• Schneider NW12HA Circuit Breaker
  • Schneider NW12HA Circuit Breaker
  • Schneider NW12HA Circuit Breaker
  • Schneider NW12HA Circuit Breaker
Product Overview The Schneider NW12HA MasterPact Switch Disconnector is a high-current switching and isolation device designed for low-voltage power distribution systems. It belongs to the MasterPact NW……
Schneider NW12HA Circuit Breaker
  • Schneider
  • NW12HA
  • Circuit Breaker
  • France
  • 442 x 352 x 297 mm
  • 60 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Schneider NW12HA Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW12HA Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW12HA Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW12HA Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider NW12HA MasterPact Switch Disconnector is a high-current switching and isolation device designed for low-voltage power distribution systems. It belongs to the MasterPact NW family and is intended for industrial and commercial electrical installations where reliable circuit switching and isolation are essential.

With a rated operational current of 1250 A and an operational voltage of up to 690 V AC, the NW12HA is designed for demanding power distribution applications. Its three-pole configuration makes it suitable for switching and isolating three-phase electrical circuits in main distribution boards, power control centers, and industrial switchgear assemblies.

An important distinction is that the NW12HA is a switch disconnector rather than a conventional automatic circuit breaker with an integrated overcurrent trip unit. It provides switching and isolation functions, but overcurrent and short-circuit protection must be provided by an appropriately coordinated protective device or system.

The NW12HA uses a fixed mounting arrangement and push-button operation. Its design supports controlled electrical isolation during maintenance and switching operations. The device also provides a contact position indicator, allowing personnel to identify the operating position during normal operation and maintenance procedures.

For industrial facilities, the correct selection of a switch disconnector is important for electrical safety, system availability, and maintenance planning. The NW12HA is intended for installations where high-current circuit isolation and switching are required within a properly engineered low-voltage distribution system.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family MasterPact NW
Model NW12HA
Product Type Switch Disconnector
Device Application Power Distribution and Isolation
Rated Operational Current 1250 A
Rated Operational Voltage Up to 690 V AC
Network Type AC
Network Frequency 50/60 Hz
Number of Poles 3P
Mounting Mode Fixed
Control Type Push-button
Breaking Capacity Code HA
Rated Insulation Voltage 1000 V AC
Rated Impulse Withstand Voltage 12 kV
Rated Short-Circuit Making Capacity 143 kA
Rated Short-Time Withstand Current 65 kA for 1 second
Rated Short-Time Withstand Current 36 kA for 3 seconds
Suitability for Isolation Yes
Contact Position Indicator Yes
Visible Break No
Connection Pitch 115 mm
Mechanical Durability 12,500 cycles without maintenance; 25,000 cycles with maintenance
Dimensions 442 × 352 × 297 mm
Weight 60 kg
Typical Application Industrial Low-Voltage Power Distribution

Note: The NW12HA is a switch disconnector. Its switching and isolation functions should not be confused with the automatic overcurrent protection provided by a circuit breaker equipped with a suitable trip unit.

Function and Working Principle

The Schneider NW12HA is designed to establish, carry, and interrupt electrical current under its specified operating conditions. Its main purpose is to provide controlled switching and isolation within a power distribution system.

1. Electrical Circuit Switching

The switch disconnector uses an internal contact mechanism to connect or disconnect the electrical circuit. When the device is in the closed position, its contacts establish the electrical path between the incoming and outgoing terminals.

When operated to the open position, the contacts separate and interrupt the circuit according to the device’s rated switching capability.

This function is important in industrial installations where electrical distribution sections need to be switched for operational control, maintenance, or equipment isolation.

2. Power Isolation

Electrical isolation is an important requirement during inspection, maintenance, and equipment replacement.

The NW12HA is suitable for isolation according to IEC 60947-3. It allows an electrical circuit to be disconnected from its supply when the appropriate operating and safety procedures are followed.

However, the device does not provide a visible break. Personnel should therefore follow the required electrical safety procedures, including verification of absence of voltage and application of appropriate lockout and tagging practices.

3. High-Current Operation

With a rated operational current of 1250 A, the NW12HA is intended for high-current distribution applications.

