Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The GE IC697CMM742-LL Ethernet Interface Module is a Type 2 industrial communication module designed for GE Fanuc Series 90-70 programmable logic controller systems. It provides Ethernet connectivity for PLC communication, allowing compatible controllers to exchange data with industrial computers, supervisory systems, programming workstations, and other network-connected automation equipment.
In industrial automation, communication between controllers and supervisory devices is essential for coordinated production, equipment monitoring, and process management. The IC697CMM742-LL provides an Ethernet interface for Series 90-70 PLC systems, supporting data exchange and programming-related services over compatible Ethernet networks.
This module supports TCP/IP communication services through SRTP (Service Request Transport Protocol) and Ethernet Global Data (EGD). These communication capabilities allow the PLC to exchange application data with compatible devices and provide access to programming, configuration, and diagnostic functions.
The IC697CMM742-LL belongs to the Type 2 Ethernet Interface family. Its network connections include 10BASE-T, 10BASE-2, and an AUI interface. These different connection options provide flexibility when maintaining older industrial Ethernet installations or integrating the PLC into an existing network infrastructure.
The module is installed in a single slot of a compatible Series 90-70 PLC CPU rack. It also includes diagnostic indicators and serial connections used for station management and service functions.
Because the Series 90-70 platform is a legacy automation system, compatibility should be checked carefully before purchasing or replacing this module. CPU firmware, rack configuration, network media, and communication settings can all affect system operation.
| Parameter | Specification |
|---|---|
| Brand | GE |
| Manufacturer | GE Fanuc / GE Intelligent Platforms |
| Model | IC697CMM742-LL |
| Product Series | Series 90-70 |
| Product Type | Ethernet Interface Module |
| Module Type | Type 2 Ethernet Interface |
| Primary Function | PLC Ethernet Communication |
| Communication Protocols | TCP/IP, SRTP, EGD |
| Ethernet Standard | IEEE 802.3 |
| Network Data Rate | 10 Mbps |
| Network Interfaces | 10BASE-T, 10BASE-2, AUI |
| 10BASE-T Connector | RJ-45 |
| 10BASE-2 Connector | BNC |
| AUI Connector | 15-pin D-sub |
| Serial Interfaces | RS-232 and RS-485 service connections |
| Installation | Single slot in Series 90-70 CPU rack |
| Typical Backplane Power | +5 V DC, 2.0 A |
| Status Indicators | Module OK, LAN Online, Serial Active, Status |
| Redundancy | Not supported |
| Dimensions | 233 × 41 × 175 mm |
| Weight | 0.522 kg |
| Application | Industrial PLC networking and data exchange |
Note: Specifications should be checked against the exact hardware revision and the documentation for the installed Series 90-70 system.
The IC697CMM742-LL functions as an Ethernet communication interface for the Series 90-70 PLC. It connects the controller to an industrial network and provides the communication services required for data exchange, PLC configuration, and system diagnostics.
The module provides three Ethernet connection options:
The module automatically selects the network port in use. Only one of these network interfaces is used at a time.
This flexibility is particularly useful when maintaining older industrial installations where network infrastructure may include different Ethernet media.
The module provides TCP/IP communication services through SRTP. This allows compatible devices to exchange data with the Series 90-70 PLC over an Ethernet network.
In a typical industrial installation, a supervisory computer or HMI system can obtain PLC information through a compatible communication driver. The PLC can then participate in a wider automation network without requiring every supervisory device to connect directly to individual field signals.
The IC697CMM742 supports Ethernet Global Data, commonly known as EGD.
EGD is used for exchanging application data between compatible industrial controllers and network devices. Depending on the system configuration, this can support communication between PLCs, coordinated machine operation, and the distribution of selected process information.
EGD configuration should be planned carefully to ensure that the correct data variables, exchange settings, and communication parameters are used.
The Ethernet Interface Type 2 supports PLC programming and configuration services. This allows compatible engineering workstations to communicate with the controller through the network.
Engineers can use the supported programming environment to configure the PLC and maintain the automation application. Network access can also reduce the need for repeated physical connections to the controller during maintenance.
The programming software and CPU firmware must be compatible with the installed communication module.
The module includes station management functions and status indicators to assist maintenance personnel in evaluating communication conditions.
The indicators provide information about module operation, network status, and serial activity. These visual signals can help technicians distinguish between a module-level problem and a network connection issue.
The serial service interfaces also support maintenance and configuration activities according to the applicable station management procedures.
The IC697CMM742-LL serves as a communication link between the Series 90-70 PLC and other compatible industrial devices.
A PLC typically receives field signals, executes control logic, and manages machine operation. However, industrial automation systems also require communication with supervisory computers, engineering workstations, and other controllers.
The Ethernet Interface module provides the network connection needed for these communication tasks.
SCADA and HMI systems use controller data to display process conditions, equipment status, alarms, and operating information.
