The Schneider NS800H ComPact Circuit Breaker is a high-capacity low-voltage circuit protection device designed for industrial and commercial power distribution systems. Belonging to Schneider Electric’s ComPact NS family, the NS800H series is intended for installations where dependable circuit protection, controlled power distribution, and the ability to interrupt substantial fault currents are essential.
Circuit breakers protect electrical systems by detecting abnormal current conditions and interrupting the circuit when the current exceeds the permitted operating limits. In industrial distribution networks, this protection helps reduce the risk of damage to cables, busbars, transformers, motors, and downstream electrical equipment.
The NS800H is an 800 A class circuit breaker. Depending on its specific configuration, it can be equipped with an electronic trip unit and arranged as a fixed or withdrawable device. Different versions are available with different pole arrangements, operating mechanisms, and protection functions. Therefore, the complete product reference and nameplate information should always be checked before selecting a replacement.
Certain NS800H configurations provide a high short-circuit breaking capacity. For example, a documented 415 V AC configuration has a rated ultimate short-circuit breaking capacity of 70 kA. This makes the series suitable for appropriately engineered distribution systems where high fault-current interruption capability is required.
The NS800H can be used in main distribution boards, industrial switchboards, power control rooms, and other low-voltage electrical installations. Its suitability depends on the system voltage, prospective short-circuit current, protection coordination requirements, and the exact breaker configuration.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Series | ComPact NS |
| Model | NS800H |
| Product Type | Low-Voltage Circuit Breaker |
| Device Application | Power Distribution |
| Rated Current Class | 800 A |
| Rated Operational Voltage | Up to 690 V AC, depending on configuration |
| Network Frequency | 50/60 Hz |
| Short-Circuit Breaking Capacity | Up to 70 kA at 415 V AC for specified H-performance configurations |
| Number of Poles | 3P or 4P, depending on configuration |
| Trip Unit | Electronic trip unit, depending on version |
| Protection Functions | Depends on installed trip unit |
| Mounting Type | Fixed or withdrawable, depending on version |
| Operating Mechanism | Manual or electrical, depending on configuration |
| Rated Insulation Voltage | Configuration-dependent |
| Rated Impulse Withstand Voltage | Configuration-dependent |
| Dimensions Provided | 224 × 210 × 182 mm |
| Weight Provided | 14 kg |
| Typical Application | Industrial and commercial low-voltage distribution |
Important: NS800H identifies a product family rather than one complete catalog configuration. The supplied dimensions and weight correspond to a particular basic-frame configuration. Verify the exact reference, trip unit, pole arrangement, mounting method, and operating mechanism before ordering.
The primary function of the NS800H is to protect electrical distribution circuits against abnormal current conditions. It provides a means of switching and isolating circuits while helping limit the consequences of electrical faults.
An overload occurs when a circuit carries more current than its intended operating level for a sustained period. This may result from excessive connected loads, equipment malfunction, or an incorrectly designed distribution system.
When equipped with a suitable protection unit, the NS800H can detect overload conditions and initiate a trip according to its configured protection settings.
Electronic trip units may provide adjustable long-time current and delay settings. These allow protection engineers to coordinate the breaker with downstream protective devices and the thermal characteristics of the protected conductors.
A short circuit can produce an extremely high current within a very short period. If it is not interrupted quickly, the resulting thermal and electromagnetic forces may damage electrical equipment.
The NS800H H-performance series includes configurations designed for high short-circuit interruption capability. Certain documented versions provide a 70 kA ultimate breaking capacity at 415 V AC.
The actual breaking capacity must be checked against the selected voltage and exact product reference. A breaker must not be applied to a circuit whose prospective fault current exceeds its rated interruption capability.
Some NS800H configurations use an electronic trip unit, such as the MicroLogic family. The trip unit monitors electrical current and evaluates it against the selected protection settings.
Depending on the installed trip unit, available functions may include long-time and instantaneous protection, with additional protection or measurement capabilities on other versions.
The trip unit configuration is important because not every NS800H breaker includes the same protection functions. A basic frame supplied without a trip unit must be equipped with a compatible control and protection unit before it can perform the intended protective function.
The NS800H can be used to connect or disconnect a distribution circuit. Depending on the version, it may use a manual operating mechanism or an electrically operated mechanism.
Suitable isolation arrangements allow maintenance personnel to work on downstream equipment under an approved electrical safety procedure.
A circuit breaker’s switching and isolation suitability must be confirmed from its exact product documentation. Operating the breaker does not replace lockout, verification of absence of voltage, or other required safety procedures.
When equipped with an appropriate electronic trip unit and auxiliary accessories, the breaker can provide information about its operating state and trip condition.
This information can support maintenance and power-distribution monitoring. The availability of measurement, alarm, and communication functions depends on the selected trip unit and installed accessories.
The NS800H is designed for high-current distribution applications. It can be installed in a switchboard or distribution assembly to protect a feeder, incoming supply, or other appropriately rated circuit.
