Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider Electric MT40N2 Circuit Breaker is an industrial low-voltage circuit protection device intended for use in high-capacity electrical distribution systems. Associated with the Masterpact MT product family, it is designed for applications where reliable power distribution, circuit isolation, and protection against electrical faults are essential.
Circuit breakers play an important role in industrial electrical infrastructure. They monitor electrical circuits and interrupt current when abnormal conditions occur, helping protect cables, switchgear, transformers, motors, and connected equipment from damage caused by overloads and short circuits.
The MT40N2 is listed as a 4000 A circuit breaker. This high-current rating makes it relevant to main distribution systems and large electrical installations. Typical application environments include manufacturing facilities, industrial plants, commercial buildings, and power distribution rooms.
As part of a low-voltage distribution arrangement, the breaker is normally installed in a compatible switchboard or switchgear assembly. Its protection performance depends on the complete configuration, including the trip unit, current sensors, operating mechanism, pole arrangement, and rated breaking capacity.
The full catalog number and nameplate information should always be checked before selecting this circuit breaker for a replacement project. Similar-looking breakers may have different electrical ratings, mounting arrangements, and protection functions.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Model | MT40N2 |
| Product Type | Circuit Breaker |
| Product Family | Masterpact MT |
| Breaker Category | Low-Voltage Power Circuit Breaker |
| Listed Rated Current | 4000 A |
| Protection Purpose | Electrical circuit protection and isolation |
| Typical Protection Functions | Overload and short-circuit protection, subject to installed trip unit |
| Application | Industrial low-voltage power distribution |
| Dimensions Provided | 301 × 196 × 276 mm |
| Weight Provided | 14 kg |
Important: The exact pole count, rated operational voltage, frequency, ultimate breaking capacity, short-time withstand current, trip-unit type, and mounting arrangement must be confirmed from the breaker nameplate and original technical documentation. The dimensions and weight above are the supplied listing values and should be checked against the actual unit.
The MT40N2 is designed to control and protect an electrical distribution circuit. Its primary function is to carry normal operating current and interrupt the circuit when an abnormal electrical condition is detected by the installed protection system.
During normal operation, the circuit breaker provides an electrical connection between the incoming power source and the downstream distribution circuit.
The breaker must be selected according to the system’s rated voltage, operating current, load characteristics, and installation requirements. For a high-capacity device listed at 4000 A, correct coordination with the upstream and downstream electrical equipment is particularly important.
An overload occurs when a circuit carries more current than its intended operating capacity for a sustained period.
Depending on the installed protection unit, the breaker can detect an overload condition and initiate a trip after a defined response period. This helps reduce excessive heating in conductors and electrical equipment.
The overload protection settings must be coordinated with cable ratings, transformer capacity, connected loads, and the overall distribution design.
A short circuit can produce a very high fault current within a short period. If not interrupted promptly, this current may cause severe thermal and mechanical stress.
A suitably configured circuit breaker detects the fault through its protection system and operates the interruption mechanism. Its ability to interrupt a fault safely depends on the rated breaking capacity and the prospective short-circuit current at the installation point.
The exact breaking capacity of the MT40N2 must be verified from the nameplate and technical documentation rather than inferred from the 4000 A current rating.
Circuit breakers also provide a means of disconnecting electrical circuits for maintenance and operational control, subject to the device’s approved isolation characteristics.
Before maintenance, the electrical system must be isolated using the appropriate procedures. Operators should follow lockout/tagout requirements and verify the absence of hazardous voltage.
In a complex distribution network, multiple circuit breakers may be installed at different levels. Their protection settings should be coordinated so that a fault is interrupted by the appropriate protective device.
Proper coordination can help limit unnecessary power interruptions and maintain the availability of unaffected sections of the electrical system.
The MT40N2 can serve as a major switching and protection component within a low-voltage electrical distribution system.
In large industrial installations, a main incoming breaker connects the facility’s low-voltage distribution system to the upstream electrical supply.
A high-current circuit breaker can provide the switching and protection functions required at this distribution point, provided that its voltage, current, and fault-interruption ratings match the system design.
The breaker may be installed in a compatible low-voltage switchboard or switchgear assembly. The switchboard provides the mechanical structure, busbar connections, electrical clearances, and supporting protection equipment.
Mechanical compatibility must be checked carefully. Frame dimensions, terminal arrangements, mounting method, and connection orientation can vary between breaker models.
Industrial facilities often distribute electrical power through several levels of switchgear and distribution panels. A main circuit breaker works with downstream protective devices to isolate faults and maintain power to unaffected circuits where possible.
