• Schneider MT16H1 Circuit Breaker
  • Schneider MT16H1 Circuit Breaker
  • Schneider MT16H1 Circuit Breaker
  • Schneider MT16H1 Circuit Breaker
Product Overview The Schneider MT16H1 Circuit Breaker is listed as an industrial low-voltage circuit protection device intended for use in electrical power distribution systems. Circuit breakers play an……
Schneider MT16H1 Circuit Breaker
  • Schneider
  • MT16H1
  • Circuit Breaker
  • France
  • 322 x 277 x 288 mm
  • 30 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider MT16H1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MT16H1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MT16H1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MT16H1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider MT16H1 Circuit Breaker is listed as an industrial low-voltage circuit protection device intended for use in electrical power distribution systems. Circuit breakers play an essential role in protecting electrical installations by interrupting current when abnormal operating conditions, such as overloads or short circuits, occur.

In industrial facilities, circuit protection equipment is commonly installed in main distribution boards, switchgear assemblies, motor control centers, and other electrical panels. These systems supply power to production machinery, automation equipment, motors, and auxiliary services. A properly selected circuit breaker helps protect cables and connected equipment from damage caused by excessive current and electrical faults.

The MT16H1 designation is associated with the Schneider MasterPact 16H1 naming family, but the exact complete product reference should be confirmed before procurement. Schneider Electric documentation includes related MasterPact MTZ1 16H1 and NT16H1 products. These products can differ in construction, mounting arrangement, trip-unit configuration, and electrical characteristics.

A documented MasterPact MTZ1 16H1 drawout three-pole configuration has a rated current of 1600 A and a 42 kA ultimate short-circuit breaking capacity at 415 V AC. It is designed for low-voltage power distribution protection and can be configured with a separate electronic protection unit. These figures are reference specifications for that documented configuration and should not be assumed to apply automatically to every product identified as MT16H1.

For maintenance and replacement projects, checking the full catalog number, nameplate, pole configuration, mounting type, and trip-unit arrangement is essential. A similar model designation does not necessarily indicate direct interchangeability.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Model Provided MT16H1
Product Type Industrial Circuit Breaker
Product Family MasterPact designation requires confirmation
Device Application Low-Voltage Power Distribution Protection
Reference Configuration MasterPact MTZ1 16H1, three-pole drawout
Reference Rated Current 1600 A
Reference Breaking Capacity 42 kA at 415 V AC
Reference Operational Voltage Up to 690 V AC
Reference Frequency 50/60 Hz
Reference Insulation Voltage 1000 V AC
Reference Impulse Withstand Voltage 12 kV
Reference Pole Configuration 3P
Reference Mounting Drawout
Reference Protection Unit MicroLogic X compatible; configuration dependent
Dimensions Provided 322 × 277 × 288 mm
Weight Provided 30 kg
Typical Application Industrial switchgear and power distribution systems

Important: The electrical reference values above relate to documented MasterPact MTZ1 16H1 configurations, not a confirmed complete MT16H1 catalog number. Verify the exact nameplate and Schneider Electric product reference before using these values for equipment selection or replacement.

Function and Working Principle

A circuit breaker is designed to carry normal operating current and interrupt electrical current when a fault or abnormal condition occurs. Its protection mechanism helps reduce the risk of damage to electrical conductors, switchgear, and connected equipment.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating level for a sustained period.

In industrial power distribution systems, overloads may result from excessive connected loads, equipment malfunction, or incorrect system operation. Depending on the installed protection unit, the circuit breaker monitors current and initiates a trip when the configured overload protection threshold and timing conditions are reached.

This helps prevent cables and electrical components from operating under excessive thermal stress.

2. Short-Circuit Protection

A short circuit can produce a very high fault current within a short period. If the fault is not interrupted, it may cause severe heating, mechanical stress, and damage to electrical equipment.

A suitably rated circuit breaker is designed to detect and interrupt fault current within its specified breaking capacity. The selected breaker must be appropriate for the prospective short-circuit current at the installation point.

For a documented MTZ1 16H1 reference configuration, the H1 breaking-capacity rating is 42 kA at 415 V AC. Actual protection selection must be based on the full product reference and system fault calculations.

3. Electrical Isolation

Circuit breakers can also provide a means of isolating electrical circuits for inspection and maintenance, provided the specific device is rated and installed for that purpose.

