The Schneider Electric NW08H1 MasterPact NW Air Circuit Breaker is a low-voltage power distribution protection device designed for industrial electrical systems, commercial facilities, and large-scale power distribution installations. It belongs to the MasterPact NW circuit breaker family, which is designed for applications requiring high-current switching, short-circuit protection, and reliable electrical isolation.
The NW08H1 is an 800 A frame circuit breaker with an H1 performance rating. Its rated ultimate short-circuit breaking capacity is 65 kA at 440 V AC, making it suitable for appropriately engineered distribution systems where high fault-current interruption capability is required.
Air circuit breakers are commonly installed in main distribution boards, switchgear assemblies, generator distribution systems, and industrial power control centers. They help protect electrical installations by interrupting current under specified abnormal conditions and provide switching functions for the controlled connection and disconnection of electrical circuits.
The MasterPact NW08H1 is available in different configurations. Depending on the complete product reference, the breaker may be supplied as a three-pole or four-pole unit, with fixed or drawout mounting. Some basic-frame versions are supplied without a trip unit or electronic control unit. These differences directly affect the protection functions, installation requirements, and accessories needed for operation.
For this reason, NW08H1 should be treated as the main model designation rather than a complete configuration identifier. Before purchasing or replacing the circuit breaker, verify the full catalog number, pole arrangement, mounting type, trip unit, sensor rating, and accessory configuration.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Series | MasterPact NW |
| Model | NW08H1 |
| Product Type | Air Circuit Breaker |
| Device Application | Power Distribution Protection |
| Frame Current Rating | 800 A |
| Performance Class | H1 |
| Rated Operational Voltage | Up to 690 V AC |
| Rated Frequency | 50/60 Hz |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 65 kA at 440 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 65 kA at 440 V AC |
| Rated Short-Time Withstand Current (Icw) | 65 kA for 1 second, configuration-dependent |
| Rated Insulation Voltage (Ui) | 1000 V AC |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Pole Configuration | 3P or 4P, depending on complete reference |
| Mounting Type | Fixed or drawout, depending on configuration |
| Trip Unit | Depends on the complete product reference |
| Dimensions Provided | 352 × 422 × 297 mm |
| Weight Provided | 50 kg |
| Typical Application | Industrial low-voltage power distribution |
Important: The NW08H1 designation alone does not identify every mechanical and protection option. The dimensions and weight above are the supplied listing values. Confirm them against the complete catalog number and physical product before installation or shipment.
The NW08H1 is designed to perform switching and circuit protection functions in low-voltage power distribution systems. Its operating mechanism and interruption system allow it to connect or disconnect electrical circuits and interrupt current when the installed protection arrangement detects a qualifying fault.
Electrical distribution circuits may experience overloads when connected equipment draws more current than the system is designed to carry. If an overload continues, cables, busbars, and electrical equipment can overheat.
When fitted with a compatible trip unit, the circuit breaker can monitor current and initiate a trip when configured protection thresholds and timing conditions are reached.
The exact protection functions depend on the installed trip unit. A basic frame supplied without a trip unit does not independently provide the complete electronic protection functions expected from a fully configured circuit breaker.
A short circuit can produce extremely high fault current within a very short period. The circuit breaker must interrupt the fault safely within its rated operating limits.
The NW08H1 H1 performance class provides a published 65 kA ultimate breaking capacity at 440 V AC. This rating indicates the maximum short-circuit current the breaker is designed to interrupt under the specified test conditions.
The actual application must be checked against the prospective short-circuit current at the installation point. The breaker must not be selected solely because its frame current matches the load.
The MasterPact NW08H1 can be used for switching functions in industrial distribution systems. Depending on its configuration, the breaker may support manual operation and additional electrical operating accessories.
In a typical installation, the breaker is positioned between the incoming power supply and a downstream distribution section. It allows authorized personnel or a coordinated control system to manage the connection of the protected circuit.
Switching arrangements must follow the manufacturer’s instructions and the electrical system’s operating procedures.
The MasterPact NW family is designed for applications requiring circuit isolation in accordance with applicable standards. This function is important when maintenance personnel need to isolate a distribution section before inspection or repair.
Isolation procedures must still include the required verification of absence of voltage, lockout measures, and other site-specific safety controls. Operating a circuit breaker does not replace a complete electrical safety procedure.
The circuit breaker should be coordinated with upstream and downstream protective devices. Proper coordination helps ensure that a fault is cleared by the appropriate device while minimizing unnecessary interruption to unaffected parts of the electrical installation.
Protection settings, breaker ratings, cable capacity, fault levels, and system selectivity requirements should be reviewed by qualified electrical engineers.
The NW08H1 is generally used in the main or intermediate stages of low-voltage power distribution. Its 800 A frame rating and H1 interruption performance make it relevant to installations where substantial electrical loads must be switched and protected.
In a main distribution board, the circuit breaker can serve as an incoming or outgoing protection device, depending on the system design. It separates electrical sections and supports controlled distribution of power to downstream equipment.