Through compatible communication drivers, the IC697CMM742 can provide network access to Series 90-70 PLC data. This allows operators and maintenance engineers to monitor equipment without relying exclusively on local controller indicators.
The actual integration depends on the software driver, PLC configuration, and network architecture.
In installations containing multiple PLCs, communication between controllers can support coordinated machine operation.
EGD provides a mechanism for exchanging configured application data between compatible devices. This can be useful when different production areas need to share operating states, process values, or coordination signals.
The module supports programming and configuration services over Ethernet. This can simplify maintenance activities when the engineering workstation and PLC are connected to the same compatible network.
For older installations, maintaining the correct firmware and communication software versions is especially important.
The GE IC697CMM742-LL is designed for industrial automation systems using the Series 90-70 PLC platform.
Manufacturing facilities often use multiple PLC-controlled machines operating as part of a coordinated production line.
The IC697CMM742-LL provides Ethernet connectivity for exchanging controller data with compatible supervisory and engineering systems. This supports centralized monitoring and production coordination.
Industrial process facilities rely on continuous communication between controllers and supervisory equipment.
The module can provide network access to Series 90-70 PLC data, supporting monitoring of process conditions and communication with compatible control-system software.
Packaging lines, conveyors, and material-handling equipment often require communication between separate machine-control systems.
The module’s Ethernet communication functions can support data exchange between compatible PLCs and supervisory devices, helping coordinate equipment operation.
Power generation and utility installations may contain legacy PLC systems responsible for auxiliary equipment and supporting processes.
The IC697CMM742-LL can provide Ethernet communication for compatible Series 90-70 installations, allowing controller information to be accessed by engineering and supervisory systems.
Many industrial facilities continue operating older control systems because the equipment remains functional and replacement can require significant engineering work.
The IC697CMM742-LL is relevant to maintenance projects involving existing Series 90-70 Ethernet networks. It can serve as a replacement communication module when the hardware revision, firmware requirements, and network configuration are compatible.
Correct installation is essential for reliable communication and stable PLC operation.
Before installation, confirm that the module is intended for the Series 90-70 PLC platform.
The Type 2 Ethernet Interface was designed for Series 90-70 CPU firmware version 6.00 and later to obtain its full capabilities. Restricted operation is documented for certain earlier CPU firmware versions, including versions 4.12 through 5.50.
CPU firmware compatibility should therefore be checked before replacing an existing communication module.
The IC697CMM742-LL occupies one slot in the main Series 90-70 CPU rack.
It should not be installed in an expansion rack. The manufacturer’s installation information identifies this as a restriction for the Ethernet Interface Type 2.
The system configuration should also respect the documented limit on the number of supported LAN interface modules in a single PLC.
Choose the network connection according to the existing infrastructure:
Only one network port is used at a time. Verify the selected interface, cable type, connector condition, and network equipment before powering up the system.
The module requires approximately 2.0 A from the +5 V DC backplane supply.
The AUI connection may also require +12 V DC when the module powers an external transceiver. The PLC power supply must therefore be checked against the requirements of the selected network interface.
An externally powered transceiver may be used in suitable configurations, subject to the applicable installation documentation.
After installation, configure the module using the appropriate Series 90-70 programming and communication software.
Check the network address, communication parameters, PLC configuration, and required SRTP or EGD settings.
For older systems, confirm that the engineering workstation software and CPU firmware support the installed module revision.
After configuration, verify that the module initializes correctly and that the network connection is active.
Check the status indicators, test communication with the engineering workstation, and confirm that the required PLC data can be accessed by the intended devices.
Document the network settings and configuration information for future maintenance.
The IC697CMM742-LL operates as part of a Series 90-70 PLC installation. Its associated components should be selected according to the system’s hardware and firmware requirements.
| Component | Function | Integration Considerations |
|---|---|---|
| GE Series 90-70 CPU | Executes PLC control logic | Confirm CPU model and firmware compatibility |
| IC697 PLC rack | Provides module installation and backplane connections | Install the module in the main CPU rack |
| GE PLC power supply | Supplies backplane power | Verify +5 V DC capacity and +12 V DC requirements where applicable |
| Engineering workstation | Supports PLC programming and configuration | Use compatible Series 90-70 programming software |
| Ethernet switch or hub | Connects compatible network devices | Confirm support for the required legacy Ethernet interface |
| 10BASE-T cable | Provides twisted-pair Ethernet connectivity | Use compatible cable and RJ-45 termination |
| 10BASE-2 coaxial cable | Provides legacy coaxial Ethernet connectivity | Check cable type and BNC termination |
| AUI transceiver | Connects the AUI port to supported Ethernet media | Verify IEEE 802.3 compatibility and power requirements |
| HMI or SCADA system | Displays PLC data and process information | Requires a compatible communication driver |
| Other compatible PLCs | Exchange application data | Configure supported SRTP or EGD communication |
The components listed above are typical integration elements. They are not necessarily included with the IC697CMM742-LL module.