Isolation procedures should always follow the applicable electrical safety rules. The breaker must be placed in the correct position, and the absence of hazardous voltage must be verified before work begins.

4. Electronic Protection and Monitoring

Depending on the selected configuration, a MasterPact circuit breaker may be equipped with an electronic trip unit. Such units can provide adjustable protection functions and operating information.

The exact protection functions depend on the installed trip unit and accessories. A basic breaker frame supplied without a trip unit should not be assumed to provide the same protection or monitoring capabilities as a fully configured breaker.

Role in Industrial Power Distribution Systems

The MT16H1 designation is relevant to high-current industrial power distribution equipment. Circuit breakers in this class are typically installed where large electrical loads require coordinated protection and switching.

Main Distribution Boards

In a main distribution board, a high-current circuit breaker can protect an incoming supply or a major outgoing feeder. It helps separate a faulty section from the rest of the electrical installation when the protection system operates correctly.

This can reduce the extent of electrical disruption and support safer maintenance procedures.

Industrial Switchgear

Industrial switchgear combines switching, protection, isolation, and monitoring equipment. A suitably configured MasterPact circuit breaker can form part of a switchgear assembly serving production lines, plant utilities, and large electrical loads.

The breaker must be compatible with the switchgear’s busbar arrangement, mounting system, electrical ratings, and control requirements.

Motor Control Centers

Large industrial motor control centers distribute power to multiple motor feeders and associated equipment. Main and feeder circuit breakers provide protection and isolation at different points in the distribution system.

The breaker rating and protection coordination must be selected according to the connected loads, motor starting characteristics, cable ratings, and available fault current.

Power Distribution Coordination

In a multi-level electrical distribution network, circuit breakers are selected and coordinated so that the device closest to a fault can interrupt the affected circuit where possible.

Proper coordination helps reduce unnecessary interruption of upstream equipment. The final settings must be determined through engineering analysis rather than relying only on the breaker frame rating.

Industrial Applications

1. Manufacturing Plants

Manufacturing facilities use large electrical distribution systems to supply production machinery, automation lines, compressors, pumps, and auxiliary equipment.

A high-current circuit breaker can serve as a main or feeder protection device within a suitably designed distribution board. Its rating and trip characteristics must match the electrical installation.

2. Industrial Power Distribution Rooms

Power distribution rooms contain switchgear and protective equipment that distribute electricity throughout a facility.

A MasterPact-class breaker may be used in incoming or outgoing circuits where high current ratings and defined short-circuit interruption capabilities are required.

3. Process Industries

Chemical processing, water treatment, metallurgy, and other process industries depend on stable electrical supplies for pumps, compressors, heating systems, and control equipment.

Circuit breakers help protect these power circuits and provide a means of separating faulty sections for inspection and repair.

4. Infrastructure and Utility Facilities

Large infrastructure installations may contain high-current distribution systems supplying ventilation, pumping, building services, and other critical electrical loads.

Circuit protection must be coordinated with the installation’s operating requirements and fault levels.

5. Data Centers and Large Commercial Facilities

Large facilities require dependable power distribution for electrical infrastructure, cooling equipment, and auxiliary systems.

Circuit breakers are selected according to the distribution architecture, fault-current levels, selectivity requirements, and maintenance strategy. The exact MT16H1 configuration must be confirmed before considering it for any specific installation.

Installation and System Integration

Circuit breakers carrying high currents must be installed and commissioned by qualified electrical personnel.

1. Verify the Complete Product Reference

Before installation, confirm the full Schneider Electric catalog number and the nameplate information.

Check whether the device is an MTZ1, NT, or another MasterPact configuration. Confirm the rated current, pole count, breaking capacity, mounting type, and installed protection unit.

Do not use the shortened MT16H1 designation as the only basis for selecting a replacement.

2. Confirm Electrical Ratings

The circuit breaker’s voltage and current ratings must be appropriate for the electrical system.

The prospective short-circuit current at the installation point must not exceed the breaker’s applicable interrupting capacity. The protection settings must also coordinate with cable ratings and downstream protective devices.

3. Check Mounting and Switchgear Compatibility

For drawout breakers, confirm the chassis, guide rails, primary disconnect contacts, mechanical interlocks, and position-indication arrangements.

