Product Overview The Schneider Electric MT12N2 Masterpact MT Circuit Breaker is an industrial low-voltage air circuit breaker (ACB) designed for power distribution and electrical protection in large com……
Schneider MT12N2 Circuit Breaker
  • Schneider
  • MT12N2
  • Circuit Breaker
  • France
  • 537 x 297 x 352 mm
  • 35 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Schneider MT12N2 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MT12N2 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MT12N2 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MT12N2 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric MT12N2 Masterpact MT Circuit Breaker is an industrial low-voltage air circuit breaker (ACB) designed for power distribution and electrical protection in large commercial and industrial installations. As part of the Masterpact MT family, it is intended for applications where reliable interruption of abnormal electrical currents and controlled isolation of power circuits are essential.

Air circuit breakers are commonly installed in main distribution boards, switchboards, generator systems, and industrial power-control panels. They protect electrical networks against overloads and short circuits by detecting abnormal current conditions and opening the circuit when the configured protection thresholds are exceeded.

The MT12N2 is associated with a 1250 A rated-current class. Its N2 designation identifies a particular performance configuration within the Masterpact MT range. The actual short-circuit breaking capacity must be checked against the applicable voltage, standard, and product nameplate rather than inferred from the model suffix alone.

In a typical industrial distribution system, an air circuit breaker serves as an important protective and switching device between the incoming power source and downstream electrical loads. It can help protect busbars, cables, transformers, motors, and distribution equipment when correctly selected and coordinated with the rest of the protection system.

The exact configuration of an MT12N2 unit may depend on its pole arrangement, mounting design, trip unit, auxiliary contacts, operating mechanism, and installed accessories. These details should be verified before purchasing a replacement or integrating the breaker into an existing switchboard.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family Masterpact MT
Model MT12N2
Product Type Air Circuit Breaker (ACB)
Device Application Low-voltage power distribution and protection
Rated Current Class 1250 A
Performance Designation N2
Network Type AC
Protection Functions Overload and short-circuit protection, depending on trip-unit configuration
Mounting Configuration Verify fixed or drawout version
Pole Configuration Verify actual unit
Trip Unit Verify installed trip-unit model
Auxiliary Contacts Configuration dependent
Operating Mechanism Verify installed mechanism
Dimensions Provided 537 × 297 × 352 mm
Weight Provided 35 kg
Typical Installation Industrial switchboards and main distribution panels

Note: The dimensions and weight are supplied listing values. Confirm the exact product configuration and manufacturer’s dimensional drawing before panel design, replacement, or shipping.

Function and Working Principle

The Schneider MT12N2 is designed to provide switching and electrical protection in a low-voltage AC distribution system. Its operation involves current detection, protection evaluation, mechanical tripping, and interruption of the electrical circuit.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating level for a sustained period. Prolonged overload conditions can cause conductors and electrical equipment to overheat.

The breaker uses its installed protection unit to monitor current and determine whether an overload condition requires interruption. Depending on the trip-unit configuration, overload protection settings may be adjustable.

Correct protection settings are important because they must account for cable ratings, connected loads, transformer characteristics, and the overall distribution-system design.

2. Short-Circuit Protection

A short circuit can produce a very high current within a short period. If the fault is not interrupted, the resulting thermal and electromagnetic forces may damage busbars, cables, switchgear, and connected equipment.

The breaker is designed to open its contacts when the configured protection system detects a qualifying fault. Its ability to interrupt the fault safely depends on the rated breaking capacity at the actual system voltage and the characteristics of the installation.

The N2 designation should not be used as a substitute for checking the manufacturer’s short-circuit rating tables.

3. Arc Interruption

When a circuit breaker opens under load or fault conditions, an electrical arc may form between its separating contacts. An air circuit breaker uses an arc-control and arc-extinguishing arrangement to interrupt the current.

The arc is managed within the breaker assembly so that the electrical circuit can be safely disconnected within the device’s specified operating limits.

This function is particularly important in industrial power distribution, where fault currents can be substantial.

4. Switching and Isolation

An air circuit breaker can also be used for controlled switching of a distribution circuit. Depending on its design and applicable standards, it may provide a means of isolating electrical equipment for maintenance.

However, the switching and isolation functions must be used according to the manufacturer’s instructions and the requirements of the electrical installation. A circuit breaker should not be assumed to provide every isolation or safety function required by a particular maintenance procedure.

