The Schneider Electric NW08N1 MasterPact NW Circuit Breaker is a low-voltage power circuit breaker designed for electrical distribution systems that require high-current switching, overload protection, and short-circuit fault interruption. It belongs to the MasterPact NW family, a range of air circuit breakers developed for industrial facilities, commercial buildings, infrastructure installations, and large electrical distribution networks.
The NW08N1 is an 800 A frame-rated circuit breaker with an N1 performance level. Its documented short-circuit breaking capacity is 42 kA at 440 V AC. The device is designed for demanding power distribution applications where reliable protection and controlled circuit isolation are important.
The configuration associated with the supplied dimensions and weight is a four-pole, fixed-mounted version without a control unit. The four-pole arrangement allows the breaker to switch and protect a three-phase system with a neutral conductor, subject to the selected protection configuration and electrical system design.
As a major component in a low-voltage switchboard, the NW08N1 can be used as an incoming main breaker, bus-section breaker, or feeder protection device. Its selection must be based on the installation’s rated current, prospective short-circuit current, system voltage, grounding arrangement, and coordination requirements.
The complete configuration should always be verified before ordering. The basic NW08N1 model designation does not, by itself, identify every mechanical and electrical option. Pole count, fixed or drawout mounting, trip unit, accessories, and control arrangements may vary between versions.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Family | MasterPact NW |
| Model | NW08N1 |
| Product Type | Low-Voltage Air Circuit Breaker |
| Device Application | Power Distribution Protection |
| Frame Rating | 800 A |
| Poles | 4P configuration corresponding to supplied dimensions |
| Mounting Type | Fixed-mounted configuration |
| Control Unit | Without control unit in the referenced configuration |
| Performance Level | N1 |
| Rated Operational Voltage | Up to 690 V AC, depending on system configuration |
| Rated Frequency | 50/60 Hz |
| Ultimate Short-Circuit Breaking Capacity (Icu) | 42 kA at 440 V AC |
| Service Short-Circuit Breaking Capacity (Ics) | 42 kA at 440 V AC |
| Short-Time Withstand Current (Icw) | 42 kA for 1 second; 22 kA for 3 seconds |
| Rated Insulation Voltage (Ui) | 1000 V AC |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Suitability for Isolation | Yes, subject to applicable standards and configuration |
| Standards | EN/IEC 60947-1 and EN/IEC 60947-2 |
| Dimensions Provided | 352 × 537 × 297 mm |
| Weight Provided | 65 kg |
| Typical Applications | Main distribution, feeder protection, industrial switchboards |
Important: The technical data above describes the 4-pole fixed-mounted configuration associated with the supplied dimensions and weight. Verify the exact catalog reference and installed accessories before purchase or replacement.
The NW08N1 is designed to protect electrical distribution circuits by detecting abnormal current conditions and interrupting the circuit when the installed protection arrangement determines that a trip is necessary.
An overload occurs when the current flowing through an electrical circuit exceeds its permitted operating level for a sustained period. This can happen when too much equipment is connected to a feeder, a motor operates under excessive mechanical load, or a downstream fault creates abnormal current demand.
A suitable protection unit monitors the current and initiates a trip when the overload condition exceeds the configured protection limits.
The breaker frame and the selected protection unit must be matched to the electrical system. The 800 A frame rating should not be interpreted as meaning that every installation automatically operates at 800 A. Actual protection settings depend on the trip unit, sensor rating, conductor capacity, and system coordination.
A short circuit can produce a very high fault current over a short period. If not interrupted promptly, this current can cause severe thermal and mechanical stress on busbars, cables, transformers, and connected equipment.
The NW08N1 N1 performance class provides a documented 42 kA breaking capacity at 440 V AC. The breaker must be selected so that its interrupting capacity is suitable for the prospective fault current at the installation point.
The protection design should also consider fault-clearing time, upstream and downstream protection coordination, and the withstand ratings of the connected switchgear.
Circuit breakers are also used to isolate electrical equipment during maintenance and system changes. The MasterPact NW family is suitable for isolation in accordance with the applicable standards when correctly configured and installed.
Isolation procedures must still follow site safety rules. The breaker should not be treated as a substitute for all required lockout, verification, and electrical safety procedures.
The four-pole configuration provides switching for three phase conductors and the neutral conductor. This can be useful in distribution systems where neutral switching is required by the electrical design.
The neutral protection and switching arrangement must be selected according to the system grounding method, applicable electrical regulations, and the specific breaker configuration.
The NW08N1 can serve as a key switching and protection device in low-voltage power distribution equipment.
In a main distribution switchboard, the breaker can be installed at the incoming supply point to provide switching and protection for the downstream distribution system.
It helps protect the main busbar assembly and downstream feeders when coordinated with the upstream transformer protection and other circuit breakers.
The breaker can also be used to protect a high-current feeder supplying industrial machinery, distribution panels, or process equipment.
