Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider Electric MVS06N EasyPact Air Circuit Breaker is an industrial low-voltage circuit breaker designed for power distribution systems that require dependable circuit protection, electrical isolation, and controlled interruption of fault currents. It belongs to the EasyPact MVS family, which is used in industrial switchboards, commercial electrical installations, and power distribution assemblies.
The MVS06 frame corresponds to a rated current level of 630 A. Air circuit breakers of this class are commonly installed in main distribution panels, incoming supply sections, bus-coupler arrangements, and large feeder circuits. They help protect electrical installations by interrupting current under specified abnormal conditions, including overloads and short circuits, when equipped with a suitable protection trip unit.
The MVS06N designation identifies a model within the EasyPact MVS range. The complete ordering code is important because the available configurations can differ in pole count, installation method, operating mechanism, trip-unit type, and protection functions. Consequently, buyers should confirm the full product reference before ordering a replacement or planning a new switchboard installation.
For industrial facilities, circuit-breaker selection involves more than matching the rated current. Engineers must also evaluate the system voltage, prospective short-circuit current, required breaking capacity, protection coordination, environmental conditions, and operating requirements. A correctly selected breaker helps maintain electrical system integrity while allowing maintenance teams to isolate and manage distribution circuits.
The supplied dimensions for this listing are 301 × 276 × 196 mm, with a weight of 14 kg. These values correspond to the published dimensions and approximate weight for a fixed-mounted, three-pole MVS06 configuration. Confirm the exact catalog number and mounting arrangement before using these values for panel design, installation, or shipping.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Series | EasyPact MVS |
| Model Designation | MVS06N |
| Product Type | Air Circuit Breaker (ACB) |
| Application | Low-voltage power distribution |
| MVS06 Rated Current Class | 630 A |
| Pole Configuration | Available in 3-pole or 4-pole variants across the MVS06 family |
| Rated Operational Voltage | Depends on the specific model and system configuration |
| Rated Insulation Voltage | 1000 V for the relevant MVS06 family specifications |
| Rated Impulse Withstand Voltage | 12 kV for the relevant MVS06 family specifications |
| Rated Frequency | 50/60 Hz, according to the selected configuration |
| Protection | Depends on the selected trip unit and ordering code |
| Installation Type | Fixed or withdrawable, depending on the configuration |
| Dimensions Provided | 301 × 276 × 196 mm |
| Weight Provided | 14 kg |
| Typical Installation | Industrial switchboards and main distribution panels |
Important: These are family-level specifications where indicated. The full MVS06N ordering code and nameplate must be checked to establish the exact voltage rating, breaking capacity, pole count, trip unit, operating mechanism, and mounting arrangement.
The primary function of the MVS06N is to switch and protect a low-voltage power distribution circuit. It provides a means of connecting or disconnecting an electrical circuit and, when fitted with the appropriate protection system, can automatically interrupt current under defined fault conditions.
An overload occurs when a circuit carries more current than its intended operating conditions permit for a sufficient period. Excessive current can cause conductors, terminals, and connected equipment to overheat.
A suitably configured circuit breaker uses its protection system to detect an overload condition and initiate a trip when the applicable protection threshold and time delay are reached.
For a 630 A-class breaker, engineers must set and coordinate the protection according to the downstream equipment, cable ratings, load characteristics, and applicable electrical standards. The rated current alone does not define the complete protection settings.
A short circuit can produce a very high current over a short period. If not interrupted appropriately, this current may cause thermal damage, mechanical stress, and severe electrical hazards.
The breaker must have a suitable rated short-circuit breaking capacity for the installation point. The available fault current at the switchboard should be calculated or otherwise established by qualified electrical engineers before selecting the device.
The complete MVS06N configuration must be checked to confirm its specific breaking-capacity rating and protection features.
Air circuit breakers are used to switch distribution circuits during normal operation and to isolate equipment when required by the system design.
Depending on the installation, an MVS06 unit may serve as an incoming breaker, a feeder breaker, or part of a bus-coupler arrangement. The exact role depends on the distribution architecture and the protection coordination plan.
