Product Overview The Foxboro P0928AW I/A Series 200 Type 5 LSZH Termination Cable is a connection component for Foxboro I/A Series 200 control system installations. It is used to establish the required ……
Foxboro P0928AW I/A Series 200 Type 5 LSZH Termination Cable
  • Foxboro
  • P0928AW
  • Termination Cable
  • USA
  • 1 meter
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 8

Our advantage

Foxboro P0928AW I/A Series 200 Type 5 LSZH Termination Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro P0928AW I/A Series 200 Type 5 LSZH Termination Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro P0928AW I/A Series 200 Type 5 LSZH Termination Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro P0928AW I/A Series 200 Type 5 LSZH Termination Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro P0928AW I/A Series 200 Type 5 LSZH Termination Cable is a connection component for Foxboro I/A Series 200 control system installations. It is used to establish the required electrical connection between compatible system components and their termination interfaces, helping route signals through the control system’s wiring arrangement.

This cable is suited to installations where Type 5 termination cabling is specified. Its LSZH (Low Smoke Zero Halogen) cable construction is relevant to industrial facilities where reducing smoke and halogen-containing emissions during a fire is an important consideration. Typical applications include process automation cabinets, distributed control system installations, and maintenance work involving existing Foxboro infrastructure.

When replacing an existing cable, the P0928AW model designation and specified cable configuration should be checked against the installed system to maintain the intended connection arrangement.


Technical Specifications

Parameter Specification
Brand Foxboro
Model P0928AW
Product Type I/A Series 200 Type 5 LSZH Termination Cable
Product Series I/A Series 200
Cable Type Type 5 Termination Cable
Cable Construction LSZH (Low Smoke Zero Halogen)
Cable Length 1 meter
Shipping Weight 3 kg
Application Industrial control system interconnection
System Compatibility Compatible Foxboro I/A Series 200 configurations
Installation Environment Industrial control cabinets and automation installations
Primary Function Electrical connection between compatible control system interfaces
Maintenance Use Cable replacement and control system servicing
Identification Foxboro P0928AW model designation

Product Features

  • I/A Series 200 integration: Intended for use in compatible Foxboro control system configurations.
  • Type 5 cable configuration: Identifies the termination cable type for installation and replacement purposes.
  • LSZH construction: Uses low-smoke, zero-halogen cable materials, which can help reduce smoke and halogen-containing emissions under fire conditions.
  • Defined connection path: Supports organized signal or interface connections within an industrial control cabinet.
  • Replacement suitability: The model designation helps technicians distinguish the cable from other termination cable variants.
  • Cabinet wiring support: Can be incorporated into structured control system wiring layouts where the specified cable type is required.

Working Principle

The Foxboro P0928AW functions as a physical electrical link between compatible interfaces in an I/A Series 200 control system installation. Once connected at the designated endpoints, its conductors carry the electrical signals required by the connected equipment.

During normal operation, the cable does not process control logic or independently interpret field measurements. Instead, it maintains the connection path between system components so that signals can pass through the intended termination arrangement.

A typical connection sequence is:

Compatible control system interface → P0928AW termination cable → designated termination or connection interface

The exact endpoints depend on the installed system configuration. Correct connector matching, cable routing, and endpoint identification are therefore essential when installing or replacing the cable.


Role in an I/A Series 200 Control Architecture

Within a Foxboro I/A Series 200 architecture, termination cabling forms part of the physical connection layer between control system components. The P0928AW supports this layer where a Type 5 LSZH termination cable is specified.

Control Architecture Layer Related Function
Control and processing layer Executes control logic and handles configured process data
I/O and interface layer Exchanges signals between field connections and the control system
Termination connection layer Provides the physical cable path between designated interfaces
Cabinet wiring infrastructure Organizes and routes cables while supporting maintenance access
Field instrumentation layer Supplies process measurements or receives control commands through the relevant system interfaces

The P0928AW belongs to the termination connection layer. Its function is connectivity rather than signal conversion or control processing.


