Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Honeywell 2MLI-CPUH is a High Performance CPU Module for the MasterLogic-200 PLC system. It belongs to the non-redundant ML200-IEC controller family and serves as the central processing unit responsible for executing the user program, coordinating I/O operations, and managing the control logic of connected automation equipment.
Unlike the standard 2MLI-CPUS, the 2MLI-CPUH offers a larger program memory capacity and supports a greater number of I/O points. It supports up to 6,144 I/O points and provides 3.5 MB of program memory, making it suitable for applications involving more extensive control sequences, multiple equipment sections, and larger numbers of field signals.
In an industrial production line, the CPU receives process information through the configured input modules, evaluates the programmed conditions, and updates the corresponding output operations. For example, in a material handling system, it can coordinate conveyor sequences, monitor equipment interlocks, process sensor information, and control the operating sequence of connected machinery.
The 2MLI-CPUH operates as part of a modular PLC architecture. It works with the MasterLogic-200 main base, power supply, digital and analog I/O modules, and supported communication modules. This modular arrangement allows the control system to be configured according to the number of field devices and the communication requirements of the installation.
The CPU also supports IEC programming within the MasterLogic-200 platform. Engineers can develop and maintain control applications using the associated programming environment, making the module suitable for machine automation, process equipment, utility systems, and industrial sequence control.
For replacement projects, it is important to distinguish the 2MLI-CPUH from the 2MLI-CPUU. Both support up to 6,144 I/O points, but the CPUU is the Enhanced configuration, while the CPUH is the High Performance version.
| Parameter | Specification |
|---|---|
| Manufacturer | Honeywell |
| Model | 2MLI-CPUH |
| Product Type | High Performance CPU Module |
| Product Series | MasterLogic-200 |
| Controller Architecture | Non-Redundant |
| CPU Classification | High Speed CPU |
| Programming Standard | IEC |
| Maximum I/O Points | 6,144 |
| Program Memory | 3.5 MB |
| System Type | Modular PLC |
| Main Base Compatibility | MasterLogic-200 Main CPU Base |
| I/O Expansion | Supported |
| Compatible I/O Modules | Digital and Analog I/O Modules |
| Programming Environment | SoftMaster |
| Dimensions | 120 × 25 × 110 mm |
| Weight | 0.13 kg |
The 2MLI-CPUH belongs to the High Performance configuration of the MasterLogic-200 CPU family. It handles PLC program execution, evaluates control conditions, and coordinates operations across the connected I/O system. Its processing capacity makes it suitable for control applications with more extensive logic requirements than basic machine controllers.
The CPU provides 3.5 MB of program memory for user application development. This capacity supports more extensive control programs involving equipment sequences, interlocks, process conditions, and multiple machine operating modes.
The module supports a maximum of 6,144 I/O points within the MasterLogic-200 system architecture. This allows engineers to configure larger control systems with multiple digital and analog input/output modules.
The 2MLI-CPUH belongs to the IEC-based MasterLogic-200 CPU family. This programming architecture supports structured development and maintenance of industrial control applications.
The CPU works with compatible MasterLogic-200 I/O bases and expansion modules. Digital inputs, digital outputs, analog inputs, and analog outputs can be arranged according to the field signal requirements of the installation.
The MasterLogic-200 platform supports communication options including Fast Ethernet, RS-232C, RS-422/RS-485, Modbus, Profibus-DP, and DeviceNet through the corresponding system interfaces and modules. This allows the CPU-based control system to participate in different industrial communication architectures.
The 2MLI-CPUH is intended for a fully non-redundant system configuration. Its CPU, power supply, and I/O communication path follow the non-redundant architecture, making it suitable for applications where a single-controller arrangement meets the system requirements.
The MasterLogic-200 platform supports integration with Honeywell Experion systems. This allows PLC control information to be incorporated into broader process monitoring and supervisory environments when the required interfaces and configuration are available.
The MasterLogic-200 platform includes diagnostic capabilities for system and error logs, system monitoring, network monitoring, ping testing, and frame monitoring. These functions assist engineers in identifying communication and controller-related problems during commissioning and maintenance.
The 2MLI-CPUH acts as the processing center of the MasterLogic-200 PLC system. Its operation is based on executing the stored control program and coordinating the exchange of information between field devices and the controller’s I/O modules.
During normal operation, input modules collect signals from connected sensors, switches, transmitters, and other field equipment. These signals are made available to the CPU through the system backplane and configured I/O architecture.
The CPU evaluates the input information against the programmed conditions. It processes interlocks, operating sequences, timing conditions, and other control instructions before updating the corresponding output data.
For example, in an industrial conveyor system, the CPU can evaluate photoelectric sensor signals, motor running feedback, emergency-stop conditions, and equipment interlocks. Based on the programmed sequence, it determines when individual conveyor sections should start or stop.
The output modules then translate the CPU’s output data into the appropriate electrical signals for connected actuators, contactors, valves, and other field equipment.
This process continues as the controller repeatedly executes its application program and processes updated field information. The CPU therefore coordinates the machine’s operating sequence rather than directly handling every electrical input and output signal.
The 2MLI-CPUH also operates alongside the MasterLogic-200 communication architecture. Supported communication interfaces and modules allow the control system to exchange information with supervisory systems, engineering computers, and other industrial devices.