The NW08H1 can be incorporated into low-voltage switchgear assemblies. The exact installation depends on whether the selected version is fixed-mounted or drawout.
A drawout version can be withdrawn from its connected position for inspection or maintenance according to the equipment’s approved procedures. A fixed version is mounted directly within the switchgear assembly and requires a different maintenance approach.
Industrial generator systems require correctly rated switching and protection equipment. A MasterPact NW breaker may be used in generator distribution arrangements when its voltage, current, short-circuit performance, and protection configuration are suitable.
Generator applications require careful consideration of fault-current characteristics, grounding, synchronization, and protective coordination.
Large industrial facilities often distribute power to motor control centers, pumps, compressors, production lines, and other process equipment. The NW08H1 may serve as an upstream distribution protection device supplying these sections.
It should not be confused with a motor starter or motor overload relay. Its role is at the power distribution level, while downstream motor-control equipment provides application-specific motor switching and protection.
Manufacturing plants use low-voltage distribution systems to supply production machinery, automated lines, auxiliary equipment, and facility services.
The NW08H1 can be used in suitable distribution assemblies to protect and switch a high-current feeder. Its application must be evaluated against the facility’s load profile and prospective fault current.
Large commercial buildings and industrial complexes require reliable distribution of electrical power to lighting systems, HVAC equipment, elevators, pumps, and other building services.
A properly configured MasterPact NW08H1 can serve as part of the main or secondary distribution arrangement.
Electrical distribution rooms contain switchboards, busbar systems, feeder circuits, and protective devices. The NW08H1 can be installed in compatible low-voltage switchgear where its current and breaking ratings meet the design requirements.
Backup generators and standby power installations require switching and protection devices suitable for their electrical characteristics. The NW08H1 may be considered for generator output or distribution feeders when the complete protection arrangement is properly engineered.
Water treatment plants, transportation facilities, industrial utilities, and other infrastructure installations depend on stable power distribution. Air circuit breakers can help protect major distribution sections and support maintenance isolation.
The specific suitability of the NW08H1 depends on the electrical design, environmental conditions, and applicable installation standards.
Correct installation is essential for safe operation and reliable circuit protection.
Before installation, confirm the complete catalog number and identify the breaker configuration.
Check the following:
The NW08H1 model designation by itself does not confirm all these details.
Verify the system’s operating voltage, frequency, rated current, and prospective short-circuit current.
The 800 A frame rating should not be interpreted as the only current value relevant to protection. Sensor ratings and trip-unit settings may determine the actual protection characteristics.
The selected breaker must be suitable for the installation’s fault level and coordinated with the upstream and downstream protective devices.
The supplied dimensions are 352 × 422 × 297 mm, with a listed weight of 50 kg.
Before designing the switchgear compartment, verify the exact mechanical drawing for the selected fixed or drawout version. Pole configuration and accessory arrangements can affect the required space.
The switchgear structure must support the breaker’s weight and withstand the mechanical forces associated with normal operation and fault conditions.
Busbar and cable connections must be suitable for the rated current and installation conditions. Follow the manufacturer’s instructions for conductor sizing, connection surfaces, tightening torque, and phase arrangement.
Poor connections can create excessive contact resistance, local heating, and long-term equipment damage.
If the selected breaker includes an electronic trip unit, protection settings must be configured according to the electrical system study.
Typical considerations include:
Do not assume that every NW08H1 basic frame includes these functions. Confirm the actual trip unit and its supported protection features.
Before energizing the system, qualified personnel should inspect the mechanical installation, power connections, grounding, control wiring, and accessory configuration.
Commissioning should include appropriate mechanical and electrical checks, verification of trip-unit settings, and functional testing according to the manufacturer’s procedures.
All testing should be performed by qualified personnel using approved equipment and site safety procedures.
The NW08H1 normally operates as part of a wider low-voltage distribution assembly. The components below are examples of equipment that may be required, depending on the selected configuration.
| Component | Function | Integration Considerations |
|---|---|---|
| Electronic trip unit | Provides configurable overcurrent protection | Verify compatibility with the exact breaker frame |
| Current sensors | Measure current for protection functions | Confirm sensor rating and trip-unit compatibility |
| Drawout chassis | Supports drawout breaker installation | Required only for compatible drawout configurations |
| Auxiliary contacts | Provide breaker status signals | Confirm contact arrangement and electrical ratings |
| Shunt trip release | Enables remote electrical tripping | Verify coil voltage and accessory compatibility |
| Undervoltage release | Trips or prevents closing under specified voltage conditions | Confirm control supply and operating characteristics |
| Closing release | Supports electrical closing operation | Check accessory and control-circuit requirements |
| Motor mechanism | Supports remote charging or operation where configured | Confirm the correct mechanism and supply voltage |
| Busbar system | Distributes current to connected circuits | Verify current capacity, spacing, and connection design |
| Switchgear enclosure | Provides mechanical support and protection | Match the enclosure to breaker dimensions and mounting type |
These components are not necessarily included with the basic breaker frame. Their availability and compatibility must be checked against the full catalog number.
