Product Overview The Schneider Electric NW10HA MasterPact Switch Disconnector is a high-current switching device designed for low-voltage power distribution systems. It belongs to the MasterPact NW fami……
Schneider NW10HA Circuit Breaker
  • Schneider
  • NW10HA
  • Circuit Breaker
  • France
  • 442 x 352 x 297 mm
  • 90 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Schneider NW10HA Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW10HA Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW10HA Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW10HA Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW10HA MasterPact Switch Disconnector is a high-current switching device designed for low-voltage power distribution systems. It belongs to the MasterPact NW family and is intended for applications that require reliable connection, disconnection, and isolation of major electrical circuits.

The NW10HA has a rated operational current of 1000 A and a three-pole configuration. It is designed for AC power networks operating at 50/60 Hz, with a rated operational voltage of up to 690 V AC. Its large-frame construction makes it suitable for main distribution boards, industrial switchboards, and other high-current electrical installations.

An important characteristic of this model is its classification as a non-automatic switch disconnector. Unlike an automatic circuit breaker equipped with an overcurrent trip unit, the NW10HA does not independently provide automatic overload and short-circuit tripping protection. It is designed for switching and isolation duties and must be coordinated with suitable upstream or downstream protective devices where overcurrent protection is required.

The device is available in fixed and drawout installation arrangements, depending on the selected product configuration. Its switching and isolation functions make it relevant to industrial power distribution systems where equipment maintenance, circuit separation, and controlled power switching are important.

The NW10HA is part of the Schneider Electric MasterPact NW platform, which is used in demanding low-voltage distribution applications. When selecting this device, engineers should verify the exact mounting arrangement, pole configuration, electrical ratings, accessories, and coordination with the protection system.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family MasterPact NW
Model NW10HA
Product Type Switch Disconnector
Device Classification Non-automatic switch
Rated Operational Current 1000 A
Number of Poles 3P
Network Type AC
Network Frequency 50/60 Hz
Rated Operational Voltage Up to 690 V AC
Rated Insulation Voltage 1000 V AC
Rated Impulse Withstand Voltage 12 kV
Rated Short-Circuit Making Capacity 143 kA at 220–690 V AC
Rated Short-Time Withstand Current 65 kA for 1 second
Mounting Options Fixed or drawout, depending on configuration
Control Type Push-button
Suitability for Isolation Yes
Overcurrent Trip Unit Not included as a non-automatic switch
Dimensions Provided 442 × 352 × 297 mm
Weight Provided 90 kg
Manufacturer-Listed Net Weight Approximately 60 kg for the listed configuration
Typical Application Main low-voltage power distribution and circuit isolation

Note: The 90 kg weight is the supplied listing value. Schneider Electric’s product page for the corresponding NW10HA switch-disconnector configuration lists approximately 60 kg net weight. Confirm the exact mounting version and whether the supplied figure includes packaging or additional accessories.

Function and Working Principle

The NW10HA is designed to connect, disconnect, and isolate high-current AC circuits. It provides a controlled switching point within a power distribution system and allows electrical circuits to be separated for maintenance or operational purposes.

1. High-Current Circuit Switching

With a rated operational current of 1000 A, the NW10HA is designed for high-current distribution applications.

It can be installed in a main switchboard or distribution assembly to manage the connection of a major electrical feeder. Its three-pole design allows the three phases of a compatible AC circuit to be switched together.

The rated current must be considered alongside operating voltage, ambient temperature, installation conditions, and the characteristics of the connected electrical system.

2. Circuit Isolation

Isolation is an important function in industrial electrical installations. Before maintenance work is performed on downstream equipment, the relevant circuit must be safely separated from its power source.

The NW10HA is suitable for isolation in accordance with its specified ratings and applicable installation requirements. Its contact-position indication helps operators identify the switching state.

Isolation procedures must still follow the site’s electrical safety rules. Operators should verify the absence of hazardous voltage using approved procedures before beginning maintenance.

3. Short-Circuit Making and Withstand Capability

The NW10HA has specified short-circuit making and short-time withstand ratings. These characteristics describe its ability to withstand defined electrical stresses under specified test conditions.

They do not mean that the device automatically detects and interrupts every overload or short-circuit condition. Since the NW10HA is a non-automatic switch disconnector, a suitable protective device or coordinated protection arrangement must be provided separately.

