• Siemens 6AG1244-0BB12-2BA1 Control Unit
  • Siemens 6AG1244-0BB12-2BA1 Control Unit
  • Siemens 6AG1244-0BB12-2BA1 Control Unit
  • Siemens 6AG1244-0BB12-2BA1 Control Unit
Product Overview The Siemens 6AG1244-0BB12-2BA1 SIPLUS G120 CU240E-2 USS Control Unit is a specialized drive control unit designed for use with SINAMICS G120 variable frequency drive systems. It manages……
Siemens 6AG1244-0BB12-2BA1 Control Unit
  • Siemens
  • 6AG1244-0BB12-2BA1
  • Control Unit
  • Germany
  • 73 x 199 x 46 mm
  • 0.49 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Siemens 6AG1244-0BB12-2BA1 Control Unit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Siemens 6AG1244-0BB12-2BA1 Control Unit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Siemens 6AG1244-0BB12-2BA1 Control Unit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Siemens 6AG1244-0BB12-2BA1 Control Unit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Siemens 6AG1244-0BB12-2BA1 SIPLUS G120 CU240E-2 USS Control Unit is a specialized drive control unit designed for use with SINAMICS G120 variable frequency drive systems. It manages motor-control functions, processes control signals, and provides communication between the drive system and higher-level automation equipment.

Unlike a complete variable frequency drive, the CU240E-2 USS is the control section of a modular drive architecture. It works with a compatible SINAMICS G120 Power Module, which handles the power conversion required to operate the connected motor. The Control Unit manages the drive’s operating logic, command processing, parameter settings, and communication functions.

This SIPLUS version is based on the standard Siemens 6SL3244-0BB12-1BA1 control unit. It includes conformal coating on its electronic assemblies and is designed for an extended operating temperature range of -20°C to +55°C. These characteristics make it suitable for industrial installations where environmental conditions may be more demanding than those found in conventional control cabinets.

The 6AG1244-0BB12-2BA1 uses an RS-485 interface with the USS communication protocol. Its integrated I/O configuration includes six digital inputs, three digital outputs, two analog inputs, and two analog outputs. It also supports Safety Integrated Safe Torque Off (STO), allowing the drive system to implement an appropriate safety-related torque-removal function when integrated and validated correctly.

The control unit provides a practical interface between a PLC, operator-control equipment, sensors, and the SINAMICS G120 drive system. Its compact design and SIPLUS environmental protection features make it useful in industrial motor-control applications that require reliable communication and coordinated drive operation.

Technical Specifications

Parameter Specification
Brand Siemens
Product Family SIPLUS SINAMICS G120
Model 6AG1244-0BB12-2BA1
Product Type Drive Control Unit
Control Unit Designation CU240E-2 USS
Based on Standard Model 6SL3244-0BB12-1BA1
Communication Interface RS-485
Communication Protocol USS
Digital Inputs 6
Digital Outputs 3
Analog Inputs 2
Analog Outputs 2
Safety Function Safety Integrated STO
Encoder Interface PTC/KTY interface configuration
Memory and Service Interface USB and SD/MMC interface
Protection Rating IP20
Conformal Coating Yes
Operating Temperature -20°C to +55°C
Power Module Not included
Width 73 mm
Height 199 mm
Depth 46 mm
Dimensions 73 × 199 × 46 mm
Weight 0.49 kg
Typical Application SINAMICS G120 motor-control systems

The control unit is supplied without a Power Module. Confirm the exact compatible drive hardware and firmware requirements before installation.

Function and Working Principle

The CU240E-2 USS acts as the control center of a SINAMICS G120 drive system. It receives operating commands, processes feedback signals, manages motor-control functions, and communicates with external automation equipment.

1. Drive Command Processing

The control unit receives commands from a PLC, operator interface, or another configured control source. These commands can include start, stop, speed reference, direction, and other operating instructions.

The CU240E-2 USS processes the commands and coordinates the operation of the connected Power Module. This arrangement separates the control functions from the power-conversion hardware, allowing the drive system to be configured for different motor and application requirements.

2. Motor Speed and Torque Control

The control unit manages the selected motor-control strategy according to the configured SINAMICS G120 system.

The drive can support V/f control and sensorless vector-control functions, depending on the selected configuration and application parameters. V/f control is commonly used for applications where a relatively straightforward relationship between motor voltage and frequency is sufficient.

Sensorless vector control can provide improved motor response and torque management in applications that require more demanding speed-control performance.

Actual performance depends on the connected Power Module, motor characteristics, firmware, parameter settings, and load conditions.

3. Digital Input and Output Processing

The control unit provides six digital inputs and three digital outputs.

Digital inputs can be used to receive external signals such as start commands, stop requests, operating-mode selections, and equipment interlocks. Digital outputs can provide status information or control signals to other equipment, depending on the configured functions.