Its internal contact system is designed to carry the specified current under the manufacturer’s operating conditions. Correct conductor sizing, terminal connections, ambient temperature, and switchgear installation are important for maintaining reliable electrical performance.

4. Short-Circuit Making Capability

The NW12HA has a published short-circuit making capacity of 143 kA under the specified voltage and operating conditions.

This rating describes its ability to close onto a circuit under the applicable short-circuit conditions. It should not be interpreted as an automatic short-circuit interruption rating.

The switch disconnector must be coordinated with suitable overcurrent protection, such as an appropriately rated protective circuit breaker, relay-controlled arrangement, or fuse system.

5. Mechanical Switching Operation

The NW12HA uses push-button control and a mechanical operating mechanism. Its contact system is designed for repeated switching within the specified operating limits.

Mechanical durability is rated at 12,500 cycles without maintenance and 25,000 cycles with maintenance under the specified conditions.

Regular inspection and maintenance are important for maintaining the operating mechanism, contact condition, and connection reliability.

Role in Industrial Power Distribution Systems

The NW12HA can serve as an important switching and isolation component in industrial electrical distribution systems. It is commonly considered for applications where high-current circuits need to be controlled and isolated as part of a coordinated power distribution arrangement.

Main Distribution Boards

In a main distribution board, the NW12HA can provide switching and isolation for a three-phase distribution section.

It may be installed in a main incoming or outgoing circuit arrangement, depending on the electrical design and protective-device coordination.

Power Control Centers

Industrial power control centers distribute electrical energy to multiple production areas, motor control centers, and auxiliary systems.

A high-current switch disconnector can provide a defined switching point for a distribution section, helping maintenance personnel isolate equipment when required.

Transformer Secondary Distribution

The NW12HA may be used in a suitable transformer secondary distribution arrangement where the rated current, voltage, and short-circuit conditions meet its specifications.

The overall design must include appropriate protection against overloads and short circuits. The switch disconnector itself should not be treated as a substitute for a protective circuit breaker.

Industrial Electrical Isolation

Industrial plants often require electrical isolation during maintenance, inspection, and equipment replacement.

The NW12HA provides a switching and isolation function within the distribution system. Its contact position indicator helps personnel identify the device’s operating state, although electrical testing and formal isolation procedures remain essential.

Industrial Applications

The Schneider NW12HA is intended for high-current low-voltage distribution installations. Its 1250 A rating and three-pole configuration make it relevant to a range of industrial and commercial electrical systems.

1. Manufacturing Plants

Manufacturing facilities contain large electrical distribution networks supplying production machinery, motor control centers, auxiliary equipment, and building services.

The NW12HA can be used as a switching and isolation component in a suitable distribution section. It helps provide a controlled point for disconnecting electrical equipment during planned maintenance.

2. Industrial Power Distribution

Large industrial facilities often use main switchboards to distribute electrical energy to different production areas.

The NW12HA can be incorporated into an appropriately designed three-phase distribution arrangement where its rated current and voltage match the installation requirements.

3. Commercial Buildings

Large commercial buildings may contain substantial electrical distribution systems supplying HVAC equipment, elevators, lighting systems, and other building services.

A high-current switch disconnector can provide an isolation point for a suitable distribution circuit.

4. Data Centers

Data centers require carefully coordinated electrical distribution systems to maintain power availability for servers, cooling equipment, and supporting infrastructure.

The NW12HA may be considered for suitable distribution and isolation duties within a properly engineered low-voltage switchboard.

Its use must be evaluated alongside the facility’s protection coordination, redundancy design, and operational switching procedures.

5. Infrastructure and Utility Facilities

Infrastructure installations, including transportation facilities and industrial utility buildings, may use high-current switching equipment in their low-voltage distribution systems.

The NW12HA can support circuit isolation and switching where the electrical design matches its ratings and installation requirements.

Installation and System Integration

Correct installation is essential for electrical safety, reliable switching, and long-term operating performance.

1. Verify Electrical Ratings

Before installation, confirm that the electrical system matches the device’s rated operational current and voltage.

