Product Overview The Schneider MT25N2 Circuit Breaker is identified as a Masterpact MT series low-voltage air circuit breaker used in industrial power distribution and electrical protection systems. Air……
Schneider MT25N2 Circuit Breaker
  • Schneider
  • MT25N2
  • Circuit Breaker
  • France
  • 301 x 196 x 276 mm
  • 14 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider MT25N2 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MT25N2 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MT25N2 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MT25N2 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider MT25N2 Circuit Breaker is identified as a Masterpact MT series low-voltage air circuit breaker used in industrial power distribution and electrical protection systems. Air circuit breakers are designed to protect electrical installations against abnormal current conditions, including overloads and short circuits, while also providing switching and isolation functions in appropriately designed distribution systems.

The Masterpact MT family is intended for demanding power distribution applications where reliable circuit interruption, electrical protection, and integration into switchgear assemblies are important. These breakers are commonly used in industrial facilities, commercial buildings, power distribution rooms, and other installations with substantial electrical loads.

The MT25 designation is associated with a 2,500 A frame-current class in available product-selection information. However, the complete MT25N2 catalog designation should be checked against the manufacturer’s nameplate and documentation to establish its exact configuration. Rated current, operating voltage, breaking capacity, pole arrangement, and trip-unit functions must not be determined from the frame designation alone.

As a circuit breaker, the MT25N2 is intended to interrupt current when specified electrical protection conditions are detected. Depending on the installed trip unit and accessories, a Masterpact breaker can provide protection functions such as overload and short-circuit protection, as well as electrical status monitoring and auxiliary signaling.

For replacement projects, the complete model identification is essential. Two circuit breakers from the same product family may differ in electrical ratings, trip units, connection arrangements, installation methods, and accessories.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Model MT25N2
Product Series Masterpact MT
Product Type Air Circuit Breaker
Frame Current Class 2,500 A (MT25 designation; verify exact configuration)
Protection Function Electrical overload and short-circuit protection, depending on trip-unit configuration
Operating Voltage Verify from product nameplate
Rated Current Verify exact breaker and trip-unit rating
Number of Poles Verify from nameplate
Breaking Capacity Depends on the exact interrupting rating
Trip Unit Verify installed protection unit
Installation Type Verify fixed or withdrawable configuration
Dimensions Provided 301 × 196 × 276 mm
Weight Provided 14 kg
Application Industrial low-voltage power distribution

Important: The dimensions and weight are supplied listing values and have not been independently confirmed against a Schneider Electric dimensional drawing for MT25N2. Confirm the exact product configuration before using them for installation or logistics.

Function and Working Principle

The Schneider MT25N2 is categorized as an air circuit breaker. Its primary function is to establish, carry, and interrupt electrical current in a power distribution circuit under specified operating conditions.

Unlike a simple manual disconnect switch, an air circuit breaker incorporates a protection and interruption mechanism designed to respond to abnormal electrical conditions.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating level for an extended period.

Depending on the installed trip unit, the breaker can monitor current and initiate a trip when the overload condition exceeds the configured protection threshold.

This helps protect cables, busbars, transformers, motors, and other connected equipment from excessive heating.

2. Short-Circuit Protection

A short circuit can cause a sudden and substantial increase in current. If not interrupted quickly, the resulting electrical and thermal stress can damage equipment and create serious safety hazards.

The circuit breaker’s trip mechanism detects abnormal current conditions and operates the interruption mechanism according to its protection characteristics.

The actual short-circuit interruption capability depends on the exact breaker rating and the electrical system’s available fault current.

3. Arc Interruption

When a circuit breaker opens while current is flowing, an electrical arc may form between separating contacts.

Air circuit breakers use an arc-control and interruption arrangement to manage and extinguish the arc. The interruption system is designed to allow the breaker to disconnect the circuit safely within its specified operating limits.

Regular inspection and maintenance are important because contact wear, contamination, and mechanical deterioration can affect breaker performance.

4. Switching and Isolation

In addition to protective tripping, an appropriately configured air circuit breaker can provide controlled switching of power distribution circuits.