Typical PLC Control Process:
Field Sensors → Digital / Analog Input Modules → 2MLI-CPUH → Control Logic Execution → Output Modules → Motors / Valves / Actuators
Engineering and Configuration Process:
Engineering Computer → SoftMaster → PLC Program Development → CPU Configuration → Program Transfer → System Commissioning
System Communication Structure:
2MLI-CPUH → MasterLogic-200 Backplane → I/O Modules / Communication Modules → Field Equipment and Supervisory Systems
Within the MasterLogic-200 platform, the 2MLI-CPUH serves as the central processing module of a non-redundant PLC configuration. It coordinates the operation of the connected I/O modules and executes the control program responsible for machine or process operation.
The CPU is installed as part of the MasterLogic-200 modular system, working with a compatible main base and power supply. Additional I/O bases and expansion modules can be incorporated according to the required system configuration.
Its High Performance classification distinguishes it from the standard 2MLI-CPUS. The CPUH supports up to 6,144 I/O points with 3.5 MB of program memory, while the CPUU provides the Enhanced configuration with 4 MB of program memory.
This distinction matters when selecting a replacement or expanding an existing PLC system. Engineers should consider the existing application, program capacity, controller configuration, and compatibility with the installed MasterLogic-200 hardware.
| Control System Component | Function |
|---|---|
| 2MLI-CPUH | Executes PLC programs and coordinates system operations |
| 2MLB-M04A | Main CPU base for 4-module installation |
| 2MLB-M06A | Main CPU base for 6-module installation |
| 2MLB-M08A | Main CPU base for 8-module installation |
| 2MLB-M12A | Main CPU base for 12-module installation |
| 2MLP-ACF1 | MasterLogic-200 power supply |
| 2MLP-ACF2 | MasterLogic-200 power supply |
| 2MLI-D Series | Digital input modules |
| 2MLI-R Series | Digital output relay modules |
| 2MLI-A Series | Analog and other input modules |
| 2MLI-T Series | Analog output modules |
| 2MLF Series | Special-function I/O modules |
| Communication Modules | Provide supported industrial network connections |
| SoftMaster | PLC programming and engineering software |
| Application | CPU Function |
|---|---|
| Manufacturing Production Lines | Coordinates machine sequences, interlocks, and equipment operation |
| Material Handling Systems | Controls conveyor sequences, transfer operations, and equipment feedback |
| Packaging Machinery | Processes machine signals and coordinates packaging operations |
| Water Treatment Plants | Manages pump sequences, valve operations, and process-related control logic |
| HVAC Systems | Coordinates equipment operation and processes temperature-related control signals |
| Industrial Pumping Systems | Handles pump sequencing, operating conditions, and protection interlocks |
| Chemical Processing Equipment | Executes process sequences and coordinates field I/O |
| Utility Systems | Controls auxiliary equipment and monitors operating conditions |
| Batch Processing Systems | Executes programmed operating sequences and process interlocks |
| Component | Product Type | Application |
|---|---|---|
| 2MLI-CPUS | Standard CPU Module | MasterLogic-200 standard processing configuration |
| 2MLI-CPUU | Enhanced CPU Module | MasterLogic-200 enhanced processing configuration |
| 2MLI-CPUS/P | Standard CPU Module with Redundant Power | Non-redundant CPU configuration with redundant power |
| 2MLB-M04A | Main CPU Base | Supports 4-module installation |
| 2MLB-M06A | Main CPU Base | Supports 6-module installation |
| 2MLB-M08A | Main CPU Base | Supports 8-module installation |
| 2MLB-M12A | Main CPU Base | Supports 12-module installation |
| 2MLB-E04A | Expansion I/O Base | Supports 4-module expansion |
| 2MLB-E06A | Expansion I/O Base | Supports 6-module expansion |
| 2MLB-E08A | Expansion I/O Base | Supports 8-module expansion |
| 2MLB-E12A | Expansion I/O Base | Supports 12-module expansion |
| 2MLP-ACF1 | Power Supply Module | Supplies power to the MasterLogic-200 system |
| 2MLP-ACF2 | Power Supply Module | Supplies power to the MasterLogic-200 system |
| 2MLI-D21A | Digital Input Module | Acquires 24 V DC field signals |
| 2MLI-R Series | Digital Output Module | Controls compatible field output devices |
| 2MLF Series | Special-Function I/O Module | Provides specialized signal processing functions |
| Model | Product Description |
|---|---|
| 2MLI-CPUS | MasterLogic-200 Standard CPU Module |
| 2MLI-CPUU | MasterLogic-200 Enhanced CPU Module |
| 2MLI-CPUS/P | MasterLogic-200 Standard CPU Module with Redundant Power |
| 2MLB-M06A | MasterLogic-200 6-Slot Main CPU Base |
| 2MLP-ACF1 | MasterLogic-200 Power Supply Module |
| 2MLI-D24A | MasterLogic-200 32-Point Digital Input Module |
Both modules support up to 6,144 I/O points within the MasterLogic-200 system. The 2MLI-CPUH is classified as High Performance and has 3.5 MB of program memory, while the 2MLI-CPUU is the Enhanced version with 4 MB of program memory. They represent different CPU configurations and should be selected according to the existing application and system requirements.
No. The 2MLI-CPUH belongs to the non-redundant 2MLI CPU family. A fully redundant MasterLogic-200 architecture uses the 2MLR-CPUH/T or 2MLR-CPUH/F CPU configurations, together with the corresponding redundant power and I/O communication arrangements.
Yes. The MasterLogic-200 platform supports digital input, digital output, analog input, and analog output modules. The CPU coordinates their operation through the system backplane. The actual I/O arrangement depends on the selected base, installed modules, and project configuration.
Engineers should verify the exact CPU model, PLC program, hardware configuration, I/O assignments, communication settings, and installed power supply. The replacement CPU should match the existing system requirements, and the application should be checked before returning the equipment to normal operation.