The Triconex® 3601T is a high-integrity digital output module designed for the Tricon™ fault-tolerant safety system. It provides 16 channels of solid-state DC outputs, each capable of switching loads up to 0.5 A. Built to meet IEC 61508 SIL 3 requirements, the 3601T ensures deterministic, fail-safe operation by continuously monitoring internal diagnostics and cross-channel voting to detect and isolate faults without compromising critical shutdown functions.
Emergency Shutdown (ESD): Driving safety shutdown valves and solenoids in oil & gas, chemical, and power facilities.
Safety Interlocks: Controlling contactors and motor starters for hazardous-area equipment.
Fire & Gas Systems: Activating alarms, fans, and fire suppression systems upon detection of dangerous conditions.
Critical Sequence Control: Enforcing safe startup and shutdown sequences in batch and continuous processes.
Redundant Safety Loops: Providing dual or triple-channel outputs in complex SIS architectures.
Brand: Triconex
Triconex pioneered fault-tolerant control systems, delivering the first triple-modular redundant (“TMR”) architecture for absolute reliability and safety. Today, Tricon™ systems protect the world’s most critical processes with certified SIL 3/SIL 4 solutions.
Triple-Modular Redundancy: Three-channel architecture with majority-voting eliminates single-point failures.
Continuous Diagnostics: Background self-tests and output monitoring detect stuck outputs, open circuits, and transistor failures.
Fail-Safe Design: On any detected fault, non-voted outputs transition to a predefined safe state.
Deterministic Response: Guaranteed <10 ms response time ensures prompt activation of safety functions.
Robust Construction: Conformal-coated PCBs, wide temperature range, and EMI-hardened components for harsh industrial environments.
Specification | Details |
---|---|
Model Number | 3601T |
Function | 16-channel DC solid-state output |
Output Rating | 24 V DC @ 0.5 A per channel |
Number of Channels | 16 |
Isolation | 2.5 kV AC channel-to-channel and to backplane |
Response Time | < 10 ms |
Diagnostics | Open-load detect, short-circuit detect, self-test |
Operating Temperature | –40 °C to +70 °C |
Storage Temperature | –40 °C to +85 °C |
Relative Humidity | 5 % to 95 % RH (non-condensing) |
Dimensions (W × H × D) | 200 × 150 × 50 mm |
Weight | 1.2 kg |
Mounting | Tricon™ 3000 I/O rack slot |
Model | Function |
---|---|
3602T | 16-channel AC output module |
3611T | 16-channel sink/source DC input module |
3621S | 8-channel relay output module |
3625A | 32-channel discrete input module |
3641T | 8-channel analog output module |
Model | Description |
---|---|
3672T | High-speed digital input module |
3692S | SIL 3 analog input module |
3642A | 16-channel isolated ac input module |
3624T | 8-channel high-integrity relay output |
3680T | Temperature transmitter interface module |
Q: What load types can the 3601T drive?
A: It switches 24 V DC loads up to 0.5 A per channel, such as solenoid valves or contactor coils.
Q: How does the module detect output faults?
A: Continuous diagnostics monitor each transistor for open-load and short-circuit conditions.
Q: What happens on a channel failure?
A: The faulty channel transitions to its safe state; majority voting ensures overall system safety.
Q: Is the 3601T hot-swappable?
A: Yes—when installed in a redundant rack, modules can be replaced without shutting down the system.
Q: How fast does it respond to a safety command?
A: It guarantees output switching within 10 ms of a validated safety input.
Q: What environmental conditions does it support?
A: Operating range –40 °C to +70 °C, 5 %–95 % RH non-condensing, EMI-shielded design.
Q: Can it be used in SIL 4 applications?
A: While certified SIL 3, the Tricon™ TMR architecture can achieve SIL 4 system performance.
Q: What backplane slot does it occupy?
A: It fits into one Tricon™ 3000 I/O rack slot with standard width.
Q: How is module health reported?
A: Status LEDs and Tricon™ diagnostics over the bus provide real-time health information.
Q: Does it support mixed output types?
A: For AC outputs or relay outputs, use related modules like 3602T or 3621T in the same rack.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.