It may be used to connect or disconnect distribution sections, transformers, or other electrical equipment during normal operation and maintenance procedures.

The breaker must be operated according to the manufacturer’s instructions and the site’s electrical safety procedures.

5. Electrical Monitoring and Trip Indication

Depending on the trip-unit and accessory configuration, Masterpact circuit breakers can provide information about electrical conditions and breaker status.

Auxiliary contacts and signaling accessories may be used to communicate breaker position, trip status, or other conditions to a PLC, power management system, or supervisory control system.

The availability of these functions depends on the actual installed accessories.

Role in Industrial Power Distribution Systems

The MT25N2 can be considered a component of a low-voltage power distribution system. Its role is to provide switching and protection between the electrical source and downstream distribution circuits.

Main Distribution Board Protection

In industrial facilities, air circuit breakers may be installed in main distribution boards to protect major electrical feeders.

The breaker can help isolate a downstream circuit when a fault or abnormal current condition occurs, limiting the impact on other parts of the electrical installation.

Transformer Secondary Protection

A suitably rated air circuit breaker may be installed on the low-voltage side of a transformer.

Its protection settings and interruption capability must be coordinated with transformer characteristics, downstream protective devices, and the available short-circuit current.

Busbar Section Protection

Industrial switchgear may contain multiple busbar sections supplying different production areas or electrical loads.

Circuit breakers can be used to control and protect these sections. Their ratings and coordination settings must be selected according to the complete power distribution design.

Integration with PLC and SCADA Systems

A circuit breaker is primarily an electrical protection device rather than a programmable controller.

However, with suitable auxiliary contacts, communication accessories, and monitoring equipment, breaker status and selected electrical information may be integrated into PLC or SCADA systems.

This enables operators to monitor power distribution conditions and receive notifications when a breaker changes state or trips.

Industrial Applications

1. Manufacturing Plants

Manufacturing facilities often contain large electrical distribution networks supplying production lines, machinery, motors, and auxiliary systems.

Air circuit breakers can protect main feeders and distribution sections against abnormal current conditions.

2. Power Distribution Rooms

Industrial power distribution rooms require equipment capable of controlling and protecting electrical circuits.

A suitably configured Masterpact breaker may be installed in a low-voltage switchgear assembly to provide circuit interruption and protection.

3. Transformer Protection Systems

Transformers supply power to industrial distribution networks. A properly selected circuit breaker can provide protection on the appropriate side of the transformer.

The breaker rating and protection settings must be coordinated with transformer impedance, expected fault current, and downstream protection devices.

4. Commercial and Infrastructure Facilities

Large commercial buildings, infrastructure installations, and utility-related facilities may use air circuit breakers in their main electrical distribution systems.

Applications can include power distribution to lighting systems, HVAC equipment, elevators, pumps, and other major electrical loads.

5. Industrial Utility Systems

Industrial utility systems include compressed-air stations, cooling systems, water treatment equipment, and other essential services.

Circuit breakers help protect the electrical feeders supplying these systems and support safe isolation during maintenance.

6. Large Electrical Switchgear Assemblies

Masterpact circuit breakers are designed for integration into compatible low-voltage switchgear arrangements.

The installation must account for breaker dimensions, connection arrangements, busbar capacity, insulation requirements, and the manufacturer’s mounting instructions.

Installation and System Integration

Correct installation is essential for electrical safety and reliable circuit protection.

1. Verify the Electrical Ratings

Before installation, verify the following information from the actual breaker nameplate:

  • Rated operational voltage.
  • Rated current.
  • Number of poles.
  • Rated short-circuit breaking capacity.
  • Rated short-time withstand current, where applicable.
  • Trip-unit model and protection settings.
  • Fixed or withdrawable construction.

The MT25 frame designation alone is not sufficient to establish all electrical ratings.

2. Confirm Switchgear Compatibility

The breaker must be compatible with the switchgear assembly in which it will be installed.

Check the mounting arrangement, connection terminals, busbar dimensions, electrical clearances, and mechanical interlocking requirements.

