Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Allen-Bradley 20F1AND248JA0NNNNN PowerFlex 753 AC Drive is a high-power industrial variable frequency drive designed to provide adjustable-speed control for large three-phase AC motors. Manufactured by Rockwell Automation, the PowerFlex 753 series is used in industrial automation systems that require reliable motor operation, flexible control interfaces, and integration with plant-level control equipment.
The PowerFlex 753 family is designed for general-purpose industrial applications. Its embedded I/O supports machine-level control requirements, while its configurable architecture allows engineers to select drive options according to the motor and application. The series is commonly considered for material handling, pumping, ventilation, processing machinery, and other applications involving substantial motor loads.
The 20F1AND248JA0NNNNN is a 480 V AC, three-phase drive with a rated output current of 248 A. Its published power ratings are 200 HP for normal-duty operation and 150 HP for heavy-duty operation. It uses a Frame 6 construction and forced-air cooling.
This catalog configuration includes an AC input with precharge, embedded I/O, standard protection, an EMC filter with the common-mode jumper installed, and a dynamic braking transistor. It has an IP20/IP00, NEMA/UL Open Type enclosure and does not include a human interface module (HIM). The configuration also has no DC terminals.
The dynamic braking transistor is an important feature for applications that require controlled deceleration. However, the transistor should not be confused with a braking resistor: the resistor may need to be selected separately according to the application’s regenerative energy and stopping requirements.
Because the 20F1AND248JA0NNNNN is a high-current Frame 6 drive, installation requires appropriate electrical distribution, protective devices, ventilation, grounding, and cabinet engineering. It should be selected according to the connected motor’s nameplate data and the actual operating duty rather than horsepower alone.
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley |
| Manufacturer | Rockwell Automation |
| Model | 20F1AND248JA0NNNNN |
| Product Series | PowerFlex 753 |
| Product Type | AC Drive / Variable Frequency Drive |
| Drive Construction | Air-Cooled |
| Frame Size | Frame 6 |
| Input Voltage Class | 480 V AC |
| Input Phase | Three-phase |
| Input Type | AC input with precharge |
| DC Terminals | Not included |
| Output Current | 248 A |
| Normal-Duty Power Rating | 200 HP |
| Heavy-Duty Power Rating | 150 HP |
| Cooling Method | Forced air |
| Control I/O | Embedded I/O |
| Protection Configuration | Standard protection |
| Enclosure Type | IP20/IP00, NEMA/UL Open Type |
| EMC Filtering | Filtered |
| Common-Mode Jumper | Installed |
| Dynamic Braking | DB transistor |
| Human Interface Module | Blank configuration; no HIM |
| Dimensions Provided | 665.5 × 308 × 346.4 mm |
| Weight Provided | 38.6 kg |
| Typical Application | High-power industrial motor control |
Note: Dimensions and weight are the supplied listing values. Confirm the exact drive configuration and manufacturer’s dimensional drawing before designing a mounting arrangement or calculating shipping requirements.
The PowerFlex 753 AC drive regulates the electrical power supplied to a three-phase AC motor. It converts incoming AC power into a controlled output, allowing the motor to operate at different speeds according to the configured reference and application requirements.
An AC motor’s operating speed is related to the frequency of its electrical supply and its design characteristics. By changing the output frequency, the drive can regulate motor speed to match the requirements of the production process.
For example, a large conveyor may need to operate at different speeds depending on material flow. A pump may need to adjust its output according to process demand. A variable frequency drive provides a means of controlling these operating conditions without relying exclusively on mechanical speed-control devices.
The actual speed range depends on the motor, load characteristics, cooling requirements, and drive configuration.
The 20F1AND248JA0NNNNN has a rated output current of 248 A. This high-current capability makes it suitable for appropriately rated industrial motors and equipment.
The normal-duty rating is 200 HP, while the heavy-duty rating is 150 HP. These ratings represent different application and overload conditions. The correct selection must consider motor current, starting torque, load inertia, acceleration requirements, and the expected operating cycle.
A drive should not be selected solely by comparing its horsepower rating with the motor’s nominal power. The motor nameplate current and the application’s overload requirements are essential selection criteria.
The PowerFlex 753 includes embedded I/O to support drive control and status interfaces. This allows the drive to participate in machine-control systems without relying entirely on additional external I/O hardware.
Depending on the system design, embedded I/O can be used for operating commands, status signals, and other configured control functions.
The actual terminal assignments and supported signal functions should be verified against the applicable technical documentation before wiring.
This catalog configuration includes a dynamic braking transistor. During deceleration, a motor may return energy to the drive’s DC bus. A suitable dynamic braking circuit can direct this energy to an external braking resistor, where it is converted into heat.