Engineers should evaluate prospective fault current, protective-device coordination, and system selectivity before installing the unit.

4. Fixed and Drawout Installation

The MasterPact NW platform supports different mounting arrangements.

A fixed installation is mounted directly within the switchboard assembly. A drawout installation uses a compatible chassis arrangement, allowing the device to be moved between operating, test, and disconnected positions according to the design.

The selected mounting arrangement affects the required cabinet space, connection accessories, maintenance procedures, and replacement process. The exact product configuration should be confirmed before ordering.

5. Three-Phase Power Distribution

The three-pole arrangement is intended for switching the three phases of a compatible AC distribution circuit.

In industrial power systems, three-phase switching devices are commonly used for incoming feeders, distribution sections, and large electrical loads. The system design must account for grounding, neutral arrangements, and the applicable electrical standards.

Role in Industrial Power Distribution Systems

The NW10HA can serve as a major switching and isolation component within an industrial low-voltage distribution system.

Main Distribution Board

In a main distribution board, the device may be used as a switching point for a high-current feeder. It allows authorized personnel to connect or isolate the associated circuit according to the operating requirements of the facility.

The main distribution system must include suitable protective equipment to address overload and short-circuit conditions.

Power Distribution Panels

Large industrial facilities often distribute electrical power through several switchboards and distribution panels. The NW10HA can be used in an appropriately rated section to manage a major outgoing or incoming circuit.

Its 1000 A rating makes it relevant to installations where the connected feeder requires high-current switching capacity.

Generator and Transformer Distribution

Generator and transformer systems require coordinated switching and protection equipment. A switch disconnector such as the NW10HA may be incorporated into a distribution arrangement where circuit isolation and switching are required.

The device must be selected according to the system voltage, current, fault level, operating sequence, and protection design.

Industrial Maintenance and Isolation

Maintenance teams need reliable methods for separating electrical equipment from its power source. The NW10HA can provide an isolation point within a properly designed distribution system.

The device should be operated only by qualified personnel following approved switching procedures, interlocks, and lockout/tagout requirements.

Industrial Applications

1. Manufacturing Plants

Manufacturing facilities often use high-capacity distribution systems to supply production lines, large machinery, and auxiliary equipment.

The NW10HA can be incorporated into a main or secondary distribution board to provide switching and isolation for a compatible 1000 A feeder.

2. Industrial Power Distribution Rooms

Power distribution rooms contain switchboards, feeder sections, transformers, and other electrical equipment. A high-current switch disconnector can provide a controlled switching point within these installations.

Its suitability depends on the system’s rated voltage, current, fault level, and required switching duty.

3. Commercial and Infrastructure Facilities

Large commercial buildings and infrastructure facilities may use high-capacity low-voltage distribution systems to supply lighting, HVAC equipment, pumps, and other electrical loads.

The NW10HA may be used in a suitably engineered distribution assembly where its electrical ratings and switching functions meet the application requirements.

4. Generator Distribution Systems

Generator installations require equipment for managing electrical connections and isolating circuits during maintenance or operational changes.

The NW10HA may be incorporated into a generator distribution board when the system design requires a three-pole, 1000 A switch disconnector. Generator protection must be provided by suitable coordinated protective devices.

5. Transformer Secondary Distribution

Transformer secondary circuits can carry substantial current, particularly in industrial facilities with large electrical loads.

The NW10HA may be used as a switching and isolation component on a compatible transformer secondary feeder. Engineers must verify the available fault current and ensure that the associated protection system is correctly rated.

6. Data Centers and Critical Power Systems

Data centers require carefully designed power distribution systems to support servers, cooling equipment, and backup power infrastructure.

A high-current switch disconnector may be used at an appropriate distribution point to support circuit isolation and maintenance. Critical-power applications require additional redundancy, protection coordination, and operational procedures.

Installation and System Integration

Correct installation is essential for safe switching, electrical reliability, and long-term service performance.

1. Verify Electrical Ratings

Before installation, confirm that the system voltage, operating frequency, and load current are compatible with the NW10HA.

The device has a rated operational current of 1000 A and is designed for AC networks up to 690 V. These values must be checked against the actual system conditions.

Also verify the prospective short-circuit current and the ratings of the associated protective equipment.

2. Confirm the Mounting Configuration

Determine whether the required unit is fixed-mounted or drawout.

