Product Overview The Schneider Electric NW32N2 MasterPact NW Circuit Breaker is a low-voltage air circuit breaker designed for high-capacity power distribution and electrical protection in industrial an……
Schneider NW32N2 Circuit Breaker
  • Schneider
  • NW32N2
  • Circuit Breaker
  • France
  • 439 x 441 x 395 mm
  • 131 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

Schneider NW32N2 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW32N2 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW32N2 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW32N2 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW32N2 MasterPact NW Circuit Breaker is a low-voltage air circuit breaker designed for high-capacity power distribution and electrical protection in industrial and commercial installations. It belongs to the MasterPact NW family, a range developed for applications requiring reliable switching, overload protection, short-circuit interruption, and coordination within low-voltage electrical distribution systems.

Air circuit breakers are commonly installed in main distribution boards, switchboards, industrial power centers, and large electrical panels. They protect electrical circuits by detecting abnormal current conditions and interrupting the power supply when the configured protection thresholds are exceeded.

The NW32 designation identifies a 3200 A frame class within the MasterPact NW product family. The complete electrical characteristics of an NW32N2 assembly depend on its exact catalog configuration, including the trip unit, pole arrangement, mounting style, and installed accessories. Therefore, the abbreviated model designation should be checked against the product nameplate before selecting a replacement or preparing an installation.

The MasterPact NW platform supports different circuit-breaker arrangements, including fixed and drawout configurations. Drawout designs are particularly useful in industrial distribution systems where maintenance and replacement procedures need to be performed without removing the entire switchgear assembly.

The NW32N2 is intended for applications where high-current power distribution requires coordinated protection and controlled switching. Its suitability must be assessed according to the installation’s voltage, prospective short-circuit current, load characteristics, protection coordination requirements, and applicable electrical standards.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family MasterPact NW
Model NW32N2
Product Type Air Circuit Breaker
Circuit Breaker Category Low-Voltage Power Circuit Breaker
Frame Class NW32
Frame Current Class 3200 A
Protection Function Overload and short-circuit protection, depending on trip-unit configuration
Mounting Options Fixed or drawout, depending on the complete configuration
Pole Configuration Must be verified from the complete product designation
Trip Unit Configuration-dependent
Rated Operational Voltage Verify from the nameplate and applicable product documentation
Ultimate Breaking Capacity Configuration-dependent
Rated Short-Time Withstand Current Configuration-dependent
Dimensions Provided 439 × 441 × 395 mm
Weight Provided 131 kg
Product Family MasterPact NW

Important: NW32N2 is an abbreviated identification. Do not assume that all MasterPact NW32 models have identical breaking capacity, trip-unit functions, pole configuration, or accessories. Confirm the complete catalog number and nameplate before ordering.

Function and Working Principle

The MasterPact NW32N2 is designed to protect high-current electrical distribution circuits by monitoring current conditions and interrupting the circuit when an abnormal operating condition is detected.

1. Overload Protection

An overload occurs when a circuit carries more current than its permitted operating level for a sustained period. Excessive current can cause conductors, busbars, and connected equipment to overheat.

An appropriately configured electronic trip unit monitors the current and applies the selected protection settings. If the overload condition exceeds the permitted threshold and delay, the circuit breaker trips and disconnects the protected circuit.

For a 3200 A frame-class installation, protection settings must be selected according to the actual conductor capacity, downstream equipment, transformer characteristics, and system coordination requirements.

2. Short-Circuit Protection

A short circuit can produce a sudden and very high current. Without suitable protection, this fault current can create severe thermal and mechanical stress on electrical equipment.

The circuit breaker’s protection system detects the fault condition and initiates interruption. Its breaking capacity must be sufficient for the prospective short-circuit current at the installation point.

The exact breaking capacity of an NW32N2 assembly must be confirmed from its complete configuration. The NW32 frame designation alone is not sufficient to determine the applicable kA rating.

3. Electronic Trip Functions

MasterPact NW circuit breakers can be configured with electronic trip units that provide adjustable protection functions. Depending on the installed trip-unit type, these functions may include:

  • Long-time protection for sustained overload conditions.
  • Short-time protection for time-delayed short-circuit coordination.
  • Instantaneous protection for high-magnitude fault currents.
  • Ground-fault protection where supported by the selected configuration.
  • Current measurement and fault indication functions on compatible trip units.

These functions allow engineers to coordinate the main circuit breaker with downstream protective devices. The actual available functions and settings depend on the installed trip unit.

4. Switching and Isolation

An air circuit breaker also provides controlled switching of electrical distribution circuits. Depending on its arrangement and accessories, it can be operated locally or through an electrical operating mechanism.

