Product Overview The Schneider MT10N2 Circuit Breaker is an industrial low-voltage circuit protection device associated with the Schneider Masterpact MT circuit breaker range. Masterpact circuit breaker……
Schneider MT10N2 Circuit Breaker
  • Schneider
  • MT10N2
  • Circuit Breaker
  • France
  • 301 x 196 x 276 mm
  • 14 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Schneider MT10N2 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MT10N2 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MT10N2 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MT10N2 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider MT10N2 Circuit Breaker is an industrial low-voltage circuit protection device associated with the Schneider Masterpact MT circuit breaker range. Masterpact circuit breakers are designed for electrical distribution systems where reliable switching, overload protection, and short-circuit protection are essential to maintaining power system safety and operational continuity.

Circuit breakers are important components in industrial power distribution networks. They monitor electrical current and interrupt the circuit when an abnormal condition exceeds the protection settings. By isolating faulty sections, they help limit damage to cables, switchgear, transformers, motors, and other connected equipment.

The MT10N2 designation is associated with a 1000 A frame rating in available Masterpact MT product references. However, the complete electrical configuration cannot be established from this designation alone. The trip unit, pole configuration, mounting arrangement, rated operational voltage, and short-circuit breaking capacity must be confirmed from the product nameplate and original technical documentation.

In industrial installations, the selection of a circuit breaker must consider the electrical characteristics of the distribution network and the protection requirements of downstream equipment. A suitable breaker should provide sufficient continuous-current capacity, an appropriate interrupting rating, and protection settings coordinated with other protective devices.

The Schneider MT10N2 may be encountered in industrial switchboards, power distribution assemblies, and maintenance or replacement projects involving legacy Masterpact equipment. Before ordering, engineers and purchasing teams should verify the exact product configuration rather than relying only on the family designation.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Model MT10N2
Product Type Industrial Circuit Breaker
Product Family Masterpact MT
Frame Rating Reference 1000 A
Protection Function Overload and short-circuit protection, subject to installed trip unit
Switching Function Circuit switching and isolation according to configuration
Dimensions Provided 301 × 196 × 276 mm
Weight Provided 14 kg
Typical Installation Industrial low-voltage switchboard
Trip Unit Verify from actual product nameplate
Number of Poles Verify from actual product configuration
Mounting Type Verify whether fixed or withdrawable
Rated Operational Voltage Confirm from product nameplate
Rated Breaking Capacity Confirm from complete model and technical documentation
Product Condition Confirm before purchase

Important: The 1000 A figure identifies the frame rating associated with MT10N2 in available product references. It should not be treated as confirmation of the installed trip-unit rating or the permissible continuous operating current. The dimensions and weight are the supplied listing values.

Function and Working Principle

A circuit breaker provides controlled switching and automatic protection in an electrical distribution system. Under normal operating conditions, it carries current to connected loads. When an electrical fault or overload occurs, the protection mechanism initiates a trip operation to interrupt the current.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating level for a sustained period.

Excessive current can cause cables, busbars, and electrical equipment to overheat. Depending on the installed trip unit, the circuit breaker can detect overload conditions and disconnect the affected circuit.

The overload protection settings must be selected according to the conductor capacity, load characteristics, and applicable electrical standards. Incorrect settings may result in unnecessary trips or inadequate protection.

2. Short-Circuit Protection

A short circuit can produce a very high fault current within a short period. If the fault is not interrupted promptly, it may cause severe thermal and mechanical stress on electrical equipment.

The circuit breaker’s short-circuit protection function detects fault conditions and initiates interruption. Its rated breaking capacity must be appropriate for the prospective short-circuit current at the installation point.

The actual breaking capacity of an MT10N2 assembly must be verified from its complete configuration and manufacturer’s documentation.

3. Switching and Circuit Isolation

Industrial circuit breakers are also used for switching electrical circuits. Depending on the installation and breaker configuration, they can support the connection and disconnection of distribution feeders and other electrical loads.

For maintenance work, the breaker may form part of an isolation procedure. However, switching off a breaker should not be treated as a substitute for the complete electrical isolation, lockout, and voltage-verification procedures required for safe maintenance.

4. Protection Coordination

Circuit breakers often operate alongside upstream and downstream protective devices. Their settings should be coordinated so that a fault is isolated as close as possible to the affected section.

