The Honeywell 2108B0272 Searchpoint Optima Plus Calibration Cap is a dedicated calibration accessory for the Searchpoint Optima Plus infrared point gas detector. It is used to establish a controlled gas application arrangement during detector calibration, helping technicians introduce calibration gas to the detector’s measurement chamber under the conditions required for an accurate calibration procedure.
Unlike the Gassing Cover, which is intended for applying gas during functional checks in the field, the Calibration Cap is specifically intended for calibration. The distinction matters during maintenance because a functional gas test and an instrument calibration are not the same operation. Each requires the appropriate accessory and installation arrangement.
The 2108B0272 is particularly useful in industrial facilities where fixed hydrocarbon or ethylene gas detection equipment must undergo scheduled calibration. Typical installations include oil and gas processing facilities, chemical plants, offshore platforms, and industrial compressor stations. In these environments, gas detectors are installed at locations where a release could create a fire or explosion hazard. Periodic calibration helps maintain the accuracy of the detector’s measurement response.
During calibration, the cap is fitted to the Searchpoint Optima Plus detector to establish the gas inlet and outlet arrangement. Calibration gas is introduced through the designated inlet, passes through the measurement area, and exits through the outlet. This controlled gas application allows the technician to carry out the calibration procedure without relying on uncontrolled ambient gas conditions.
An important installation requirement is that the detector’s weather protection must be removed before fitting the Calibration Cap, except for the dust barrier. Leaving other protective accessories in place can interfere with the intended calibration arrangement.
The 2108B0272 is a temporary maintenance accessory rather than a permanent part of the detector installation. Once calibration is complete, it must be removed so that ambient gas can reach the detector’s measurement chamber normally. Leaving the cap installed would obstruct the normal gas exposure path and compromise the detector’s ability to monitor its surroundings.
For maintenance teams responsible for Searchpoint Optima Plus installations, the 2108B0272 provides a dedicated accessory for carrying out controlled calibration work while keeping calibration procedures separate from routine functional testing.
| Parameter | Specification |
|---|---|
| Manufacturer | Honeywell |
| Brand | Honeywell Analytics |
| Model | 2108B0272 |
| Product Type | Searchpoint Optima Plus Calibration Cap |
| Product Family | Searchpoint Optima Plus |
| Component Category | Gas Detector Calibration Accessory |
| Compatible Detector | Searchpoint Optima Plus |
| Primary Function | Controlled Gas Application During Calibration |
| Application | Detector Calibration and Maintenance |
| Gas Connection | Inlet and Outlet |
| Installation Type | Temporary Installation |
| Weather Protection Requirement | Remove All Weather Protection Except Dust Barrier |
| Compatible Detector Technology | Infrared Point Gas Detection |
| Dimensions | 190 × 40 × 80 mm |
| Weight | 0.5 kg |
The 2108B0272 operates by establishing a controlled gas application path around the measurement chamber of the Searchpoint Optima Plus detector. Its purpose is not to measure gas concentration independently, but to allow the detector to be exposed to a known calibration gas during the calibration process.
The calibration arrangement can be understood through the following sequence:
Calibration Gas Supply → 2108B0272 Inlet → Searchpoint Optima Plus Measurement Chamber → Calibration Cap Outlet
Preparing the Detector
Before calibration begins, the technician must prepare the detector according to the Searchpoint Optima Plus operating procedure.
All weather protection accessories must be removed except the dust barrier. This step is necessary because the Calibration Cap must have the correct access to the detector’s measurement chamber.
The detector’s optical surfaces and surrounding installation should also be checked for contamination or other conditions that could affect the calibration procedure.
Introducing Calibration Gas
Once the Calibration Cap is correctly fitted, calibration gas is introduced through its inlet connection.
The gas passes through the measurement area of the Searchpoint Optima Plus detector, exposing the infrared sensing system to the known gas concentration.
The outlet provides a path for the gas to leave the calibration arrangement. This helps establish the intended gas application conditions during the procedure.
Detector Response and Calibration
The Searchpoint Optima Plus uses infrared absorption technology to detect target gases. When calibration gas enters the measurement chamber, the detector responds to the infrared absorption characteristics of the gas.
The technician follows the detector’s calibration procedure and checks the measured response against the known calibration gas concentration.
The calibration process allows the detector’s measurement response to be adjusted according to the prescribed procedure. The Calibration Cap provides the gas application arrangement, while the detector’s internal sensing and signal-processing circuits perform the actual measurement.
Removing the Calibration Cap
After the calibration procedure has been completed, the 2108B0272 must be removed.
This is an essential part of the process rather than an optional maintenance step. The cap is intended for temporary use, and leaving it fitted can prevent ambient gas from reaching the measurement chamber.
Once the accessory has been removed, the detector’s normal weather protection arrangement can be restored according to the installation requirements.
Calibration Versus Functional Testing
The 2108B0272 should not be confused with the Honeywell 2108D0258 Gassing Cover.
The Calibration Cap is used for accurate calibration and requires the weather protection arrangement to be changed before installation. The Gassing Cover is used to apply gas during field functional checks and fits over the standard weather protection.
Choosing the correct accessory helps prevent confusion between verifying detector operation and performing an actual calibration.
The Honeywell 2108B0272 serves as a maintenance accessory within the Searchpoint Optima Plus fixed infrared gas detection system. It supports calibration activities without becoming part of the detector’s permanent gas monitoring configuration.
