• Allen Bradley 1786-FS60 ControlNet Fiber Optic Cable
  • Allen Bradley 1786-FS60 ControlNet Fiber Optic Cable
  • Allen Bradley 1786-FS60 ControlNet Fiber Optic Cable
  • Allen Bradley 1786-FS60 ControlNet Fiber Optic Cable
Product Overview The Allen-Bradley 1786-FS60 is a 60-meter fiber optic cable assembly used in ControlNet industrial communication networks. It provides an optical transmission path between compatible sh……
Allen Bradley 1786-FS60 ControlNet Fiber Optic Cable
  • Allen Bradley
  • 1786-FS60
  • ControlNet Fiber Optic Cable
  • USA
  • 60 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 3

Our advantage

Allen Bradley 1786-FS60 ControlNet Fiber Optic Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 1786-FS60 ControlNet Fiber Optic Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 1786-FS60 ControlNet Fiber Optic Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 1786-FS60 ControlNet Fiber Optic Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Allen-Bradley 1786-FS60 is a 60-meter fiber optic cable assembly used in ControlNet industrial communication networks. It provides an optical transmission path between compatible short-distance fiber repeater interfaces, allowing network communication to extend between equipment areas without relying entirely on coaxial cabling.

The 1786-FS60 belongs to the 1786-FS family of preassembled ControlNet fiber cables. It uses 200-micron fiber with factory-terminated V-pin connectors and is intended for use with the Allen-Bradley 1786-RPFS short-distance fiber repeater.

In a manufacturing facility, ControlNet equipment may be distributed across several production areas. For example, a main PLC cabinet may be installed in an electrical room while a remote control panel serves machinery on the production floor. When the network architecture requires an optical connection between these locations, the 1786-FS60 provides a 60-meter cable link between compatible fiber interfaces.

One practical consideration when selecting this model is the actual cable routing distance. The 1786-FS20 may be sufficient for nearby cabinets, but installations with longer cable routes may require the FS60. Its 60-meter length offers additional routing capacity without moving into the longer cable options of the same series.

The cable uses a Versalink V-System termination arrangement. Since the connectors are installed at the factory, technicians can connect the assembly directly to compatible fiber interfaces without carrying out field termination.

The 1786-FS60 is a passive optical transmission component. It does not independently convert electrical signals or process ControlNet data. Signal conversion takes place in the connected repeater hardware, while the cable maintains the optical path between the network interfaces.

During installation, attention should be given to connector cleanliness, cable bending, and mechanical support. A damaged fiber section or contaminated connector can increase optical attenuation and interrupt communication, even when the connected repeater modules are functioning normally.


Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley
Brand Rockwell Automation
Model 1786-FS60
Product Series ControlNet
Product Type ControlNet Fiber Optic Cable
Cable Assembly Type Short-Distance Fiber Optic Cable Assembly
Fiber Size 200 Micron
Fiber Type 200/230 µm HCS (Hard-Clad Silica)
Number of Fibers 1
Fiber Termination Type Versalink V-System
Connector Configuration V-Pin Connectors
Cable Jacket PVC
Maximum Pull Tension 490 N
Cyclic Flexing More Than 5,000 Cycles
Minimum Bend Radius 25 mm
Operating Wavelength 650 nm
Optical Power Budget 4.2 dB
Operating Temperature -20 to +80°C
Non-Operating Temperature -40 to +80°C
Compatible Fiber Repeater 1786-RPFS
Network Compatibility Allen-Bradley ControlNet
Cable Length 60 meters
Shipping Weight 3 kg

Product Features

  • 60-Meter Cable Assembly: Provides an optical connection for ControlNet installations requiring a longer cable route between compatible network interfaces.
  • 200-Micron Fiber: Uses the fiber size specified for the ControlNet short-distance fiber cable family.
  • HCS Fiber Construction: Uses hard-clad silica fiber with a 200/230 µm fiber specification.
  • V-Pin Connector Termination: Features factory-installed Versalink V-System connectors for compatible repeater interfaces.
  • 1786-RPFS Compatibility: Intended for use with the Allen-Bradley short-distance fiber repeater.
  • Single-Fiber Configuration: Uses one optical fiber for the communication connection.
  • Electromagnetic Interference Immunity: Optical transmission avoids electrical signal coupling from nearby power equipment and motor circuits.
  • Factory-Terminated Construction: Eliminates the need for field connector termination during normal installation.
  • PVC Cable Jacket: Provides external protection for the fiber assembly during industrial cable routing.
  • Passive Operation: Carries optical communication signals without requiring an independent power supply.

