• Schneider NW12N1 Circuit Breaker
  • Schneider NW12N1 Circuit Breaker
  • Schneider NW12N1 Circuit Breaker
  • Schneider NW12N1 Circuit Breaker
Product Overview The Schneider Electric NW12N1 MasterPact Circuit Breaker is a low-voltage air circuit breaker designed for high-current power distribution systems in industrial facilities, commercial b……
Schneider NW12N1 Circuit Breaker
  • Schneider
  • NW12N1
  • Circuit Breaker
  • France
  • 352 x 537 x 297 mm
  • 65 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider NW12N1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW12N1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW12N1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW12N1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW12N1 MasterPact Circuit Breaker is a low-voltage air circuit breaker designed for high-current power distribution systems in industrial facilities, commercial buildings, and electrical infrastructure installations. It belongs to the MasterPact NW family, which is used in main distribution boards, switchboards, and other installations requiring reliable switching, isolation, and short-circuit protection.

The NW12N1 is a W-frame circuit breaker with a rated current of 1250 A and an N1 breaking-capacity class. Its published ultimate short-circuit breaking capacity is 42 kA at 440 V AC. The device is designed for AC power distribution networks and supports electrical isolation in accordance with the applicable IEC 60947-2 requirements.

This product configuration is a four-pole, fixed-mounted circuit breaker frame without a control unit. This distinction is important: the basic frame and the complete circuit breaker equipped with a protection trip unit are not necessarily the same supply configuration. Buyers should confirm the required Micrologic control unit, auxiliary contacts, operating mechanism, and other accessories before placing an order.

The NW12N1 is intended for installations where high-current feeders and distribution circuits need a coordinated protection and switching arrangement. Its application should be evaluated according to the system voltage, available fault current, load characteristics, protection coordination requirements, and the specifications of the complete switchboard.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family MasterPact NW
Model NW12N1
Product Type Air Circuit Breaker / Circuit Breaker Frame
Frame Rating W-frame
Rated Current 1250 A
Performance Class N1
Ultimate Breaking Capacity (Icu) 42 kA at 440 V AC
Rated Operational Voltage (Ue) Up to 690 V AC, 50/60 Hz
Rated Insulation Voltage (Ui) 1000 V AC
Rated Impulse Withstand Voltage (Uimp) 12 kV
Number of Poles 4P
Mounting Type Fixed
Control Unit Not included in the specified configuration
Control Type Push-button
Isolation Suitability Yes, subject to applicable IEC 60947-2 requirements
Selectivity Category Category B
Dimensions 352 × 537 × 297 mm
Weight 65 kg
Typical Application Main power distribution and feeder protection

Note: Electrical ratings depend on the exact breaker configuration and applicable operating conditions. Confirm the complete product reference and manufacturer documentation before installation.

Function and Working Principle

The NW12N1 is designed to perform three important functions in a low-voltage power distribution system: switching, isolation, and protection against abnormal electrical conditions when equipped with the appropriate protection unit.

1. Normal Circuit Switching

An air circuit breaker can connect or disconnect an electrical circuit during normal operating conditions. This allows maintenance personnel and authorized operators to control power distribution to downstream equipment.

The NW12N1 is designed for high-current distribution applications, where switching devices must be selected according to the load current, system voltage, operating frequency, and installation requirements.

2. Overload Protection

An overload occurs when the current flowing through a circuit exceeds its permitted operating level for a period of time. If not addressed, excessive current can cause overheating and damage to cables, busbars, motors, and other electrical equipment.

When fitted with a compatible protection trip unit, the circuit breaker can monitor current conditions and initiate a trip when configured protection thresholds and timing characteristics are exceeded.

The protection settings must be coordinated with the downstream devices and the thermal limits of the protected circuit.

3. Short-Circuit Protection

A short circuit can produce extremely high fault currents. The breaker must interrupt the fault safely within its specified breaking capacity and under the conditions defined by the manufacturer.

The NW12N1 belongs to the N1 performance class, with a published ultimate breaking capacity of 42 kA at 440 V AC. The actual available fault current at the installation point must be calculated and compared with the breaker rating before selection.