A typical maintenance arrangement follows this sequence:
Searchpoint Optima Plus Gas Detector → Remove Weather Protection Except Dust Barrier → Install 2108B0272 → Introduce Calibration Gas → Verify Detector Response → Remove Calibration Cap → Restore Normal Detector Configuration
| System Component | Function |
|---|---|
| Honeywell 2108B0272 | Establishes the gas application arrangement for detector calibration |
| Searchpoint Optima Plus | Measures target gas concentrations using infrared absorption |
| Dust Barrier 2108B0259 | Protects the detector’s optical surfaces while remaining installed during calibration |
| Standard Weather Protection 2108B0276 | Protects the detector during normal outdoor operation |
| Gassing Cover 2108D0258 | Applies gas for field functional checks |
| Calibration Gas Cylinder | Supplies gas with a known concentration for calibration |
| Gas Flow Regulator | Controls calibration gas delivery according to the prescribed procedure |
| SHC1 Handheld Interrogator | Supports detector configuration, interrogation, and maintenance |
| SHC Calibrator Connector System 2104B6250 | Provides a compatible connection for supported SHC calibration arrangements |
In an industrial gas detection installation, the Searchpoint Optima Plus normally operates continuously with its designated weather protection installed. During scheduled maintenance, the detector is temporarily prepared for calibration.
The 2108B0272 is fitted only for this maintenance operation. After calibration, removing the cap restores the detector’s access to ambient gas, allowing it to return to its normal monitoring function.
This separation between permanent detector accessories and temporary calibration equipment is important when maintaining gas detection systems in hazardous industrial environments.
| Application | Typical Use |
|---|---|
| Oil and Gas Processing | Calibration of fixed infrared hydrocarbon gas detectors in processing areas |
| Offshore Platforms | Scheduled calibration of gas detectors exposed to marine operating conditions |
| Petrochemical Plants | Maintaining the measurement accuracy of hydrocarbon detection equipment |
| Chemical Processing | Calibration of fixed gas detectors installed around process equipment |
| Natural Gas Facilities | Supporting maintenance of infrared gas monitoring installations |
| Compressor Stations | Calibration of detectors installed around gas compression equipment |
| Refinery Units | Routine calibration of fixed gas detection points in process areas |
| Industrial Storage Facilities | Maintaining gas detection equipment around hydrocarbon storage areas |
| LNG Facilities | Supporting calibration activities for compatible infrared gas detection systems |
| Hazardous Area Monitoring | Providing a dedicated accessory for detector calibration procedures |
| Component | Function |
|---|---|
| Honeywell 2108B0272 | Searchpoint Optima Plus Calibration Cap |
| Honeywell 2108D0258 | Searchpoint Optima Plus Gassing Cover for field functional checks |
| Honeywell 2108B0259 | Searchpoint Optima Plus Dust Barrier |
| Honeywell 2108B0276 | Searchpoint Optima Plus Standard Weather Protection |
| Honeywell 2108B0280 | Searchpoint Optima Plus Storm Baffle |
| Honeywell 2108D0275 | Searchpoint Optima Plus Deluge / Heat Shade |
| Honeywell 2108B0282 | Searchpoint Optima Plus Flow Housing |
| Honeywell 04230-A-1001 | SHC1 Handheld Interrogator, ATEX / IECEx Version |
| Honeywell 2104B2351 | SHC1 Handheld Interrogator, UL Version |
| Honeywell 2104B2354 | SHC1 Handheld Interrogator, CSA Version |
| Honeywell 2104B6250 | SHC Calibrator Connector System |
| Honeywell 2108M0550 | Searchpoint Optima Plus Operating Instructions |
| Model | Product Type | Typical Application |
|---|---|---|
| Honeywell 2108D0258 | Searchpoint Optima Plus Gassing Cover | Field functional gas testing |
| Honeywell 2108B0259 | Searchpoint Optima Plus Dust Barrier | Optical protection against dust and oil mist |
| Honeywell 2108B0276 | Searchpoint Optima Plus Standard Weather Protection | Normal environmental protection |
| Honeywell 2108B0280 | Searchpoint Optima Plus Storm Baffle | Protection against heavy rain and sea spray |
| Honeywell 2108D0275 | Searchpoint Optima Plus Deluge / Heat Shade | Additional protection against deluge and heat exposure |
| Honeywell 2108B0282 | Searchpoint Optima Plus Flow Housing | Gas sampling and flow-through installation arrangements |
The 2108B0272 is a Calibration Cap used for accurate calibration of the Searchpoint Optima Plus detector. The 2108D0258 is a Gassing Cover intended for field functional checking. The two accessories have different installation arrangements: the Calibration Cap requires removal of all weather protection except the dust barrier, while the Gassing Cover fits over the standard weather protection.
No. The Searchpoint Optima Plus calibration procedure specifies that all weather protection must be removed except the dust barrier. The dust barrier can therefore remain installed while the Calibration Cap is fitted.
No. The 2108B0272 is intended for temporary use during calibration. It must be removed after the procedure because leaving it fitted can prevent ambient gas from reaching the detector’s measurement chamber, interfering with normal gas detection.
No. The accessory only establishes the gas application arrangement. The Searchpoint Optima Plus detector performs the infrared gas measurement, while the technician carries out the calibration and verifies the detector response using the prescribed procedure and known calibration gas concentration.