The protection settings of the MT40N2 should therefore be reviewed as part of the complete distribution protection study.
Modern electrical distribution systems may use auxiliary contacts, trip indicators, communication accessories, or external monitoring equipment to report breaker status.
The availability of these functions depends on the installed accessories and configuration. They should not be assumed to be included with every MT40N2 unit.
Large manufacturing plants require stable electrical distribution for production machinery, utility systems, and automated equipment.
A high-capacity circuit breaker can be used at an appropriate distribution point to provide circuit switching and protection. Correct coordination helps support reliable power delivery across different production areas.
Electrical distribution rooms contain switchgear, busbars, transformers, and protective devices that distribute power throughout a facility.
The MT40N2 may be considered for a compatible high-current distribution application where its electrical ratings and installation configuration meet the system requirements.
Large commercial buildings and infrastructure facilities may have substantial electrical loads associated with HVAC systems, lighting, elevators, pumps, and other building services.
A suitably rated main circuit breaker can support the protection and isolation requirements of the building’s low-voltage distribution system.
Transformers and downstream switchgear require appropriately selected protective devices. A high-current circuit breaker may be used on the low-voltage side of a transformer where its voltage, current, and fault-interruption capabilities are suitable.
Protection coordination must account for transformer impedance, available fault current, and downstream circuit characteristics.
Chemical plants, water treatment facilities, mining operations, and other process industries depend on electrical distribution systems to support continuous operations.
A properly selected power circuit breaker can help protect major distribution circuits and support planned maintenance isolation.
Correct installation is essential for electrical safety and reliable circuit protection.
Before installation, confirm the breaker nameplate and verify:
The listed 4000 A rating alone is not sufficient to determine whether the breaker is suitable for a particular installation.
Check the switchboard or switchgear documentation to ensure that the breaker is mechanically and electrically compatible.
Important considerations include mounting dimensions, busbar connection arrangements, terminal orientation, required clearances, and any interlocking mechanisms.
Do not assume that breakers from different Masterpact generations can be exchanged without checking the manufacturer’s compatibility information.
Before commissioning, inspect the main terminals, busbar interfaces, control wiring, and grounding arrangements.
Connections should be installed and tightened according to the manufacturer’s specified procedures and torque values. Loose or incorrectly installed connections can cause overheating and equipment damage.
The installed protection unit must be configured according to the electrical system design.
Protection settings should consider conductor ampacity, transformer characteristics, connected loads, prospective fault current, and coordination with upstream and downstream devices.
Only qualified personnel should modify protection settings or perform protection testing.
Before energizing the system, qualified technicians should complete the required mechanical and electrical inspections.
Depending on the breaker configuration and applicable commissioning standards, testing may include:
The commissioning procedure should follow the manufacturer’s documentation and the site’s electrical safety requirements.
A high-capacity circuit breaker normally operates as part of a complete electrical distribution assembly.
| Component | Function | Integration Considerations |
|---|---|---|
| Low-voltage switchgear | Houses and supports the circuit breaker | Confirm frame size, mounting, clearances, and electrical ratings |
| Main busbars | Distribute electrical power | Verify current capacity, connection arrangement, and temperature limits |
| Protection trip unit | Detects abnormal electrical conditions | Confirm the installed type and available protection functions |
| Current sensors or transformers | Provide current measurement for protection and monitoring | Verify compatibility with the protection system |
| Auxiliary contacts | Report breaker operating status | Check contact configuration and control voltage |
| Shunt trip accessory | Allows electrical remote tripping | Confirm the accessory is installed and its rated control voltage |
| Undervoltage release | Initiates tripping under specified voltage conditions | Verify accessory compatibility and operating characteristics |
| Operating mechanism | Opens and closes the breaker | Inspect the mechanism and follow maintenance procedures |
| Power distribution cables | Connect the breaker to the electrical network | Select according to current, voltage, installation method, and fault conditions |
| Electrical monitoring system | Collects operating and status information | Confirm available communication or auxiliary interfaces |
These components are examples of equipment that may be used in a complete installation. They are not necessarily supplied with the MT40N2 circuit breaker.