4. Four-Pole Circuit Isolation

The four-pole configuration provides switching of three phase conductors and the neutral conductor. This arrangement can be relevant in distribution systems where neutral switching is required by the electrical design.

The suitability of four-pole switching depends on the earthing arrangement, neutral treatment, local electrical regulations, and the protection philosophy of the installation.

5. Arc Interruption

When a circuit breaker interrupts current, an electrical arc can form between separating contacts. Air circuit breakers are designed with an arc-control and interruption system to extinguish the arc and safely interrupt the circuit within the device’s specified operating limits.

The breaker must be installed and maintained according to the manufacturer’s instructions. Contact condition, operating mechanism condition, and correct accessory configuration are important for dependable performance.

Role in Industrial Power Distribution Systems

The Schneider NW12N1 can serve as a main or feeder protection device in a low-voltage distribution installation. Its role depends on the electrical architecture and the protection coordination strategy.

Main Incoming Protection

In a suitable switchboard, a high-current air circuit breaker can be installed as the main incoming protective device. It provides a means of switching and protecting the incoming supply before power is distributed to downstream busbars and feeder circuits.

The selected breaker must match the system’s rated current, short-circuit level, and protection requirements.

Feeder Circuit Protection

The NW12N1 may also be used in an appropriately engineered feeder arrangement. It can protect a large distribution branch supplying downstream panels, production equipment, or other electrical loads when the selected protection unit and settings are suitable.

Electrical Isolation for Maintenance

A circuit breaker with suitable isolation characteristics can support maintenance procedures by disconnecting the relevant circuit from the power source.

Isolation must always be verified using the approved safety procedure. Opening a breaker alone should not be treated as a substitute for lockout, verification of absence of voltage, and other required safety controls.

Protection Coordination

The breaker forms part of a wider protection system that may include upstream transformers, downstream breakers, protective relays, busbars, and metering equipment.

Protection coordination is necessary to help ensure that a fault is cleared by the appropriate protective device while minimizing unnecessary interruption to unaffected parts of the installation.

Industrial Applications

The NW12N1 is designed for high-current low-voltage distribution systems. Typical application environments include:

1. Industrial Main Distribution Boards

Large manufacturing facilities use main distribution boards to distribute electrical power to production lines, auxiliary systems, lighting, and building services.

A 1250 A air circuit breaker may be considered for a main incoming or distribution position where its current and fault-interruption ratings match the system design.

2. Factory Power Distribution

Factories often contain multiple production areas with different electrical loads. The NW12N1 can be used in a suitable distribution arrangement to control and protect a high-current feeder supplying downstream switchboards or industrial equipment.

3. Commercial Buildings

Large commercial buildings may require high-capacity low-voltage distribution equipment for HVAC systems, elevators, lighting, and other electrical services.

The breaker configuration must be selected according to the building’s electrical design, load calculations, and protection coordination requirements.

4. Utility and Infrastructure Installations

Infrastructure facilities may contain large electrical distribution systems that supply pumps, ventilation equipment, auxiliary power, and control systems.

A high-current circuit breaker can provide switching and protection for an appropriately rated distribution circuit.

5. Data Centers and Critical Facilities

Data centers require carefully coordinated electrical distribution systems to support servers, cooling equipment, UPS systems, and auxiliary loads.

The NW12N1 may be considered for a suitable low-voltage distribution position, provided its ratings, protection unit, selectivity characteristics, and system configuration meet the facility’s engineering requirements.

Installation and System Integration

The NW12N1 is a large, high-current electrical device. Installation must be performed by qualified personnel using the applicable switchboard drawings, manufacturer instructions, and local electrical regulations.

1. Verify the Complete Product Configuration

Before installation, confirm the complete product reference and determine whether the supplied item is a basic breaker frame or a fully equipped circuit breaker.

The specified configuration is listed without a control unit. Confirm whether a compatible Micrologic trip unit and required accessories are supplied separately.

2. Confirm System Voltage and Current

Check that the electrical system is compatible with the breaker’s rated operational voltage and current.

The 1250 A rating should not be treated as a substitute for a complete load calculation. Engineers must consider continuous load, overload conditions, ambient temperature, installation arrangement, and the ratings of connected conductors and busbars.

