The Honeywell AMPS-24E NOTIFIER Addressable Power Supply and Battery Charger is an intelligent power management unit used in NOTIFIER ONYX-series fire alarm systems. It combines regulated DC power distribution, standby battery charging, and addressable power supervision in one assembly. Its primary purpose is to maintain power to fire alarm system components during normal operation and provide backup power when the building’s AC supply is interrupted.
Unlike a conventional auxiliary power supply, the AMPS-24E communicates with the fire alarm control panel through the Signaling Line Circuit (SLC) or a supported system communication connection. This allows the control panel to monitor power-related conditions, including AC supply failure, battery problems, charger faults, and other trouble conditions.
The AMPS-24E is the 220–240 VAC version of the AMPS-24 family. It is particularly relevant to installations using international AC power standards. The unit supports FlashScan and CLIP communication protocols and is compatible with the NFS-3030 and NFS2-3030 Fire Alarm Control Panels. It can also serve as the primary power supply for the NCA-2 Network Control Annunciator.
A typical installation can be found in a large commercial building, hospital, industrial facility, or multi-zone fire detection system. The main fire alarm control panel may be installed in a central equipment room, while remote annunciators and other fire alarm devices are distributed throughout the building. The AMPS-24E supplies the required DC power to compatible equipment and maintains the standby battery system.
The unit has a main 24 V DC output and auxiliary power outputs, together with a dedicated sealed lead-acid battery charging circuit. Its battery charger supports selectable charging currents of 1 A, 2 A, and 5 A, accommodating battery capacities from 7 Ah to 200 Ah according to the selected configuration.
One particularly useful feature is its power supervision capability. The AMPS-24E monitors AC power availability, battery conditions, and charger operation. When an abnormal condition occurs, the unit can report the corresponding trouble information to the connected fire alarm control system. AC loss delay reporting also allows the system to manage the reporting of temporary power interruptions.
The AMPS-24E consists of two principal circuit boards: the CPS-24 board and the AMPS-K2 board. These boards handle different parts of the power supply, battery charging, and output distribution functions. Their combined operation allows the unit to support both the main fire alarm power requirements and additional auxiliary equipment.
For fire alarm installations that require supervised remote power distribution and standby battery support, the AMPS-24E provides an integrated power supply arrangement within the NOTIFIER control architecture.
| Parameter | Specification |
|---|---|
| Manufacturer | Honeywell |
| Brand | NOTIFIER |
| Model | AMPS-24E |
| Product Type | Addressable Power Supply and Battery Charger |
| Product Family | NOTIFIER AMPS-24/E |
| Module Configuration | CPS-24 and AMPS-K2 Circuit Boards |
| Primary AC Input | 220–240 VAC |
| AC Frequency | 50/60 Hz |
| Maximum AC Input Current | 2.5 A |
| Main DC Output | 24 V DC |
| Auxiliary DC Outputs | 24 V DC and 5 V DC |
| Auxiliary 24 V Output | 0.5 A Maximum |
| Auxiliary 5 V Output | 0.15 A Maximum |
| Battery Type | Sealed Lead-Acid |
| Supported Battery Capacity | 7–200 Ah |
| Selectable Charging Current | 1 A, 2 A, 5 A, or OFF |
| Nominal Battery Charging Voltage | 27.6 V DC |
| Main 24 V Output Current | Up to 5 A, depending on configuration |
| Auxiliary Output Current | Configuration-dependent |
| Communication Protocol | FlashScan / CLIP |
| Communication Interface | Signaling Line Circuit (SLC) |
| Additional Interface | EIA-485 Harness Connection |
| Battery Supervision | Yes |
| Charger Supervision | Yes |
| AC Loss Detection | Yes |
| AC Loss Delay Reporting | Yes |
| Brownout Detection | Yes |
| Deeply Discharged Battery Protection | Yes |
| Battery Low-Voltage Disconnect | 17 V |
| Trouble Reporting | Five-Point Trouble Reporting |
| Programming Interface | USB Type B |
| Installation Options | CAB-4 Series, EQ Cabinet Series, BB-25, BB-100, BB-200 |
| Dimensions | 175 × 55 × 150 mm |
| Weight | 1.93 kg |
The AMPS-24E operates as a supervised power distribution and battery charging unit within a NOTIFIER fire alarm system. It manages the conversion of incoming AC power into the DC power required by connected equipment while maintaining a standby battery supply.
Its operation can be divided into four main functions.