Circuit isolation procedures must follow the manufacturer’s instructions and applicable electrical safety requirements. Opening a breaker should not be treated as proof that all hazardous energy has been removed; isolation and verification procedures remain necessary before maintenance.
The trip unit determines how the breaker responds to specified electrical conditions. Depending on the selected configuration, protection functions may include long-time overload protection, short-time overcurrent protection, instantaneous short-circuit protection, and ground-fault protection.
Not every MVS06N variant necessarily has the same trip functions. The complete catalog number and installed trip-unit identification should be checked before setting parameters or integrating the breaker into a protection scheme.
When the protection system detects a qualifying fault, the operating mechanism opens the main contacts. The breaker is designed to interrupt the current within its specified operating and breaking limits.
The actual interruption performance depends on the device’s ratings, the fault-current level, the system voltage, and the conditions of the installation. Correct selection and maintenance are essential for dependable operation.
The Schneider Electric MVS06N can serve as a key protective device in a low-voltage distribution system. Its role depends on the location of the breaker and the electrical architecture of the facility.
In a main distribution board, an appropriately rated air circuit breaker can protect the incoming circuit and provide a means of disconnecting the downstream distribution system.
Engineers must confirm the incoming supply characteristics, available fault current, load demand, and required selectivity with upstream protective devices.
The MVS06 frame may be used for a suitably rated feeder supplying downstream distribution boards or large electrical loads.
Protection settings should coordinate with downstream breakers and the ratings of the associated cables and equipment. Proper coordination can help limit the effect of a fault to the affected part of the system.
In some switchboard architectures, a circuit breaker connects two busbar sections. This arrangement may support operational flexibility, load transfer, or continuity planning.
Using a breaker in a bus-coupler role requires appropriate electrical and mechanical interlocking, protection coordination, and switching procedures. The breaker should not be assumed to include these system-level functions merely because it belongs to the EasyPact MVS family.
Some configurations of the EasyPact MVS range support additional monitoring, metering, or communication-related accessories. Availability depends on the specific breaker, trip unit, and accessories installed.
If remote status monitoring or integration with a building management system or industrial supervisory system is required, verify the supported communication interface and accessory list before purchasing.
The MVS06N is intended for appropriately engineered low-voltage power distribution installations. A 630 A-class air circuit breaker may be relevant to facilities with substantial electrical loads and centralized distribution equipment.
Manufacturing facilities commonly use low-voltage switchboards to distribute power to production lines, machine groups, auxiliary systems, and utility equipment.
A correctly specified air circuit breaker can provide incoming or feeder protection for a distribution section. The protection scheme must account for motor starting currents, transformer characteristics, cable ratings, and downstream circuit breakers.
Industrial distribution panels may contain several protective devices arranged to isolate and protect different parts of a facility.
The MVS06N can be considered for a compatible distribution position where its rated current, breaking capacity, mounting arrangement, and trip functions satisfy the system requirements.
Large commercial buildings and infrastructure installations may require air circuit breakers for main or sub-main distribution circuits.
Potential applications include utility distribution rooms, central electrical switchboards, and large building service panels. Final suitability depends on the actual system voltage, fault level, load profile, and applicable local standards.
Industrial facilities often distribute power to motor control centers, pump systems, ventilation equipment, and auxiliary services.
An air circuit breaker may protect the upstream distribution circuit supplying these systems. Individual motors and downstream circuits may require additional protective devices selected for their specific operating characteristics.
Compressed-air systems, cooling equipment, water-treatment systems, and other industrial utilities depend on reliable electrical distribution.
A properly selected breaker can support circuit protection and isolation within the utility distribution architecture. System reliability also depends on preventive maintenance, appropriate protection settings, and coordination with upstream and downstream devices.
Correct installation is essential to the safety and performance of the MVS06N. Work on low-voltage switchboards should be carried out by qualified personnel following the manufacturer’s instructions and applicable electrical codes.
Before installation, confirm the full catalog number, rated current, pole count, rated voltage, breaking capacity, trip-unit type, and mounting method.
