The Siemens 6AG1244-0BB12-2PA1 SIPLUS G120 CU240E-2 DP Control Unit is an industrial drive control unit designed for use with the SINAMICS G120 frequency converter system. It manages drive commands, motor-control functions, communication, and safety-related stopping functions within compatible industrial automation installations.
This model belongs to the SIPLUS extreme product range. It is based on the Siemens 6SL3244-0BB12-1PA1 CU240E-2 DP control unit and features conformal coating intended to provide additional protection for electronic components in demanding industrial environments. Its specified extended temperature capability is suitable for applications where ordinary control electronics may be exposed to more challenging ambient conditions.
The CU240E-2 DP uses PROFIBUS DP for communication with higher-level automation equipment. It supports V/f control and sensorless vector control, allowing engineers to configure motor operation according to the connected application. The unit also includes Safety Integrated Safe Torque Off (STO), which supports safety-related motor torque removal when implemented within an appropriately designed safety system.
Its I/O configuration includes six digital inputs, three digital outputs, two analog inputs, and two analog outputs. It also provides interfaces for PTC/KTY temperature sensors, USB, and SD/MMC memory media.
The control unit is supplied without a Power Module. It therefore does not independently provide the complete power-conversion stage required to operate a motor. Instead, it must be installed with a compatible SINAMICS G120 power module and the associated electrical and mechanical components.
For replacement projects, engineers should check the complete order number, firmware version, drive configuration, PROFIBUS settings, and safety requirements before installation. Matching the control unit alone is not sufficient if the associated power module or automation architecture is different.
| Parameter | Specification |
|---|---|
| Brand | Siemens |
| Product Range | SIPLUS |
| Product Family | SINAMICS G120 |
| Model | 6AG1244-0BB12-2PA1 |
| Product Type | CU240E-2 DP Control Unit |
| Base Model | 6SL3244-0BB12-1PA1 |
| Communication Interface | PROFIBUS DP |
| Safety Function | Safety Integrated STO |
| Digital Inputs | 6 |
| Digital Outputs | 3 |
| Analog Inputs | 2 |
| Analog Outputs | 2 |
| Control Methods | V/f control; sensorless vector control |
| Temperature Sensor Interface | PTC/KTY |
| Memory Interface | SD/MMC |
| Service Interface | USB |
| Operating Voltage from Power Module | 24 V DC |
| External Supply Voltage | 20.4–28.8 V DC |
| Maximum Current Consumption | 0.5 A |
| Maximum Power Loss | 5.5 W |
| Protection Rating | IP20 |
| Conformal Coating | Included |
| Extended Ambient Temperature | -20 to +55 °C |
| Power Module | Not included |
| Dimensions | 73 × 199 × 46 mm |
| Weight | 0.49 kg |
| Typical Application | SINAMICS G120 motor-control systems |
The control unit and Power Module are separate components. Confirm the exact hardware and firmware compatibility before combining this unit with an existing drive system.
The 6AG1244-0BB12-2PA1 serves as the control center of a compatible SINAMICS G120 drive. It processes operating commands, manages motor-control functions, communicates with the automation system, and coordinates the drive’s available safety functions.
The control unit supports V/f control and sensorless vector control.
V/f control regulates the relationship between motor voltage and output frequency. It is commonly used for applications where straightforward speed adjustment is sufficient, such as fans, pumps, and general material-handling equipment.
Sensorless vector control provides more advanced motor regulation without requiring an encoder for speed feedback. When correctly configured, it can improve torque response and speed control compared with basic V/f operation.
The appropriate control method depends on the motor, mechanical load, operating range, and process requirements.
The integrated PROFIBUS DP interface allows the control unit to exchange data with compatible PLCs and automation devices.
Through the communication network, a higher-level controller can send drive commands and speed references while receiving operating status and diagnostic information. This supports coordinated control of multiple motors and production processes.
Typical exchanged information may include:
The actual data exchange depends on the configured PROFIBUS telegram, PLC program, device parameters, and network design.
The control unit supports Safety Integrated STO, or Safe Torque Off.