Its frame rating and interrupting capability must be matched to the load and available fault current. A properly designed protection system should prevent a fault on one feeder from unnecessarily interrupting the entire facility.
In some switchboard arrangements, a circuit breaker is used to connect or separate two busbar sections. This supports power distribution flexibility and can assist with maintenance or load-transfer operations.
Whether the NW08N1 is appropriate for a bus-coupler role depends on the switchboard design, interlocking requirements, protection settings, and electrical ratings.
A complete MasterPact installation may use compatible auxiliary contacts, trip units, communication accessories, and monitoring equipment to provide breaker status and electrical information to a supervisory system.
However, the specified configuration is described as being without a control unit. Do not assume that advanced protection, metering, or communication functions are included in the basic breaker frame.
Large manufacturing plants use low-voltage distribution systems to supply production lines, machine tools, motors, pumps, compressors, and auxiliary equipment.
An 800 A MasterPact NW breaker may be used as a main or feeder protection device where its current and short-circuit ratings match the installation.
Electrical distribution rooms require switching equipment capable of managing high-current circuits and responding to abnormal operating conditions.
The NW08N1 can be incorporated into suitable switchboards to protect incoming supplies, distribution sections, or large feeders.
Large commercial buildings may have substantial electrical loads from HVAC systems, elevators, lighting distribution, pumps, and other building services.
A correctly selected air circuit breaker can provide protection and switching for major distribution circuits. The protection design must account for the building’s load profile and electrical fault levels.
Data centers require carefully coordinated electrical distribution systems to support servers, cooling equipment, UPS systems, and backup power infrastructure.
MasterPact NW breakers may be used in suitable low-voltage switchboards as part of the power distribution and protection architecture. Selection must consider fault levels, selectivity, redundancy, and the operating requirements of critical loads.
Water treatment facilities, transportation infrastructure, industrial utilities, and other large installations often require high-current distribution equipment.
The NW08N1 may be considered for applications where its 800 A frame rating, N1 breaking performance, and mechanical configuration meet the system requirements.
Correct installation is essential for safe operation and reliable circuit protection.
Before installation, confirm the system voltage, frequency, rated current, and prospective short-circuit current.
The NW08N1 N1 configuration has a documented 42 kA breaking capacity at 440 V AC. The selected breaker must have an interrupting rating equal to or greater than the prospective fault current at its installation point.
Do not select a breaker solely on the basis of its 800 A frame rating.
The supplied dimensions of 352 × 537 × 297 mm and weight of 65 kg correspond to the four-pole fixed-mounted configuration.
A three-pole fixed version and a drawout version have different dimensions and weights. Before designing a switchboard or ordering a replacement, verify the pole count, mounting method, terminal arrangement, and exact product reference.
The breaker must be installed in a switchboard designed to accommodate its dimensions, weight, electrical clearances, and connection requirements.
Check the supporting structure, mounting points, busbar arrangement, cable bending space, and access for inspection and maintenance.
The breaker should be handled using suitable lifting equipment and approved procedures because of its substantial weight.
Main circuit connections must be made using suitable conductors and busbars with appropriate current-carrying capacity.
Connection surfaces should be clean and properly prepared. Tightening torques must follow the manufacturer’s installation documentation. Incorrect connections can create localized heating, increased contact resistance, and equipment damage.
The selected protection unit and settings must coordinate with upstream and downstream protective devices.
The engineering study should consider overload protection, short-circuit protection, ground-fault requirements where applicable, selectivity, and the thermal withstand capability of cables and busbars.
Because the referenced configuration is without a control unit, the required trip unit and protection functionality must be confirmed separately.
Before energizing the installation, inspect the mechanical assembly, electrical connections, grounding, and protective arrangements.
Commissioning should include the appropriate mechanical operation checks, trip-unit verification where installed, auxiliary-contact checks, interlock testing, and electrical tests specified by the manufacturer and applicable standards.
Testing should be carried out by qualified personnel using approved procedures.
A MasterPact NW breaker is normally part of a larger switchboard and protection system.
| Component | Function | Compatibility Considerations |
|---|---|---|
| MasterPact NW trip unit | Provides configured protection functions | Confirm the exact breaker and trip-unit compatibility |
| Current sensors | Provide current information for protection | Match sensor rating and breaker configuration |
| Auxiliary contacts | Indicate breaker open or closed status | Confirm contact type and accessory compatibility |
| Shunt trip | Allows remote electrical tripping | Verify control voltage and accessory reference |
| Undervoltage release | Trips or prevents closing under specified voltage conditions | Confirm rated control voltage and installation requirements |
| Closing release | Supports electrical closing where configured | Check the operating mechanism and control circuit |
| Switchboard busbars | Carry the main distribution current | Verify current and short-circuit withstand ratings |
| Protection relay or monitoring system | Supports system-level protection and monitoring | Confirm the required interface and protection coordination |
| PLC or SCADA system | Monitors system status and coordinates operations | Requires compatible auxiliary contacts or communication accessories |
| Electrical enclosure | Houses the breaker and distribution equipment | Must meet the mechanical and environmental requirements |
These components are not necessarily included with the basic NW08N1 breaker frame. Confirm the actual supplied configuration before purchasing accessories or planning system integration.