These I/O points allow the drive to participate in machine-control sequences without requiring every command or status signal to pass through a communication network.

4. Analog Signal Processing

Two analog inputs and two analog outputs are available for compatible process signals.

Analog inputs can receive external reference signals, such as speed commands or process measurements. Analog outputs can be configured to provide selected operating information to other control equipment.

The signal type, electrical range, scaling, and terminal assignment should be checked against the applicable Siemens documentation before wiring.

5. USS Communication

The 6AG1244-0BB12-2BA1 uses an RS-485 interface with the USS protocol.

USS provides a serial communication method for exchanging drive commands, parameter information, and operating data. A compatible PLC or controller can use this interface to coordinate the drive with other equipment in an automated system.

The communication settings, addressing, baud rate, and network wiring must be configured consistently between the control unit and the connected controller.

6. Safety Integrated STO

The control unit supports Safety Integrated Safe Torque Off.

STO is designed to prevent the drive from generating torque at the motor when the safety function is activated through a properly designed safety circuit. It is useful in machine designs where hazardous motor movement must be prevented under specified conditions.

STO is not the same as electrical isolation. It does not replace the required procedures for disconnecting and verifying the absence of hazardous electrical energy during maintenance. Safety functions must be designed, wired, validated, and maintained according to applicable safety standards.

Role in Industrial Automation Systems

The Siemens 6AG1244-0BB12-2BA1 is an important control component within a SINAMICS G120 drive installation. It connects the motor-control system with the broader automation architecture.

PLC-Based Motor Control

A PLC can send operating commands to the CU240E-2 USS through the configured USS communication interface or suitable control signals.

For example, a PLC may start a conveyor motor when production conditions are satisfied, adjust its speed according to material flow, and stop it when a downstream process is unavailable.

The control unit processes these commands and manages the connected drive hardware.

HMI and Operator Interaction

An HMI can provide operators with access to motor-control commands, operating information, and alarm indications.

In a typical installation, the HMI communicates with the PLC, which coordinates the drive system. Depending on the control architecture, drive parameters and operating information may also be accessed through the USS communication connection.

Sensor and Process Signal Integration

The integrated analog and digital I/O allows the control unit to interact with external devices.

For example, digital inputs may receive machine interlock signals, while analog inputs may be used for a speed reference or another compatible process signal. Outputs can communicate selected drive conditions to the surrounding equipment.

Modular Drive Architecture

The SINAMICS G120 platform separates the Control Unit from the Power Module. This modular structure allows the control and power sections to be selected according to the motor and application.

The CU240E-2 USS provides the control functions, while the compatible Power Module supplies the required power conversion. Correct matching between these components is essential for safe and reliable operation.

Industrial Applications

The 6AG1244-0BB12-2BA1 can be used in industrial systems that require coordinated motor control, serial communication, and integrated safety functions.

1. Conveyor and Material-Handling Systems

Conveyor systems often require adjustable motor speed to coordinate product movement between different production stages.

The CU240E-2 USS can receive speed and operating commands from a PLC and coordinate the connected G120 drive. Digital inputs can be used for external interlocks, while analog signals can support compatible speed-reference arrangements.

2. Pumping Equipment

Industrial pumps may need to adjust motor speed according to pressure, flow, or process demand.

A compatible SINAMICS G120 system controlled by this unit can support variable-speed operation. The appropriate control method and motor parameters should be selected according to the pump’s operating characteristics.

3. Fan and Ventilation Systems

Fans and ventilation equipment frequently operate under changing airflow requirements.

When used with an appropriately selected Power Module and motor, the control unit can coordinate speed adjustments through PLC commands or configured analog references.

4. Packaging Machinery

Packaging lines use multiple motors for feeding, conveying, sealing, and other production operations.

The CU240E-2 USS can provide drive control and I/O integration within a PLC-based machine architecture. Coordinated operation can help maintain production timing and reduce unnecessary interruptions.

5. Manufacturing and Assembly Equipment

Manufacturing equipment may require controlled motor acceleration, speed adjustment, and defined stopping behavior.

The control unit can support these requirements when paired with compatible SINAMICS G120 hardware and correctly configured control logic.

6. Industrial Equipment Operating in Demanding Environments

The SIPLUS version includes conformal coating and an extended operating temperature range compared with standard configurations.

These characteristics make it relevant to installations where temperature and environmental conditions require additional consideration. The IP20 protection rating still applies, so the control unit must be installed in an appropriate enclosure.

Installation and System Integration

Correct installation is essential for reliable communication, drive performance, and safety.

1. Confirm Power Module Compatibility

The 6AG1244-0BB12-2BA1 is a Control Unit, not a complete drive.