5. Protection Coordination

The breaker is normally part of a coordinated protection system that may include upstream breakers, downstream circuit breakers, fuses, protective relays, and transformer protection.

Coordination helps ensure that the protective device closest to a fault operates where possible, limiting unnecessary interruption to other parts of the electrical network.

The correct settings depend on the system’s short-circuit study, load profile, conductor ratings, and protection philosophy.

Role in Industrial Power Distribution Systems

The MT12N2 can serve as a main or feeder protection device in industrial electrical distribution equipment. Its role is to control and protect a power circuit while supporting safe operation of downstream equipment.

Main Incoming Power Protection

In an industrial switchboard, an ACB may be installed at the incoming supply section. It can provide protection and switching for the distribution system downstream of the incoming source.

The breaker rating and protection settings must be matched to the incoming supply, transformer capacity, busbar rating, and expected fault level.

Feeder Circuit Protection

The breaker may also be used in a feeder section to protect a downstream distribution circuit. This arrangement is common in facilities with multiple production areas, machine groups, or auxiliary power systems.

Correct coordination with downstream protective devices helps limit the effect of a fault to the affected feeder where the system design permits.

Generator and Transformer Distribution

Industrial facilities may use circuit breakers in generator or transformer distribution arrangements. In these applications, breaker selection must account for source characteristics, fault-current contributions, operating sequences, and protection requirements.

The MT12N2 should only be applied where its verified electrical ratings and installed configuration are appropriate for the specific circuit.

Switchboard Monitoring and Control

Depending on the installed accessories, an ACB may provide auxiliary contacts and other status signals to a control or monitoring system.

These signals can be used by PLCs, electrical monitoring equipment, or supervisory systems to indicate breaker status and support operating procedures. The availability of these functions depends on the actual breaker configuration.

Industrial Applications

The Masterpact MT series is intended for power distribution and protection applications in industrial and commercial electrical systems.

1. Manufacturing Plants

Manufacturing facilities use distribution boards to supply production lines, machine tools, pumps, compressors, and other electrical loads.

An appropriately rated ACB can provide protection for an incoming supply or a major distribution feeder. The MT12N2 may be considered for installations where its verified current and interruption ratings match the system requirements.

2. Industrial Power Distribution Rooms

Main distribution rooms often contain large switchboards that divide incoming electrical power among different production areas.

A circuit breaker in this position helps protect the distribution circuit and provides a controlled switching point for authorized operating and maintenance personnel.

3. Commercial and Industrial Buildings

Large buildings may require high-current distribution equipment to supply HVAC systems, elevators, lighting networks, pumps, and other electrical infrastructure.

An ACB can form part of the main or sub-main distribution protection arrangement, subject to the installation’s electrical design.

4. Generator Distribution Systems

Backup generators are frequently connected to distribution switchboards through appropriately selected switching and protection devices.

The breaker must be compatible with generator output characteristics and the required transfer or switching arrangement. Protection settings should be reviewed for both normal and generator operating conditions.

5. Transformer Secondary Protection

A transformer secondary distribution panel may use an ACB to protect the outgoing busbar and feeder circuits.

The breaker must be selected according to transformer rating, secondary voltage, available fault current, cable capacity, and coordination requirements.

6. Utility and Infrastructure Facilities

Water treatment plants, transportation facilities, energy infrastructure, and other public-service installations depend on reliable electrical distribution.

Air circuit breakers can support protection and switching in these systems, provided that their ratings and operating arrangements are suitable for the application.

Installation and System Integration

Installing or replacing a large air circuit breaker requires careful verification of electrical, mechanical, and protection-system compatibility. Work should be performed by qualified personnel following the manufacturer’s instructions and applicable electrical safety standards.

1. Verify the Electrical Ratings

Before installation, confirm the system voltage, frequency, rated current, and prospective short-circuit current.

The MT12N2 is associated with a 1250 A current class, but the complete selection process must also consider the breaker’s rated operational voltage and short-circuit interruption capability.

Do not select a breaker based on rated current alone. The system fault level and protection coordination are equally important.

2. Confirm the Mechanical Configuration

Check whether the installed breaker is a fixed or drawout version. These configurations have different mounting arrangements and may require different switchboard components.