This capability is important in main distribution systems where operators need to isolate equipment for maintenance, control power distribution, or respond to abnormal operating conditions.

Circuit-breaker switching must follow the approved operating procedures and electrical safety requirements of the installation.

5. Arc Interruption

When a circuit breaker opens under load or fault conditions, an electrical arc may form between the separating contacts. The arc-interruption system is designed to extinguish this arc and safely interrupt the current.

Air circuit breakers use an arc-control arrangement to manage and extinguish the arc during interruption. The interruption performance depends on the circuit-breaker design and its rated electrical characteristics.

Role in Industrial Power Distribution Systems

The NW32N2 can serve as a major protection and switching device in a low-voltage power distribution installation.

Main Incoming Protection

In large industrial facilities, the main incoming circuit breaker protects the distribution system supplied by a transformer or other power source.

A suitably selected MasterPact NW circuit breaker can provide the required protection and isolation functions at the incoming distribution point. Its frame class makes it relevant to high-current systems, subject to verification of the complete electrical ratings.

Busbar Protection and Distribution

Industrial switchboards often use busbar systems to distribute electrical power to multiple outgoing feeders. A main air circuit breaker can protect the associated distribution section and provide a controlled means of disconnecting the supply.

Correct protection coordination is important to prevent a fault on one outgoing circuit from unnecessarily interrupting the entire distribution system.

Integration with Protection Systems

The circuit breaker may be integrated into a wider electrical protection and monitoring architecture. Depending on its trip unit and accessories, it may provide status information, fault indication, and measurement data to supervisory systems.

Engineers should verify the actual auxiliary contacts, communication accessories, and trip-unit functions fitted to the individual breaker.

Coordination with Downstream Devices

The main circuit breaker should be coordinated with downstream breakers, fuses, motor protection devices, and other protective equipment.

Appropriate coordination helps ensure that a fault is isolated as close as practical to its source, reducing unnecessary interruptions to unaffected sections of the facility.

Industrial Applications

The MasterPact NW32N2 is intended for high-current power distribution environments where circuit protection and switching are essential.

1. Industrial Main Distribution Boards

Large manufacturing plants use main distribution boards to receive and distribute electrical power to production areas, utilities, and auxiliary systems.

A suitably configured NW32 circuit breaker can serve as a main protective device in a distribution assembly, provided its rated current and fault-interruption capability match the system design.

2. Transformer Secondary Protection

Transformers supplying industrial low-voltage distribution systems require suitable protection on their secondary side.

A properly selected air circuit breaker can provide overload and short-circuit protection for the downstream distribution system. Selection must account for transformer capacity, impedance, prospective fault current, and coordination with upstream protection.

3. Power Distribution Centers

Industrial power distribution centers supply multiple feeders to production lines, motors, lighting systems, and auxiliary loads.

A MasterPact NW circuit breaker can be used as a main switching and protection device within a suitable low-voltage switchboard.

4. Manufacturing Facilities

Automotive, chemical, metal-processing, food-production, and other manufacturing facilities often operate large electrical distribution systems.

High-capacity circuit breakers help protect these systems against abnormal current conditions and provide a means of isolating distribution sections for maintenance.

5. Infrastructure and Utility Installations

Large infrastructure facilities may require high-current circuit protection in electrical rooms, central distribution systems, and power-management installations.

The suitability of the NW32N2 depends on the system voltage, fault level, operating environment, and protection requirements.

6. Commercial and Industrial Buildings

Large commercial complexes, data centers, and industrial buildings require dependable electrical distribution to support critical equipment.

A suitably rated MasterPact NW circuit breaker may be used in main switchboards where the required electrical characteristics and protection coordination are satisfied.

Installation and System Integration

Installing a high-current air circuit breaker requires careful planning, qualified electrical personnel, and compliance with the manufacturer’s instructions.

1. Verify the Complete Model Configuration

Before installation, inspect the product nameplate and confirm the complete catalog number.

Check the following details:

  • Rated current and frame rating.
  • Rated operational voltage.
  • Number of poles.
  • Ultimate and service breaking capacities.
  • Short-time withstand current.
  • Trip-unit model and protection functions.
  • Fixed or drawout mounting arrangement.
  • Electrical operating accessories.
  • Auxiliary contacts and communication options.

The NW32N2 abbreviated designation does not provide enough information to establish all these characteristics.

2. Confirm Panel Dimensions and Mounting

The supplied dimensions are 439 × 441 × 395 mm.

These dimensions are consistent with a MasterPact NW32 three-pole drawout dimensional arrangement. However, the complete switchgear assembly may require additional space for the cradle, busbar connections, operating mechanism, cable access, and maintenance clearance.