The MasterPact NW family includes different frame sizes and performance classes. Other models may be considered during replacement planning, but they are not automatically interchangeable.
| Related Model | General Description | Replacement Considerations |
|---|---|---|
| NW08N1 | 800 A frame, N1 performance class | Lower interrupting performance than NW08H1; verify fault level |
| NW08H2 | 800 A frame, higher H2 performance class | Higher interrupting capability; verify dimensions and configuration |
| NW08H3 | 800 A frame, H3 performance class | Requires complete rating and mounting comparison |
| NW10H1 | 1000 A frame, H1 performance class | Different frame current rating and potentially different dimensions |
| NW12H1 | 1250 A frame, H1 performance class | Higher frame rating; not a direct substitute without engineering review |
Before selecting a replacement, compare:
A replacement should be approved only after a qualified engineer confirms that it meets the installation’s electrical and mechanical requirements.
The 800 A frame rating makes the NW08H1 suitable for appropriately designed high-current low-voltage distribution applications.
Its 65 kA ultimate breaking capacity at 440 V AC provides a defined interruption capability for installations with high prospective fault currents.
The MasterPact NW08H1 designation is associated with different pole and mounting configurations, allowing selection according to the requirements of the switchgear assembly.
The breaker is designed for use in industrial and commercial distribution systems where high-current switching and protection are required.
Compatible configurations are suitable for isolation in accordance with applicable standards, supporting planned electrical maintenance procedures.
Depending on the complete configuration, compatible trip units, auxiliary contacts, and electrical operating accessories can support broader protection and control strategies.
The NW08H1 is a MasterPact NW low-voltage air circuit breaker with an 800 A frame rating and H1 short-circuit performance. It is designed for power distribution protection in industrial and commercial electrical systems.
The frame current rating is 800 A at the specified reference temperature of 40 °C. The actual protection rating depends on the sensor and trip-unit configuration.
The H1 version has a rated ultimate short-circuit breaking capacity of 65 kA at 440 V AC. The applicable rating must be checked at the actual system voltage.
The published rated operational voltage is up to 690 V AC at 50/60 Hz. Confirm the exact rating and applicable breaking capacity for the installation voltage.
Yes. The MasterPact NW08H1 family includes both three-pole and four-pole configurations, depending on the complete product reference.
Both mounting arrangements are available within the product family. The complete catalog number is required to identify the mounting type of a particular unit.
Not necessarily. Some basic-frame versions are supplied without a trip unit or control unit. Verify the complete product reference and inspect the installed hardware before purchasing.
It may be used as a main or feeder breaker when its current rating, voltage rating, breaking capacity, protection configuration, and switchgear arrangement meet the electrical system design.
Check the complete catalog number, pole arrangement, mounting type, trip unit, sensor rating, electrical accessories, terminal layout, and switchgear dimensions. Also verify that the replacement has adequate short-circuit performance for the installation.
Maintenance should follow the manufacturer’s instructions and the facility’s electrical maintenance program. Typical activities include inspecting the contacts and connections, checking mechanical operation, reviewing trip-unit settings, and performing approved functional tests. Work must be carried out by qualified personnel under appropriate electrical safety procedures.
When purchasing a Schneider Electric NW08H1, identify the complete product reference rather than relying only on the model designation. The NW08H1 family includes different pole configurations, mounting arrangements, and trip-unit options.
For replacement projects, compare the nameplate and mechanical configuration of the existing breaker with the proposed unit. Confirm whether the product is supplied with a trip unit, current sensors, auxiliary contacts, operating releases, and other accessories required by the switchgear.
For new-old-stock or used equipment, request clear photographs of the nameplate, front panel, terminals, and operating mechanism. Confirm the physical condition, storage history, test status, and warranty or return terms.
During maintenance, inspect the breaker and its switchgear compartment according to the manufacturer’s recommended procedures. Pay particular attention to connection condition, contact wear, mechanical operation, accessory wiring, and trip-unit configuration.
Because this is a high-current protection device, selection and commissioning should be performed by qualified electrical professionals. A breaker that fits mechanically may still be unsuitable if its breaking capacity, protection settings, or electrical accessories do not match the installation.
The Schneider Electric NW08H1 MasterPact NW is an 800 A low-voltage air circuit breaker designed for industrial and commercial power distribution systems. Its H1 performance class provides a rated ultimate short-circuit breaking capacity of 65 kA at 440 V AC, while its product family supports different pole and mounting configurations.
For maintenance, replacement, and procurement applications, the complete catalog number is essential. Confirming the pole arrangement, fixed or drawout construction, trip unit, sensor rating, and accessory configuration helps ensure that the selected NW08H1 matches the electrical and mechanical requirements of the installation.