AC Power Conversion and DC Distribution
The AMPS-24E receives 220–240 VAC, 50/60 Hz input power through its primary AC connection. Its internal power conversion circuits generate regulated DC power for the main fire alarm system and auxiliary equipment.
The main 24 V output supplies compatible fire alarm components. Additional auxiliary outputs provide 24 V DC at up to 0.5 A and 5 V DC at up to 0.15 A.
The available current for the main and auxiliary outputs depends on the selected battery charging configuration. When a higher battery charging current is selected, the available auxiliary output capacity may need to be reduced.
For example, a building installation may use the main 24 V output to supply fire alarm control equipment while the auxiliary outputs support compatible annunciator or communication components.
Standby Battery Charging
The battery charging circuit maintains the standby power source during normal AC operation.
The AMPS-24E supports sealed lead-acid batteries with capacities ranging from 7 Ah to 200 Ah. Charging current can be selected at 1 A, 2 A, or 5 A, depending on the battery capacity and system configuration.
The nominal charging voltage is 27.6 V DC.
When the AC supply is available, the charger maintains the connected batteries at the appropriate charging condition. If the primary AC supply fails, the battery system becomes the backup energy source for the connected fire alarm equipment.
This function is particularly important in buildings where fire detection and notification equipment must remain operational during electrical outages.
Power Supervision and Trouble Reporting
The AMPS-24E continuously monitors important power supply conditions, including AC availability, battery condition, and charger operation.
If the incoming AC supply is interrupted, the unit detects the loss and can communicate the corresponding trouble condition to the fire alarm control panel. Battery and charger supervision help identify problems that could affect standby power availability.
The unit also incorporates brownout detection. This allows abnormal reductions in the incoming AC voltage to be recognized as a power-related condition.
Its isolated SLC interface supports communication with compatible fire alarm control panels using FlashScan or CLIP protocols.
In practical operation, these functions allow maintenance personnel to identify a power supply problem through the fire alarm system rather than relying exclusively on local inspection of the power supply assembly.
Battery Protection During Extended Power Failure
During an extended AC interruption, the connected sealed lead-acid batteries supply the required backup power.
If battery voltage falls to approximately 17 V, the deeply discharged battery protection function disconnects the battery supply. This prevents the battery from continuing to discharge below the specified cutoff level.
When normal AC power returns, the power supply resumes its normal operating functions and the battery charging circuit can recharge the connected batteries.
The battery protection function is especially relevant in installations where the duration of a power outage cannot be predicted.
Addressable Communication with the Fire Alarm System
The AMPS-24E can operate as an addressable device on the SLC using FlashScan or CLIP communication. It can also connect directly to supported equipment such as the CPU2-3030 or NCA-2 through an EIA-485 harness connection.
This arrangement allows the power supply to exchange status information with the fire alarm control system.
The controller can therefore receive information about power-related trouble conditions and display them through the fire alarm system interface.
The Honeywell AMPS-24E serves as an intelligent power supply and battery charger within the NOTIFIER ONYX fire alarm architecture. It supports the power requirements of compatible control equipment and remote devices while providing monitored standby battery operation.
A typical system arrangement follows this structure:
NFS2-3030 Fire Alarm Control Panel → SLC / EIA-485 Communication → AMPS-24E → Main 24 V DC Output and Auxiliary Outputs → Compatible Fire Alarm Equipment
| System Component | Function |
|---|---|
| Honeywell AMPS-24E | Provides supervised DC power distribution and battery charging |
| CPS-24 Board | Handles AC power input, auxiliary power outputs, and battery charging functions |
| AMPS-K2 Board | Handles the main 24 V DC output and associated power distribution |
| NFS-3030 | Compatible intelligent fire alarm control panel |
| NFS2-3030 | Compatible intelligent fire alarm control panel |
| NCA-2 | Network Control Annunciator that can use the AMPS-24E as its primary power supply |
| CPU2-3030 | Compatible fire alarm control unit for direct connection |
| SLC Circuit | Carries addressable communication and supervision information |
| EIA-485 Harness | Provides a direct communication connection to supported equipment |
| Sealed Lead-Acid Batteries | Supply standby power during AC interruptions |
| Remote Annunciators | Display fire alarm system conditions at remote locations |
| Auxiliary Fire Alarm Devices | Receive DC power through compatible auxiliary outputs |
In a large building, the NFS2-3030 may serve as the main fire alarm control panel, while the AMPS-24E supplies power to additional system equipment.