A breaker from a different MasterPact generation or mounting configuration may not fit the existing chassis even if the current rating and general appearance are similar.

The supplied dimensions are 322 × 277 × 288 mm. Verify the actual dimensional drawing and required installation clearances before designing or modifying the switchgear compartment.

4. Inspect Busbar and Terminal Connections

Inspect connection surfaces, busbars, terminals, and contact assemblies for signs of overheating, corrosion, deformation, or mechanical damage.

Connection torque must follow the manufacturer’s instructions. Incorrect contact pressure or unsuitable connections can increase resistance and lead to excessive heating.

5. Configure the Protection Unit

If the breaker uses an electronic trip unit, its protection settings must be selected according to the electrical system study.

Relevant considerations may include long-time overload protection, short-time protection, instantaneous protection, and ground-fault protection where supported by the installed unit.

Settings should be documented and reviewed by qualified personnel. Incorrect settings can compromise protection coordination or equipment safety.

6. Commissioning and Functional Testing

Before energizing the installation, verify the mechanical condition, electrical connections, control wiring, interlocks, and grounding arrangement.

Carry out the tests required by the manufacturer’s commissioning instructions and the applicable electrical standards. Confirm that the breaker can be operated and that the protection and auxiliary functions behave as intended.

Compatible System Components

A high-current circuit breaker is part of a larger switchgear and power distribution assembly. The following components may be used in a compatible installation, depending on the exact breaker version.

Component Function Compatibility Considerations
MasterPact chassis Supports a drawout breaker Must match the breaker generation and frame
Electronic trip unit Provides configured protection functions Verify the correct trip-unit family and rating
Busbar system Distributes electrical power Confirm current rating, spacing, and connection arrangement
Auxiliary contacts Provide breaker status signals Verify contact configuration and terminal assignments
Shunt trip release Enables remote electrical tripping Confirm operating voltage and accessory compatibility
Undervoltage release Trips or prevents closing under defined voltage conditions Confirm coil rating and breaker compatibility
Closing release Supports electrical closing operation Check control voltage and accessory reference
Motor mechanism Enables electrical charging or operating functions where applicable Confirm the mechanism type and catalog reference
Switchgear compartment Houses and supports the breaker Verify dimensions, clearances, and drawout interface
Protection and control system Coordinates monitoring and circuit protection Confirm trip-unit and communication capabilities

The table lists typical switchgear components, not a statement that they are supplied with every MT16H1 unit.

Alternative Models and Replacement Considerations

Schneider Electric offers several MasterPact circuit breaker families and configurations. A replacement must be selected according to the complete electrical and mechanical requirements.

Related Product Family General Description Replacement Considerations
MasterPact MTZ1 16H1 1600 A class MasterPact MTZ1 configuration Verify pole count, mounting, trip unit, and breaking capacity
MasterPact NT16H1 Related 1600 A NT family designation Not automatically interchangeable with MTZ1
MasterPact MTZ2 Larger MasterPact frame family Check frame size, current rating, chassis, and switchgear compatibility
MasterPact NW MasterPact air circuit breaker family Requires detailed electrical and mechanical comparison
Other MasterPact 16H configurations Related high-current breaker variants Compare the H-level breaking capacity and full catalog number

Before choosing a replacement, review:

  • Complete catalog number and product generation.
  • Rated operational voltage and current.
  • Number of poles.
  • Ultimate and service short-circuit breaking capacities.
  • Fixed or drawout mounting arrangement.
  • Chassis and compartment compatibility.
  • Trip-unit type and protection functions.
  • Auxiliary contacts and electrical releases.
  • Control voltage and wiring.
  • Busbar and terminal connection arrangements.
  • Applicable electrical standards and certification.

A replacement breaker must be approved for the installation by qualified electrical engineers. Similar product names or frame ratings do not establish interchangeability.

Key Advantages

High-Current Power Distribution

The related MasterPact 16H1 configurations are designed for high-current low-voltage distribution applications, making them relevant to large industrial electrical systems.

Short-Circuit Protection

A suitably rated breaker can interrupt fault currents within its specified breaking capacity, helping protect connected electrical equipment.

Overload Protection

When equipped with the appropriate protection unit, the breaker can protect electrical circuits against sustained excessive current.

Switchgear Integration

MasterPact circuit breakers are designed for use in compatible switchgear assemblies, supporting structured power distribution and maintenance operations.

