input filter response is 5 ms. These values describe different aspects of module operation and should not be treated as the total response time of the complete PLC control loop.

7. Are the eight input channels individually isolated?

No. The inputs are single-ended and share a common return. The module provides optical isolation between the user input circuitry and logic/frame ground, but it does not provide channel-to-channel isolation.

8. How is the input range configured?

The voltage/current mode and voltage range are configured through the appropriate jumpers on the carrier terminals. The jumper settings must match the connected field signals.

9. What do the LED indicators mean?

The INT PWR LED indicates the presence of internally generated field-side power. The OK LED indicates that backplane power is available to the module.

10. Can the IC200ALG260A be used for pressure and flow transmitters?

Yes. It can receive compatible 4–20 mA or voltage signals from pressure and flow transmitters. The transmitter output range and PLC scaling must be configured correctly.

11. What should be checked before replacing the module?

Check the complete catalog number, hardware revision, carrier compatibility, input ranges, channel count, wiring arrangement, and PLC configuration. Also verify the physical condition of the terminals and module connector.

12. What are the dimensions and weight?

The supplied product dimensions are 110 × 66.8 × 50 mm, and the listed weight is 0.25 kg. The dimensions exclude the carrier and mating connectors.

Procurement and Maintenance Recommendations

When purchasing the GE IC200ALG260A, verify the complete catalog number and revision printed on the module label. The base model and revision suffix should be checked carefully to avoid receiving a different hardware version.

For new, surplus, or refurbished modules, request clear photographs of the product label, front panel, connector area, and terminal interface. Confirm the product’s condition, test status, warranty terms, and availability of compatible carriers.

During installation, verify the jumper configuration, field wiring, common returns, and backplane power capacity. Incorrect input-mode settings can produce unreliable readings even when the module itself is operating normally.

For ongoing maintenance, periodically inspect the module seating, carrier terminals, signal wiring, and cabinet environment. Check the INT PWR and OK indicators during troubleshooting and compare important analog readings with calibrated field instruments.

Keep a record of the installed module revision, channel assignments, input ranges, and PLC scaling parameters. This information helps reduce commissioning time when a module needs to be replaced.

Conclusion

The GE IC200ALG260A VersaMax Analog Input Module provides eight 12-bit analog input channels for collecting voltage and current signals in industrial automation systems. Supporting 4–20 mA, 0–10 V DC, and ±10 V DC inputs, it enables compatible field instruments to provide process measurements to a VersaMax PLC.

With backplane-powered operation, configurable input ranges, diagnostic LED indicators, and a compact modular design, the IC200ALG260A can support a variety of process-monitoring and machine-control applications.

For replacement and maintenance projects, it is important to verify the complete model number, revision, carrier compatibility, wiring configuration, and input signal requirements before installation.