Proper coordination can help prevent unnecessary shutdowns of healthy circuits. Engineers should review time-current characteristics, fault levels, and selectivity requirements when designing or modifying a distribution system.

5. Fault Indication and Maintenance

Depending on the installed trip unit and accessories, a Masterpact breaker may provide operating status, trip indication, and other monitoring functions.

These functions can help maintenance teams identify abnormal events and determine whether inspection or corrective action is required. The actual monitoring capabilities depend on the installed configuration.

Role in Industrial Power Distribution Systems

The MT10N2 is intended for use within an engineered electrical distribution arrangement. Its role is to provide switching and protection for a circuit while helping coordinate the operation of connected electrical equipment.

Main Distribution Switchboards

In industrial facilities, large distribution switchboards receive power from transformers, generators, or utility supplies and distribute it to downstream feeders.

A suitably rated circuit breaker can protect a feeder against overload and short-circuit conditions. Its selection must consider the supply voltage, load current, available fault current, and protection coordination requirements.

Motor Control Centers

Motor control centers distribute power to multiple motor circuits and associated control equipment. A main or feeder circuit breaker can provide protection for the relevant distribution section.

The breaker must be coordinated with downstream motor protection devices, contactors, overload relays, and other protective components.

Transformer Distribution

Transformers supply power to industrial distribution networks. Circuit breakers may be installed on transformer primary or secondary circuits according to the system design.

Protection settings must account for transformer characteristics, inrush current, downstream fault levels, and the protection requirements of the connected network.

Generator and Backup Power Systems

Industrial facilities may use generators or other backup power sources to maintain operation during utility interruptions.

Circuit breakers can be used in generator distribution and transfer arrangements. Their ratings and protection settings must be suitable for the source characteristics and the available short-circuit current.

Industrial Automation Power Systems

Automation facilities contain PLC systems, drives, control cabinets, instrumentation, and production machinery. A properly designed power distribution system helps protect these loads and maintain the availability of essential equipment.

The MT10N2 can be considered within an appropriate distribution arrangement, provided that its complete electrical configuration matches the installation requirements.

Industrial Applications

1. Manufacturing Plants

Manufacturing facilities use large electrical distribution networks to supply production lines, machine tools, conveyors, pumps, and auxiliary systems.

Circuit breakers provide protection for incoming supplies and distribution feeders. Their operation helps isolate electrical faults and limit disruption to other sections of the plant.

2. Power Distribution Rooms

Industrial power distribution rooms contain switchboards, busbar assemblies, protective devices, and metering equipment.

A Masterpact circuit breaker can be used in an appropriately designed low-voltage switchboard where its voltage, current, interrupting capacity, and mounting configuration meet the system requirements.

3. Chemical and Process Industries

Chemical plants and process facilities rely on continuous power for pumps, compressors, control systems, and production equipment.

Electrical protection is important because unexpected faults can affect process stability and equipment availability. Circuit breakers should be selected and coordinated according to the facility’s electrical protection study.

4. Water Treatment Facilities

Water treatment plants use pumps, blowers, filtration systems, and other electrical equipment. Their distribution systems require reliable protection against abnormal current conditions.

Circuit breakers can protect major feeders and distribution sections, helping maintenance teams isolate faulty equipment.

5. Commercial and Infrastructure Facilities

Large commercial buildings, transportation facilities, and infrastructure installations use low-voltage switchboards to distribute power to lighting, ventilation, mechanical systems, and other loads.

A suitable industrial circuit breaker can provide switching and protection within these systems when its technical ratings match the installation.

Installation and System Integration

The correct installation of a circuit breaker is essential for electrical safety and reliable operation.

1. Verify the Complete Model

Before installation, confirm that the breaker nameplate identifies the required MT10N2 configuration.

Check the complete product reference, frame rating, trip-unit type, pole arrangement, mounting style, rated voltage, and breaking capacity. Do not assume that every breaker carrying a similar MT designation has identical electrical characteristics.

2. Check the Electrical System

Determine the nominal system voltage, maximum operating current, prospective short-circuit current, and required protection characteristics.

The breaker must be suitable for the electrical system at the installation point. Its interrupting rating must be equal to or greater than the prospective fault current under the applicable system conditions.

3. Confirm Panel Dimensions

The supplied dimensions are 301 × 196 × 276 mm. Verify the actual dimensional drawing and mounting arrangement before designing or modifying the switchboard.