STO is a safety function designed to prevent the drive from generating torque-producing energy at the motor. It is used in machine designs where a safety-related stop function is required.
STO is not the same as electrical isolation. The drive and motor may remain connected to the power supply, and hazardous electrical voltage may still be present. Maintenance work must follow the required isolation and lockout procedures.
The safety circuit must be designed, validated, and maintained according to the machine’s risk assessment and applicable safety standards.
The unit provides six digital inputs, three digital outputs, two analog inputs, and two analog outputs.
Digital inputs can receive operating commands and machine signals, while digital outputs can provide status or control signals to external equipment.
The analog inputs can be used for variable reference signals, such as speed commands or process measurements. The analog outputs can provide corresponding signals to other control equipment.
The analog inputs support voltage and current signal configurations. Correct signal selection and wiring are essential to avoid incorrect readings or damage.
The PTC/KTY interface supports compatible motor temperature sensors.
Temperature information can be used as part of the motor-protection strategy. This is especially relevant when a motor operates under changing loads or in environments where thermal conditions require monitoring.
The selected sensor type and parameter settings must match the connected motor and the control unit’s supported configuration.
The control unit includes USB and SD/MMC interfaces for service and parameter-related functions.
These interfaces support commissioning, configuration, and maintenance activities. Engineers should follow the applicable Siemens documentation for supported memory media, parameter transfer procedures, and firmware requirements.
The 6AG1244-0BB12-2PA1 connects the SINAMICS G120 drive system with the wider industrial automation architecture. It coordinates motor operation while exchanging control and diagnostic information with PLCs, HMIs, and other field devices.
A PLC can communicate with the control unit through PROFIBUS DP. The PLC manages production logic and sends commands according to the operating conditions of the machine.
For example, a PLC may adjust a conveyor motor’s speed according to sensor signals or coordinate several motors in a packaging line.
The PROFIBUS configuration, telegram selection, device address, and PLC hardware configuration must be consistent.
An HMI can provide operators with access to drive-related information through the PLC or an appropriately designed communication architecture.
Typical monitored information includes:
This helps operators identify abnormal conditions and manage production equipment more effectively.
The CU240E-2 DP is the control component, not the complete motor power stage. It must be paired with a compatible SINAMICS G120 Power Module.
The control unit manages the drive’s control functions, while the Power Module handles the conversion of electrical energy for the connected motor.
The compatibility of the two components must be verified according to the relevant Siemens hardware and firmware documentation.
The integrated STO function can be incorporated into a machine’s safety architecture.
Depending on the risk assessment, safety-related signals may originate from emergency-stop devices, safety relays, or safety PLCs. The complete safety circuit must be engineered and validated rather than relying on the control unit alone.
The SIPLUS G120 CU240E-2 DP is suitable for compatible SINAMICS G120 drive installations across manufacturing, process automation, and material-handling environments.
Conveyor systems often require coordinated motor speed and controlled stopping.
The control unit can receive speed commands through PROFIBUS DP and manage motor operation through the associated G120 Power Module. This supports integration with sensors, PLCs, and other conveyor equipment.
Applications include:
Industrial pumps frequently operate under changing flow and pressure requirements.
The G120 control system can regulate motor speed according to process demand. This may help improve process control and reduce unnecessary operation at fixed speed.
Applications include:
Fans and ventilation systems may require adjustable airflow according to temperature, pressure, or occupancy conditions.
With suitable motor and Power Module selection, the control unit can manage variable-speed operation and communicate with the building or plant automation system.
Applications include:
Manufacturing equipment often uses variable-speed motors for feeding, conveying, mixing, and other mechanical operations.
The control unit’s PROFIBUS DP interface allows it to participate in coordinated PLC-based production systems. Its analog and digital I/O can also support external control signals.
Applications include:
The SIPLUS conformal coating is intended to provide additional protection for electronic assemblies in environments where condensation, corrosive gases, and other challenging conditions may affect standard electronics.
The extended temperature capability makes this version relevant to installations that require a wider specified operating temperature range.
However, the conformal coating does not make the control unit waterproof or suitable for unrestricted exposure to aggressive chemicals. The complete installation must still meet the required environmental and enclosure conditions.