Dynamic braking can be useful when a machine needs controlled stopping or when its load has substantial inertia.
The transistor is not itself a braking resistor. Engineers must determine whether an external resistor is required and select the appropriate resistance, power rating, duty cycle, and thermal protection according to the manufacturer’s instructions.
The drive uses an AC input with precharge. Precharge is part of the input power arrangement and helps manage the initial charging of the drive’s DC bus capacitors when power is applied.
This function is particularly important in high-power drives because uncontrolled charging current can place stress on electrical components and upstream power equipment.
The input supply, protective devices, and installation sequence must follow the manufacturer’s requirements.
The 20F1AND248JA0NNNNN uses forced-air cooling. Airflow is required to remove heat generated during power conversion and motor operation.
The installation must provide sufficient ventilation and clearance around the drive. Blocked air passages, excessive ambient temperature, or contaminated cooling components can lead to overheating and reduced operating reliability.
The PowerFlex 753 can serve as a major motor-control component within a plant automation architecture. It operates between the electrical distribution system and the connected motor, while coordinating with PLCs, operator interfaces, sensors, and other control equipment.
A programmable logic controller can coordinate drive operation with the production sequence. Depending on the configured control method, the PLC may issue start and stop commands, provide speed references, monitor operating status, and respond to drive fault signals.
The PowerFlex 753’s embedded I/O provides local control and status capabilities. Additional communication options may be used when network-based integration is required, but the exact communication hardware must be confirmed separately.
The catalog number 20F1AND248JA0NNNNN should not be assumed to include every optional communication module.
An HMI allows operators to monitor production conditions and issue authorized machine commands. In a typical system, the HMI communicates with a PLC or control network that coordinates the drive.
This specific catalog configuration is supplied without a HIM. Therefore, it does not include the local human-interface module as part of the configured drive.
Where local parameter access or operator control is necessary, engineers should confirm the appropriate HIM or programming arrangement before commissioning.
The drive can be incorporated into a larger control strategy for coordinating motors with other industrial equipment.
For example, a PLC may adjust conveyor speed according to upstream material flow, regulate pump operation based on process pressure, or coordinate fan speed with ventilation demand.
The drive provides motor control, while the PLC and associated instrumentation manage the wider process logic.
In a connected automation system, drive status and operating information can be incorporated into a supervisory control system. This may help operators and maintenance personnel identify abnormal conditions, review operating states, and coordinate maintenance activities.
The available monitoring functions depend on the selected communication architecture and installed options.
The 20F1AND248JA0NNNNN is a high-power PowerFlex 753 drive intended for appropriately rated industrial motor applications.
Large conveyor installations are used in mining, manufacturing, logistics, and bulk-material handling. These systems may require substantial motor power and controlled acceleration to move heavy materials.
The PowerFlex 753 can regulate motor speed according to production demand and support controlled stopping when the system is correctly designed.
For conveyor applications, engineers should evaluate belt loading, starting torque, mechanical inertia, stopping distance, and braking requirements.
Large pumps are widely used in water treatment, chemical processing, power generation, and industrial fluid transportation.
A variable frequency drive can adjust pump motor speed to match changing flow or pressure requirements. This can support process regulation and may reduce unnecessary energy consumption in suitable variable-load applications.
Pump selection and drive configuration must account for fluid characteristics, minimum operating speed, pressure requirements, and motor cooling.
Large ventilation fans and process air-handling equipment often operate under changing airflow requirements.
A variable frequency drive can adjust fan motor speed according to process demand. This may help improve operating flexibility and reduce energy consumption when compared with constant-speed operation and mechanical airflow restriction.
The cabinet ventilation and drive cooling requirements must be considered separately from the ventilation system controlled by the motor.
Industrial processing systems may use large motors to operate mixers, crushers, feeders, and other mechanical equipment.
The drive can regulate motor speed to support process adjustments and controlled equipment operation. Heavy-duty applications must be checked carefully against the 150 HP heavy-duty rating and 248 A output current.
Large manufacturing lines may include multiple motors operating in coordinated sequences. A PowerFlex 753 can control a suitably rated motor as part of a PLC-based production system.
The drive’s embedded I/O and configurable architecture can support integration with machine controls, while optional communication hardware may provide additional connectivity where required.
The PowerFlex 753 may also be used in machinery upgrades where an existing motor-control system requires a high-current variable frequency drive.
Before replacing an older drive, engineers should evaluate motor compatibility, available cabinet space, control wiring, protection settings, braking requirements, and the wider automation architecture.
Because this is a 248 A Frame 6 drive, installation requires careful electrical and mechanical planning.
Confirm that the electrical supply matches the drive’s 480 V AC, three-phase voltage class.