Before installation, confirm that the connected SINAMICS G120 Power Module is compatible with the CU240E-2 USS. Check the drive configuration, hardware revision, firmware requirements, and supported motor ratings.

Do not connect a motor directly to the Control Unit.

2. Install in an Appropriate Enclosure

The control unit has an IP20 protection rating. It should be installed in a suitable control cabinet that provides protection against dust, moisture, accidental contact, and other environmental hazards.

Maintain the manufacturer’s required mounting clearances and ventilation conditions. Avoid installing the unit where condensation, conductive particles, or corrosive contaminants may damage the electronics.

3. Connect the USS Communication Interface

The RS-485 interface should be wired according to the applicable USS communication guidelines.

Check the communication cable, polarity, shielding, grounding, network topology, and termination requirements. Incorrect wiring or inconsistent communication parameters may result in intermittent communication or failure to establish a connection.

4. Configure Digital and Analog I/O

Identify the required signal functions before connecting external equipment.

Digital inputs may be assigned to operating commands or interlocks. Digital outputs can be configured for selected status functions. Analog inputs and outputs should be matched to the electrical signal ranges and scaling requirements of the connected devices.

Always verify terminal assignments and electrical specifications using the correct documentation.

5. Configure the Drive Parameters

After installation, configure the drive according to the motor nameplate and application requirements.

Important settings may include motor voltage, rated current, rated frequency, speed limits, acceleration and deceleration times, command sources, and communication parameters.

The selected control method should match the application. If sensorless vector control is required, follow the manufacturer’s commissioning and motor-identification procedures.

6. Validate the STO Safety Function

Where STO is used, the safety circuit must be designed and implemented according to the machine’s risk assessment and applicable standards.

Verify the safety wiring, safety devices, response behavior, and required validation procedures. Do not treat an ordinary PLC stop command as equivalent to a validated safety function.

7. Perform Commissioning Tests

Before returning the system to production, verify:

  • Correct Control Unit and Power Module combination.
  • Firmware and parameter compatibility.
  • Proper motor connections.
  • Correct digital and analog I/O operation.
  • Stable USS communication.
  • Correct motor direction and speed response.
  • STO function and safety-circuit behavior.
  • Alarm and fault response.
  • Cabinet ventilation and environmental conditions.

Record the final parameter configuration and communication settings for future maintenance.

Compatible System Components

The 6AG1244-0BB12-2BA1 is designed to operate within the SINAMICS G120 modular drive platform.

Component Function Integration Considerations
SINAMICS G120 Power Module Provides motor power conversion Must be compatible with the CU240E-2 USS
Three-phase AC motor Converts electrical power into mechanical motion Verify voltage, current, power, and motor-control requirements
SIMATIC PLC Provides higher-level automation control Configure compatible USS communication or I/O signals
HMI Provides operator commands and monitoring Usually integrated through the PLC or configured drive interface
RS-485 communication cable Connects the USS communication interface Follow wiring, shielding, and termination requirements
Digital sensors and switches Provide machine status and interlock signals Match electrical characteristics to the digital inputs
Analog transmitters Provide process reference or measurement signals Verify signal type, range, and scaling
Safety relay or safety controller Supports the machine safety architecture Must be designed and validated for the required STO function
Control cabinet Protects and houses the drive components Maintain appropriate environmental conditions and ventilation

The Control Unit does not include the Power Module. The complete drive system must be assembled from compatible components.

Related Models and Replacement Considerations

The 6AG1244-0BB12-2BA1 belongs to the SIPLUS G120 CU240E-2 USS family. Other SINAMICS G120 Control Units may look similar but use different communication interfaces or control configurations.

Model Description Main Difference
6AG1244-0BB12-2BA1 SIPLUS G120 CU240E-2 USS RS-485 with USS protocol and conformal coating
6SL3244-0BB12-1BA1 Standard CU240E-2 USS Standard industrial version without the SIPLUS environmental configuration
6AG1244-0BB12-2PA1 SIPLUS G120 CU240E-2 DP PROFIBUS DP communication variant
6AG1244-0BB12-2FA0 SIPLUS G120 CU240E-2 PN PROFINET communication variant

These models are related but are not automatically interchangeable.

Before selecting a replacement, verify:

  • Full order number and product designation.
  • USS, PROFIBUS DP, or PROFINET communication requirements.
  • Digital and analog I/O configuration.
  • Safety functionality.
  • Power Module compatibility.
  • Firmware and parameter compatibility.
  • Environmental protection and temperature requirements.
  • Installation dimensions and connector arrangement.

A communication-interface difference can affect PLC hardware configuration and control-program logic. Replacing a USS unit with a PROFIBUS or PROFINET model may therefore require changes to the automation system.

