Product Overview The GE IC200ALG320B VersaMax Analog Output Module is an analog output module for the VersaMax PLC and distributed I/O platform. It converts controller-generated analog values into outpu……
GE IC200ALG320B VersaMax Analog Output Module
  • GE
  • IC200ALG320B
  • Analog Output Module
  • USA
  • 110 × 66.8 × 50 mm
  • 0.272 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

GE IC200ALG320B VersaMax Analog Output Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IC200ALG320B VersaMax Analog Output Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IC200ALG320B VersaMax Analog Output Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IC200ALG320B VersaMax Analog Output Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IC200ALG320B VersaMax Analog Output Module is an analog output module for the VersaMax PLC and distributed I/O platform. It converts controller-generated analog values into output signals that can be used by field devices such as control valves, variable-speed drives, actuators, and other continuously controlled equipment.

In a typical VersaMax installation, the IC200ALG320B is located on the output side of the control system. The PLC or CPU determines the required process value, and the module translates that value into the corresponding analog output for the connected field device.

This type of module is useful in applications where a simple discrete ON/OFF command is not sufficient. Flow, pressure, temperature, speed, and valve position can all require continuously adjustable control signals, making analog output hardware an important part of the control loop.

For maintenance engineers, troubleshooting should include the module, terminal connections, field wiring, controller configuration, and the connected analog device. An incorrect output can originate from configuration or wiring as well as from the module itself.


Technical Specifications

ParameterSpecification
Manufacturer GE
Model IC200ALG320B
Product Family VersaMax
Product Type Analog Output Module
Primary Function Provides analog output signals to field devices
System Role Analog output interface
Application PLC and distributed I/O control systems
Installation VersaMax I/O station
Dimensions 110 × 66.8 × 50 mm
Weight 0.272 kg

Product Features

  • Part of the GE VersaMax automation platform.
  • Provides analog output functionality for controller applications.
  • Converts internal control values into analog field outputs.
  • Suitable for continuous process control.
  • Supports applications involving valves, actuators, and other analog-controlled equipment.
  • Integrates with VersaMax PLC and distributed I/O architectures.
  • Suitable for process control loops requiring variable output commands.
  • Provides a dedicated interface between the control system and analog field devices.
  • Useful for both new installations and maintenance replacement.
  • Can be incorporated into compact distributed control cabinets.

Working Principle

The IC200ALG320B receives an output value generated by the VersaMax controller and converts the controller-side value into the corresponding analog output signal. The connected field device then uses that signal to adjust its operating point.

VersaMax CPU → IC200ALG320B Analog Output → Analog Signal → Control Valve / Drive / Actuator

For example, a controller may calculate a required valve position based on process conditions. The analog output module receives the calculated value and produces the corresponding output for the valve positioner. The field device responds continuously rather than simply switching between two states.

Typical operations include:

  • Receiving analog output commands from the controller.
  • Converting controller values into field-level analog signals.
  • Sending variable control commands to connected devices.
  • Supporting closed-loop process control.
  • Working with controller logic, configuration, and field wiring as one complete output path.

During commissioning, the engineering value, module configuration, measured output, and field-device response should be checked together.


Role in a VersaMax PLC Control Architecture

The IC200ALG320B occupies the analog output layer of a VersaMax control system. It connects controller processing with field equipment that requires a continuously variable command rather than a discrete output.

PLC / CPU → VersaMax I/O → IC200ALG320B → Analog Field Signal → Final Control Device

System ElementFunction
VersaMax CPU Executes application logic and calculates required control values
VersaMax I/O Architecture Provides the interface between controller processing and field signals
IC200ALG320B Generates analog output signals for connected equipment
Field Wiring Carries the analog output to the field device
Control Valve / Actuator Converts the analog command into physical movement
Process Equipment Responds to the controlled variable
Engineering System Supports configuration, monitoring, and troubleshooting

The module therefore forms the output portion of a continuous control loop and works together with the controller and final control element.


Industrial Applications

ApplicationTypical Use
Process Control Variable output commands for process equipment
Valve Control Continuous positioning of control valves
Flow Regulation Analog command to flow-control equipment
Pressure Control Output signal for pressure-regulating devices
Temperature Control Analog control of heating or cooling equipment
Motor Speed Control Variable reference signal for compatible drives
Water and Wastewater Continuous control of pumps, valves, and treatment equipment
Manufacturing Automation Analog commands for industrial actuators and machinery

Installation and Maintenance

  1. Verify the IC200ALG320B model before installation or replacement.
  2. Confirm that the module is suitable for the existing VersaMax system configuration.
  3. Isolate the relevant control equipment before handling the module or field wiring.
  4. Check the I/O station and module seating before commissioning.
  5. Inspect terminal connections for looseness, corrosion, or damaged conductors.
  6. Verify field wiring against the approved control-system documentation.
  7. Confirm that the controller configuration matches the installed analog output arrangement.
  8. Check the connected field device before assuming that an abnormal output originates from the module.
  9. Measure the actual output during commissioning when appropriate test procedures are available.
  10. Compare the commanded output value with the measured field signal.
  11. Investigate grounding, wiring, configuration, and field-device conditions when output behavior is abnormal.
  12. Perform a functional test of the complete control loop after replacement.

For troubleshooting, the complete path from the VersaMax controller to the final control device should be checked. A module replacement alone may not correct an issue caused by incorrect scaling, field wiring, configuration, or a defective actuator.


Related Components

ComponentFunction
VersaMax CPU Executes control application logic
VersaMax I/O Carrier / Station Hardware Provides the module installation and system interconnection
Analog Input Modules Acquire continuous process measurements
Discrete I/O Modules Handle digital field signals
Power Supply Provides operating power for the control system
Control Valves Receive analog positioning commands
Variable-Speed Drives Receive compatible analog reference signals
Engineering Software Supports configuration and diagnostics

Recommended Related Models

Model / Product FamilyProduct TypeTypical Application
GE IC200ALG320B VersaMax Analog Output Module Analog process output
GE VersaMax Analog Input Modules Analog Input Temperature, pressure, flow, and other measurements
GE VersaMax Discrete Input Modules Digital Input Field status and switch monitoring
GE VersaMax Discrete Output Modules Digital Output Solenoids, relays, and discrete actuators
GE VersaMax CPU Modules PLC Processor Application logic and controller processing
GE VersaMax Power Supply Modules Power Supply VersaMax system power

Key Advantages

  • Provides analog output capability within the VersaMax platform.
  • Suitable for continuous rather than simple discrete control.
  • Connects PLC calculations with analog field equipment.
  • Supports applications involving valves, drives, and actuators.
  • Fits into VersaMax distributed I/O architectures.
  • Useful for process control and industrial machine applications.

Technical FAQs

What is the primary purpose of the GE IC200ALG320B?

The IC200ALG320B is a VersaMax Analog Output Module. It provides analog output signals generated from controller commands for connected field devices requiring variable control signals.

What types of equipment can use an analog output from the IC200ALG320B?

Typical applications include control valves, actuators, compatible variable-speed drives, and other equipment that accepts an analog reference or command signal. The exact field device must match the module’s configured output requirements.

Why should the controller configuration be checked when troubleshooting an analog output?

An abnormal analog signal can result from incorrect configuration or scaling even when the physical module is operating normally. The commanded value, configuration, wiring, measured output, and field-device response should therefore be compared during troubleshooting.

What should be checked after replacing the IC200ALG320B?

Verify module installation, terminal wiring, controller configuration, output behavior, and the response of the connected field device. A complete loop test is preferable to checking the module alone.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501