The ABB PR111/P LSI SACE Emax Electronic Trip Unit is an electronic protection release used in ABB SACE Emax low-voltage air circuit breakers. It monitors current flowing through the circuit breaker and evaluates overload and short-circuit conditions to determine when the breaker must trip.
The PR111/P belongs to ABB’s self-powered electronic protection release family. It obtains its operating energy from the current transformers installed in the circuit breaker, eliminating the need for a separate auxiliary power supply for its basic protection functions.
The LSI configuration combines three protection functions: Long-time overload protection (L), Short-time short-circuit protection (S), and Instantaneous short-circuit protection (I). These functions allow the circuit breaker to respond to different levels of abnormal current according to their respective trip characteristics.
In industrial power distribution systems, electrical loads such as motors, transformers, production machinery, and distribution feeders can experience overloads or short circuits. Without appropriate protection, excessive current can damage cables, electrical equipment, and connected machinery.
The PR111/P LSI monitors the current measured by the circuit breaker’s current transformers. When the measured current exceeds the configured protection thresholds, the electronic release evaluates the corresponding protection condition and initiates a trip command.
For example, in a manufacturing facility, a motor feeder may experience an overload caused by excessive mechanical loading. The long-time protection function allows the circuit to tolerate temporary current increases while responding to sustained overload conditions. If a short circuit occurs, the short-time or instantaneous protection function can initiate circuit interruption according to the configured settings.
The PR111/P uses digital microprocessor technology and DIP switches for setting protection parameters. Its front panel also includes LED indicators for protection alarms, allowing maintenance personnel to identify certain abnormal operating conditions.
Another important feature is its backup protection function. If the first opening command does not successfully operate the circuit breaker’s opening mechanism, the release can repeatedly issue TRIP commands until the breaker opens or the current disappears.
The PR111/P is intended for integration with compatible three-pole, three-pole with external neutral, and four-pole Emax circuit breakers. The exact breaker frame, rated current transformer configuration, and release version must be checked before selecting a replacement.
For industrial electrical maintenance teams, the ABB PR111/P LSI provides electronic overcurrent protection for compatible SACE Emax circuit breakers, supporting coordinated protection of low-voltage power distribution equipment.
| Parameter | Specification |
|---|---|
| Manufacturer | ABB |
| Model | PR111/P |
| Product Type | SACE Emax Electronic Trip Unit |
| Protection Configuration | LSI |
| Product Family | SACE Emax |
| Release Technology | Digital Microprocessor |
| Power Supply | Self-Powered |
| Protection Functions | Long-Time, Short-Time, Instantaneous |
| L Protection | Overload with Inverse Long-Time Delay |
| S Protection | Short-Circuit with Adjustable Delay |
| I Protection | Instantaneous Short-Circuit |
| Setting Method | DIP Switches |
| Monitoring Functions | Protection, Watchdog and Test |
| Alarm Indication | Front-Panel LEDs |
| Circuit Breaker Compatibility | Three-Pole, Three-Pole with External Neutral, Four-Pole |
| Applicable Standard | IEC 60947-2 |
| Nominal Service Frequency | 50/60 Hz ±10% |
| Dimensions | 362 × 65 × 195 mm |
| Weight | 2.3 kg |
The ABB PR111/P LSI operates by measuring current through the current transformers installed in the SACE Emax circuit breaker. Its microprocessor evaluates the measured current against the configured protection parameters and determines whether a trip command is required.
The protection process consists of three principal functions.
Long-Time Overload Protection (L)
The L function protects electrical circuits against sustained overload conditions.
When current exceeds the configured long-time pickup threshold, the electronic release begins evaluating the overload condition according to its inverse-time characteristic.
This allows temporary current increases without immediately opening the circuit breaker. If the overload continues, the release initiates a trip command after the corresponding delay.
In applications involving electric motors and industrial distribution feeders, this function helps protect conductors and connected electrical equipment against prolonged excessive current.
Short-Time Short-Circuit Protection (S)
The S function responds to short-circuit currents that exceed the configured short-time threshold.
Unlike instantaneous protection, short-time protection includes an adjustable delay. This allows coordination between upstream and downstream circuit breakers.
For example, when a fault occurs in a downstream distribution branch, the downstream breaker can be given the opportunity to interrupt the fault before the upstream Emax breaker trips.
The PR111/P supports selectable short-time protection characteristics, including constant-time and inverse-time behavior, according to the applicable settings.
Instantaneous Short-Circuit Protection (I)
The I function responds to high short-circuit currents without an intentional time delay.
When the measured current reaches the configured instantaneous threshold, the electronic release issues a trip command to interrupt the circuit.
This function is particularly important for severe short-circuit conditions where rapid disconnection is required to limit electrical and thermal stress.
Current Measurement and Self-Powered Operation
The current transformers installed in the circuit breaker provide both the current measurement signals and the energy required for the electronic release.
The PR111/P uses these signals to calculate the current flowing through the circuit breaker and evaluate the protection conditions.
An important selection consideration is that the reference current for the PR111/P is the rated current of the current transformers (In), rather than the uninterrupted rated current of the circuit breaker itself (Iu).