The MVS06N designation alone does not establish every configuration detail. If replacing an existing breaker, compare the nameplate and ordering code of the old unit with those of the replacement.
The supplied dimensions are 301 × 276 × 196 mm, and the supplied weight is 14 kg. These values align with the published dimensions and approximate weight for a fixed-mounted three-pole MVS06 configuration.
Confirm that the intended device is the fixed-mounted variant. Withdrawable configurations have different physical dimensions and weights and require a compatible chassis or cradle.
Check panel cutouts, mounting points, terminal clearances, busbar positions, and the required operating space before installation.
Confirm that the breaker is suitable for the system voltage, frequency, and prospective short-circuit current. The rated breaking capacity must be sufficient for the fault current at the installation point.
The rated current should also be coordinated with cable ampacity, load demand, ambient temperature, and the protection requirements of the circuit.
If the breaker uses an adjustable electronic trip unit, verify the protection settings against the approved coordination study or protection design.
Settings should reflect the circuit’s intended role and the ratings of the connected equipment. Unverified or inappropriate settings may result in nuisance trips or inadequate protection.
Busbars, cables, terminals, and connection hardware must be compatible with the selected breaker configuration and rated for the intended current.
Follow the specified connection method and tightening torque. Poor electrical connections can create localized heating, increase resistance, and contribute to equipment failure.
The switchboard must have a suitable protective grounding arrangement. Follow the applicable installation standards for grounding, enclosure bonding, and protection against electric shock.
Before maintenance, isolate the relevant sources, apply lockout procedures, and verify the absence of hazardous voltage. Additional energy sources or backfeeds must be considered as part of the isolation process.
Before energizing the system, inspect the installation, confirm mechanical operation, verify the control and trip circuits, and check all required interlocks.
Carry out the commissioning tests specified by the manufacturer and the project’s electrical engineering requirements. Record the final settings and test results for future maintenance and troubleshooting.
The MVS06N is normally installed as part of a complete electrical distribution assembly. Compatibility depends on the exact breaker configuration and the design of the switchboard.
| Component | Function | Compatibility Considerations |
|---|---|---|
| Low-voltage switchboard | Houses and supports distribution equipment | Verify mounting arrangement, clearances, and assembly ratings |
| Busbar system | Distributes electrical power | Confirm current rating, fault withstand capability, and connection geometry |
| Protection trip unit | Detects specified electrical fault conditions | Verify the exact trip-unit model and available protection functions |
| Upstream circuit breaker | Provides upstream protection and isolation | Coordinate ratings and trip settings with the MVS06N |
| Downstream circuit breakers | Protect individual feeders and loads | Check selectivity and protection coordination |
| Auxiliary contacts | Provide breaker status signals | Confirm compatible accessory references and contact functions |
| Shunt trip or undervoltage release | Supports remote tripping or undervoltage-related operation | Verify availability and compatibility with the specific configuration |
| Operating mechanism | Enables manual or electrical operation | Confirm the mechanism and control-voltage requirements |
| Current transformers or metering accessories | Support monitoring and measurement where required | Check the selected trip unit and measurement architecture |
| Industrial monitoring system | Collects status or electrical data | Verify communication and accessory support before integration |
The components listed above are possible elements of a complete installation. They are not necessarily supplied with the MVS06N itself.
When replacing an MVS06N, engineers should identify the full original catalog number rather than relying only on the MVS06N family designation.
| Alternative or Related Option | Considerations |
|---|---|
| Another EasyPact MVS06 configuration | May be appropriate if current rating, pole count, voltage, breaking capacity, trip unit, and mounting method match |
| EasyPact MVS08 | A higher current frame within the same general family; requires a full electrical and mechanical compatibility review |
| Another Schneider Electric air circuit breaker | May be suitable where its ratings, dimensions, protection features, and accessories meet the application requirements |
| A replacement breaker from a different product family | Requires evaluation of mounting, busbar connections, protection coordination, control wiring, and applicable standards |
Before approving a replacement, compare:
A breaker with the same rated current is not automatically interchangeable. Mechanical fit, fault-interruption capability, protection settings, and accessory compatibility must all be verified.
