The Schneider Electric NT16H1 Circuit Breaker is part of the MasterPact NT series of low-voltage air circuit breakers (ACBs), designed for power distribution protection in industrial, commercial, and infrastructure electrical systems.
With a rated current of 1600 A, the NT16H1 is intended for applications where reliable protection and controlled switching of high-current electrical circuits are essential. It is designed to help protect electrical distribution systems against overloads and short circuits while supporting isolation and selective coordination within appropriately engineered power networks.
This model uses the H1 performance class, providing a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC. Its four-pole drawout configuration allows the breaker to be withdrawn from its compatible chassis for inspection, maintenance, or replacement without removing the entire switchgear assembly.
The NT16H1 product configuration described here is a basic circuit breaker frame supplied without a trip unit. A compatible MicroLogic control unit and the appropriate chassis must therefore be selected separately to create a complete operational protection arrangement.
The MasterPact NT16H1 is commonly considered for main distribution boards, industrial switchboards, generator distribution systems, and other low-voltage power distribution applications. Before installation or replacement, engineers should verify the pole configuration, rated current, breaking capacity, chassis compatibility, control unit, and accessory requirements.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Series | MasterPact NT |
| Model | NT16H1 |
| Product Type | Air Circuit Breaker |
| Device Application | Power Distribution Protection |
| Rated Current | 1600 A |
| Number of Poles | 4P |
| Performance Class | H1 |
| Rated Operational Voltage | Up to 690 V AC, 50/60 Hz |
| Breaking Capacity at 440 V AC | 42 kA |
| Rated Insulation Voltage | 1000 V AC |
| Rated Impulse Withstand Voltage | 12 kV |
| Mounting Type | Drawout |
| Control Unit | Not included |
| Control Type | Push-button |
| Selectivity Category | Category B |
| Suitability for Isolation | Yes, according to applicable IEC requirements |
| Dimensions | 322 × 358 × 277 mm |
| Weight | 39 kg |
| Typical Application | Industrial and commercial power distribution |
Note: This listing describes the basic four-pole drawout frame without a trip unit. The compatible chassis, MicroLogic control unit, and required accessories must be verified separately.
The Schneider NT16H1 is designed to protect and control high-current electrical distribution circuits. It operates as a switching and interruption device within a low-voltage power system.
Its operation involves several coordinated mechanical and electrical functions.
An overload occurs when a circuit carries more current than its intended operating level for a sustained period. Excessive current can cause conductors and connected equipment to overheat.
When equipped with a suitable compatible protection unit, the MasterPact NT16H1 can monitor circuit conditions and initiate a trip when the configured protection thresholds are exceeded.
The exact overload protection characteristics depend on the selected MicroLogic control unit and its settings. Since this basic frame is supplied without a trip unit, the required protection functions must be specified separately.
A short circuit can produce a very high fault current in a short period. If the fault is not interrupted, it can damage electrical equipment, cables, busbars, and connected machinery.
The NT16H1 H1 performance class provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC. This rating is an important selection parameter when coordinating the breaker with the prospective fault current at the installation point.
The actual protection arrangement must be designed around the available fault current, system voltage, protection settings, and applicable electrical standards.
The circuit breaker provides a means of switching and isolating electrical circuits. It can be used to connect or disconnect a distribution feeder as part of an appropriately designed switchgear system.
The drawout design allows the breaker to be moved between its operating and disconnected positions within a compatible chassis. This arrangement supports maintenance procedures and equipment replacement.
Isolation for maintenance must always follow the manufacturer’s operating instructions and the facility’s electrical safety procedures. A breaker position indicator alone should not replace proper verification of an electrically safe work condition.
In a distribution network, several protective devices may be installed between the power source and individual loads.
Selective coordination is intended to ensure that the protective device closest to a fault operates first where the system design allows. This can help limit unnecessary interruptions to unaffected circuits.
The NT16H1 belongs to selectivity category B. Actual coordination performance depends on the selected trip unit, protection settings, upstream and downstream devices, and the calculated fault conditions.
The drawout construction allows the breaker to be withdrawn from its chassis without dismantling the complete switchboard.
This design can simplify inspection, replacement, and maintenance in installations where compatible drawout switchgear is used. The chassis and breaker must be correctly matched, and racking operations must follow the manufacturer’s procedures.
The NT16H1 can serve as a high-current protective switching device in industrial electrical distribution systems.
In a main distribution board, the breaker may be used to protect an incoming supply or a major distribution feeder. Its 1600 A rating makes it suitable for appropriately engineered high-current circuits.
The final selection must consider the load profile, conductor capacity, busbar rating, fault level, and protection coordination requirements.
