Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Allen-Bradley 1786-FS100 is a 100-meter fiber optic cable assembly used in ControlNet communication networks. It belongs to the 1786-FS short-distance fiber cable family and connects compatible ControlNet fiber repeater modules through a preassembled optical connection.
Unlike conventional coaxial ControlNet trunk cables, the 1786-FS100 transmits communication signals through optical fiber. This makes it particularly useful when network connections must cross electrically noisy areas, connect separate control cabinets, or link automation equipment that is physically separated within an industrial facility.
The cable uses 200-micron HCS (Hard-Clad Silica) fiber and V-pin connectors compatible with the Versalink V-System interface. It is intended for use with the Allen-Bradley 1786-RPFS short-distance fiber repeater.
A typical application involves connecting two ControlNet fiber interfaces across different sections of a production facility. For example, a PLC control cabinet may communicate with a remote fiber repeater through the 1786-FS100, allowing the network to extend beyond the immediate area of the main coaxial trunk.
The 100-meter cable length offers greater routing flexibility than shorter assemblies such as the 1786-FS10 and 1786-FS20. It is suitable for installations where the connected equipment is separated by a longer cable route, without requiring technicians to prepare and terminate a custom fiber cable on site.
The 1786-FS100 is a passive optical transmission component. It does not convert electrical signals, amplify communication signals, or manage network traffic independently. Those functions are handled by the connected ControlNet repeater or communication hardware.
For maintenance engineers, connector cleanliness, cable routing, and minimum bend radius are important considerations. Damage to the fiber or contamination at the optical connection can increase signal loss and interrupt communication between network sections.
| Parameter | Specification |
|---|---|
| Manufacturer | Allen-Bradley |
| Brand | Rockwell Automation |
| Model | 1786-FS100 |
| Product Series | ControlNet |
| Product Type | ControlNet Fiber Optic Cable Assembly |
| Cable Assembly Category | Short-Distance Fiber Optic Cable |
| Fiber Type | 200-Micron HCS (Hard-Clad Silica) |
| Fiber Core | 200 µm |
| Connector Type | Versalink V-System |
| Connector Configuration | V-Pin Connectors |
| Cable Assembly | Preassembled Fiber Optic Cable |
| Compatible Fiber Module | 1786-RPFS |
| Operating Wavelength | 650 nm |
| Optical Power Budget | 4.2 dB |
| Cable Jacket | PVC |
| Maximum Pull Tension | 490 N |
| Minimum Bend Radius | 25 mm |
| Cyclic Flexing | More Than 5,000 Cycles |
| Operating Temperature | -20 to +80°C |
| Storage Temperature | -40 to +80°C |
| Network Compatibility | Allen-Bradley ControlNet |
| Cable Application | Fiber Repeater Interconnection |
| Cable Length | 100 meters |
| Shipping Weight | 3 kg |
The 1786-FS100 transfers ControlNet communication signals through an optical fiber connection between compatible fiber interfaces.
In a typical ControlNet installation, the main network may use coaxial trunk cable to connect controllers, communication modules, and network taps. When a section of the network needs to be extended through fiber, a compatible repeater converts the electrical network signals into optical signals.
The 1786-FS100 carries these optical signals through its HCS fiber core. At the receiving end, the connected fiber module converts the optical signals back into electrical communication signals for the next ControlNet network section.
A simplified communication path is:
ControlNet Coaxial Network → 1786-RPA → 1786-RPFS → 1786-FS100 → Remote 1786-RPFS Interface → ControlNet Network
The cable itself does not perform signal conversion. Its function is to maintain the optical transmission path between the connected modules.
The 200-micron HCS fiber construction is matched to the short-distance fiber repeater system. The V-pin connectors establish the optical interface with compatible equipment, while the cable’s optical power budget determines the allowable total signal loss across the fiber connection.
For the 1786-FS100, the specified optical power budget is 4.2 dB. This allowance must account for fiber attenuation, connector losses, and any additional optical connection losses in the installed link.
Cable handling also affects communication performance. Excessive bending, crushing, or pulling can damage the fiber structure and increase optical attenuation. Keeping the connectors clean and maintaining the specified bend radius helps preserve the optical transmission path.
The 1786-FS100 functions as the optical transmission link in an Allen-Bradley ControlNet fiber repeater arrangement. It allows compatible fiber modules to exchange communication signals across a distance of up to the cable assembly’s specified length.
In installations using mixed coaxial and fiber media, the coaxial trunk can serve the main network while fiber connections are introduced between selected network sections. This arrangement is useful when equipment is separated by long cable routes or when electrical isolation is required.