For a drawout installation, verify the compatibility of the cradle, guide rails, primary disconnect contacts, secondary connectors, and mechanical interlocks.

For a fixed installation, confirm the mounting structure, terminal arrangement, busbar connections, and required clearances.

3. Inspect Busbar and Terminal Connections

The busbar and terminal arrangement must be compatible with the breaker configuration. Check conductor size, connection surfaces, mechanical support, tightening requirements, and electrical clearances.

Incorrect connections can lead to overheating, increased contact resistance, or mechanical damage.

4. Verify the Trip Unit

The installed trip unit determines the available protection functions and adjustment options. Before commissioning, identify the exact trip-unit model and verify its supported protection settings.

Typical protection considerations include:

  • Long-time overload protection.
  • Short-time overcurrent protection.
  • Instantaneous short-circuit protection.
  • Ground-fault protection, where supported.
  • Alarm and status functions, where available.

Not every function is necessarily available on every MT12N2 configuration.

5. Check Auxiliary Accessories

Depending on the installation, the breaker may use auxiliary contacts, shunt releases, undervoltage releases, motor operators, and other accessories.

Verify the part numbers, control voltages, wiring diagrams, and mechanical compatibility of these components before connecting them to the control system.

6. Perform Commissioning Tests

Before energizing the switchboard, qualified personnel should inspect the installation and carry out the tests required by the manufacturer and applicable standards.

Testing may include mechanical operation, contact inspection, insulation checks, trip-unit verification, control-circuit testing, and functional checks of installed accessories.

Protection settings should be documented and reviewed against the approved coordination study before the breaker is placed into service.

Compatible System Components

The MT12N2 operates as part of a larger switchboard and electrical protection arrangement. The following components may be used in a compatible installation, depending on the breaker version and system design.

Component Function Compatibility Considerations
Masterpact MT cradle Supports a drawout breaker Must match the exact frame and breaker configuration
Trip unit Provides current sensing and protection functions Verify the installed trip-unit model and supported functions
Auxiliary contacts Provide breaker status signals Check contact arrangement and electrical ratings
Shunt trip release Allows remote electrical tripping Verify control voltage and accessory compatibility
Undervoltage release Trips or prevents closing under specified voltage conditions Confirm the required operating voltage and configuration
Motor operating mechanism Supports electrical charging or operation where fitted Verify exact breaker and mechanism compatibility
Switchboard busbars Carry current through the distribution assembly Confirm current rating, connection geometry, and clearances
PLC or monitoring system Receives status signals and coordinates operations Requires compatible auxiliary contacts or monitoring accessories
Upstream protective device Provides coordinated protection Confirm selectivity and fault-current coordination
Downstream circuit breakers Protect individual outgoing circuits Coordinate trip settings with the main breaker

These components are examples of equipment that may be part of a complete installation. They are not necessarily included with the MT12N2 breaker.

Alternative Models and Replacement Considerations

When replacing a Schneider Masterpact MT12N2, selecting another breaker with a similar current rating is not sufficient. The replacement must match the electrical, mechanical, and protection requirements of the switchboard.

Alternative or Related Option Considerations
Another Masterpact MT12N2 Suitable for like-for-like consideration if the complete configuration matches
Masterpact MT12N1 Related 1250 A model designation; verify performance class and mounting configuration
Masterpact MT16N2 Higher current class; not a direct substitute without system and protection review
Masterpact MTZ2 12N A different product generation; requires detailed electrical and mechanical compatibility assessment
Current-generation Schneider Electric ACB May be considered for a switchboard upgrade, subject to engineering review

Before selecting a replacement, compare:

  • Rated operational voltage.
  • Rated current and frame size.
  • Short-circuit breaking capacity.
  • Number of poles.
  • Fixed or drawout mounting arrangement.
  • Trip-unit model and protection functions.
  • Terminal and busbar connection dimensions.
  • Cradle and mechanical interlock compatibility.
  • Auxiliary contacts and electrical accessories.
  • Control voltage and operating mechanism.
  • Switchboard dimensions and installation clearances.

A replacement may require a new cradle, modified busbar connections, updated control wiring, or changes to the protection coordination study.

Key Advantages

High-Current Distribution Capability

The 1250 A current class makes the MT12N2 relevant to large industrial distribution circuits when its complete electrical ratings match the application.