The NW12HA has a rated operational current of 1250 A and an operational voltage of up to 690 V AC. Engineers should also evaluate the available short-circuit current and ensure that the complete protection arrangement is properly coordinated.

2. Confirm Mounting Requirements

The supplied dimensions are 442 × 352 × 297 mm, and the device weighs approximately 60 kg.

The installation structure must be suitable for supporting the device and maintaining correct alignment with the switchgear assembly.

Allow sufficient space for conductor connections, operating access, inspection, and maintenance. Confirm the manufacturer’s installation drawings before designing or modifying the switchboard.

3. Electrical Connection

Incoming and outgoing conductors must be selected according to the rated current, installation conditions, and applicable electrical standards.

Ensure that terminal connections are properly prepared and tightened according to the manufacturer’s instructions.

Incorrect connections can cause excessive contact resistance, overheating, and premature equipment deterioration.

4. Protection Coordination

The NW12HA is a switch disconnector and does not replace an automatic circuit breaker with a suitable overcurrent trip unit.

The electrical system must include an appropriate protective arrangement to detect and clear overloads and short circuits.

Protection coordination should consider the system’s prospective short-circuit current, conductor capacity, upstream protection, and the switch disconnector’s rated making and short-time withstand capabilities.

5. Isolation and Safety Procedures

Before maintenance, follow the facility’s electrical isolation procedures.

These should include disconnecting the relevant supply, preventing unintended re-energization, applying lockout and tagging measures, and verifying the absence of voltage with an appropriate test instrument.

Because the NW12HA does not provide a visible break, personnel should not rely solely on the operating position indicator as proof that a circuit is electrically safe.

6. Commissioning and Inspection

After installation, inspect the mechanical operating mechanism, terminal connections, mounting structure, and electrical clearances.

Verify the device’s switching operation and confirm that the associated protection system functions as designed.

Record the installation details and maintenance history to support future inspection and equipment lifecycle management.

Compatible System Components

The NW12HA operates as part of a wider low-voltage power distribution arrangement. The following components may be used alongside it, depending on the electrical design.

Component Function Integration Considerations
Protective circuit breaker Provides overload and short-circuit protection Coordinate ratings and protection characteristics with the switch disconnector
Overcurrent relay Detects abnormal current conditions Must operate with a suitable interrupting device
Current transformer Provides current measurement signals Select according to system current and relay requirements
Low-voltage switchboard Houses and supports distribution equipment Confirm mounting compatibility and required clearances
Busbar system Distributes electrical power Verify current capacity, connection pitch, and thermal performance
Power distribution panel Supplies multiple downstream circuits Confirm system voltage, current, and protection coordination
Voltage measurement equipment Monitors electrical system voltage Select suitable measurement ratings and installation arrangements
Grounding system Provides an electrical safety reference Follow applicable grounding and bonding requirements
Auxiliary indication devices Provide operating-status information Confirm the available auxiliary contacts and accessory configuration

These are examples of components that may be incorporated into the same installation. Their availability and compatibility should be confirmed against the exact NW12HA configuration.

Alternative Models and Replacement Considerations

The MasterPact NW family includes different current ratings, performance levels, pole configurations, and mounting arrangements.

The following models may be considered when evaluating related equipment. They are not automatic replacements for the NW12HA.

Related Model Rated Frame Current Product Family Replacement Considerations
NW10HA 1000 A MasterPact NW Lower current rating; verify system requirements
NW12NA 1250 A MasterPact NW Different performance level and short-circuit ratings
NW12HA 1250 A MasterPact NW Original model
NW16HA 1600 A MasterPact NW Higher frame current; verify physical and electrical compatibility
NW20HA 2000 A MasterPact NW Higher current class and different installation requirements

Before replacing an NW12HA, engineers should compare:

  • Rated operational current.
  • Rated operational voltage.
  • Number of poles.
  • Short-circuit making capacity.
  • Short-time withstand current.
  • Fixed or drawout mounting arrangement.
  • Connection pitch and terminal configuration.
  • Mechanical dimensions and mounting clearances.
  • Operating mechanism and auxiliary accessories.
  • Protection coordination with upstream and downstream devices.