Correct installation is essential for reliable drive operation, communication, and safety performance.
Before installation, confirm that the 6AG1244-0BB12-2PA1 is compatible with the selected SINAMICS G120 Power Module.
Check the base model, hardware version, firmware requirements, and available functions. Do not assume that every G120 Power Module can be combined with every control unit.
The supplied dimensions are 73 × 199 × 46 mm, with a weight of approximately 0.49 kg.
The control unit has an IP20 protection rating. It should be installed inside a suitable electrical cabinet or protected enclosure.
Consider the following installation conditions:
The SIPLUS conformal coating provides additional environmental protection but does not replace suitable cabinet design.
When connecting the control unit to a PROFIBUS DP network, verify the network address, communication speed, connector arrangement, termination, and PLC hardware configuration.
Incorrect termination or inconsistent network settings may cause communication faults or intermittent data exchange.
Use suitable PROFIBUS cables and connectors, and follow the network installation guidelines.
Connect digital and analog signals according to the terminal assignment and electrical requirements.
For analog inputs, select the appropriate voltage or current signal type. Confirm signal polarity, reference potential, shielding, and grounding.
Avoid routing low-level analog signals alongside high-current motor cables unless the installation design provides suitable separation and interference protection.
The STO function must be integrated into a suitable safety circuit.
Before commissioning, verify the safety wiring, external safety devices, diagnostic behavior, and required validation procedures.
STO should not be treated as a substitute for electrical isolation during maintenance.
Commissioning should include verification of the control unit, Power Module, motor, PLC communication, and safety functions.
Typical commissioning tasks include:
A complete commissioning record helps maintenance personnel diagnose faults and restore the intended operating configuration.
The 6AG1244-0BB12-2PA1 is intended to operate as part of a SINAMICS G120 drive installation.
| Component | Function | Integration Considerations |
|---|---|---|
| SINAMICS G120 Power Module | Converts electrical power for motor operation | Must be compatible with the CU240E-2 DP |
| Three-phase AC motor | Provides mechanical motion | Verify voltage, current, power, and control requirements |
| Siemens SIMATIC PLC | Executes machine-control logic | Configure PROFIBUS DP communication and drive telegrams |
| PROFIBUS DP cable | Provides fieldbus communication | Use suitable cable, connectors, and termination |
| HMI panel | Provides operator monitoring and control | Usually integrated through the PLC or drive communication architecture |
| Safety relay or safety PLC | Supports safety-related machine functions | Must be correctly integrated with STO |
| PTC/KTY temperature sensor | Provides motor temperature information | Confirm supported sensor type and parameter settings |
| SD/MMC memory media | Supports parameter and service functions | Follow Siemens compatibility and handling instructions |
| USB service connection | Supports commissioning and service access | Use the supported connection and software procedure |
| Electrical cabinet | Provides mounting and environmental protection | Ensure suitable enclosure protection and cooling |
The control unit does not include the Power Module. Other system components and accessories must be selected separately according to the application.
When replacing the 6AG1244-0BB12-2PA1, it is important to distinguish between SIPLUS and standard SINAMICS G120 versions.
The 6AG1244-0BB12-2PA1 is based on the standard 6SL3244-0BB12-1PA1 CU240E-2 DP. The SIPLUS version adds conformal coating and an extended environmental specification.
| Model | Product Description | Replacement Considerations |
|---|---|---|
| 6AG1244-0BB12-2PA1 | SIPLUS G120 CU240E-2 DP | Original SIPLUS version with conformal coating and PROFIBUS DP |
| 6SL3244-0BB12-1PA1 | SINAMICS G120 CU240E-2 DP | Standard base model; environmental protection differs |
| 6AG1244-0BB12-2FA0 | SIPLUS G120 CU240E-2 PN | PROFINET version; network interface differs |
| 6SL3244-0BB12-1FA0 | SINAMICS G120 CU240E-2 PN | Standard PROFINET version; not a direct PROFIBUS substitute |
| 6AG1244-0BB12-2BA1 | SIPLUS G120 CU240E-2 USS | USS communication version; requires interface and system review |
Before selecting an alternative, verify:
A model with a similar physical appearance may have a different communication interface or environmental specification. Replacement should therefore be based on the complete order number and application requirements.