Before panel fabrication or replacement, compare the actual circuit breaker with the manufacturer’s dimensional drawings.

3. Busbar and Electrical Connections

The electrical connections must be suitable for the rated current and the prospective fault level of the installation.

Check busbar dimensions, connection orientation, terminal condition, insulation clearances, and mechanical support. Connection arrangements may differ between fixed and drawout versions.

All electrical connections must be installed and tightened according to the manufacturer’s specified procedures and torque requirements.

4. Protection Setting and Coordination

Configure the trip unit according to the protection study and system design.

Protection settings should account for:

  • Transformer and generator characteristics.
  • Cable and busbar current capacity.
  • Downstream circuit-breaker settings.
  • Expected load current.
  • Prospective short-circuit current.
  • Required selectivity and backup protection.

Do not copy protection settings from another breaker without confirming that the electrical system and equipment configuration are equivalent.

5. Auxiliary Circuit Integration

Depending on the installed accessories, the circuit breaker may provide auxiliary contacts, electrical operating functions, trip indication, and other status signals.

These signals can be connected to a PLC, power-management system, or supervisory control system when the appropriate accessories are installed.

Verify the terminal diagram and accessory compatibility before connecting control wiring.

6. Commissioning and Functional Testing

Before energizing the installation, qualified personnel should inspect the mechanical and electrical condition of the breaker.

Commissioning should include checks of:

  • Main contact condition and connection integrity.
  • Mechanical opening and closing operation.
  • Drawout racking mechanism, where applicable.
  • Trip-unit settings and protection functions.
  • Auxiliary contact operation.
  • Electrical operating accessories.
  • Insulation and grounding arrangements.
  • Coordination with upstream and downstream protection.

Testing procedures should follow the manufacturer’s documentation and applicable electrical safety standards.

Compatible System Components

A MasterPact NW32 circuit breaker is normally installed as part of a complete low-voltage distribution system.

Component Function Compatibility Considerations
MasterPact NW cradle Supports a drawout breaker Must match the breaker frame, pole arrangement, and mounting configuration
Micrologic trip unit Provides electronic protection Confirm exact trip-unit type and supported functions
Electrical operating mechanism Enables remote or motorized operation Verify voltage and accessory compatibility
Shunt trip release Provides remote opening capability Match the release coil voltage and breaker configuration
Undervoltage release Trips or prevents closing under specified voltage conditions Confirm the correct accessory and supply rating
Auxiliary contacts Provide breaker status signals Verify contact arrangement and terminal assignments
Communication accessories Support remote monitoring where configured Confirm compatibility with the trip unit and communication architecture
Busbar system Carries electrical current through the switchboard Verify current rating, connection dimensions, and fault withstand capability
PLC or power-management system Monitors and coordinates electrical equipment Requires compatible contacts, communication accessories, and interface design

Not every component listed above is included with the NW32N2. The installed accessories must be checked against the actual unit.

Alternative Models and Replacement Considerations

When replacing a MasterPact NW32N2, the replacement should be selected according to electrical ratings and physical configuration rather than frame designation alone.

Alternative or Related Product Replacement Considerations
Another MasterPact NW32 circuit breaker May be suitable if voltage, breaking capacity, pole configuration, trip unit, and mounting arrangement match
MasterPact NW25 A smaller frame class; not a direct substitute without verifying system current and protection requirements
MasterPact NW40 A larger frame class that may be considered for redesigned installations, subject to system and switchgear compatibility
Current-generation MasterPact circuit breaker May be suitable for modernization, but dimensions, cradle, accessories, and protection coordination must be reviewed
Schneider Electric EasyPact NW range A related power-distribution product family; verify ratings and physical compatibility before considering replacement

Before selecting a replacement, engineers should compare:

  • Rated operational voltage.
  • Rated current and frame size.
  • Ultimate and service breaking capacities.
  • Short-time withstand current.
  • Pole configuration.
  • Trip-unit type and protection functions.
  • Fixed or drawout mounting.
  • Cradle and busbar compatibility.
  • Auxiliary and communication accessories.
  • Switchboard dimensions and connection arrangements.

A replacement circuit breaker should not be installed solely because its frame rating is similar. The complete electrical and mechanical configuration must be validated.

Key Advantages

High-Current Distribution Capability

The NW32 frame class is designed for high-current low-voltage distribution applications, with a 3200 A frame rating.

Comprehensive Circuit Protection

When equipped with the appropriate trip unit, the MasterPact NW platform can provide protection against overloads and short circuits, with additional functions depending on configuration.

Industrial Switching Capability

The circuit breaker provides a means of switching and isolating high-current distribution circuits in industrial electrical systems.