Allow enough space for electrical connections, operating mechanisms, maintenance access, ventilation, and any required accessories.

For replacement projects, compare the mounting and connection arrangements of the existing breaker with the replacement unit. Similar external dimensions do not guarantee mechanical or electrical compatibility.

4. Inspect Electrical Connections

Inspect the terminals, busbar connections, insulating components, and contact areas before installation.

Connections must be correctly aligned and tightened according to the manufacturer’s specified torque values. Loose connections can create excessive resistance, overheating, and equipment damage.

5. Configure Protection Settings

Where an adjustable trip unit is installed, protection settings should be established by qualified personnel according to the electrical protection study.

Consider the load current, cable ratings, downstream protective devices, fault levels, and coordination requirements.

Do not use assumed settings based only on the 1000 A frame reference.

6. Commissioning and Testing

Before energizing the equipment, qualified personnel should complete the required installation inspections and electrical tests.

Verify the mechanical operation, trip mechanism, control wiring, auxiliary contacts, and protection functions where applicable. Follow the manufacturer’s commissioning and maintenance procedures.

Electrical testing and commissioning must be carried out by qualified personnel using appropriate procedures and equipment.

Compatible System Components

The MT10N2 may be installed as part of a larger power distribution assembly. The following components are commonly associated with industrial circuit breaker installations.

Component Function Integration Considerations
Low-voltage switchboard Houses power distribution equipment Confirm the breaker mounting and connection arrangement
Copper busbar system Distributes electrical power Verify current capacity, short-circuit withstand, and connection dimensions
Protection trip unit Detects abnormal current conditions Confirm the exact trip-unit model and protection functions
Auxiliary contacts Provide breaker status signals Verify contact configuration and control-circuit ratings
Shunt trip accessory Enables remote electrical tripping Confirm accessory compatibility and operating voltage
Undervoltage release Trips or prevents closing under specified voltage conditions Verify the exact accessory and control supply
Current transformers Provide current signals for measurement or protection Confirm ratio, accuracy, burden, and system design
Power monitoring equipment Measures electrical operating conditions Verify signal interfaces and metering requirements
Downstream circuit breakers Protect individual outgoing circuits Coordinate trip characteristics and interrupting ratings
PLC or supervisory system Monitors selected electrical status signals Check auxiliary-contact availability and interface requirements

Not every listed component is included with the breaker. The actual accessory configuration must be confirmed before ordering.

Alternative Models and Replacement Considerations

When replacing an MT10N2 circuit breaker, the alternative must be selected according to the complete electrical and mechanical requirements of the original installation.

Alternative or Related Product Replacement Considerations
Another Schneider Masterpact MT breaker Verify frame rating, trip unit, pole configuration, mounting, and electrical ratings
Schneider Masterpact NT series Different product family; check dimensions, connections, accessories, and ratings
Schneider Masterpact NW series May be considered for suitable distribution applications, subject to engineering review
Schneider Masterpact MTZ series A newer product family that may support modernization projects but is not automatically a direct replacement
Other industrial air circuit breakers Compare voltage, current, interrupting capacity, protection functions, and mechanical compatibility

Before selecting a replacement, verify:

  • Complete catalog number and product identification.
  • Frame rating and trip-unit rating.
  • Rated operational voltage and frequency.
  • Rated uninterrupted current.
  • Short-circuit breaking capacity.
  • Number of poles.
  • Fixed or withdrawable mounting arrangement.
  • Busbar and terminal connection dimensions.
  • Auxiliary contacts and electrical accessories.
  • Protection coordination with upstream and downstream devices.
  • Switchboard dimensions and mechanical interlocking requirements.

A replacement breaker should not be selected solely because its frame rating is similar. Changes to the breaker family or mounting arrangement may require switchboard modifications and an updated protection assessment.

Key Advantages

Industrial Power Protection

Circuit breakers provide an essential means of protecting electrical distribution circuits against abnormal current conditions when correctly rated and configured.

High-Current Distribution Applications

The MT10N2 designation is associated with a 1000 A frame rating, making it relevant to industrial distribution equipment designed for higher-current circuits. The actual permissible operating current depends on the installed trip unit and product configuration.

Integrated Switching and Protection

A circuit breaker combines switching and protective functions within a single device, supporting electrical distribution and fault isolation.

System-Level Protection Coordination

When integrated into a properly designed protection scheme, the breaker can help isolate faults while maintaining the operation of unaffected distribution sections.