The conformal coating provides additional protection for electronic assemblies in demanding industrial environments. This makes the unit suitable for applications where environmental conditions require more than standard control electronics.
The integrated PROFIBUS DP interface supports communication with compatible PLCs and automation equipment, allowing the drive to participate in coordinated production systems.
Safety Integrated STO supports safety-related motor torque removal when correctly incorporated into a validated machine safety architecture.
V/f control and sensorless vector control provide different motor-control approaches for a range of industrial applications.
The six digital inputs, three digital outputs, two analog inputs, and two analog outputs provide interfaces for external commands, process signals, and equipment status.
The PTC/KTY interface supports compatible motor temperature monitoring arrangements.
USB and SD/MMC interfaces support commissioning and maintenance activities, subject to the relevant Siemens procedures.
It is a SIPLUS G120 CU240E-2 DP control unit designed for compatible SINAMICS G120 frequency converter systems. It provides motor-control functions, PROFIBUS DP communication, I/O, and Safety Integrated STO.
The 6AG1244-0BB12-2PA1 is the SIPLUS version based on the standard 6SL3244-0BB12-1PA1. The SIPLUS version includes conformal coating and an extended environmental temperature specification.
No. The 6AG1244-0BB12-2PA1 is supplied as a control unit without a Power Module. A compatible SINAMICS G120 Power Module is required for a complete drive system.
This model supports PROFIBUS DP. It should not be confused with the CU240E-2 PN version, which uses PROFINET.
The unit supports Safety Integrated Safe Torque Off (STO). STO prevents the drive from generating torque at the motor when the safety function is correctly activated. It does not provide electrical isolation.
The specified configuration includes six digital inputs, three digital outputs, two analog inputs, and two analog outputs.
Yes. It supports sensorless vector control as well as V/f control. Encoder-based vector control is not specified for this model.
The SIPLUS version is specified for an extended temperature range of -20 to +55 °C. Confirm the applicable operating conditions and installation requirements in the product documentation.
Yes. It includes a PTC/KTY interface for compatible motor temperature sensors. Correct sensor selection and parameter configuration are necessary.
Verify the complete order number, communication interface, Power Module compatibility, firmware, I/O configuration, safety requirements, and environmental specification. If the existing system uses PROFIBUS DP, a PROFINET version should not be substituted without reviewing the network architecture and engineering changes.
When purchasing the Siemens 6AG1244-0BB12-2PA1, verify that the product label matches the complete order number. This is particularly important because several CU240E-2 control units have similar model descriptions but different communication interfaces and environmental specifications.
For replacement projects, check whether the existing drive system requires the SIPLUS conformal coating and extended temperature capability. A standard CU240E-2 DP may share the basic control-unit platform but does not automatically provide the same environmental protection.
Confirm that the associated Power Module is compatible and that the PLC program, PROFIBUS configuration, drive telegram, and safety circuit are suitable for the replacement unit.
For used or refurbished products, inspect the housing, connectors, terminals, communication interface, and memory-card slot. Request photographs of the nameplate and available functional test information. Verify firmware and hardware revisions before installation.
During routine maintenance, keep the control unit clean and maintain suitable cabinet conditions. Inspect wiring, connectors, grounding, and communication connections. Back up drive parameters and retain commissioning records to simplify troubleshooting and future replacement work.
The Siemens 6AG1244-0BB12-2PA1 SIPLUS G120 CU240E-2 DP Control Unit is an industrial drive controller designed for compatible SINAMICS G120 systems. It combines PROFIBUS DP communication, V/f and sensorless vector control, Safety Integrated STO, comprehensive digital and analog I/O, and conformal-coated electronics.
Its extended environmental specification makes it relevant to industrial installations that require additional protection for control electronics. Since the unit is supplied without a Power Module, compatibility with the associated drive hardware must be confirmed before installation.
For maintenance, procurement, and system integration projects, accurate order-number verification, firmware checking, and review of communication and safety requirements are essential to ensure reliable operation.