The drawout configuration is intended for installation in compatible switchgear assemblies. It can be integrated into a distribution system containing busbars, metering equipment, protection devices, and auxiliary control circuits.
The correct chassis, electrical connections, interlocks, and mechanical accessories must be selected for the specific installation.
Industrial facilities may use generators as standby or supplementary power sources. A suitable air circuit breaker can form part of the generator distribution and switching arrangement.
Generator protection involves additional considerations, including generator fault characteristics, short-circuit current contribution, neutral grounding, and coordination with other protective devices. The breaker must be selected and configured for the actual generator system.
The drawout design can support maintenance planning by allowing the breaker to be withdrawn from its chassis for inspection or replacement.
This can be particularly useful in facilities where electrical distribution equipment is critical to production continuity. Maintenance procedures must still follow approved isolation, testing, and safety requirements.
Manufacturing facilities often contain large motors, production lines, heating equipment, and centralized electrical distribution systems.
The NT16H1 may be used as a main or feeder circuit breaker where the system requires a 1600 A-class protective switching device and the available fault current is within its rated breaking capacity.
Data centers require carefully coordinated power distribution systems to support servers, cooling equipment, UPS systems, and other critical loads.
A suitable MasterPact NT breaker can form part of a low-voltage distribution assembly. Selection should consider redundancy architecture, fault-current levels, protection coordination, and the facility’s continuity requirements.
Large commercial buildings may use high-current distribution boards to supply lighting, HVAC systems, elevators, and other building services.
The NT16H1 can be considered for appropriately rated distribution feeders or main switching applications within a compatible switchgear installation.
Power generation and energy facilities use circuit breakers to manage electrical distribution and isolate circuits during abnormal conditions or maintenance.
The NT16H1 may be used in suitable low-voltage distribution sections, subject to the generator or transformer system’s electrical characteristics and protection study.
Infrastructure installations such as transportation facilities, water treatment plants, and large pumping stations require dependable electrical distribution.
A properly selected air circuit breaker can help protect major distribution circuits and support maintenance activities within the switchgear system.
The correct installation of a MasterPact NT16H1 is essential for electrical safety, reliable switching, and protection performance.
Before installation, confirm that the circuit voltage, rated current, and prospective short-circuit current are within the breaker’s permitted operating limits.
The NT16H1 has a rated current of 1600 A and an H1 breaking capacity of 42 kA at 440 V AC. The system’s calculated fault level must be checked against the applicable rating at the actual operating voltage.
Do not select a breaker based on rated current alone. The system’s fault level, protection coordination, and conductor ratings are equally important.
This model is a four-pole breaker. Its pole arrangement must match the electrical distribution system and the intended neutral-switching arrangement.
Engineers should confirm the neutral connection requirements and the applicable installation standards before selecting the breaker.
The drawout breaker requires a compatible chassis. The chassis is a separate component and must match the NT16H1 frame, pole configuration, and installation arrangement.
Before ordering, verify the chassis catalog number, connection type, and switchgear dimensions.
The basic frame described here does not include a trip unit. A compatible MicroLogic control unit must be selected according to the required protection functions.
Depending on the selected control unit, available functions may include long-time, short-time, instantaneous, and ground-fault protection, as well as measurement and monitoring capabilities.
The exact functions depend on the specific control unit and its configuration. Do not assume that all MicroLogic options are included with the basic frame.
Check the busbar connections, terminal surfaces, mechanical fasteners, and insulation clearances according to the manufacturer’s installation documentation.
Loose or incorrectly installed electrical connections can cause overheating and unreliable operation.
Drawout switchgear may use mechanical and electrical interlocks to prevent unsafe switching or racking operations.
Verify that the breaker, chassis, and associated interlocking components operate correctly before placing the equipment into service.
Before energizing the system, qualified personnel should verify:
Commissioning should be performed in accordance with Schneider Electric documentation and applicable electrical safety standards.
The NT16H1 is part of a wider low-voltage switchgear arrangement. The following components may be required depending on the installation.
| Component | Function | Compatibility Considerations |
|---|---|---|
| MasterPact NT chassis | Supports drawout installation | Must match the NT16H1 frame and four-pole configuration |
| MicroLogic trip unit | Provides circuit protection and monitoring functions | Select the appropriate compatible control unit |
| Main busbar system | Distributes electrical power | Verify current rating, connection arrangement, and fault withstand |
| Auxiliary contacts | Provide breaker status signals | Confirm contact configuration and accessory compatibility |
| Shunt trip release | Enables remote electrical tripping | Verify voltage and accessory compatibility |
| Undervoltage release | Trips or prevents closing under specified voltage conditions | Confirm control supply and required accessory |
| Closing release | Supports electrical closing operation | Verify control voltage and breaker configuration |
| Motor mechanism | Supports remote charging or operation where configured | Select according to the installed breaker arrangement |
| Switchboard enclosure | Houses the breaker and associated equipment | Confirm dimensions, clearances, and environmental requirements |
| Protection and metering system | Supports system monitoring and coordination | Verify electrical interface and protection design |
These components are not necessarily included with the basic breaker frame. Confirm the actual supply scope and required accessories before purchasing.