Trip Command and Backup Protection
When a protection condition requires interruption, the PR111/P sends a command to the circuit breaker’s opening solenoid (SA).
The solenoid operates the mechanical opening mechanism, separating the breaker contacts and interrupting the current.
If the first opening command does not successfully open the circuit breaker, the backup protection function repeatedly issues TRIP commands until the breaker opens or the current disappears.
The PR111/P LSI serves as the electronic protection component inside the ABB SACE Emax air circuit breaker. It monitors electrical current and controls the trip operation through the circuit breaker’s opening mechanism.
A simplified protection arrangement follows this structure:
Power Supply → Current Transformers → PR111/P LSI → Opening Solenoid → Circuit Breaker Contacts
| System Component | Function |
|---|---|
| ABB PR111/P LSI | Evaluates overcurrent conditions and initiates circuit breaker tripping |
| Current Transformers | Measure circuit current and supply operating energy to the release |
| Opening Solenoid (SA) | Operates the circuit breaker’s mechanical opening mechanism |
| SACE Emax Circuit Breaker | Interrupts the electrical circuit during a fault |
| L Protection | Provides long-time overload protection |
| S Protection | Provides delayed short-circuit protection |
| I Protection | Provides instantaneous short-circuit protection |
| Front-Panel DIP Switches | Configure protection parameters |
| Alarm LEDs | Indicate L and S protection alarm conditions |
| Watchdog Function | Monitors the protection release operating condition |
| Test Function | Supports protection release testing |
In an industrial distribution panel, the PR111/P receives current information from the current transformers mounted in the Emax breaker. It evaluates the current against the selected protection settings and initiates the opening mechanism when a fault condition is detected.
Its LSI functions also allow protection coordination between circuit breakers at different distribution levels.
| Application | Typical Use |
|---|---|
| Industrial Power Distribution | Overcurrent protection for low-voltage distribution feeders |
| Manufacturing Plants | Protecting production equipment and electrical distribution circuits |
| Motor Control Systems | Protecting compatible motor supply feeders against overload and short circuits |
| Power Distribution Panels | Monitoring current and initiating circuit interruption during faults |
| Transformer Protection | Supporting downstream low-voltage distribution protection |
| Chemical Processing Plants | Protecting electrical feeders supplying process equipment |
| Oil and Gas Facilities | Overcurrent protection in industrial power distribution systems |
| Water Treatment Plants | Protecting electrical circuits supplying pumps and auxiliary equipment |
| Mining Operations | Protecting distribution circuits supplying industrial machinery |
| Commercial Electrical Installations | Supporting protection of compatible low-voltage power distribution systems |
| Component | Function |
|---|---|
| ABB PR111/P LSI | Electronic trip unit with long-time, short-time, and instantaneous protection |
| ABB SACE Emax | Compatible low-voltage air circuit breaker family |
| ABB Current Transformers | Measure phase and neutral currents |
| ABB Opening Solenoid (SA) | Operates the circuit breaker opening mechanism |
| ABB Emax Three-Pole Circuit Breaker | Three-phase circuit interruption |
| ABB Emax Three-Pole with External Neutral | Three-phase protection with external neutral measurement |
| ABB Emax Four-Pole Circuit Breaker | Three-phase and neutral circuit interruption |
| ABB PR121/P LSI | Electronic protection release for compatible New Emax configurations |
| ABB PR111/P LI | Electronic trip unit with long-time and instantaneous protection |
| ABB PR111/P LSIG | Electronic trip unit with long-time, short-time, instantaneous, and earth-fault protection |
| Model | Product Type | Typical Application |
|---|---|---|
| ABB PR111/P LI | SACE Emax Electronic Trip Unit | Overload and instantaneous short-circuit protection |
| ABB PR111/P LSIG | SACE Emax Electronic Trip Unit | Overcurrent and earth-fault protection |
| ABB PR121/P LSI | New Emax Electronic Trip Unit | Replacement protection configuration |
| ABB PR121/P LSIG | New Emax Electronic Trip Unit | Overcurrent and earth-fault protection |
| ABB PR112/P LSI | SACE Emax Electronic Trip Unit | Advanced electronic circuit breaker protection |
| ABB PR113/P LSIG | SACE Emax Electronic Trip Unit | Advanced protection with earth-fault functionality |
LSI refers to three protection functions: L for long-time overload protection, S for short-time short-circuit protection, and I for instantaneous short-circuit protection. This configuration provides different response characteristics for sustained overloads and short-circuit faults.
The PR111/P is a self-powered electronic protection release. It obtains its operating energy from the current transformers installed in the circuit breaker. A separate auxiliary power supply is not required for its basic protection operation.
Yes. ABB documentation identifies compatibility with three-pole, three-pole with external neutral, and four-pole circuit breaker configurations. The exact breaker model and current transformer arrangement must still be checked before installation.
Both releases provide long-time, short-time, and instantaneous protection. The LSIG version additionally includes earth-fault protection with adjustable delay. The appropriate version depends on the required electrical protection scheme.