Product Working Principle

The 1786-FS60 carries ControlNet communication signals through an optical fiber connection between compatible repeater interfaces.

In a conventional ControlNet coaxial network, communication signals travel through electrical conductors. When the network needs to extend through an optical connection, the 1786-RPFS repeater converts the electrical communication signals into optical signals before transmission through the fiber cable.

The 1786-FS60 carries these optical signals through its HCS fiber core. At the receiving end, the connected fiber interface converts the optical signals back into electrical communication signals for the next ControlNet network section.

A simplified communication path is:

ControlNet Coaxial Network → 1786-RPA → 1786-RPFS → 1786-FS60 → Remote Fiber Interface → ControlNet Network

The cable itself does not perform electrical-to-optical conversion or data processing. Its role is to maintain the optical transmission path between the connected devices.

The V-pin connectors establish the optical connection with the corresponding Versalink interfaces. Correct connector alignment and clean optical contact surfaces are necessary to prevent unnecessary transmission loss.

The 1786-RPFS short-distance fiber system operates at a wavelength of 650 nm and has a specified optical power budget of 4.2 dB. This budget accounts for losses throughout the optical connection, including fiber attenuation, connectors, and splices.

Because the FS60 is a 60-meter assembly, the installation route should be planned to avoid unnecessary connections and excessive bending. Maintaining the cable’s specified mechanical limits helps preserve the optical signal throughout the connection.


Role in Allen-Bradley ControlNet Network Architecture

The 1786-FS60 serves as the optical transmission medium in an Allen-Bradley ControlNet fiber repeater arrangement. It connects compatible short-distance fiber interfaces and allows communication to pass between network sections through an optical path.

A typical mixed-media architecture may use coaxial cable for the main ControlNet trunk and fiber connections for selected links between separated control areas.

A typical arrangement is:

ControlNet Coaxial Trunk → Network Tap → 1786-RPA → 1786-RPFS → 1786-FS60 → Remote Fiber Interface → ControlNet Network

System Component Function
Allen-Bradley 1786-FS60 Provides a 60-meter optical communication connection
1786-RPA Provides the modular repeater adapter interface
1786-RPFS Provides the short-distance fiber repeater interface
1786-RG6 Carries ControlNet communication through coaxial media
1786-XT Terminates the coaxial trunk segment
1786-TPS Provides a straight coaxial network tap
1786-TPR Provides a right-angle coaxial network tap
ControlNet Communication Modules Connect PLC controllers to the ControlNet network
Remote I/O Adapters Interface distributed I/O stations with the network
24 V DC Power Supply Supplies the modular repeater adapter

The 1786-FS60 is particularly suitable for network layouts requiring a preassembled optical connection between control cabinets or other separated automation equipment.


Industrial Applications

The 1786-FS60 is used in industrial facilities where ControlNet communication needs to pass between separated equipment areas through short-distance fiber repeater interfaces.

Industrial Application Typical Use
Automotive Manufacturing Connecting ControlNet fiber interfaces between production-line control cabinets
Packaging Machinery Establishing optical communication between machine control enclosures
Steel Manufacturing Connecting network sections around motors and high-power electrical equipment
Power Generation Linking automation equipment across separate electrical rooms
Oil and Gas Automation Providing optical connections between distributed control enclosures
Chemical Processing Connecting ControlNet equipment across separated process areas
Water Treatment Linking remote control cabinets and distributed I/O stations
Material Handling Establishing fiber connections between conveyor control areas
Industrial Drive Systems Connecting compatible fiber interfaces in drive control installations
General Manufacturing Extending ControlNet communication between production areas