A typical arrangement is:
ControlNet Coaxial Trunk → Network Tap → 1786-RPA → 1786-RPFS → 1786-FS100 → Remote Fiber Repeater → ControlNet Network
| System Component | Function |
|---|---|
| Allen-Bradley 1786-FS100 | Provides a 100-meter optical connection between compatible fiber interfaces |
| 1786-RPA | Provides the modular repeater adapter interface |
| 1786-RPFS | Converts ControlNet coaxial communication into short-distance fiber communication |
| 1786-RG6 | Provides the ControlNet coaxial trunk connection |
| 1786-XT | Terminates the coaxial trunk segment |
| 1786-TPS | Provides a straight coaxial network tap |
| 1786-TPR | Provides a right-angle coaxial network tap |
| ControlNet Communication Modules | Connect PLC controllers to the ControlNet network |
| Remote I/O Adapters | Interface distributed I/O stations with the ControlNet system |
| 24 V DC Power Supply | Supplies power to the modular repeater adapter |
The 1786-FS100 is particularly relevant when a ControlNet network needs a longer optical connection between repeater modules while retaining the short-distance HCS fiber architecture.
The 1786-FS100 is used in industrial facilities where ControlNet communication needs to extend through fiber connections between separated automation areas.
| Industrial Application | Typical Use |
|---|---|
| Automotive Manufacturing | Connecting ControlNet repeater modules between production-line control sections |
| Steel Manufacturing | Establishing optical communication links near high-power motors and electrical equipment |
| Power Generation | Connecting control network sections across separate electrical rooms |
| Oil and Gas Automation | Providing fiber communication between distributed automation enclosures |
| Chemical Processing | Connecting ControlNet equipment across process areas with electrical interference |
| Water Treatment | Linking remote control cabinets and distributed I/O network sections |
| Packaging Machinery | Extending ControlNet communication between machine control panels |
| Material Handling | Connecting network sections across conveyor and sorting areas |
| Industrial Drive Systems | Providing optical communication between compatible drive interfaces and repeaters |
| General Manufacturing | Establishing longer fiber links between ControlNet network sections |
During troubleshooting, inspect the optical connectors and cable routing before replacing repeater modules. A contaminated connector, damaged fiber, or excessive bend can produce communication problems even when the electronic modules are functioning correctly.
| Component | Function |
|---|---|
| Allen-Bradley 1786-FS100 | 100-meter ControlNet short-distance fiber cable assembly |
| Allen-Bradley 1786-FS10 | 10-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-FS20 | 20-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-FS60 | 60-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-FS200 | 200-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-FS300 | 300-meter ControlNet fiber cable assembly |
| Allen-Bradley 1786-RPFS | ControlNet short-distance fiber repeater |
| Allen-Bradley 1786-RPA | ControlNet modular repeater adapter |
| Allen-Bradley 1786-RG6 | ControlNet RG-6 coaxial trunk cable |
| Allen-Bradley 1786-XT | ControlNet coaxial termination resistor |
| Allen-Bradley 1786-FSKIT | ControlNet fiber connector kit |
| Model / Product | Product Type | Typical Application |
|---|---|---|
| Allen-Bradley 1786-FS60 | ControlNet Fiber Optic Cable Assembly, 60 m | Shorter fiber connections between repeater interfaces |
| Allen-Bradley 1786-FS200 | ControlNet Fiber Optic Cable Assembly, 200 m | Longer optical connections in extended installations |
| Allen-Bradley 1786-FS300 | ControlNet Fiber Optic Cable Assembly, 300 m | Maximum-length cable assembly in the FS family |
| Allen-Bradley 1786-RPFS | ControlNet Short-Distance Fiber Repeater | Connecting ControlNet coaxial and fiber media |
| Allen-Bradley 1786-RPA | ControlNet Modular Repeater Adapter | Providing the repeater system interface |
| Allen-Bradley 1786-FSKIT | ControlNet Fiber Connector Kit | Preparing compatible fiber cable connections |
The 1786-FS100 belongs to the short-distance fiber cable family and is intended for use with the Allen-Bradley 1786-RPFS repeater. The repeater supports the 200-micron HCS fiber system and compatible V-System connections.
Both are members of the same short-distance ControlNet fiber cable family and use the same general fiber technology. The primary difference is cable length: the FS100 is 100 meters, while the FS60 is 60 meters. The actual installation must still meet the repeater’s optical power budget and cable-routing requirements.
Yes. The optical fiber link does not carry electrical current between its two ends. This helps isolate the connected network sections from electrical interference and unwanted conductive paths. The repeater hardware is responsible for converting the electrical network signals into optical signals and back again.
Start by checking whether both V-pin connectors are properly seated and clean. Then inspect the cable for kinks, excessive bending, or physical damage. If the cable and connectors are in good condition, verify the repeater power supply, module status, and total optical link loss against the specified 4.2 dB power budget.