Product Overview The GE IC697CMM742-LL Ethernet Interface Module is a Type 2 industrial communication module designed for GE Fanuc Series 90-70 programmable logic controller systems. It provides Etherne……
GE IC697CMM742-LL Ethernet Interface Module
  • GE
  • IC697CMM742-LL
  • Ethernet Interface Module
  • USA
  • 233 × 41 × 175 mm
  • 0.522 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 38

Our advantage

GE IC697CMM742-LL Ethernet Interface Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IC697CMM742-LL Ethernet Interface Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IC697CMM742-LL Ethernet Interface Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IC697CMM742-LL Ethernet Interface Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IC697CMM742-LL Ethernet Interface Module is a Type 2 industrial communication module designed for GE Fanuc Series 90-70 programmable logic controller systems. It provides Ethernet connectivity for PLC communication, allowing compatible controllers to exchange data with industrial computers, supervisory systems, programming workstations, and other network-connected automation equipment.

In industrial automation, communication between controllers and supervisory devices is essential for coordinated production, equipment monitoring, and process management. The IC697CMM742-LL provides an Ethernet interface for Series 90-70 PLC systems, supporting data exchange and programming-related services over compatible Ethernet networks.

This module supports TCP/IP communication services through SRTP (Service Request Transport Protocol) and Ethernet Global Data (EGD). These communication capabilities allow the PLC to exchange application data with compatible devices and provide access to programming, configuration, and diagnostic functions.

The IC697CMM742-LL belongs to the Type 2 Ethernet Interface family. Its network connections include 10BASE-T, 10BASE-2, and an AUI interface. These different connection options provide flexibility when maintaining older industrial Ethernet installations or integrating the PLC into an existing network infrastructure.

The module is installed in a single slot of a compatible Series 90-70 PLC CPU rack. It also includes diagnostic indicators and serial connections used for station management and service functions.

Because the Series 90-70 platform is a legacy automation system, compatibility should be checked carefully before purchasing or replacing this module. CPU firmware, rack configuration, network media, and communication settings can all affect system operation.

Technical Specifications

Parameter Specification
Brand GE
Manufacturer GE Fanuc / GE Intelligent Platforms
Model IC697CMM742-LL
Product Series Series 90-70
Product Type Ethernet Interface Module
Module Type Type 2 Ethernet Interface
Primary Function PLC Ethernet Communication
Communication Protocols TCP/IP, SRTP, EGD
Ethernet Standard IEEE 802.3
Network Data Rate 10 Mbps
Network Interfaces 10BASE-T, 10BASE-2, AUI
10BASE-T Connector RJ-45
10BASE-2 Connector BNC
AUI Connector 15-pin D-sub
Serial Interfaces RS-232 and RS-485 service connections
Installation Single slot in Series 90-70 CPU rack
Typical Backplane Power +5 V DC, 2.0 A
Status Indicators Module OK, LAN Online, Serial Active, Status
Redundancy Not supported
Dimensions 233 × 41 × 175 mm
Weight 0.522 kg
Application Industrial PLC networking and data exchange

Note: Specifications should be checked against the exact hardware revision and the documentation for the installed Series 90-70 system.

Function and Working Principle

The IC697CMM742-LL functions as an Ethernet communication interface for the Series 90-70 PLC. It connects the controller to an industrial network and provides the communication services required for data exchange, PLC configuration, and system diagnostics.

1. Ethernet Network Connectivity

The module provides three Ethernet connection options:

  • 10BASE-T: Uses an RJ-45 connector for connection to compatible twisted-pair Ethernet network equipment.
  • 10BASE-2: Uses a BNC connector for compatible coaxial Ethernet networks.
  • AUI: Uses a 15-pin D-sub connector to connect an external Ethernet transceiver.

The module automatically selects the network port in use. Only one of these network interfaces is used at a time.

This flexibility is particularly useful when maintaining older industrial installations where network infrastructure may include different Ethernet media.

2. TCP/IP Communication

The module provides TCP/IP communication services through SRTP. This allows compatible devices to exchange data with the Series 90-70 PLC over an Ethernet network.

In a typical industrial installation, a supervisory computer or HMI system can obtain PLC information through a compatible communication driver. The PLC can then participate in a wider automation network without requiring every supervisory device to connect directly to individual field signals.