In a main distribution board, the breaker can protect a high-capacity incoming or outgoing circuit. Its rated current class and breaking capability make it relevant to installations where substantial electrical loads are supplied through a centralized distribution system.
The breaker must be coordinated with the upstream supply, busbar system, cables, and downstream protective devices.
Industrial plants commonly distribute power through multiple feeder circuits. Each feeder supplies a group of machines, production areas, or secondary distribution boards.
An appropriately configured NS800H can protect a feeder while helping isolate a faulted section from the rest of the installation.
The NS800H may be considered for suitable transformer or generator distribution arrangements. However, selection requires detailed assessment of transformer impedance, generator characteristics, available fault current, voltage, and protection coordination.
The 800 A rating alone is not sufficient to establish suitability for a transformer or generator application.
The breaker can form part of a low-voltage switchboard assembly. Integration requires compatibility with the switchboard structure, mounting arrangement, busbar connections, terminal accessories, and electrical clearances.
Fixed and withdrawable versions have different installation requirements and should not be treated as mechanically interchangeable.
Manufacturing plants rely on electrical distribution systems to supply production machinery, control panels, compressors, pumps, and auxiliary equipment.
An appropriately rated NS800H can protect a high-current feeder or distribution section. Its selection should consider the plant’s load profile, fault level, and coordination requirements.
Power distribution boards divide electrical power among different areas of a facility. The NS800H may be used in suitable high-current distribution assemblies where an 800 A class breaker is required.
The selected breaker must match the board’s busbar design, rated current, and short-circuit withstand capability.
Infrastructure installations may include pumping stations, water-treatment plants, transportation facilities, and other large electrical systems.
In these environments, circuit protection is important for maintaining electrical system integrity and supporting controlled maintenance operations.
Large commercial buildings require distribution equipment capable of supplying lighting, HVAC, elevators, and other substantial electrical loads.
An NS800H configuration may be used in an appropriately designed low-voltage distribution system. Its suitability must be assessed against the installation’s voltage, load, fault current, and applicable electrical standards.
Process plants often operate pumps, fans, compressors, heaters, and large auxiliary systems. A high-capacity circuit breaker can help protect distribution feeders supplying these loads.
Protection settings should be coordinated with motor starters, variable frequency drives, downstream breakers, and other protective devices.
Correct installation is essential for the safe and reliable operation of a high-current circuit breaker.
Before installation, identify the exact Schneider product reference. Confirm whether the supplied unit is a complete circuit breaker or a basic frame requiring a separate trip unit.
Check the pole configuration, rated current, voltage, short-circuit performance, mounting type, operating mechanism, and installed accessories.
Confirm that the breaker is suitable for the system’s nominal voltage and frequency. Calculate or obtain the prospective short-circuit current at the installation point.
The selected breaker must have adequate interruption capacity for the actual system fault level. Protection settings must also be coordinated with the protected cables and downstream devices.
The supplied dimensions are 224 × 210 × 182 mm, with a listed weight of 14 kg.
These values should be treated as the supplied product-listing parameters for the relevant basic-frame configuration. Schneider documentation for other complete NS800H versions shows different dimensions.
Before panel design, verify the exact manufacturer’s mechanical drawing. Provide sufficient clearance for connections, operating access, heat dissipation, and maintenance.
High-current connections require correctly rated conductors, busbars, terminals, and connection hardware.
Contact surfaces must be clean and correctly assembled. Tightening torque must follow the manufacturer’s installation instructions. Incorrect connection practices can lead to excessive contact resistance and overheating.
If the breaker includes an electronic trip unit, protection settings must be selected according to the installation’s protection study.
Relevant parameters may include long-time pickup, long-time delay, and instantaneous pickup. The exact settings available depend on the installed trip unit.
Settings should be reviewed by qualified electrical personnel to ensure coordination with upstream and downstream protective devices.
Before energizing the system, inspect the breaker, mounting arrangement, terminals, busbar connections, grounding arrangements, and accessories.
Verify the mechanical operating mechanism and trip-unit installation where applicable. Carry out the electrical tests and commissioning procedures required by the manufacturer’s documentation and local regulations.
For critical installations, commissioning should be performed by qualified personnel using approved test equipment.
The NS800H is normally integrated into a larger low-voltage power distribution assembly.
| Component | Function | Compatibility Considerations |
|---|---|---|
| MicroLogic trip unit | Provides electronic protection and, on selected versions, measurement functions | Must match the breaker frame and exact configuration |
| Auxiliary contacts | Provide breaker status signals | Verify contact arrangement and accessory compatibility |
| Shunt trip | Allows remote electrical tripping | Confirm coil voltage and compatible accessory reference |
| Undervoltage release | Trips or prevents closing under specified voltage conditions | Check control voltage and operating requirements |
| Motor mechanism | Enables electrical opening and closing | Must match the breaker version |
| Busbar system | Distributes high-current power | Verify current rating, connection geometry, and short-circuit withstand |
| Distribution panel | Provides mounting and enclosure | Check mechanical dimensions, clearances, and mounting arrangement |
| Upstream protective device | Provides coordinated protection | Perform a protection coordination assessment |
| Downstream circuit breakers | Protect individual feeder circuits | Confirm selectivity and discrimination requirements |
Not all components are included with every NS800H unit. Confirm the exact accessories and trip-unit configuration before purchasing.