The power supply can be installed remotely from the main ONYX-series panel and connected to the SLC for supervision. In this configuration, it can simultaneously supply power to compatible remote equipment and charge its standby batteries.
When the incoming AC supply fails, the connected batteries maintain the required backup power. At the same time, the AMPS-24E communicates the power-related trouble condition to the fire alarm system.
This arrangement allows power distribution and supervision to be handled as part of the overall fire alarm control architecture.
| Application | Typical Use |
|---|---|
| Commercial Buildings | Supplying auxiliary DC power and standby battery support for fire alarm equipment |
| Hospitals | Maintaining power to compatible fire alarm system components during AC interruptions |
| Industrial Facilities | Supporting distributed fire detection and notification equipment |
| Shopping Centers | Powering remote fire alarm devices and annunciator equipment |
| Office Complexes | Providing supervised power distribution for multi-zone fire alarm installations |
| Transportation Facilities | Supporting fire alarm control equipment in large public facilities |
| Hotels | Maintaining backup power for compatible fire alarm system components |
| Educational Institutions | Supporting distributed fire alarm equipment across multiple buildings or zones |
| Large Warehouses | Supplying power to remote fire alarm devices and system accessories |
| Networked Fire Alarm Systems | Providing monitored auxiliary power within NOTIFIER ONYX installations |
| Component | Function |
|---|---|
| Honeywell AMPS-24E | Addressable power supply and battery charger for 220–240 VAC systems |
| Honeywell AMPS-24 | Corresponding 120 VAC version of the addressable power supply |
| Honeywell CPS-24 | Power supply and battery charger circuit board |
| Honeywell AMPS-K2 | Main power supply circuit board |
| Honeywell NFS-3030 | Intelligent fire alarm control panel |
| Honeywell NFS2-3030 | Intelligent fire alarm control panel |
| Honeywell NCA-2 | Network Control Annunciator |
| Honeywell CPU2-3030 | Fire alarm control panel CPU assembly |
| Honeywell DS-DB | Compatible system display equipment |
| Honeywell CAB-4 Series | Fire alarm equipment cabinet |
| Honeywell EQ Cabinet Series | Equipment cabinet for compatible fire alarm assemblies |
| Honeywell BB-25 | Battery backbox |
| Honeywell BB-100 | Battery backbox |
| Honeywell BB-200 | Battery backbox |
| Sealed Lead-Acid Battery | Standby power source for fire alarm equipment |
| Model | Product Type | Typical Application |
|---|---|---|
| Honeywell AMPS-24 | NOTIFIER Addressable Power Supply and Battery Charger | 120 VAC power supply installations |
| Honeywell NFS2-3030 | NOTIFIER Intelligent Fire Alarm Control Panel | Central fire detection and alarm control |
| Honeywell NFS-3030 | NOTIFIER Intelligent Fire Alarm Control Panel | Addressable fire alarm system installations |
| Honeywell NCA-2 | NOTIFIER Network Control Annunciator | Network-wide fire alarm monitoring and display |
| Honeywell CPS-24 | NOTIFIER Power Supply Circuit Board | Power distribution and battery charging circuitry |
| Honeywell AMPS-K2 | NOTIFIER Main Power Supply Circuit Board | Main 24 V DC power distribution |
The primary difference is the AC input voltage. The AMPS-24 is intended for 110–120 VAC operation, while the AMPS-24E supports 220–240 VAC at 50/60 Hz. Their power supply and battery charging functions are otherwise based on the same product family. The correct version should be selected according to the available building power supply.
The AMPS-24E supports compatible sealed lead-acid batteries with capacities ranging from 7 Ah to 200 Ah. Its charging current can be selected at 1 A, 2 A, or 5 A, depending on the battery capacity and system configuration. The selected charging setting must also be considered when calculating the available current for the main and auxiliary outputs.
Yes. The AMPS-24E can be installed remotely from a compatible ONYX-series fire alarm panel. It can communicate through the SLC using FlashScan or CLIP protocols, allowing the control panel to supervise the power supply. Supported equipment can also connect directly through an EIA-485 harness arrangement.
When incoming AC power is interrupted, the connected standby batteries supply the required backup power to the supported equipment. The AMPS-24E detects the AC failure and reports the corresponding trouble condition through the fire alarm system. If battery voltage falls to approximately 17 V, its deeply discharged battery protection disconnects the battery to prevent further excessive discharge.