The ICS Triplex T8111C Trusted TMR Processor Module is a processor module for the Trusted safety system, using a Triple Modular Redundancy (TMR) architecture to support high-integrity control and safety applications.
Within a Trusted system, the processor handles the execution of application logic, system sequencing, diagnostics, and coordination with the associated I/O architecture. The TMR arrangement uses three processor channels operating together, allowing the system to compare processor results and maintain operation in the presence of certain single-channel faults.
The T8111C is suited to applications where the controller must continuously manage safety-related logic while maintaining extensive diagnostic coverage. Typical installations include process plants, emergency shutdown systems, turbine control, and other industrial applications where controller availability and fault detection are key system requirements.
| Parameter | Specification |
|---|---|
| Manufacturer | ICS Triplex |
| Model | T8111C |
| Product Family | Trusted |
| Product Type | Trusted TMR Processor Module |
| Primary Function | Safety System Processing |
| Processor Architecture | Triple Modular Redundancy (TMR) |
| System Role | Trusted System Processor |
| Application | Safety / Industrial Control Systems |
| Installation | Trusted System Architecture |
| Dimensions | 303 × 93 × 266 mm |
| Weight | 1.89 kg |
The T8111C processes the application running in the Trusted controller and coordinates the system’s interaction with its I/O modules.
The TMR architecture can be viewed as three processor channels working together:
Processor Channel A + Processor Channel B + Processor Channel C → TMR Decision / System Output
Each processor channel independently performs the applicable processing. The results are compared so that discrepancies between channels can be detected. Where a single processor channel develops a fault, the redundant architecture allows the system to identify the abnormal result without relying solely on that channel.
A typical control path is:
Field Inputs → Trusted I/O → T8111C TMR Processor → Application Logic → Trusted Outputs → Field Equipment
This architecture allows processor operation, diagnostics, and field control to remain integrated within the Trusted safety system.
| System Element | Function |
|---|---|
| T8111C | Executes Trusted application and safety processing |
| Trusted I/O Modules | Acquire field inputs and deliver output commands |
| Trusted Interface Modules | Provide system interconnections |
| Trusted Power Components | Supply system power |
| Engineering / Configuration System | Handles application configuration |
| Field Sensors | Provide process information |
| Field Actuators | Execute control or shutdown actions |
| Operator / Supervisory System | Provides monitoring and system interaction |
The T8111C occupies the central processing layer between the Trusted I/O subsystem and the application-level control functions.
| Application | Typical Use |
|---|---|
| Emergency Shutdown Systems | Safety logic execution |
| Oil and Gas | Process and shutdown control |
| Chemical Processing | Safety-related process functions |
| Power Generation | Turbine and plant protection |
| Process Plants | High-integrity control |
| Refining | Safety instrumented applications |
| Industrial Automation | Redundant control architectures |
| Critical Process Systems | Fault-tolerant processing |
For a processor fault, diagnostics should be reviewed before replacing hardware. A TMR system can report channel-specific faults, so identifying the affected channel can help avoid unnecessary replacement of healthy components.
| Component | Function |
|---|---|
| ICS Triplex T8111C | Trusted TMR Processor Module |
| T8122C | Trusted Processor Interface Adapter |
| T8290C | Trusted Output Power Distribution Unit |
| Trusted I/O Modules | Field signal acquisition and output |
| Trusted Interface Hardware | System interconnection |
| Trusted Power Supply | System power |
| Trusted Chassis | Processor and system-module installation |
| Field Sensors | Process input signals |
| Field Actuators | Safety and control outputs |
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| ICS Triplex T8111C | Trusted TMR Processor Module | Redundant safety processing |
| ICS Triplex T8122C | Trusted Processor Interface Adapter | Processor-side interfacing |
| ICS Triplex T8290C | Trusted Output Power Distribution Unit | Output power distribution |
| ICS Triplex Trusted I/O Modules | I/O Module Family | Field signal processing |
| ICS Triplex Trusted Controller | Safety Controller | Safety and process logic |
| ICS Triplex Trusted Interface Modules | Interface Module Family | System interconnection |
| ICS Triplex Trusted Power Supply | Power Supply | System power |
| ICS Triplex Trusted Chassis | System Chassis | Trusted hardware installation |
TMR uses three redundant processor channels so that their processing results can be compared. This architecture helps the Trusted system detect certain processor-channel faults while maintaining the required system response.
A channel-level fault affects one redundant processing path, while a complete processor-system failure would involve loss of the overall processing function. TMR architecture specifically helps isolate and manage certain single-channel faults.
The diagnostic information should first be reviewed to identify the affected channel and fault condition. Associated interfaces, power, connections, and neighboring Trusted modules should then be checked before deciding whether the processor module requires replacement.
No. It operates as part of the broader Trusted architecture. The processor works together with Trusted I/O, interface, power, and field equipment to execute the complete safety and control application.