Installation and Maintenance

  1. Verify Cable Compatibility: Confirm that the 1786-FS60 is being used with compatible 200/230 µm HCS fiber interfaces and the appropriate ControlNet repeater hardware.
  2. Check Repeater Interfaces: Verify that the connected equipment supports the Versalink V-System connector arrangement used by the short-distance fiber system.
  3. Inspect the Cable Assembly: Examine the cable jacket and connector ends for cuts, deformation, contamination, or visible mechanical damage before installation.
  4. Clean the Connectors: Clean the optical connector surfaces using suitable fiber cleaning materials before connecting the cable.
  5. Protect Unused Connectors: Keep protective caps installed whenever the cable is disconnected from the repeater modules.
  6. Plan the Cable Route: Map the 60-meter cable route before installation, avoiding sharp edges, moving machinery, and areas exposed to crushing forces.
  7. Maintain the Bend Radius: Keep the cable bend radius at or above the specified minimum of 25 mm throughout installation.
  8. Control Pulling Force: Do not exceed the maximum pulling tension of 490 N when routing the cable through trays or conduits.
  9. Connect the Fiber Interfaces: Align the V-pin connectors with the corresponding Versalink ports on the compatible repeater modules.
  10. Provide Cable Support: Secure the cable at appropriate intervals so that unsupported sections do not place excessive mechanical load on the connector assemblies.
  11. Verify Network Communication: Restore the system and check repeater status and communication between the connected ControlNet network sections.
  12. Document and Store: Record the cable route and connection points. If the cable is removed, reinstall protective caps and store it where the fiber cannot be crushed, kinked, or contaminated.

During troubleshooting, inspect both connector interfaces and the accessible cable route before replacing repeater modules. A localized kink, damaged section, or contaminated connector can increase optical attenuation and interrupt communication.


Compatible System Components

Component Function
Allen-Bradley 1786-FS60 60-meter ControlNet fiber optic cable assembly
Allen-Bradley 1786-FS10 10-meter ControlNet fiber optic cable assembly
Allen-Bradley 1786-FS20 20-meter ControlNet fiber optic cable assembly
Allen-Bradley 1786-FS100 100-meter ControlNet fiber optic cable assembly
Allen-Bradley 1786-FS200 200-meter ControlNet fiber optic cable assembly
Allen-Bradley 1786-FS300 300-meter ControlNet fiber optic cable assembly
Allen-Bradley 1786-FSB500 500-meter bulk ControlNet fiber cable
Allen-Bradley 1786-FSKIT ControlNet fiber connector kit
Allen-Bradley 1786-RPFS ControlNet short-distance fiber repeater
Allen-Bradley 1786-RPA ControlNet modular repeater adapter
Allen-Bradley 1786-RG6 ControlNet RG-6 coaxial trunk cable

Recommended Related Models

Model / Product Product Type Typical Application
Allen-Bradley 1786-FS20 ControlNet Fiber Optic Cable Assembly, 20 m Shorter optical connections
Allen-Bradley 1786-FS100 ControlNet Fiber Optic Cable Assembly, 100 m Longer connections between repeater interfaces
Allen-Bradley 1786-FS200 ControlNet Fiber Optic Cable Assembly, 200 m Extended ControlNet fiber connections
Allen-Bradley 1786-FS300 ControlNet Fiber Optic Cable Assembly, 300 m Maximum-length cable option in the FS assembly family
Allen-Bradley 1786-RPFS ControlNet Short-Distance Fiber Repeater Connecting coaxial and fiber network sections
Allen-Bradley 1786-FSKIT ControlNet Fiber Connector Kit Preparing compatible bulk fiber cable connections

Key Advantages

  • 60-meter preassembled cable for ControlNet fiber connections.
  • 200-micron HCS fiber construction.
  • Factory-terminated Versalink V-System connectors.
  • Compatible with the 1786-RPFS short-distance fiber repeater.
  • Optical transmission avoids direct electromagnetic interference coupling.
  • Reduces field connector termination work.
  • Supports mixed coaxial and fiber ControlNet network architectures.

Technical FAQs

1. What is the difference between the 1786-FS60 and the 1786-FS100?

Both models belong to the ControlNet short-distance fiber cable family and use the same general 200-micron fiber and V-pin connector arrangement. The main difference is cable length: the FS60 provides a 60-meter connection, while the FS100 provides a 100-meter connection.

2. Can the 1786-FS60 be used with the 1786-RPFS repeater?

Yes. The 1786-FS60 is listed as a short-distance fiber cable assembly for use with the 1786-RPFS repeater. Its fiber type and Versalink V-System termination match the short-distance fiber architecture.

3. What should be considered when installing the 1786-FS60 in a cable tray?

The cable route should avoid sharp bends, crushing forces, and excessive pulling tension. Maintain the minimum 25 mm bend radius and support the cable so that its weight is not carried entirely by the connector ends.

4. Does the 1786-FS60 require a separate power supply?

No. The 1786-FS60 is a passive fiber optic cable and does not require independent electrical power. The associated repeater hardware requires its specified power supply to perform signal conversion and network communication functions.



Related Products