Industrial Applications

Application Use of the P0928AW
Distributed control system cabinets Connects designated interfaces in compatible Foxboro installations
Process automation systems Supports the physical signal connection arrangement used by the control system
Chemical and petrochemical facilities Can be used in compatible control cabinets where LSZH cabling is specified
Oil and gas process installations Supports termination wiring within applicable automation infrastructure
Power and utility control systems Serves as a connection cable in compatible system configurations
DCS maintenance and refurbishment Provides a model-specific option when replacing an existing termination cable
Industrial control cabinet upgrades Supports wiring changes where the specified Type 5 cable arrangement is retained

Installation and Maintenance

  1. Verify the model: Confirm that P0928AW matches the cable specified for the intended Foxboro I/A Series 200 installation.
  2. Check the connection points: Identify both endpoints before removing an existing cable or installing a replacement.
  3. Isolate equipment as required: Follow the site’s electrical safety and isolation procedures before working on control system connections.
  4. Inspect the cable: Check the cable jacket, connector areas, and accessible contact surfaces for visible damage.
  5. Confirm connector compatibility: Ensure the cable ends match the designated interfaces; do not force a connector into an incompatible socket.
  6. Label both ends: Preserve or apply identification that corresponds to the cabinet wiring drawings and maintenance records.
  7. Route the cable correctly: Keep the cable clear of sharp edges, moving parts, and sources of excessive heat.
  8. Avoid mechanical strain: Do not pull the cable by its conductors or connector body, and avoid tight bends that could damage the cable.
  9. Maintain separation: Follow cabinet wiring practices for separating signal cables from power wiring where required by the installation.
  10. Secure the cable: Use suitable cable-management hardware without crushing or excessively compressing the jacket.
  11. Verify the connection: After installation, inspect the connector seating and check the associated signal path according to the system’s maintenance procedure.
  12. Record the replacement: Update the maintenance log with the model installed and any relevant findings from the inspection.

If a connection fault occurs after replacement, check connector seating, endpoint identification, cable routing, and the condition of the associated interfaces. Confirm the intended cable assignment before attributing the fault to the cable itself.


Related Components

Component Function in the Control System
Foxboro I/A Series 200 I/O modules Interface with process signals within the configured control system
Foxboro termination assemblies Provide connection points for designated signal and system wiring
Foxboro system interface modules Support communication or signal exchange between system sections, depending on configuration
Control cabinet terminal blocks Organize electrical connections and facilitate wiring maintenance
Cable identification markers Help technicians trace and verify individual connection paths
Cabinet cable-management accessories Support organized routing and reduce mechanical strain on installed wiring

Recommended Related Models

Model Product Description Relationship
Foxboro P0928AW I/A Series 200 Type 5 LSZH Termination Cable Reference model for this cable configuration
Foxboro RH916FK I/A Series 200 Type 4 P/PVC Termination Cable Related termination cable variant; verify interface and cable-type requirements before substitution
Foxboro P0916FL I/A Series 200 Type 4 P/PVC Termination Cable Related cable model for installations specifying the corresponding Type 4 configuration
Foxboro RH916FL I/A Series 200 Type 4 P/PVC Termination Cable Related termination cable variant; not an automatic replacement for P0928AW
Foxboro P0916FM I/A Series 200 Type 4 P/PVC Termination Cable Another cable variant within the I/A Series 200 termination cable family

Key Advantages

  • Model-specific identification for maintenance and replacement work.
  • LSZH cable construction for installations requiring low-smoke, zero-halogen materials.
  • Supports organized connections within compatible Foxboro I/A Series 200 systems.
  • Suitable for control cabinet maintenance and system refurbishment when the specified cable configuration matches.
  • Helps maintain the intended physical connection path between designated interfaces.

Technical FAQs

1. What is the Foxboro P0928AW used for?

The P0928AW is an I/A Series 200 Type 5 LSZH termination cable used to connect designated interfaces in compatible Foxboro control system installations. It serves as a physical electrical connection rather than an active control or signal-processing device.

2. What does LSZH mean on the P0928AW cable?

LSZH stands for Low Smoke Zero Halogen. It describes cable materials intended to produce low smoke and no halogen-containing gases from the cable compounds under specified fire-test conditions. Actual fire performance depends on the cable’s tested construction and applicable standards.

3. Can the P0928AW replace a Type 4 P/PVC termination cable?

Not automatically. The P0928AW is identified as a Type 5 LSZH cable, while Type 4 P/PVC models belong to a different cable configuration. Before substitution, verify the required cable type, connector arrangement, endpoint assignment, and system documentation.

4. What should be checked when installing or replacing the P0928AW?

Confirm the model designation, connector compatibility, cable routing, and endpoint labels. After installation, check that the connections are fully seated and verify the associated signal path using the site’s approved maintenance procedure.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501