Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The GE IC200ALG320B VersaMax Analog Output Module is an analog output module for the VersaMax PLC and distributed I/O platform. It converts controller-generated analog values into output signals that can be used by field devices such as control valves, variable-speed drives, actuators, and other continuously controlled equipment.
In a typical VersaMax installation, the IC200ALG320B is located on the output side of the control system. The PLC or CPU determines the required process value, and the module translates that value into the corresponding analog output for the connected field device.
This type of module is useful in applications where a simple discrete ON/OFF command is not sufficient. Flow, pressure, temperature, speed, and valve position can all require continuously adjustable control signals, making analog output hardware an important part of the control loop.
For maintenance engineers, troubleshooting should include the module, terminal connections, field wiring, controller configuration, and the connected analog device. An incorrect output can originate from configuration or wiring as well as from the module itself.
| ParameterSpecification | |
|---|---|
| Manufacturer | GE |
| Model | IC200ALG320B |
| Product Family | VersaMax |
| Product Type | Analog Output Module |
| Primary Function | Provides analog output signals to field devices |
| System Role | Analog output interface |
| Application | PLC and distributed I/O control systems |
| Installation | VersaMax I/O station |
| Dimensions | 110 × 66.8 × 50 mm |
| Weight | 0.272 kg |
The IC200ALG320B receives an output value generated by the VersaMax controller and converts the controller-side value into the corresponding analog output signal. The connected field device then uses that signal to adjust its operating point.
VersaMax CPU → IC200ALG320B Analog Output → Analog Signal → Control Valve / Drive / Actuator
For example, a controller may calculate a required valve position based on process conditions. The analog output module receives the calculated value and produces the corresponding output for the valve positioner. The field device responds continuously rather than simply switching between two states.
Typical operations include:
During commissioning, the engineering value, module configuration, measured output, and field-device response should be checked together.
The IC200ALG320B occupies the analog output layer of a VersaMax control system. It connects controller processing with field equipment that requires a continuously variable command rather than a discrete output.
PLC / CPU → VersaMax I/O → IC200ALG320B → Analog Field Signal → Final Control Device
| System ElementFunction | |
|---|---|
| VersaMax CPU | Executes application logic and calculates required control values |
| VersaMax I/O Architecture | Provides the interface between controller processing and field signals |
| IC200ALG320B | Generates analog output signals for connected equipment |
| Field Wiring | Carries the analog output to the field device |
| Control Valve / Actuator | Converts the analog command into physical movement |
| Process Equipment | Responds to the controlled variable |
| Engineering System | Supports configuration, monitoring, and troubleshooting |
The module therefore forms the output portion of a continuous control loop and works together with the controller and final control element.
| ApplicationTypical Use | |
|---|---|
| Process Control | Variable output commands for process equipment |
| Valve Control | Continuous positioning of control valves |
| Flow Regulation | Analog command to flow-control equipment |
| Pressure Control | Output signal for pressure-regulating devices |
| Temperature Control | Analog control of heating or cooling equipment |
| Motor Speed Control | Variable reference signal for compatible drives |
| Water and Wastewater | Continuous control of pumps, valves, and treatment equipment |
| Manufacturing Automation | Analog commands for industrial actuators and machinery |
For troubleshooting, the complete path from the VersaMax controller to the final control device should be checked. A module replacement alone may not correct an issue caused by incorrect scaling, field wiring, configuration, or a defective actuator.
| ComponentFunction | |
|---|---|
| VersaMax CPU | Executes control application logic |
| VersaMax I/O Carrier / Station Hardware | Provides the module installation and system interconnection |
| Analog Input Modules | Acquire continuous process measurements |
| Discrete I/O Modules | Handle digital field signals |
| Power Supply | Provides operating power for the control system |
| Control Valves | Receive analog positioning commands |
| Variable-Speed Drives | Receive compatible analog reference signals |
| Engineering Software | Supports configuration and diagnostics |
| Model / Product FamilyProduct TypeTypical Application | ||
|---|---|---|
| GE IC200ALG320B | VersaMax Analog Output Module | Analog process output |
| GE VersaMax Analog Input Modules | Analog Input | Temperature, pressure, flow, and other measurements |
| GE VersaMax Discrete Input Modules | Digital Input | Field status and switch monitoring |
| GE VersaMax Discrete Output Modules | Digital Output | Solenoids, relays, and discrete actuators |
| GE VersaMax CPU Modules | PLC Processor | Application logic and controller processing |
| GE VersaMax Power Supply Modules | Power Supply | VersaMax system power |
The IC200ALG320B is a VersaMax Analog Output Module. It provides analog output signals generated from controller commands for connected field devices requiring variable control signals.
Typical applications include control valves, actuators, compatible variable-speed drives, and other equipment that accepts an analog reference or command signal. The exact field device must match the module’s configured output requirements.
An abnormal analog signal can result from incorrect configuration or scaling even when the physical module is operating normally. The commanded value, configuration, wiring, measured output, and field-device response should therefore be compared during troubleshooting.
Verify module installation, terminal wiring, controller configuration, output behavior, and the response of the connected field device. A complete loop test is preferable to checking the module alone.