3. Ethernet Global Data

The IC697CMM742 supports Ethernet Global Data, commonly known as EGD.

EGD is used for exchanging application data between compatible industrial controllers and network devices. Depending on the system configuration, this can support communication between PLCs, coordinated machine operation, and the distribution of selected process information.

EGD configuration should be planned carefully to ensure that the correct data variables, exchange settings, and communication parameters are used.

4. PLC Programming and Configuration

The Ethernet Interface Type 2 supports PLC programming and configuration services. This allows compatible engineering workstations to communicate with the controller through the network.

Engineers can use the supported programming environment to configure the PLC and maintain the automation application. Network access can also reduce the need for repeated physical connections to the controller during maintenance.

The programming software and CPU firmware must be compatible with the installed communication module.

5. Station Management and Diagnostics

The module includes station management functions and status indicators to assist maintenance personnel in evaluating communication conditions.

The indicators provide information about module operation, network status, and serial activity. These visual signals can help technicians distinguish between a module-level problem and a network connection issue.

The serial service interfaces also support maintenance and configuration activities according to the applicable station management procedures.

Role in Industrial Control Systems

The IC697CMM742-LL serves as a communication link between the Series 90-70 PLC and other compatible industrial devices.

PLC Network Communication

A PLC typically receives field signals, executes control logic, and manages machine operation. However, industrial automation systems also require communication with supervisory computers, engineering workstations, and other controllers.

The Ethernet Interface module provides the network connection needed for these communication tasks.

SCADA and HMI Integration

SCADA and HMI systems use controller data to display process conditions, equipment status, alarms, and operating information.

Through compatible communication drivers, the IC697CMM742 can provide network access to Series 90-70 PLC data. This allows operators and maintenance engineers to monitor equipment without relying exclusively on local controller indicators.

The actual integration depends on the software driver, PLC configuration, and network architecture.

Controller-to-Controller Data Exchange

In installations containing multiple PLCs, communication between controllers can support coordinated machine operation.

EGD provides a mechanism for exchanging configured application data between compatible devices. This can be useful when different production areas need to share operating states, process values, or coordination signals.

Engineering and Maintenance Access

The module supports programming and configuration services over Ethernet. This can simplify maintenance activities when the engineering workstation and PLC are connected to the same compatible network.

For older installations, maintaining the correct firmware and communication software versions is especially important.

Industrial Applications

The GE IC697CMM742-LL is designed for industrial automation systems using the Series 90-70 PLC platform.

1. Manufacturing Automation

Manufacturing facilities often use multiple PLC-controlled machines operating as part of a coordinated production line.

The IC697CMM742-LL provides Ethernet connectivity for exchanging controller data with compatible supervisory and engineering systems. This supports centralized monitoring and production coordination.

2. Process Control Systems

Industrial process facilities rely on continuous communication between controllers and supervisory equipment.

The module can provide network access to Series 90-70 PLC data, supporting monitoring of process conditions and communication with compatible control-system software.

3. Packaging and Material Handling

Packaging lines, conveyors, and material-handling equipment often require communication between separate machine-control systems.

The module’s Ethernet communication functions can support data exchange between compatible PLCs and supervisory devices, helping coordinate equipment operation.

4. Power and Utility Facilities

Power generation and utility installations may contain legacy PLC systems responsible for auxiliary equipment and supporting processes.

The IC697CMM742-LL can provide Ethernet communication for compatible Series 90-70 installations, allowing controller information to be accessed by engineering and supervisory systems.

5. Legacy Industrial Network Maintenance

Many industrial facilities continue operating older control systems because the equipment remains functional and replacement can require significant engineering work.

The IC697CMM742-LL is relevant to maintenance projects involving existing Series 90-70 Ethernet networks. It can serve as a replacement communication module when the hardware revision, firmware requirements, and network configuration are compatible.

Installation and System Integration

Correct installation is essential for reliable communication and stable PLC operation.

1. Verify PLC Compatibility

Before installation, confirm that the module is intended for the Series 90-70 PLC platform.

The Type 2 Ethernet Interface was designed for Series 90-70 CPU firmware version 6.00 and later to obtain its full capabilities. Restricted operation is documented for certain earlier CPU firmware versions, including versions 4.12 through 5.50.

CPU firmware compatibility should therefore be checked before replacing an existing communication module.