3. Evaluate Short-Circuit Conditions

Determine the prospective short-circuit current at the installation point. Compare the calculated value with the NW12N1’s specified breaking capacity at the applicable voltage.

The published N1 rating is 42 kA at 440 V AC. The applicable value must be checked against the manufacturer’s technical data for the actual system voltage and configuration.

4. Confirm Fixed-Mounting Requirements

The NW12N1 configuration covered here is fixed-mounted. Verify the switchboard structure, mounting supports, connection arrangement, busbar dimensions, and terminal access before installation.

The supplied dimensions are 352 × 537 × 297 mm. Allow sufficient space for connections, operation, inspection, and maintenance.

5. Check the Four-Pole Arrangement

Confirm the phase and neutral connection layout. The neutral conductor must be connected and treated according to the system’s earthing arrangement and applicable design requirements.

Incorrect neutral switching or wiring can affect protection performance and system safety.

6. Configure the Protection Unit

If the breaker is supplied with a compatible trip unit separately, configure its protection functions according to the system study and coordination requirements.

Settings should be reviewed by qualified protection engineers. Do not copy settings from another installation without verifying the actual system parameters.

7. Commissioning and Testing

Before energization, inspect the mounting, connections, terminal tightness, insulation condition, grounding, and accessory installation.

Perform the required mechanical and electrical checks in accordance with the manufacturer’s commissioning procedures. Confirm that the protection system operates as designed before placing the distribution board into service.

Compatible System Components

The NW12N1 is normally installed as part of a complete low-voltage switchboard. The following components may be used in a suitable system design.

Component Function Integration Considerations
Micrologic protection unit Provides configurable current protection and monitoring functions Confirm exact compatibility with the NW12N1 frame and required protection functions
Auxiliary contacts Provide breaker status signals Verify contact type, voltage, and accessory reference
Shunt trip release Enables remote electrical tripping Confirm control voltage and accessory compatibility
Undervoltage release Trips or prevents closing under specified undervoltage conditions Verify the required operating voltage and breaker configuration
Motor mechanism Supports electrical charging or operating functions where applicable Confirm the required mechanism and control supply
Switchboard busbars Carry current between distribution devices Verify current rating, short-circuit withstand capability, and connection dimensions
Current transformers or metering devices Support measurement and monitoring Select according to the switchboard’s measurement and protection design
Downstream circuit breakers Protect individual feeders and loads Coordinate trip settings and short-circuit ratings
Electrical protection relay Provides additional system-level protection where required Confirm coordination with the main breaker protection unit

The components listed above are examples of equipment used in a complete installation. They are not necessarily included with the NW12N1 basic frame.

Alternative Models and Replacement Considerations

The MasterPact NW family includes different frame ratings and breaking-capacity classes. A replacement must be selected according to the original electrical design rather than physical appearance alone.

Model or Option Main Difference Replacement Consideration
MasterPact NW12H1 Higher N1-family frame performance class, 65 kA at 440 V AC Confirm the required short-circuit rating and exact mounting configuration
MasterPact NW12H2 Higher breaking-capacity class, 100 kA at 440 V AC May be considered where the calculated fault level requires it
MasterPact NW10N1 1000 A frame rating Not a direct substitute for a 1250 A requirement
MasterPact NW16N1 1600 A frame rating Requires review of busbars, protection settings, and system design
Current-generation MasterPact products Newer product family options Requires detailed mechanical, electrical, and accessory compatibility assessment

Before selecting an alternative, verify:

  • Rated current and frame size.
  • Rated operational voltage.
  • Ultimate and service short-circuit breaking capacities.
  • Number of poles.
  • Fixed or drawout mounting arrangement.
  • Trip unit and protection functions.
  • Auxiliary contacts and release accessories.
  • Busbar and terminal connections.
  • Mechanical dimensions and switchboard compatibility.
  • Protection coordination and commissioning requirements.

A circuit breaker with the same rated current may still be unsuitable if its breaking capacity, mounting type, pole arrangement, or trip-unit configuration differs.

Key Advantages

High-Current Distribution Capability

The 1250 A rating makes the NW12N1 suitable for appropriately designed high-current low-voltage distribution circuits.