For drawout installations, confirm that the chassis, guide rails, connection arrangements, and mechanical interlocks are compatible with the selected switch disconnector.

Do not assume that fixed and drawout versions are interchangeable without additional equipment or modifications.

3. Check Cabinet Dimensions

The supplied dimensions are 442 × 352 × 297 mm. These should be checked against the manufacturer’s dimensional drawings for the exact configuration.

Allow sufficient space for electrical connections, operating mechanisms, ventilation, inspection, and maintenance access.

For drawout installations, additional cabinet space may be required for the chassis and operating positions.

4. Verify Busbar and Cable Connections

High-current connections require appropriate conductor sizing, mechanical support, and correct tightening procedures.

Check busbar dimensions, connection pitch, terminal compatibility, and the manufacturer’s specified tightening torque.

Poor connections can lead to excessive contact resistance, localized heating, and equipment damage.

5. Coordinate Overcurrent Protection

The NW10HA is a non-automatic switch disconnector. It should not be treated as a substitute for a circuit breaker with an appropriate trip unit.

A separate protective arrangement must be selected to provide the required overload and short-circuit protection. The protection design should consider fault levels, selectivity, system grounding, and the characteristics of the connected load.

6. Perform Commissioning Checks

Before energizing the equipment, qualified personnel should inspect mechanical mounting, electrical connections, grounding, operating mechanisms, and interlocks.

Confirm the open and closed positions, contact-position indication, and correct integration with the switchboard.

Commissioning should follow the manufacturer’s instructions and the site’s electrical safety procedures.

Compatible System Components

The NW10HA is normally integrated into a larger low-voltage distribution assembly. The following components may be used in the same system, depending on the electrical design.

Component Function Integration Considerations
MasterPact NW chassis Supports drawout installation Must match the exact frame and mounting configuration
Main distribution busbar Transfers high-current electrical power Verify current rating, dimensions, connection pitch, and temperature rise
Upstream circuit breaker Provides overcurrent and short-circuit protection Coordinate ratings and protection settings with the system
Overcurrent protection relay Detects abnormal current conditions Must operate with a suitable interrupting device
Current transformer Supplies current measurement signals Select suitable ratio, accuracy, and insulation rating
Voltage monitoring equipment Monitors distribution voltage Verify system voltage and measurement requirements
Switchboard control system Coordinates electrical switching and status monitoring Confirm auxiliary contacts and control interfaces
Auxiliary contacts Provide switching-position signals Check contact configuration and electrical ratings
Electrical interlocking system Prevents unsafe switching sequences Verify mechanical and electrical interlock compatibility
Grounding system Provides an appropriate protective-earth path Follow applicable electrical installation standards

The listed components are examples of equipment that may be required in a complete installation. They are not necessarily supplied with the NW10HA.

Alternative Models and Replacement Considerations

The MasterPact NW family includes several frame ratings and performance levels. A replacement must be selected according to the actual application rather than the model name alone.

Alternative Model or Family General Consideration
MasterPact NW08HA 800 A frame rating; lower current rating than NW10HA
MasterPact NW10NA 1000 A frame rating with a different performance level
MasterPact NW10HA10 Related 1000 A HA performance configuration for a different voltage application
MasterPact NW12HA 1250 A frame rating; requires application-specific verification
MasterPact NW16HA 1600 A frame rating for higher-current applications
Newer MasterPact MTZ family May be considered for a modernization project, subject to system and installation review

Before replacing the NW10HA, verify:

  • Rated operational current.
  • Rated operational voltage and frequency.
  • Number of poles.
  • Switch-disconnector versus automatic circuit-breaker classification.
  • Short-circuit making and short-time withstand ratings.
  • Fixed or drawout mounting arrangement.
  • Chassis and connection compatibility.
  • Auxiliary contacts and interlocking accessories.
  • Cabinet dimensions and busbar connections.
  • Coordination with upstream and downstream protective devices.

A circuit breaker with a similar current rating is not automatically a direct replacement for a non-automatic switch disconnector. The protection architecture and operating functions must be reviewed before making a substitution.

Key Advantages

High-Current Switching Capability

The 1000 A rating makes the NW10HA suitable for appropriately designed high-current low-voltage distribution systems.

Three-Pole Configuration

Its three-pole arrangement supports switching of compatible three-phase AC circuits.