Do not assume that a breaker from the same product family will fit an existing installation without checking its complete configuration.

3. Electrical Connection

Power connections must be installed according to the manufacturer’s technical instructions and applicable electrical regulations.

Ensure that connection surfaces are clean and that terminals are tightened to the specified torque. Incorrect connections may create excessive contact resistance and overheating.

Appropriate grounding and insulation arrangements must also be maintained.

4. Protection Coordination

The breaker’s trip settings should be coordinated with upstream and downstream protective devices.

Protection coordination helps ensure that a fault is isolated by the most appropriate protective device, reducing unnecessary interruption to unaffected circuits.

The settings should be based on the electrical system study and the characteristics of connected equipment.

5. Mechanical Inspection

Before commissioning, inspect the operating mechanism, contact condition, mounting points, and any installed accessories.

For withdrawable versions, verify the correct operation of the racking mechanism and mechanical interlocks according to the manufacturer’s instructions.

6. Commissioning and Testing

Before placing the breaker into service, qualified personnel should perform the required electrical and mechanical inspections.

Testing may include:

  • Visual inspection.
  • Mechanical operation checks.
  • Verification of auxiliary contacts.
  • Trip-unit configuration checks.
  • Protection function testing.
  • Connection and insulation inspections.
  • Verification of electrical interlocks.

All testing should follow the manufacturer’s procedures and the applicable site safety requirements.

Compatible System Components

The Schneider MT25N2 is generally used within a larger power distribution assembly.

Component Function Integration Considerations
Low-voltage switchgear Houses and organizes power distribution equipment Verify breaker frame and mounting compatibility
Busbar system Distributes electrical power Check current capacity, connection dimensions, and temperature limits
Protection trip unit Detects abnormal current conditions and initiates tripping Confirm exact model and protection functions
Auxiliary contacts Provide breaker status signals Verify contact ratings and wiring arrangement
Shunt trip accessory Enables remote electrical tripping Confirm accessory compatibility and control voltage
Undervoltage release Trips or prevents operation under specified voltage conditions Check the required supply and accessory configuration
PLC Monitors breaker status and coordinates automation Requires suitable auxiliary signals or communication hardware
SCADA system Supervises electrical distribution conditions Depends on the installed monitoring and communication accessories
Current transformers Provide current measurement signals where required Confirm ratios, accuracy, and protection-system design
Electrical protection relay Provides additional protection and monitoring functions Coordinate settings with the circuit breaker

Not all components are included with the circuit breaker. The actual accessories and trip-unit configuration should be checked before ordering.

Alternative Models and Replacement Considerations

When replacing a Schneider Masterpact MT25N2, selecting another circuit breaker based only on its frame current is not sufficient.

The replacement must match the electrical and mechanical requirements of the original installation.

Alternative Product Family Considerations
Schneider Masterpact MT Series Check frame rating, interrupting capacity, trip unit, and mounting configuration
Schneider Masterpact MTZ Series A newer product family that may be considered for switchgear modernization; engineering verification is required
Schneider PowerPacT P-Frame A different circuit-breaker family; verify application and electrical compatibility
Schneider PowerPacT R-Frame Intended for different current ranges and applications; not automatically interchangeable
Other manufacturer air circuit breakers May be considered for system upgrades after detailed electrical and mechanical assessment

Important replacement checks include:

  1. Rated operational voltage.
  2. Continuous current rating.
  3. Short-circuit breaking capacity.
  4. Short-time withstand current.
  5. Number of poles.
  6. Protection trip-unit characteristics.
  7. Fixed or withdrawable installation.
  8. Busbar and terminal arrangement.
  9. Auxiliary contacts and accessories.
  10. Switchgear dimensions and mechanical interlocks.

Any replacement should be reviewed by qualified electrical engineers before installation.

Key Advantages

High-Current Power Distribution

The MT25 designation is associated with a 2,500 A frame-current class, making accurate selection and configuration important for high-current distribution applications.