When replacing an older high-capacity circuit breaker, selecting a device with the same nominal current rating is not enough. The complete electrical and mechanical configuration must be evaluated.
| Alternative or Related Product Family | Replacement Considerations |
|---|---|
| Schneider Electric Masterpact MT | Relevant family for identifying legacy equipment and matching original configurations |
| Schneider Electric Masterpact NT | Different product family; verify frame size, ratings, and mounting compatibility |
| Schneider Electric Masterpact NW | High-capacity circuit breaker family that may be considered for selected applications |
| Schneider Electric MasterPacT MTZ | Newer product family that may support modernization projects, subject to engineering review |
| Other manufacturers’ low-voltage power circuit breakers | Must meet the same electrical, mechanical, and protection requirements |
Before selecting a replacement, compare:
A replacement breaker may require changes to the switchboard, busbar connections, protection coordination, and control wiring. Any modification should be evaluated and approved by qualified electrical engineers.
The listed 4000 A rating makes the MT40N2 relevant to high-capacity low-voltage distribution applications when confirmed by the actual nameplate.
When fitted with a compatible protection unit, the breaker can provide protection against overload and short-circuit conditions.
A power circuit breaker supports controlled circuit switching and isolation for suitable electrical distribution arrangements.
The Masterpact MT family is associated with industrial and commercial low-voltage distribution systems. Correct configuration matching is important when maintaining existing installations.
When properly configured as part of a coordinated protection system, the breaker can help limit the effects of electrical faults and maintain continuity in unaffected sections of a facility.
Accurate identification of the MT40N2 can help maintenance teams source replacement equipment for existing switchgear and plan electrical system upgrades.
The Schneider MT40N2 is listed as a low-voltage power circuit breaker associated with the Masterpact MT family. It is intended for high-current electrical distribution applications.
Available product listing information identifies the MT40N2 as a 4000 A circuit breaker. Confirm this rating against the actual nameplate before installation or replacement.
The protection functions depend on the installed trip unit and accessories. A correctly configured breaker may provide overload and short-circuit protection. The exact protection settings and functions should be checked from the installed hardware.
It may be suitable for a main incoming circuit where the electrical ratings, fault-interruption capability, mounting arrangement, and protection coordination meet the system requirements.
The supplied product description does not establish the exact trip-unit configuration. Check the installed trip unit, model number, and protection functions before purchasing.
Verify the rated voltage, current, pole count, breaking capacity, trip-unit configuration, mounting type, terminal arrangement, accessories, and switchgear compatibility.
A Masterpact MTZ breaker may be considered for a modernization project, but it should not be assumed to be a direct replacement. Electrical ratings, mechanical dimensions, busbar connections, accessories, and protection coordination must be reviewed.
Maintenance may include visual inspection, connection checks, mechanical operation checks, accessory inspection, protection testing, and other procedures specified by the manufacturer. The maintenance interval should reflect operating conditions and applicable standards.
Rated current describes the current the breaker is designed to carry under specified conditions. Breaking capacity describes the maximum fault current the breaker can safely interrupt under defined voltage and test conditions. These are different electrical characteristics and must be evaluated separately.
The dimensions of 301 × 196 × 276 mm and weight of 14 kg are the supplied listing values. Confirm them against the physical unit and its mounting documentation before designing a replacement or arranging shipment.
When purchasing the Schneider MT40N2, begin by checking the complete product identification and the information printed on the nameplate. For high-capacity circuit breakers, the trip-unit configuration, pole arrangement, rated voltage, and fault-interruption capability are just as important as the model designation.
For used or refurbished equipment, request clear photographs of the front panel, nameplate, terminals, operating mechanism, and installed accessories. Ask for available inspection or functional test records, and confirm the condition of the breaker before placing an order.
The supplied dimensions and weight should be used as preliminary listing information. Verify the actual shipping dimensions and packed weight separately, especially if the breaker is supplied with mounting hardware or other accessories.
For maintenance, follow the manufacturer’s procedures for inspection, cleaning, mechanical operation, connection checks, and protection testing. Do not carry out maintenance on energized equipment unless a specific approved procedure permits it. Electrical isolation and lockout/tagout requirements must be observed.
For replacement projects, compare the complete electrical and mechanical specifications rather than relying on the nominal 4000 A rating. A correctly matched breaker helps maintain the intended protection level and reduces the risk of incompatibility with the existing switchgear.
The Schneider Electric MT40N2 Circuit Breaker is listed as a 4000 A low-voltage power circuit breaker associated with the Masterpact MT family. It is intended for high-capacity electrical distribution systems where circuit switching, isolation, and coordinated electrical protection are required.
Its suitability for a particular installation depends on the complete breaker configuration, including rated voltage, pole arrangement, trip unit, breaking capacity, mounting arrangement, and installed accessories. For maintenance and replacement applications, verifying these details against the original equipment documentation is essential for safe and reliable operation.