A related MasterPact model may have a different switching function or protection arrangement. Always confirm whether the replacement is a switch disconnector or an automatic circuit breaker.

Key Advantages

High-Current Distribution Capability

The 1250 A rated operational current makes the NW12HA suitable for appropriately designed high-current low-voltage distribution systems.

Three-Pole Switching

Its three-pole configuration supports switching and isolation of three-phase electrical circuits.

Isolation Suitability

The device is suitable for isolation under IEC 60947-3, supporting maintenance and controlled switching procedures.

High Short-Circuit Making Capacity

The published 143 kA short-circuit making capacity supports its use in appropriately coordinated electrical distribution systems.

Defined Mechanical Durability

The specified mechanical durability provides useful information for maintenance planning and equipment lifecycle evaluation.

Contact Position Indication

The contact position indicator helps personnel identify the device’s operating state during switching and inspection.

Industrial Switchgear Integration

Its MasterPact NW design makes it relevant to high-current switchgear and power distribution installations that meet the specified mounting and electrical requirements.

Technical FAQs

1. What is the Schneider NW12HA?

The Schneider NW12HA is a MasterPact NW switch disconnector designed for high-current low-voltage power distribution and electrical isolation.

2. What is the rated current of the NW12HA?

Its rated operational current is 1250 A.

3. What is the maximum rated operational voltage?

The published rated operational voltage is up to 690 V AC at 50/60 Hz.

4. Is the NW12HA a circuit breaker?

The NW12HA configuration identified in Schneider’s product documentation is a switch disconnector. It provides switching and isolation functions but should not be treated as an automatic circuit breaker with an integrated overcurrent trip unit.

5. How many poles does this model have?

The specified fixed-mounted NW12HA configuration is a three-pole device.

6. What is its short-circuit making capacity?

The published short-circuit making capacity is 143 kA under the specified operating conditions. This is a making-capacity rating, not an automatic short-circuit interruption rating.

7. Can it provide overload protection?

The switch disconnector itself does not provide the same integrated overload protection as an automatic circuit breaker with an appropriate trip unit. The installation requires a suitable coordinated protective arrangement.

8. What is the mounting type?

The specified model uses fixed mounting. Verify the exact mounting arrangement and switchgear compatibility before ordering.

9. What are the dimensions and weight?

The supplied dimensions are 442 × 352 × 297 mm, and the net weight is approximately 60 kg.

10. What should be checked before purchasing an NW12HA?

Confirm the complete model designation, three-pole configuration, rated current, voltage, mounting type, physical condition, accessories, and compatibility with the existing switchgear. Also verify that the installation includes suitable overcurrent and short-circuit protection.

Procurement and Maintenance Recommendations

When purchasing the Schneider NW12HA, verify the complete product designation and confirm that the required device is a switch disconnector rather than an automatic circuit breaker.

Check the rated current, operating voltage, pole configuration, mounting arrangement, short-circuit making capacity, and short-time withstand current. These characteristics determine whether the device is suitable for the intended distribution system.

For replacement projects, compare the physical dimensions and connection pitch with the existing switchgear. A device with the same current rating may still have different terminal arrangements, operating mechanisms, or mounting requirements.

For used or surplus equipment, inspect the contact system, operating mechanism, terminals, insulation condition, and external housing. Request clear product photographs and available inspection or test records where appropriate.

During maintenance, follow the manufacturer’s inspection requirements and the facility’s electrical safety procedures. Check for signs of overheating, loose connections, mechanical wear, and contamination. Any maintenance work must be performed by qualified personnel after the equipment has been safely isolated.

Conclusion

The Schneider NW12HA MasterPact switch disconnector is a 1250 A three-pole device designed for high-current low-voltage power distribution and electrical isolation. With a rated operational voltage of up to 690 V AC, a 143 kA short-circuit making capacity, and a fixed mounting configuration, it is intended for appropriately engineered industrial and commercial switchgear installations.

Its primary role is switching and isolation rather than automatic overcurrent protection. Correct coordination with protective circuit breakers, relays, or fuses is therefore essential. For procurement, maintenance, and replacement projects, verifying the complete model configuration and electrical system requirements helps ensure safe and reliable operation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501