2. Install in the Correct Rack

The IC697CMM742-LL occupies one slot in the main Series 90-70 CPU rack.

It should not be installed in an expansion rack. The manufacturer’s installation information identifies this as a restriction for the Ethernet Interface Type 2.

The system configuration should also respect the documented limit on the number of supported LAN interface modules in a single PLC.

3. Select the Appropriate Network Interface

Choose the network connection according to the existing infrastructure:

  • Use 10BASE-T for compatible twisted-pair Ethernet connections.
  • Use 10BASE-2 for compatible coaxial Ethernet networks.
  • Use AUI with an appropriate external transceiver when required.

Only one network port is used at a time. Verify the selected interface, cable type, connector condition, and network equipment before powering up the system.

4. Check Power Requirements

The module requires approximately 2.0 A from the +5 V DC backplane supply.

The AUI connection may also require +12 V DC when the module powers an external transceiver. The PLC power supply must therefore be checked against the requirements of the selected network interface.

An externally powered transceiver may be used in suitable configurations, subject to the applicable installation documentation.

5. Configure Network Communication

After installation, configure the module using the appropriate Series 90-70 programming and communication software.

Check the network address, communication parameters, PLC configuration, and required SRTP or EGD settings.

For older systems, confirm that the engineering workstation software and CPU firmware support the installed module revision.

6. Test Communication and Diagnostics

After configuration, verify that the module initializes correctly and that the network connection is active.

Check the status indicators, test communication with the engineering workstation, and confirm that the required PLC data can be accessed by the intended devices.

Document the network settings and configuration information for future maintenance.

Compatible System Components

The IC697CMM742-LL operates as part of a Series 90-70 PLC installation. Its associated components should be selected according to the system’s hardware and firmware requirements.

Component Function Integration Considerations
GE Series 90-70 CPU Executes PLC control logic Confirm CPU model and firmware compatibility
IC697 PLC rack Provides module installation and backplane connections Install the module in the main CPU rack
GE PLC power supply Supplies backplane power Verify +5 V DC capacity and +12 V DC requirements where applicable
Engineering workstation Supports PLC programming and configuration Use compatible Series 90-70 programming software
Ethernet switch or hub Connects compatible network devices Confirm support for the required legacy Ethernet interface
10BASE-T cable Provides twisted-pair Ethernet connectivity Use compatible cable and RJ-45 termination
10BASE-2 coaxial cable Provides legacy coaxial Ethernet connectivity Check cable type and BNC termination
AUI transceiver Connects the AUI port to supported Ethernet media Verify IEEE 802.3 compatibility and power requirements
HMI or SCADA system Displays PLC data and process information Requires a compatible communication driver
Other compatible PLCs Exchange application data Configure supported SRTP or EGD communication

The components listed above are typical integration elements. They are not necessarily included with the IC697CMM742-LL module.

Alternative Models and Replacement Considerations

The IC697CMM742-LL belongs to a legacy communication platform. Replacement selection should focus on the original PLC architecture and the communication functions required by the installation.

Alternative or Related Model Description Replacement Considerations
IC697CMM742 Series 90-70 Type 2 Ethernet Interface Verify hardware revision and configuration compatibility
IC697CMM741 Series 90-70 Ethernet Interface Different interface generation; check system requirements
IC697CMM731 Series 90-70 Ethernet communication module Confirm communication functions and hardware compatibility
IC697CMM721 Series 90-70 communication module Not a direct Ethernet substitute; verify communication type
IC693CMM321 Series 90-30 Ethernet Interface Designed for a different PLC platform
IC695ETM001 PACSystems RX3i Ethernet Interface Requires an appropriate platform migration and engineering review

When replacing the IC697CMM742-LL, engineers should verify:

  • Complete catalog number and hardware revision.
  • Series 90-70 CPU model.
  • CPU firmware version.
  • Main rack installation requirements.
  • Network connector and cable type.
  • SRTP and EGD communication requirements.
  • PLC programming software compatibility.
  • Network configuration and addressing.
  • Backplane power capacity.
  • Existing HMI and SCADA communication drivers.

A module from another GE PLC family should not be assumed to be a direct replacement simply because it provides Ethernet communication.

Key Advantages

Multiple Network Connection Options

The module provides 10BASE-T, 10BASE-2, and AUI interfaces, supporting different network media used in legacy industrial Ethernet installations.