When replacing an NS800H, the replacement should be selected according to the electrical and mechanical requirements of the installation rather than the model name alone.
| Alternative Product Family | Replacement Considerations |
|---|---|
| Schneider ComPact NS800H equivalent configuration | Preferred starting point for like-for-like replacement when the complete reference and accessories match |
| Schneider ComPact NS630bH | Lower current class; only suitable where the system load and protection design permit |
| Schneider ComPact NS1000H | Higher current class; requires verification of cable, busbar, and coordination requirements |
| Schneider ComPact NS630b/NS1600 family | Related circuit breaker family, but ratings and mechanical compatibility must be checked |
| Schneider ComPacT NS new-generation products | May provide a modernization path, but mechanical and electrical interchangeability must be confirmed |
Before selecting a replacement, compare:
A breaker with the same 800 A rating is not necessarily a direct replacement. Its fault interruption performance, trip unit, accessories, and mechanical structure may differ.
The NS800H series is designed for high-current low-voltage distribution applications, with an 800 A rated current class.
Selected H-performance configurations provide a 70 kA ultimate short-circuit breaking capacity at 415 V AC, supporting applications with substantial prospective fault currents.
Versions equipped with MicroLogic electronic trip units can provide configurable protection functions suited to different distribution requirements.
The series includes different pole arrangements, mounting styles, and operating mechanisms. This allows the breaker to be selected for different switchboard designs.
The NS800H is designed for use in industrial and commercial electrical distribution systems where reliable circuit protection and controlled isolation are required.
Compatible auxiliary and control accessories can support remote operation, status indication, and integration into a larger electrical control arrangement.
The NS800H is a ComPact NS low-voltage circuit breaker series from Schneider Electric. It is designed for high-current power distribution and circuit protection applications.
The NS800H is an 800 A rated-current class. The actual trip rating and adjustment range depend on the installed protection unit and exact product configuration.
Certain H-performance versions provide a 70 kA ultimate breaking capacity at 415 V AC. The applicable value varies with rated operational voltage and exact catalog configuration.
Yes. The ComPact NS800H family includes both three-pole and four-pole configurations. The exact pole arrangement must be confirmed from the product reference.
No. Some product references identify a complete circuit breaker with an installed trip unit, while other references identify a basic frame without a trip unit. Check the complete catalog number and supplied hardware.
It can be used in a suitable main distribution or feeder protection position when its voltage, current, interruption capacity, and protection settings match the electrical system design.
A fixed breaker is installed directly in its mounting position. A withdrawable version uses a compatible chassis arrangement that allows the breaker to be moved between defined positions. The two configurations have different mechanical and installation requirements.
The supplied listing dimensions are 224 × 210 × 182 mm. However, other NS800H configurations have different published dimensions. Always use the mechanical drawing for the exact product reference.
Not automatically. The replacement must match the system voltage, short-circuit rating, pole configuration, trip-unit functions, mounting arrangement, and connection requirements.
Verify the complete product reference, rated current, pole arrangement, trip unit, operating mechanism, terminal condition, accessories, and mechanical condition. Request clear photographs and appropriate inspection or testing information, especially for critical power distribution applications.
When sourcing a Schneider NS800H circuit breaker, begin by identifying the complete product reference. The NS800H designation alone does not establish the full electrical or mechanical configuration.
For replacement projects, compare the nameplate information with the installed breaker and confirm the trip-unit type, rated current, pole arrangement, mounting method, operating mechanism, and accessory requirements.
For used or surplus units, inspect the main contacts where accessible under approved procedures, operating mechanism, terminals, insulation condition, and installed accessories. Ask the supplier to clarify whether the item is a complete breaker or a basic frame supplied without a trip unit.
Maintenance should follow the manufacturer’s instructions and the facility’s electrical maintenance program. Periodic inspection may include checking connection tightness, signs of overheating, mechanical operation, trip-unit condition, and auxiliary circuit operation.
Protection settings should be documented and reviewed after any modification to the distribution network. Any replacement or adjustment should be carried out by qualified electrical personnel under the applicable safety procedures.
The Schneider NS800H ComPact Circuit Breaker is an 800 A class low-voltage protection device designed for industrial and commercial power distribution systems. Selected H-performance configurations provide high short-circuit interruption capability, while different trip-unit, pole, mounting, and operating arrangements allow the series to serve a range of distribution applications.
For maintenance and procurement, the complete product reference is essential. Confirm whether the supplied unit is a basic frame or a complete circuit breaker, verify its trip-unit configuration, and check the electrical and mechanical requirements before installation.