The MVS06 frame corresponds to a 630 A rated current level, making it relevant to appropriately designed industrial distribution circuits.
The ACB format supports switching and protective interruption in low-voltage distribution assemblies designed for compatible equipment.
The EasyPact MVS family includes different trip-unit and protection configurations. This allows system designers to select suitable protection functionality when the correct model and accessories are specified.
The breaker can be installed in compatible distribution boards, subject to the selected mounting arrangement and electrical ratings.
A correctly selected and installed circuit breaker provides a means of switching and isolating its associated circuit according to the manufacturer’s operating procedures.
The EasyPact MVS family is used in a range of low-voltage distribution applications, making accurate identification of the model, trip unit, and accessories important in maintenance and replacement work.
The MVS06N is a model designation associated with the Schneider Electric EasyPact MVS air circuit breaker range. It is intended for low-voltage power distribution protection.
The MVS06 frame corresponds to a 630 A rated current class. The nameplate and complete ordering reference should be checked to confirm the exact device rating.
The supplied dimensions are 301 × 276 × 196 mm. These match the published dimensions for a fixed-mounted, three-pole MVS06 configuration. Confirm the mounting style before using the dimensions for panel design.
The supplied weight is 14 kg, consistent with the approximate published weight of a fixed-mounted, three-pole MVS06 configuration. Four-pole and withdrawable versions have different dimensions and weights.
An air circuit breaker switches and protects a low-voltage electrical circuit. When equipped with an appropriate protection system, it can interrupt current under specified overload and short-circuit conditions.
The exact breaking capacity depends on the complete model configuration. The relevant EasyPact MVS06 family documentation lists a 50 kA ultimate breaking capacity at 220–440 V AC for the cited configuration. Confirm the full catalog number and nameplate before applying this value to a system design.
The available protection functions depend on the installed trip unit and the full ordering code. Confirm the trip-unit designation before assuming that long-time, short-time, instantaneous, or ground-fault protection is available.
It may be used in a main distribution position if the complete configuration is correctly rated for the supply, load, prospective fault current, and protection requirements. The application must be validated by qualified electrical engineers.
Not without a compatibility review. Voltage rating, breaking capacity, pole count, trip-unit functions, mounting method, busbar connections, and accessories must all be checked.
Confirm the full catalog number, nameplate ratings, trip-unit model, mechanical condition, terminal condition, operating mechanism, and any included accessories. Where appropriate, request inspection and test documentation from the supplier.
When sourcing the Schneider Electric MVS06N, begin by confirming the complete product reference and the installed configuration. The model designation alone does not establish every electrical, mechanical, and protection feature.
For replacement projects, compare the original and replacement nameplates and verify the rated current, system voltage, breaking capacity, pole count, trip unit, operating mechanism, and mounting method. Request clear photographs of the product label and relevant connection points where the configuration is uncertain.
For new or used equipment, confirm the unit’s condition, accessory list, applicable warranty, and availability of technical documentation. Verify whether the product is fixed-mounted or withdrawable, as this affects the dimensions, weight, chassis requirements, and installation procedure.
During maintenance, inspect terminals, busbar connections, mechanical operating components, trip-unit settings, and auxiliary circuits according to the manufacturer’s maintenance guidance. Any evidence of overheating, abnormal wear, contamination, or mechanical damage should be evaluated by qualified personnel.
Protection settings and functional testing should be documented. Changes to the distribution system may require a review of fault levels, coordination studies, and protection settings before the breaker is returned to service.
The Schneider Electric MVS06N EasyPact MVS Air Circuit Breaker is intended for industrial low-voltage power distribution applications. The MVS06 frame corresponds to a 630 A rated current class, and the supplied dimensions of 301 × 276 × 196 mm and weight of 14 kg are consistent with a fixed-mounted, three-pole configuration.
For purchasing, installation, and replacement, the complete catalog number remains essential. Verifying the rated voltage, breaking capacity, pole count, trip unit, operating mechanism, and mounting arrangement helps ensure that the selected breaker is appropriate for the electrical system and the intended application.