The IC697CMM742-LL belongs to a legacy communication platform. Replacement selection should focus on the original PLC architecture and the communication functions required by the installation.
| Alternative or Related Model | Description | Replacement Considerations |
|---|---|---|
| IC697CMM742 | Series 90-70 Type 2 Ethernet Interface | Verify hardware revision and configuration compatibility |
| IC697CMM741 | Series 90-70 Ethernet Interface | Different interface generation; check system requirements |
| IC697CMM731 | Series 90-70 Ethernet communication module | Confirm communication functions and hardware compatibility |
| IC697CMM721 | Series 90-70 communication module | Not a direct Ethernet substitute; verify communication type |
| IC693CMM321 | Series 90-30 Ethernet Interface | Designed for a different PLC platform |
| IC695ETM001 | PACSystems RX3i Ethernet Interface | Requires an appropriate platform migration and engineering review |
When replacing the IC697CMM742-LL, engineers should verify:
A module from another GE PLC family should not be assumed to be a direct replacement simply because it provides Ethernet communication.
The module provides 10BASE-T, 10BASE-2, and AUI interfaces, supporting different network media used in legacy industrial Ethernet installations.
It enables compatible Series 90-70 controllers to exchange data with network-connected automation devices.
Support for SRTP and Ethernet Global Data provides communication options for PLC data exchange and supervisory integration.
The module supports network-based PLC programming and configuration functions, helping engineers maintain compatible controller installations.
Status LEDs provide useful information about module operation and network communication, assisting troubleshooting activities.
The IC697CMM742-LL can help maintain existing Series 90-70 automation systems where replacing the entire PLC architecture is not practical.
The GE IC697CMM742-LL is a Type 2 Ethernet Interface Module designed for GE Fanuc Series 90-70 PLC systems. It provides Ethernet communication between the PLC and compatible industrial devices.
The module supports TCP/IP communication services through SRTP and Ethernet Global Data (EGD). These functions support PLC data exchange, programming, and supervisory communication.
It provides three network connection options: 10BASE-T through an RJ-45 connector, 10BASE-2 through a BNC connector, and AUI through a 15-pin D-sub connector.
No. The module automatically selects the network port in use, and only one network interface is used at a time.
It is designed for the GE Fanuc Series 90-70 PLC platform. Verify the CPU model, firmware version, and rack configuration before installation.
CPU firmware version 6.00 or later is recommended for full Type 2 Ethernet Interface functionality. Certain earlier firmware versions support restricted operation, so compatibility should be confirmed using the relevant documentation.
The module should be installed in a single slot of the main Series 90-70 CPU rack. It should not be installed in an expansion rack.
The module supports 10 Mbps IEEE 802.3 Ethernet communication. It is a legacy Ethernet interface and should not be treated as a modern 100 Mbps or Gigabit Ethernet module.
Yes, it can provide PLC Ethernet communication for compatible SCADA and HMI systems through supported communication drivers. The actual integration depends on the software, PLC configuration, and network architecture.
Confirm the full catalog number, hardware revision, Series 90-70 CPU model, firmware version, network interface requirements, and the communication functions used by the existing installation. Also inspect the module’s connectors and physical condition.
The IC697CMM742-LL is intended for a legacy Series 90-70 PLC platform. Before purchasing, maintenance engineers should identify the installed module’s complete catalog number and revision rather than relying only on the general IC697CMM742 designation.
For replacement projects, confirm the CPU firmware version, main rack requirements, network connection type, and communication settings. If the existing system uses 10BASE-2 or AUI connections, verify that the replacement arrangement preserves the required network infrastructure.
For used or surplus modules, request clear photographs of the front panel, connectors, catalog label, and hardware revision. Check the condition of the RJ-45, BNC, AUI, and serial interfaces where applicable. Verify the module’s startup status and communication operation through an appropriate functional test.
During maintenance, monitor the module status indicators and inspect network cables and connectors for physical damage. Keep the PLC rack clean and ensure that the backplane power supply meets the module’s requirements.
It is also advisable to document the network configuration, PLC firmware version, and communication settings. This information can reduce troubleshooting time and simplify future module replacement.
The GE IC697CMM742-LL Ethernet Interface Module is a Type 2 communication module designed for GE Fanuc Series 90-70 PLC systems. It provides 10BASE-T, 10BASE-2, and AUI network connections, together with SRTP and EGD communication capabilities.
Its functions support PLC data exchange, programming, configuration, and industrial network diagnostics. For existing Series 90-70 installations, the module can be an important component in maintaining communication between controllers and supervisory equipment.
Because it is a legacy 10 Mbps Ethernet interface, careful attention should be given to CPU firmware compatibility, rack installation, network media, and communication configuration when purchasing or replacing the IC697CMM742-LL.