Isolation Function

The device provides a defined switching and isolation point for maintenance and operational procedures.

MasterPact NW Platform

The product belongs to the established MasterPact NW family, which is used in industrial and commercial power distribution installations.

Fixed and Drawout Options

Depending on the selected configuration, the platform supports different installation arrangements to meet switchboard design requirements.

High Short-Time Withstand Capability

Its specified short-time withstand rating supports applications where the device must withstand defined short-circuit stresses in coordination with separate protective equipment.

Integration into Large Distribution Systems

The NW10HA can be incorporated into main distribution boards, transformer feeders, generator distribution systems, and other appropriately engineered electrical assemblies.

Technical FAQs

1. What is the Schneider Electric NW10HA?

The NW10HA is a MasterPact NW 1000 A, three-pole switch disconnector designed for low-voltage AC power distribution and circuit isolation.

2. Is the NW10HA an automatic circuit breaker?

No. The NW10HA is classified as a non-automatic switch disconnector. It does not provide the same automatic overload and short-circuit tripping functions as a circuit breaker equipped with an overcurrent trip unit.

3. What is the rated current of the NW10HA?

Its rated operational current is 1000 A.

4. How many poles does the NW10HA have?

The model is a three-pole device designed for compatible three-phase AC distribution systems.

5. What is its rated operating voltage?

The published product specification gives a rated operational voltage of up to 690 V AC at 50/60 Hz.

6. Does the NW10HA provide short-circuit protection?

It has specified short-circuit making and short-time withstand capabilities, but it is not an automatic overcurrent-protection device. A suitable protective arrangement must be provided separately.

7. Is the NW10HA available in fixed and drawout versions?

The MasterPact NW platform supports both fixed and drawout arrangements. The exact mounting type should be confirmed from the complete product configuration.

8. What is the difference between the supplied 90 kg weight and the manufacturer’s listed weight?

The supplied listing specifies 90 kg, while Schneider Electric’s product page for the corresponding NW10HA switch-disconnector configuration lists approximately 60 kg net weight. The difference may reflect packaging, additional accessories, or a different configuration. Confirm the actual unit and weighing basis before shipping.

9. Can the NW10HA replace a 1000 A circuit breaker?

Not necessarily. The NW10HA is a non-automatic switch disconnector, whereas a circuit breaker may provide automatic overload and short-circuit protection. The complete protection and switching design must be evaluated before replacement.

10. What should be checked before purchasing an NW10HA?

Confirm the model, rated current, voltage, pole configuration, mounting arrangement, electrical ratings, accessories, physical condition, and compatibility with the existing switchboard. Also verify whether the supplied unit is a complete assembly or requires a separate chassis or accessories.

Procurement and Maintenance Recommendations

When sourcing the Schneider Electric NW10HA, confirm that the required product is a switch disconnector rather than an automatic circuit breaker. This distinction is essential because the two devices have different protection functions.

Check the complete product identification and verify the rated current, voltage, number of poles, mounting arrangement, and short-circuit withstand ratings. For drawout installations, confirm the chassis and accessory requirements before ordering.

For used or surplus equipment, request clear photographs of the nameplate, terminals, operating mechanism, and connection surfaces. Check for signs of overheating, corrosion, mechanical damage, or abnormal contact wear. Where the device is intended for a critical distribution system, obtain suitable inspection and functional test records.

During maintenance, follow the manufacturer’s instructions and the site’s approved electrical safety procedures. Inspect the contact system, operating mechanism, auxiliary contacts, connection points, and interlocking arrangements at the specified intervals.

Because the NW10HA is a non-automatic switch disconnector, also verify that the associated overcurrent protection remains correctly coordinated with the electrical system. Any replacement or modification should be reviewed by qualified electrical engineers.

Conclusion

The Schneider Electric NW10HA MasterPact is a 1000 A, three-pole switch disconnector designed for high-current AC power distribution systems. With a rated operational voltage of up to 690 V AC, it provides switching and isolation functions for industrial switchboards, transformer feeders, generator distribution systems, and other large electrical installations.

Its classification as a non-automatic switch disconnector is an important selection consideration. It should be used with a suitable coordinated protection arrangement rather than treated as an automatic circuit breaker. Correct verification of mounting configuration, electrical ratings, accessories, and system compatibility helps ensure reliable integration into industrial power distribution equipment.