Drawout Configuration Options

Certain configurations use a drawout mounting arrangement, which can support inspection and maintenance workflows when the correct chassis and safety procedures are used.

Expandable Protection Functions

Depending on the selected trip unit and accessories, the breaker may support additional protection, control, and monitoring functions.

Technical FAQs

1. What is the Schneider MT16H1 Circuit Breaker?

MT16H1 is the model designation supplied for this listing. Schneider documentation includes similar MasterPact MTZ1 16H1 and NT16H1 designations. The complete catalog number is required to identify the exact device.

2. What is the rated current?

A documented MasterPact MTZ1 16H1 three-pole configuration has a rated current of 1600 A at 40°C. Confirm the exact product reference before applying this value to the MT16H1 listing.

3. What does the H1 designation mean?

H1 identifies a short-circuit breaking-capacity performance level within the relevant MasterPact product family. The exact breaking capacity depends on the breaker series and rated operating voltage.

For the referenced MTZ1 16H1 configuration, the documented ultimate breaking capacity is 42 kA at 415 V AC.

4. Is the breaker suitable for industrial switchgear?

The related MasterPact configurations are intended for low-voltage power distribution and protection applications. Actual suitability depends on electrical ratings, switchgear compatibility, and the complete product configuration.

5. What is the difference between a fixed and drawout circuit breaker?

A fixed breaker is installed directly in its mounting position. A drawout breaker is designed to be inserted into and withdrawn from a compatible chassis. Drawout arrangements can support maintenance and isolation procedures, but require the correct chassis and interlocks.

6. Does the breaker include a MicroLogic trip unit?

The answer depends on the exact catalog number. Some MasterPact breaker-frame references are supplied without a trip unit, which must be selected separately. Verify the product description and installed hardware before purchase.

7. Can MT16H1 replace MTZ1 16H1?

The shortened designations are not sufficient to establish interchangeability. Compare the complete catalog numbers, electrical ratings, mechanical dimensions, chassis, and protection accessories.

8. What should be checked before purchasing?

Confirm the complete product reference, nameplate, rated current, voltage, pole count, breaking capacity, mounting type, trip unit, and accessory configuration. For used equipment, inspect the contacts, mechanism, terminals, and available test records.

9. What are the dimensions and weight of this listing?

The supplied listing dimensions are 322 × 277 × 288 mm, and the supplied weight is 30 kg. Confirm whether these figures refer to the breaker alone or an assembly that includes the chassis or packaging.

10. Why is the full catalog number important?

Schneider MasterPact products may have similar family names while differing in frame generation, mounting, protection unit, and accessory arrangement. The complete reference helps prevent ordering an incompatible breaker.

Procurement and Maintenance Recommendations

When purchasing a Schneider MT16H1 circuit breaker, begin by verifying the exact model reference from the nameplate or original equipment documentation. Do not rely solely on the shortened designation.

For replacement projects, compare the rated current, voltage, breaking capacity, pole count, mounting arrangement, and protection unit. Also check whether the required chassis, auxiliary contacts, electrical releases, and other accessories are included.

For used or refurbished units, request clear photographs of the front panel, nameplate, terminals, contact areas, and operating mechanism. Ask for available inspection or test records and confirm the seller’s warranty and return conditions.

During maintenance, inspect the breaker and switchgear compartment according to the manufacturer’s maintenance schedule. Pay attention to contact wear, overheating, mechanical operation, terminal condition, interlocks, and protection-unit settings.

Any inspection or servicing involving high-current switchgear must be carried out by qualified personnel using appropriate isolation, lockout, and electrical safety procedures.

Conclusion

The Schneider MT16H1 Circuit Breaker is listed as an industrial circuit protection device for low-voltage power distribution applications. Related MasterPact 16H1 configurations are used in high-current switchgear and may provide overload and short-circuit protection when equipped with the appropriate protection unit.

The supplied listing dimensions are 322 × 277 × 288 mm, with a weight of 30 kg. However, the exact product identity should be confirmed because Schneider Electric documentation distinguishes between related MTZ1 16H1 and NT16H1 products.

For procurement, maintenance, and replacement work, checking the complete catalog number and matching the electrical and mechanical configuration are essential steps toward ensuring a safe and compatible installation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501