Key Advantages

SIPLUS Environmental Protection

The conformal coating provides additional protection for electronic assemblies in demanding industrial environments. The extended temperature range supports installations with wider ambient-temperature requirements.

Integrated USS Communication

The RS-485 USS interface provides a serial communication method for connecting the drive to compatible controllers and automation equipment.

Built-In I/O Flexibility

Six digital inputs, three digital outputs, two analog inputs, and two analog outputs provide multiple options for connecting sensors, control signals, and external devices.

Safety Integrated STO

The integrated STO capability supports safety-related drive applications when correctly designed and validated as part of the machine safety system.

Modular SINAMICS G120 Architecture

Separating the Control Unit from the Power Module allows the drive system to be configured around the motor and application requirements.

Compact Construction

The dimensions of 73 × 199 × 46 mm and supplied weight of 0.49 kg make the control unit suitable for installation in appropriately designed industrial control cabinets.

Industrial Drive Integration

The CU240E-2 USS can coordinate motor operation with PLCs, operator interfaces, sensors, and other automation equipment through its communication and I/O functions.

Technical FAQs

1. What is the Siemens 6AG1244-0BB12-2BA1?

It is a SIPLUS G120 CU240E-2 USS Control Unit used in SINAMICS G120 variable frequency drive systems. It manages drive control functions, I/O signals, communication, and supported safety functions.

2. Is the 6AG1244-0BB12-2BA1 a complete frequency converter?

No. It is the Control Unit section of a modular drive system. A compatible SINAMICS G120 Power Module is required for the complete motor-drive installation.

3. What is the difference between this model and 6SL3244-0BB12-1BA1?

The 6AG1244-0BB12-2BA1 is the SIPLUS version based on the standard 6SL3244-0BB12-1BA1. The SIPLUS version includes conformal coating and an extended environmental operating-temperature specification.

4. What communication protocol does this Control Unit use?

It uses an RS-485 interface with the USS communication protocol. The connected controller must support the required USS communication configuration.

5. How many digital and analog I/O points are available?

The unit provides six digital inputs, three digital outputs, two analog inputs, and two analog outputs.

6. Does the 6AG1244-0BB12-2BA1 support PROFINET?

No. This specific model is the USS communication variant. A PROFINET application requires a suitable PROFINET Control Unit, such as the corresponding CU240E-2 PN version.

7. Does this Control Unit support safety functions?

Yes. It supports Safety Integrated STO. The safety function must be implemented and validated according to the system’s safety design and applicable standards.

8. What is the operating temperature range?

The SIPLUS product specification gives an operating range of -20°C to +55°C. The actual installation must still meet the required enclosure, humidity, condensation, and ventilation conditions.

9. Can it be connected directly to a motor?

No. The Control Unit does not perform the power conversion needed to drive a motor. It must be installed with a compatible SINAMICS G120 Power Module and the required electrical connections.

10. What should be checked before replacing this unit?

Verify the complete order number, communication protocol, I/O configuration, safety requirements, Power Module compatibility, firmware, and environmental specifications. Similar-looking CU240E-2 models may have different interfaces and cannot be assumed to be direct replacements.

Procurement and Maintenance Recommendations

When purchasing the Siemens 6AG1244-0BB12-2BA1, verify the complete order number and product designation. The USS communication interface is a defining feature of this model, so it should not be confused with the PROFIBUS DP or PROFINET versions.

For replacement projects, compare the existing Control Unit’s hardware and firmware configuration with the proposed replacement. Confirm that the installed Power Module supports the selected Control Unit and that the PLC can communicate through the required USS interface.

For used or surplus units, inspect the connectors, terminals, housing, and electronic assemblies. Check for signs of corrosion, contamination, mechanical damage, or improper storage. Confirm that the supplied unit is the SIPLUS version with the required conformal coating.

During maintenance, keep unused interfaces protected with the supplied plug covers as required by the manufacturer’s instructions. Check wiring, communication stability, grounding, and enclosure conditions. Back up drive parameters and document any changes made during commissioning.

The STO function should be tested according to the machine’s safety validation schedule. Any changes to safety wiring, drive hardware, or firmware should be assessed by qualified personnel before the system returns to operation.

Conclusion

The Siemens 6AG1244-0BB12-2BA1 SIPLUS G120 CU240E-2 USS Control Unit is a specialized control component for SINAMICS G120 variable frequency drive systems. It combines RS-485 USS communication, integrated digital and analog I/O, Safety Integrated STO, and SIPLUS conformal coating in a compact industrial design.

With its extended operating-temperature range and compatibility with the modular SINAMICS G120 platform, it is suitable for drive installations requiring dependable motor-control coordination and serial communication. Correct Power Module matching, firmware verification, communication configuration, and safety validation are essential for reliable operation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)