The supply system must be designed for the drive’s input characteristics and power requirements. Upstream circuit breakers, fuses, disconnecting equipment, and conductors must be selected according to the manufacturer’s recommendations and applicable electrical codes.
The input supply must also be checked for compatibility with the drive’s precharge arrangement.
Before connecting the motor, verify its nameplate voltage, rated current, power, frequency, speed, and duty classification.
The drive’s 248 A output rating and 200 HP normal-duty / 150 HP heavy-duty ratings must be evaluated against the motor’s actual operating requirements.
The application may require a lower drive rating if the motor experiences frequent overloads, high starting torque, or demanding operating conditions.
The supplied dimensions are 665.5 × 308 × 346.4 mm. These values should be checked against the official dimensional drawing for the exact Frame 6 configuration.
Allow sufficient space for installation, wiring access, cooling airflow, inspection, and maintenance. The mounting structure must support the equipment’s actual weight and withstand the mechanical conditions of the installation.
The stated IP20/IP00, NEMA/UL Open Type enclosure is not a sealed enclosure. It must be installed within a suitable protective environment where required.
The drive uses forced-air cooling. The cabinet design must provide sufficient airflow and heat dissipation for the drive and other installed equipment.
Avoid obstructing ventilation openings. Ambient temperature, cabinet airflow, dust accumulation, and cooling-fan condition should be considered during installation and maintenance.
The installed dynamic braking transistor may be used with an appropriate external braking resistor when the application requires energy dissipation during deceleration.
Before selecting the resistor, calculate the expected braking energy and duty cycle. Confirm the permitted resistance range, power rating, thermal protection, and wiring requirements using the manufacturer’s documentation.
Do not connect an arbitrary resistor based only on the drive’s current rating.
Correct grounding is essential for electrical safety and electromagnetic compatibility.
The drive configuration includes EMC filtering and a common-mode jumper installed. Engineers should follow the manufacturer’s grounding and cable-shielding instructions and confirm that the jumper configuration is appropriate for the electrical distribution system.
Use suitable motor cables and keep control wiring separated from high-power conductors where required.
Before operating the motor, inspect all electrical connections, protective devices, grounding, and cooling arrangements.
During commissioning, configure the motor data, command sources, speed references, acceleration and deceleration times, protection settings, and braking parameters.
Test the motor at suitable operating conditions and verify the direction of rotation, speed response, fault handling, interlocks, and emergency stopping arrangements.
Record the final parameter configuration for future maintenance and replacement work.
The PowerFlex 753 is normally integrated into a wider industrial motor-control system. The following components may be used depending on the application and selected options.
| Component | Function | Integration Considerations |
|---|---|---|
| Three-phase AC motor | Converts electrical power into mechanical motion | Verify motor voltage, current, power, speed, and duty |
| PLC | Controls the machine sequence and drive commands | Confirm embedded I/O assignments and communication requirements |
| HMI | Provides operator monitoring and control | This catalog configuration does not include a HIM |
| Power distribution equipment | Supplies electrical power to the drive | Verify 480 V AC three-phase compatibility and input requirements |
| Circuit breaker or fuses | Provides upstream electrical protection | Select according to drive documentation and applicable codes |
| Disconnect switch | Supports electrical isolation | Follow the installation and safety requirements |
| External braking resistor | Dissipates regenerated energy | Required only where application braking calculations indicate |
| Communication option module | Provides network connectivity | Select a compatible option if network communication is required |
| Motor cable | Connects the drive to the motor | Select suitable insulation, current capacity, shielding, and length |
| Control cabinet | Houses and protects installed equipment | Provide appropriate ventilation, clearances, and environmental protection |
The components listed above are examples of a complete installation. They are not necessarily included with the 20F1AND248JA0NNNNN drive.
The PowerFlex 753 family includes different voltage classes, current ratings, frame sizes, and option configurations. A replacement must be selected according to the electrical and functional requirements of the original installation.
| Alternative or Related Product | Replacement Considerations |
|---|---|
| PowerFlex 753 with a different current rating | Compare voltage class, output current, duty rating, frame size, and options |
| PowerFlex 753 with a different braking configuration | Verify whether the application requires a braking transistor and external resistor |
| Allen-Bradley PowerFlex 755 | May be considered for applications requiring a different feature set or control architecture |
| Current-generation Rockwell Automation drive | May support a modernization project, but requires detailed engineering review |
| Another manufacturer’s industrial AC drive | Evaluate motor ratings, control interfaces, braking, communication, and installation requirements |
When selecting a replacement, check:
A drive with a similar horsepower rating is not automatically a direct replacement. Changes to wiring, control options, protection settings, braking arrangements, and cabinet design may be required.