Maintenance and Replacement Applications

Masterpact equipment is used in industrial and infrastructure power distribution systems. Accurate identification of legacy breaker models can support maintenance planning and replacement sourcing.

Industrial Switchboard Integration

The breaker can form part of an appropriately engineered low-voltage switchboard, subject to verification of mounting, busbar connections, electrical ratings, and accessories.

Technical FAQs

1. What is the Schneider MT10N2 Circuit Breaker?

The Schneider MT10N2 is a circuit breaker associated with the Masterpact MT range. Available product references identify MT10N2 with a 1000 A frame rating. Its complete electrical configuration should be verified from the nameplate.

2. What does the MT10N2 designation indicate?

The designation identifies a particular Masterpact MT product configuration. It should not be used alone to determine every electrical specification, such as trip-unit rating, breaking capacity, or mounting arrangement.

3. Is the MT10N2 a 1000 A circuit breaker?

Available product references list MT10N2 in the 1000 A frame category. The actual rated current and protection settings depend on the installed trip unit and complete breaker configuration.

4. What is the weight of the Schneider MT10N2?

The supplied product listing weight is 14 kg. Confirm whether this refers to the bare breaker, an assembly, or a packaged product before using it for transportation calculations.

5. What are the dimensions of the MT10N2?

The supplied dimensions are 301 × 196 × 276 mm. Verify the physical unit and manufacturer’s dimensional drawing before planning a switchboard installation.

6. Can the MT10N2 protect industrial motors?

A circuit breaker can form part of a motor-feeder protection arrangement when correctly selected and coordinated with the motor starter and overload protection. The breaker alone should not be assumed to provide every required motor-protection function.

7. Can the MT10N2 be used in a low-voltage switchboard?

It may be used in an appropriately designed low-voltage distribution assembly if the complete product configuration matches the system voltage, current, fault level, and mounting requirements.

8. How do I select a replacement for the MT10N2?

Compare the frame rating, trip unit, rated voltage, interrupting capacity, pole configuration, mounting type, connection arrangement, and accessories. Mechanical and electrical compatibility must both be confirmed.

9. What should be checked before purchasing a used MT10N2?

Check the complete nameplate, trip-unit model, mechanical condition, contact condition, operating mechanism, terminals, accessories, and available inspection or test records. For critical installations, request suitable testing by a qualified service provider.

10. Does the MT10N2 include auxiliary contacts or remote-control accessories?

The supplied product description does not establish the accessory configuration. Confirm the actual installed auxiliary contacts, releases, motor mechanisms, and other accessories before purchasing.

Procurement and Maintenance Recommendations

When sourcing the Schneider MT10N2 Circuit Breaker, the most important step is to confirm the exact product configuration. The MT10N2 designation and 1000 A frame reference are useful for identification, but they do not replace the complete nameplate information.

Purchasing teams should request clear photographs of the breaker nameplate, trip unit, front panel, terminals, and accessory positions. These details help determine whether the offered unit matches the existing switchboard installation.

For used or refurbished equipment, inspect the operating mechanism, contact system, insulation condition, terminal connections, and visible signs of overheating or mechanical damage. Where the breaker is intended for a critical distribution circuit, request appropriate inspection and functional test documentation.

During maintenance, follow the manufacturer’s inspection intervals and procedures. Check the mechanical operating mechanism, electrical connections, protective functions, auxiliary circuits, and condition of the switchboard. Any protection-setting changes should be documented and reviewed by qualified electrical personnel.

For replacement projects, verify the switchboard’s mechanical and electrical requirements before ordering. A breaker with a similar frame rating may have different mounting dimensions, terminal arrangements, trip characteristics, or accessory requirements.

Conclusion

The Schneider MT10N2 Circuit Breaker is associated with the Masterpact MT industrial circuit breaker range and a 1000 A frame rating. It is intended for use in appropriately engineered electrical distribution systems where switching, overload protection, and short-circuit protection are required.

The supplied listing dimensions are 301 × 196 × 276 mm, with a weight of 14 kg. Since the exact trip unit, pole configuration, mounting arrangement, and breaking capacity cannot be established from the MT10N2 designation alone, these details should be verified before procurement or installation.

Accurate model identification, electrical compatibility checks, and proper protection coordination are essential for maintaining the safety and reliability of industrial power distribution systems.