Air Circuit Breaker Design

Its ACB design is intended for low-voltage power distribution, switching, and protection duties in industrial switchboards.

Overload and Short-Circuit Protection

When equipped with the appropriate trip unit and correctly configured, the breaker can protect distribution circuits against specified abnormal current conditions.

Integration with Switchboard Systems

Depending on the installed accessories, the breaker can provide auxiliary status signals and remote operating functions for suitable electrical control systems.

Maintenance and Replacement Applications

The Masterpact MT family is used in established industrial electrical installations. Accurate model identification can help maintenance teams source compatible equipment for existing switchboards.

Configurable Protection Arrangement

The actual protection functions depend on the installed trip unit and accessories, allowing the complete breaker assembly to be matched to the requirements of a particular distribution system.

Technical FAQs

1. What is the Schneider MT12N2?

The Schneider MT12N2 is a Masterpact MT series air circuit breaker designed for industrial low-voltage power distribution and circuit protection.

2. What is the rated current of the MT12N2?

The MT12N2 is associated with a 1250 A rated-current class. The actual nameplate and manufacturer’s documentation should be checked before installation or replacement.

3. What does the N2 designation mean?

N2 identifies a performance configuration within the Masterpact MT range. The exact short-circuit breaking capacity must be verified at the applicable operating voltage and standard.

4. Is the MT12N2 a molded case circuit breaker?

No. The MT12N2 belongs to the Masterpact MT air circuit breaker family. It is designed for larger low-voltage distribution applications than many conventional molded case circuit breakers.

5. Does the MT12N2 provide overload and short-circuit protection?

The breaker is designed for these protection duties when equipped with a suitable trip unit. The available protection functions and adjustment ranges depend on the installed trip-unit configuration.

6. Is the MT12N2 fixed or drawout?

The model designation alone should not be used to determine the mounting arrangement of an individual unit. Check the product label, mechanical structure, and associated switchboard documentation.

7. Can the MT12N2 be connected to a PLC?

It may be integrated into an appropriate control or monitoring system through compatible auxiliary contacts and electrical accessories. The exact functions depend on the installed hardware.

8. What should be checked before replacing an MT12N2?

Verify the rated voltage, current, breaking capacity, pole arrangement, mounting type, trip unit, accessory configuration, terminal arrangement, and switchboard dimensions.

9. Can an MTZ2 breaker replace an MT12N2 directly?

Not automatically. Masterpact MT and MTZ2 belong to different product generations. A replacement requires mechanical, electrical, protection, and accessory compatibility checks.

10. What information should be provided when ordering?

Provide the full model designation, nameplate photographs, pole arrangement, mounting type, trip-unit information, accessory details, and the dimensions of the installed breaker. This helps reduce the risk of ordering an incompatible unit.

Procurement and Maintenance Recommendations

When sourcing the Schneider Electric MT12N2, verify the complete model designation and inspect the breaker nameplate. The 1250 A rating is an important identification point, but it does not describe every electrical or mechanical characteristic of the unit.

For used, refurbished, or surplus equipment, request clear photographs of the front panel, side labels, terminals, operating mechanism, and trip unit. Confirm whether the breaker is supplied with a cradle, auxiliary contacts, operating accessories, or other components required by the installation.

For critical distribution systems, ask for appropriate inspection and functional-test information. Confirm the condition of the main contacts, arc-control components, operating mechanism, and electrical accessories before installation.

During maintenance, follow the manufacturer’s inspection and service instructions. Work on high-current switchgear should only be performed by qualified personnel using the required isolation, lockout, and verification procedures.

For replacement planning, retain the existing protection settings and switchboard drawings. Review the electrical coordination study whenever a breaker or trip unit is changed. A replacement with a similar current rating may still have a different breaking capacity, trip characteristic, or mounting arrangement.

Conclusion

The Schneider Electric MT12N2 Masterpact MT Air Circuit Breaker is a 1250 A class industrial protection device designed for low-voltage power distribution applications. It can form part of main incoming protection, feeder protection, and other large switchboard arrangements when its electrical ratings and configuration are suitable.

The exact performance of an individual MT12N2 depends on its rated voltage, breaking capacity, pole arrangement, mounting design, trip unit, and installed accessories. Careful verification of these details is essential when purchasing, maintaining, or replacing the breaker in an industrial electrical distribution system.