With a rated output current of 248 A, the 20F1AND248JA0NNNNN is designed for large industrial motor-control applications.
The 200 HP normal-duty and 150 HP heavy-duty ratings allow engineers to evaluate the drive for different application load profiles.
The integrated I/O supports machine-level control and can simplify certain control-system designs.
The installed braking transistor supports dynamic braking arrangements when used with an appropriately selected external resistor.
The precharge input configuration is designed to manage the initial charging of the drive’s DC bus capacitors.
The configured filtering and installed common-mode jumper support electromagnetic compatibility when the drive is installed according to the manufacturer’s instructions.
The Frame 6 air-cooled construction supports operation in appropriately engineered industrial installations with sufficient ventilation.
The PowerFlex 753 can be integrated into PLC-based systems and larger industrial automation architectures using its embedded I/O and compatible optional communication equipment.
It is a PowerFlex 753 Frame 6 air-cooled AC drive designed for three-phase industrial motor control. It has a 248 A output rating and a 480 V AC voltage class.
The normal-duty rating is 200 HP. This rating should be checked against the motor’s nameplate current and the application’s operating requirements.
The heavy-duty rating is 150 HP. Heavy-duty operation involves different overload requirements and should not be confused with the normal-duty rating.
Yes. The catalog configuration includes a dynamic braking transistor. An external braking resistor may still be necessary, depending on the application’s stopping and regenerative-energy requirements.
The specified configuration identifies a DB transistor, not an included braking resistor. Confirm the required external braking hardware separately.
Yes. Embedded I/O is included in the specified PowerFlex 753 configuration. Verify terminal functions and wiring assignments using the manufacturer’s documentation.
No. The catalog configuration is listed as Blank (No HIM). A suitable interface must be arranged separately if local operator access is required.
The specified enclosure is IP20/IP00, NEMA/UL Open Type. It requires an appropriate installation environment and should not be treated as a sealed, water-resistant drive.
It uses forced-air cooling. Adequate cabinet ventilation and maintenance of the cooling system are important for reliable operation.
Yes. It can be integrated into a PLC-based system using its embedded I/O and suitable control architecture. Network communication requires confirmation of the appropriate communication hardware.
Verify the complete catalog number, nameplate, output rating, voltage class, frame size, braking configuration, embedded I/O, enclosure type, and physical condition. For used or refurbished equipment, request clear photographs and available functional-test information.
Not automatically. The complete catalog number must be compared because different PowerFlex 753 configurations may have different current ratings, voltage classes, braking options, filtering, and interfaces.
When purchasing the Allen-Bradley 20F1AND248JA0NNNNN, begin by verifying the complete catalog number and confirming that the unit matches the required 480 V AC, 248 A, Frame 6 configuration.
Check whether the drive includes the expected embedded I/O, dynamic braking transistor, EMC filter, and common-mode jumper configuration. Confirm that the product is supplied without a HIM, as specified by this catalog number, and establish whether any optional accessories are needed for the intended installation.
For used or surplus equipment, inspect the nameplate, enclosure, power terminals, control terminals, cooling fans, and visible circuit components. Request photographs of the actual unit rather than relying only on representative product images. Where the drive is intended for critical machinery, request appropriate functional testing and clarify warranty and return conditions.
During routine maintenance, inspect cooling airflow, fan operation, electrical connections, grounding, cabinet cleanliness, and signs of overheating. Maintenance intervals should follow the manufacturer’s guidance and account for the operating environment.
Keep a backup of drive parameters and record changes made during commissioning. This information can reduce troubleshooting time and help engineers restore the correct settings after maintenance or replacement.
For international procurement, verify the actual dimensions and weight of the packaged unit. The supplied dimensions of 665.5 × 308 × 346.4 mm and weight of 38.6 kg are useful listing parameters, but shipping calculations should use the measured package dimensions and gross weight.
The Allen-Bradley 20F1AND248JA0NNNNN PowerFlex 753 AC Drive is a high-current, 480 V AC three-phase variable frequency drive designed for large industrial motor-control applications. It provides a 248 A output rating, 200 HP normal-duty rating, and 150 HP heavy-duty rating in a Frame 6 forced-air-cooled configuration.
Its embedded I/O, AC input with precharge, EMC filtering, installed common-mode jumper, and dynamic braking transistor make it suitable for appropriately engineered industrial control systems. The drive is supplied without a HIM and does not include DC terminals.
For industrial maintenance, replacement, and procurement projects, accurate catalog-number verification is essential. Engineers should confirm the motor ratings, braking requirements, electrical protection, cooling arrangement, and control-system compatibility before installing or replacing the drive.