The MasterPact NW family includes different frame sizes and performance levels. Replacement selection must be based on electrical and mechanical compatibility rather than model-family similarity alone.
| Related Model | General Description | Replacement Considerations |
|---|---|---|
| NW08N1 | 800 A frame, N1 performance | Reference model; verify poles, mounting, and trip unit |
| NW08H1 | 800 A frame, higher interrupting performance | Different short-circuit rating; check system requirements |
| NW08H2 | 800 A frame, higher interrupting performance | Confirm voltage-dependent breaking capacity and configuration |
| NW08H3 | 800 A frame, higher interrupting performance | Not automatically interchangeable with N1 |
| NW12N1 | 1200 A frame, N1 performance | Higher frame rating; requires complete electrical and mechanical review |
| Current-generation MasterPact range | Newer low-voltage circuit breaker options | May require switchboard, accessory, and protection-system modifications |
Before selecting a replacement, compare:
A breaker with a higher current rating or interrupting capacity is not automatically a suitable replacement. The complete electrical protection design must be reviewed before substitution.
The 800 A frame rating makes the NW08N1 suitable for selected main and feeder distribution applications in industrial and commercial switchboards.
Its N1 performance class provides a documented 42 kA short-circuit breaking capacity at 440 V AC, subject to the specified configuration and applicable ratings.
The four-pole configuration supports switching of three-phase conductors and the neutral conductor where required by the distribution design.
The MasterPact NW family is suitable for isolation in accordance with applicable standards when correctly configured and installed.
The breaker can be incorporated into appropriately designed low-voltage switchboards and coordinated with other protective devices.
The MasterPact NW family supports a range of accessories and protection configurations. These allow engineers to select functions according to the requirements of the electrical distribution system.
The NW08N1 is a MasterPact NW low-voltage air circuit breaker with an 800 A frame rating and N1 short-circuit performance.
The frame rating is 800 A. The actual protection rating depends on the installed sensor and trip-unit configuration.
The N1 version has a documented 42 kA breaking capacity at 440 V AC. Always check the applicable voltage and rating standard for the specific installation.
N1 identifies the breaker performance class. It distinguishes this version from other MasterPact NW models with different short-circuit breaking capabilities.
The NW08N1 family designation alone does not fully identify the pole configuration. The dimensions and weight supplied here correspond to a four-pole fixed-mounted version. Confirm the exact product reference before ordering.
The referenced four-pole fixed configuration is specified without a control unit. The required protection unit and accessories must be selected separately according to the application.
The supplied dimensions are 352 × 537 × 297 mm, and the weight is 65 kg. These values correspond to the four-pole fixed-mounted configuration.
It can be used as a main breaker when its voltage, current, interrupting capacity, protection settings, and mechanical configuration meet the requirements of the electrical system.
The breaker itself provides the switching and protection functions. Remote status monitoring or control requires compatible auxiliary contacts, releases, communication accessories, or external monitoring equipment.
Confirm the complete model reference, pole count, mounting type, control-unit configuration, rated current, short-circuit rating, accessories, physical condition, and test status. For a replacement project, also verify switchboard compatibility and protection coordination.
When purchasing the Schneider Electric NW08N1, verify the complete product configuration rather than relying only on the basic model designation. In particular, confirm whether the required unit is three-pole or four-pole, fixed-mounted or drawout, and supplied with or without a trip unit.
For used or surplus equipment, request clear photographs of the nameplate, terminals, operating mechanism, and accessories. Check for signs of mechanical damage, overheating, corrosion, contamination, and abnormal wear. Confirm whether inspection or functional testing has been performed.
During maintenance, follow the manufacturer’s recommended inspection and servicing procedures. Check the main contacts, connection points, operating mechanism, auxiliary circuits, and installed protection components. Any signs of overheating, abnormal contact wear, or mechanical malfunction should be investigated by qualified personnel.
For critical power distribution systems, maintain accurate records of breaker settings, test results, accessory references, and maintenance history. These records help support future troubleshooting and replacement planning.
The Schneider Electric NW08N1 MasterPact NW is an 800 A low-voltage air circuit breaker designed for industrial and commercial power distribution systems. Its N1 performance class provides a documented 42 kA short-circuit breaking capacity at 440 V AC.
The supplied dimensions of 352 × 537 × 297 mm and weight of 65 kg correspond to a four-pole fixed-mounted configuration. Before installation or replacement, engineers should verify the exact pole count, mounting arrangement, trip-unit requirements, electrical ratings, and switchboard compatibility.
Accurate configuration identification is essential for maintaining safe and reliable power distribution, particularly in installations where high-current switching and short-circuit protection are critical.