When replacing an NT16H1, the substitute must be evaluated against the original electrical and mechanical configuration.
| Alternative | Replacement Considerations |
|---|---|
| Schneider MasterPact NT16H2 | Similar NT16 frame family, but has a different H2 breaking-performance class |
| Schneider MasterPact NT16L1 | Different breaking-performance characteristics; requires a system-level evaluation |
| Schneider MasterPact MTZ2 16 | A newer product family that may be considered for an upgrade, subject to engineering review |
| Another MasterPact NT16H1 | May be suitable for like-for-like replacement if the pole arrangement, drawout configuration, chassis, and accessories match |
Before selecting a replacement, verify:
A replacement from a newer product family should not be assumed to fit the existing chassis or switchboard without checking the manufacturer’s conversion and installation requirements.
The 1600 A rated-current class makes the NT16H1 suitable for appropriately designed high-current distribution applications.
Its H1 performance class provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC.
The four-pole configuration can be used in distribution systems requiring switching of three phases and neutral, subject to the system design.
The drawout arrangement supports withdrawal and replacement within a compatible chassis, helping maintenance teams manage switchgear servicing.
The basic frame can be combined with a suitable MicroLogic control unit to provide the protection functions required by the electrical installation.
The MasterPact NT family is designed for low-voltage power distribution protection in industrial, commercial, and infrastructure environments.
The NT16H1 is a MasterPact NT air circuit breaker rated at 1600 A. The specified configuration is a four-pole, drawout basic frame without a trip unit.
Its rated current is 1600 A at the specified reference conditions. The actual application must be checked against ambient temperature, installation conditions, and system requirements.
The H1 version has a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC. The applicable rating must be checked at the actual system voltage.
The model described in this product listing is the four-pole version. Three-pole and four-pole NT16H1 configurations have different physical dimensions and weights.
No. The basic frame configuration described here is supplied without a control unit. A compatible MicroLogic trip unit must be selected separately.
Yes. The drawout basic frame must be installed in its corresponding compatible chassis. The chassis should be ordered and verified separately.
H1 and H2 identify different short-circuit performance classes within the MasterPact NT family. The NT H1 version has a 42 kA Icu/Ics rating at 440 V AC, while the H2 version has a different breaking-capacity specification. The correct version must be selected according to the system’s calculated fault level.
It may be suitable for certain generator distribution applications, provided its ratings, protection settings, and coordination characteristics match the generator system.
Confirm the full model, rated current, pole configuration, drawout arrangement, chassis compatibility, trip unit, accessories, and physical condition. The complete protection arrangement must also be checked against the installation’s electrical requirements.
The basic frame without a trip unit is not a complete protection solution. A compatible chassis, appropriate MicroLogic control unit, and any required accessories must be specified for the intended application.
When sourcing the Schneider Electric NT16H1, begin by identifying the exact configuration installed in the switchgear. Confirm whether the existing unit is three-pole or four-pole, fixed or drawout, and whether the required chassis and MicroLogic control unit are included in the procurement scope.
For replacement projects, compare the complete catalog numbers and accessory arrangements. A breaker with the same 1600 A rating may still have a different breaking capacity, connection arrangement, or mounting configuration.
For used or refurbished units, inspect the main contacts, operating mechanism, arc chambers, insulation components, racking mechanism, and visible signs of overheating or mechanical damage. Request clear nameplate photographs and available test documentation.
Maintenance should follow the manufacturer’s inspection and servicing schedule. Qualified personnel should examine electrical connections, mechanical operation, contact condition, trip-unit settings, auxiliary circuits, and interlock functions.
Because this equipment operates in high-current distribution systems, installation, testing, and maintenance must be performed by qualified electrical professionals using approved safety procedures.
The Schneider Electric NT16H1 MasterPact circuit breaker is a 1600 A, four-pole, drawout air circuit breaker designed for low-voltage power distribution protection. Its H1 performance class provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC.
The specified basic frame is supplied without a MicroLogic trip unit and requires a compatible chassis and protection control unit for a complete installation. For industrial replacement and maintenance projects, verifying the complete configuration, electrical ratings, and mechanical compatibility is essential for safe and reliable operation.