Short-Circuit Interruption

Its N1 performance class provides a published 42 kA ultimate breaking capacity at 440 V AC, subject to the manufacturer’s specified conditions.

Four-Pole Configuration

The four-pole arrangement supports applications where three phase conductors and the neutral conductor must be switched.

Fixed-Mounting Design

The fixed configuration is intended for switchboards designed around stationary breaker installation.

Electrical Isolation Suitability

The breaker is designed to support isolation in accordance with applicable IEC 60947-2 requirements.

Integration with MasterPact Accessories

The MasterPact NW platform supports a range of protection and auxiliary accessories. The exact accessories must be verified against the specific breaker frame and configuration.

Technical FAQs

1. What is the Schneider Electric NW12N1?

The NW12N1 is a MasterPact NW low-voltage air circuit breaker frame designed for high-current power distribution applications.

2. What is the rated current of the NW12N1?

The rated current is 1250 A at the manufacturer’s specified reference conditions.

3. What is the breaking capacity?

The N1 version has a published ultimate short-circuit breaking capacity of 42 kA at 440 V AC. Confirm the applicable rating at the actual system voltage before installation.

4. Is the NW12N1 a three-pole or four-pole breaker?

The product configuration described here is four-pole. Other NW12N1 variants may have different pole and mounting arrangements, so the complete product reference must be checked.

5. Does this model include a Micrologic trip unit?

The specified configuration is listed without a control unit. Confirm whether a compatible Micrologic unit is included or needs to be purchased separately.

6. Is the NW12N1 fixed-mounted?

Yes. The configuration described here is fixed-mounted. A drawout version is a different installation arrangement and should not be assumed interchangeable.

7. What is the operating voltage?

The published rated operational voltage is up to 690 V AC, 50/60 Hz. The breaking-capacity rating must be checked at the actual operating voltage.

8. What are the dimensions and weight?

The supplied listing dimensions are 352 × 537 × 297 mm, and the supplied weight is 65 kg. These values match the published specifications for the four-pole fixed configuration.

9. Can the NW12N1 be used as a main incoming breaker?

It may be used in a suitable main distribution position if its current rating, breaking capacity, pole arrangement, protection unit, and installation requirements match the system design.

10. Can it replace another MasterPact NW breaker?

Not automatically. Confirm frame rating, breaking capacity, pole count, mounting type, trip unit, accessories, and connection dimensions before replacement.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric NW12N1, verify the full product reference and distinguish between a basic breaker frame and a complete circuit breaker assembly.

For this configuration, confirm the 1250 A rating, N1 breaking-capacity class, 42 kA rating at 440 V AC, four-pole arrangement, fixed mounting, and absence or presence of a protection control unit.

For new, surplus, or refurbished equipment, request clear photographs of the nameplate, terminals, operating mechanism, and installed accessories. Confirm the breaker condition, testing status, and warranty terms. If the product is supplied without a trip unit, identify the required compatible protection unit before purchase.

Maintenance should follow the manufacturer’s instructions and the facility’s electrical maintenance program. Inspection may include checking the operating mechanism, contact condition, terminal connections, insulation, auxiliary circuits, and protection settings. Any maintenance or testing must be performed by qualified personnel using appropriate electrical safety procedures.

For replacement projects, review the switchboard layout, busbar connections, available installation space, short-circuit level, and protection coordination. A different MasterPact model may require changes to the switchboard or protection scheme even when its rated current is similar.

Conclusion

The Schneider Electric NW12N1 MasterPact air circuit breaker is a 1250 A low-voltage power distribution device with an N1 breaking-capacity class and a published 42 kA ultimate short-circuit breaking capacity at 440 V AC. The described configuration is a four-pole, fixed-mounted breaker frame without a control unit.

With dimensions of 352 × 537 × 297 mm and a weight of 65 kg, it is intended for substantial switchboard installations rather than compact branch-circuit applications. Correct selection requires verification of the complete breaker configuration, protection unit, electrical ratings, and switchboard compatibility.

For industrial maintenance and power distribution projects, confirming the exact product reference and supplied accessories is essential before purchasing or replacing the NW12N1.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501