Configurable Installation Arrangements

The MasterPact NW family includes different mounting and connection arrangements, allowing engineers to select configurations suitable for specific switchboard designs.

Integration with Electrical Monitoring

With compatible trip units and accessories, the breaker can provide status and protection information for integration into power-management systems.

Maintenance-Oriented Design

Drawout configurations allow the breaker to be withdrawn from its cradle for inspection or replacement, subject to the correct operating and safety procedures.

Established Schneider Electric Platform

The MasterPact NW family is used in industrial and commercial power distribution applications, making accurate model identification important for maintenance and spare-parts procurement.

Technical FAQs

1. What is the Schneider Electric NW32N2?

The NW32N2 is identified as a MasterPact NW air circuit breaker in the NW32 frame class. It is intended for high-current low-voltage power distribution and circuit protection.

2. What does NW32 mean?

NW32 identifies the 3200 A frame class within the MasterPact NW family. The actual rated current and protection configuration must still be checked against the complete product designation and nameplate.

3. What is the rated current of the NW32N2?

The NW32 frame class is associated with a 3200 A rating. The actual installed trip-unit and sensor configuration should be checked before applying protection settings or selecting the breaker for a specific circuit.

4. What is the breaking capacity of this circuit breaker?

The exact breaking capacity cannot be reliably established from the abbreviated NW32N2 designation alone. It depends on the specific MasterPact NW version and its rated operating voltage. Confirm the kA rating on the nameplate and technical documentation.

5. Is the NW32N2 a fixed or drawout circuit breaker?

The complete mounting arrangement must be verified. MasterPact NW products are available in fixed and drawout configurations, and their dimensions and accessories may differ.

6. Can the NW32N2 be integrated with a PLC?

Yes, where the breaker is equipped with suitable auxiliary contacts, communication accessories, or compatible trip-unit interfaces. The actual integration method depends on the installed hardware and control-system design.

7. What is the purpose of the electronic trip unit?

The electronic trip unit monitors electrical current and initiates circuit interruption when configured protection thresholds are exceeded. Depending on the model, it may support long-time, short-time, instantaneous, and ground-fault protection functions.

8. What should be checked before purchasing a replacement?

Verify the full catalog number, rated current, voltage, breaking capacity, pole arrangement, trip unit, mounting configuration, and accessories. Also inspect the nameplate and physical condition of the equipment.

9. Why does the supplied weight differ from some published NW32 product weights?

The supplied 131 kg may refer to a different pole arrangement, accessory configuration, packaging basis, or complete assembly. Published NW32 examples show different weights for three-pole and four-pole drawout versions. Confirm whether the listing weight represents the breaker alone, a complete assembly, or shipping weight.

10. Is the NW32N2 suitable for every 3200 A application?

No. Frame current alone does not establish suitability. The rated voltage, breaking capacity, short-time withstand capability, trip-unit functions, system fault level, and protection coordination must all meet the installation requirements.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric NW32N2, begin by confirming the complete model information and the breaker nameplate. The abbreviated designation should not be used as the only basis for selecting a replacement.

For new, surplus, or refurbished equipment, request clear photographs of the nameplate, front panel, rear connections, operating mechanism, and any installed trip unit. Confirm whether the breaker is fixed or drawout and whether the required cradle and accessories are included.

The supplied dimensions of 439 × 441 × 395 mm and weight of 131 kg should be treated as listing data until verified against the actual product. For international shipments, distinguish between net equipment weight and gross shipping weight.

Maintenance should follow the manufacturer’s procedures and the facility’s electrical maintenance program. Inspection may include contact wear, insulation condition, mechanical operation, connection tightness, trip-unit operation, and auxiliary circuit functionality.

Protection settings should be documented and reviewed whenever the electrical distribution system changes. Any modification to transformer capacity, feeder arrangement, or downstream equipment may affect protection coordination.

Because the NW32 is a high-current circuit breaker, installation, testing, and maintenance must be performed by qualified personnel using appropriate isolation procedures and electrical safety controls.

Conclusion

The Schneider Electric NW32N2 MasterPact NW Air Circuit Breaker is a high-current low-voltage protection and switching device associated with the 3200 A NW32 frame class. It is designed for industrial and commercial power distribution systems where overload protection, short-circuit interruption, and controlled electrical isolation are essential.

Its actual performance depends on the complete breaker configuration, including the trip unit, pole arrangement, mounting style, and accessories. Accurate nameplate verification is therefore essential when purchasing, installing, or replacing this equipment.

For maintenance and spare-parts procurement, confirm the electrical ratings, physical arrangement, connection details, and installed accessories before selecting the NW32N2 or an alternative circuit breaker.