Circuit Protection

The air circuit breaker design provides a means of protecting electrical circuits against specified overload and short-circuit conditions when fitted with the appropriate protection unit.

Switching Capability

A suitably configured breaker can support electrical switching and isolation operations in industrial distribution systems.

Integration with Switchgear

Masterpact breakers are designed for use in compatible low-voltage switchgear assemblies, supporting organized power distribution and maintenance.

Expandable Accessory Configuration

Depending on the exact version, auxiliary contacts, trip accessories, and monitoring equipment may be available to support broader electrical control and supervision requirements.

Industrial Power System Applications

Air circuit breakers are widely used in industrial distribution environments where protection coordination, switching reliability, and maintainability are essential.

Technical FAQs

1. What is the Schneider MT25N2?

The Schneider MT25N2 is identified as a Masterpact MT series air circuit breaker used in low-voltage electrical distribution systems.

2. What does MT25 mean?

The MT25 designation is associated with a 2,500 A frame-current class in available product-selection information. The exact rated current of a complete breaker must be confirmed from its nameplate and trip-unit configuration.

3. What is the main function of this circuit breaker?

Its primary function is to protect and control electrical distribution circuits by interrupting current under specified abnormal conditions, including overloads and short circuits.

4. Can the MT25N2 be used in industrial switchgear?

It may be used in compatible low-voltage switchgear assemblies. The mounting arrangement, electrical ratings, terminal connections, and accessory configuration must be verified before installation.

5. Does this model support remote monitoring?

Remote monitoring depends on the installed auxiliary contacts, communication accessories, and monitoring equipment. The basic breaker designation alone does not confirm a particular communication capability.

6. Can it protect transformers?

A suitably rated and configured air circuit breaker can be used in transformer protection arrangements. The protection settings and breaking capacity must be coordinated with the transformer’s electrical characteristics and the distribution system.

7. How should the breaker be maintained?

Maintenance should follow the manufacturer’s procedures and may include inspection of contacts, operating mechanisms, terminals, insulation, trip units, and accessories.

8. Can the MT25N2 replace another Masterpact MT breaker?

Only after confirming the full electrical and mechanical configuration. Frame rating alone does not guarantee compatibility.

9. What should be checked before purchasing?

Confirm the complete catalog number, nameplate ratings, trip-unit model, number of poles, physical condition, installed accessories, and fixed or withdrawable construction.

10. Are the supplied dimensions and weight verified?

The supplied listing values are 301 × 196 × 276 mm and 14 kg. These figures should be checked against the exact product configuration and manufacturer dimensional documentation before use in engineering or shipping calculations.

Procurement and Maintenance Recommendations

The Schneider MT25N2 should be purchased according to its complete identification and electrical configuration rather than the frame designation alone.

For maintenance and replacement projects, request a clear photograph of the nameplate and verify the rated voltage, current, breaking capacity, pole arrangement, and trip-unit model.

For used or refurbished breakers, inspect the contact system, operating mechanism, terminals, insulation, and auxiliary accessories. Where possible, request suitable functional and protection testing documentation.

Before ordering, confirm whether the breaker is supplied with its trip unit, connection terminals, auxiliary contacts, and other required accessories. These items can affect the installation and overall procurement cost.

For installation planning, verify the physical dimensions and mounting arrangement against the switchgear drawings. The supplied dimensions and weight should be treated as preliminary listing data until confirmed.

Regular maintenance should follow the manufacturer’s recommendations and applicable electrical safety standards. Inspection records and protection settings should be documented to support future troubleshooting and replacement.

Conclusion

The Schneider MT25N2 Circuit Breaker is identified with the Masterpact MT family of low-voltage air circuit breakers. It is intended for electrical distribution applications where circuit switching and protection against abnormal current conditions are required.

The MT25 designation is associated with a 2,500 A frame-current class, but the complete breaker ratings and configuration must be verified from the product nameplate and technical documentation.

For industrial procurement, maintenance, and replacement applications, confirming the full catalog reference, trip unit, breaking capacity, installation arrangement, and accessory configuration is essential to ensuring compatibility and reliable operation.