Industrial PLC Communication

It enables compatible Series 90-70 controllers to exchange data with network-connected automation devices.

SRTP and EGD Support

Support for SRTP and Ethernet Global Data provides communication options for PLC data exchange and supervisory integration.

Programming and Configuration Services

The module supports network-based PLC programming and configuration functions, helping engineers maintain compatible controller installations.

Integrated Diagnostic Indicators

Status LEDs provide useful information about module operation and network communication, assisting troubleshooting activities.

Legacy System Maintenance

The IC697CMM742-LL can help maintain existing Series 90-70 automation systems where replacing the entire PLC architecture is not practical.

Technical FAQs

1. What is the GE IC697CMM742-LL?

The GE IC697CMM742-LL is a Type 2 Ethernet Interface Module designed for GE Fanuc Series 90-70 PLC systems. It provides Ethernet communication between the PLC and compatible industrial devices.

2. What communication protocols does this module support?

The module supports TCP/IP communication services through SRTP and Ethernet Global Data (EGD). These functions support PLC data exchange, programming, and supervisory communication.

3. What Ethernet ports are available?

It provides three network connection options: 10BASE-T through an RJ-45 connector, 10BASE-2 through a BNC connector, and AUI through a 15-pin D-sub connector.

4. Can all three Ethernet ports operate simultaneously?

No. The module automatically selects the network port in use, and only one network interface is used at a time.

5. Which PLC platform is compatible with the IC697CMM742-LL?

It is designed for the GE Fanuc Series 90-70 PLC platform. Verify the CPU model, firmware version, and rack configuration before installation.

6. Which CPU firmware version is recommended?

CPU firmware version 6.00 or later is recommended for full Type 2 Ethernet Interface functionality. Certain earlier firmware versions support restricted operation, so compatibility should be confirmed using the relevant documentation.

7. Where should the module be installed?

The module should be installed in a single slot of the main Series 90-70 CPU rack. It should not be installed in an expansion rack.

8. What is the network speed?

The module supports 10 Mbps IEEE 802.3 Ethernet communication. It is a legacy Ethernet interface and should not be treated as a modern 100 Mbps or Gigabit Ethernet module.

9. Can the IC697CMM742-LL communicate with SCADA systems?

Yes, it can provide PLC Ethernet communication for compatible SCADA and HMI systems through supported communication drivers. The actual integration depends on the software, PLC configuration, and network architecture.

10. What should be checked before purchasing a replacement?

Confirm the full catalog number, hardware revision, Series 90-70 CPU model, firmware version, network interface requirements, and the communication functions used by the existing installation. Also inspect the module’s connectors and physical condition.

Procurement and Maintenance Recommendations

The IC697CMM742-LL is intended for a legacy Series 90-70 PLC platform. Before purchasing, maintenance engineers should identify the installed module’s complete catalog number and revision rather than relying only on the general IC697CMM742 designation.

For replacement projects, confirm the CPU firmware version, main rack requirements, network connection type, and communication settings. If the existing system uses 10BASE-2 or AUI connections, verify that the replacement arrangement preserves the required network infrastructure.

For used or surplus modules, request clear photographs of the front panel, connectors, catalog label, and hardware revision. Check the condition of the RJ-45, BNC, AUI, and serial interfaces where applicable. Verify the module’s startup status and communication operation through an appropriate functional test.

During maintenance, monitor the module status indicators and inspect network cables and connectors for physical damage. Keep the PLC rack clean and ensure that the backplane power supply meets the module’s requirements.

It is also advisable to document the network configuration, PLC firmware version, and communication settings. This information can reduce troubleshooting time and simplify future module replacement.

Conclusion

The GE IC697CMM742-LL Ethernet Interface Module is a Type 2 communication module designed for GE Fanuc Series 90-70 PLC systems. It provides 10BASE-T, 10BASE-2, and AUI network connections, together with SRTP and EGD communication capabilities.

Its functions support PLC data exchange, programming, configuration, and industrial network diagnostics. For existing Series 90-70 installations, the module can be an important component in maintaining communication between controllers and supervisory equipment.

Because it is a legacy 10 Mbps Ethernet interface, careful attention should be given to CPU firmware compatibility, rack installation, network media, and communication configuration when purchasing or replacing the IC697CMM742-LL.