• Schneider NT10H1 Circuit Breaker
  • Schneider NT10H1 Circuit Breaker
  • Schneider NT10H1 Circuit Breaker
  • Schneider NT10H1 Circuit Breaker
Product Overview The Schneider Electric NT10H1 MasterPact Circuit Breaker is a low-voltage air circuit breaker designed to protect electrical distribution systems against overloads and short-circuit fau……
Schneider NT10H1 Circuit Breaker
  • Schneider
  • NT10H1
  • Circuit Breaker
  • France
  • 322 x 288 x 277 mm
  • 30 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 2

Our advantage

Schneider NT10H1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NT10H1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NT10H1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NT10H1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NT10H1 MasterPact Circuit Breaker is a low-voltage air circuit breaker designed to protect electrical distribution systems against overloads and short-circuit faults. It belongs to the MasterPact NT series, a range developed for demanding commercial and industrial power distribution applications.

The NT10H1 is designed for installations where high current capacity, dependable circuit interruption, and coordinated protection are essential. It can be used in main distribution boards, industrial switchgear, power distribution cabinets, and other low-voltage electrical installations.

This three-pole, drawout-type circuit breaker has a rated current of 1000 A at 40°C and a rated operational voltage of up to 690 V AC. Its H1 performance class provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC. These characteristics make it suitable for electrical distribution systems that require high-capacity circuit protection.

The drawout design allows the breaker to be withdrawn from its chassis for inspection, maintenance, or replacement without removing the entire switchgear assembly. This arrangement can simplify maintenance procedures and help reduce equipment downtime when supported by an appropriately designed switchgear system.

The NT10H1 configuration referenced in this article is a breaker frame supplied without a control unit. The required trip unit and accessories must therefore be confirmed separately according to the protection and control requirements of the installation.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series MasterPact NT
Model NT10H1
Product Type Air Circuit Breaker
Application Power Distribution Protection
Number of Poles 3P
Rated Current 1000 A at 40°C
Rated Operational Voltage Up to 690 V AC
Frequency 50/60 Hz
Performance Class H1
Rated Ultimate Breaking Capacity (Icu) 42 kA at 440 V AC
Rated Service Breaking Capacity (Ics) 42 kA at 440 V AC
Rated Short-Time Withstand Current (Icw) 42 kA for 0.5 s and 1 s; 24 kA for 3 s
Rated Insulation Voltage (Ui) 1000 V AC
Rated Impulse Withstand Voltage (Uimp) 12 kV
Mounting Type Drawout
Control Unit Not included in referenced configuration
Suitability for Isolation Yes, according to EN/IEC 60947-2
Dimensions 322 × 288 × 277 mm
Weight 30 kg
Typical Application Industrial and commercial low-voltage power distribution

Technical specifications refer to the documented three-pole drawout NT10H1 configuration. Verify the complete product reference and installed accessories before ordering.

Function and Working Principle

The NT10H1 is designed to protect electrical circuits by monitoring current conditions and interrupting the circuit when a qualifying fault occurs. Its operation is based on the protection system installed with the breaker.

1. Overload Protection

An overload occurs when electrical current remains above the permitted operating level for a period of time. Prolonged overload conditions can cause cables, busbars, and electrical equipment to overheat.

When equipped with a compatible trip unit, the MasterPact NT10H1 can provide long-time protection against overload conditions. The trip unit monitors the current and initiates a trip when the configured protection threshold and time delay are exceeded.

Correct protection settings are essential to coordinate the breaker with the load and upstream or downstream protective devices.

2. Short-Circuit Protection

A short circuit can produce extremely high current within a very short period. If not interrupted, this current can damage electrical equipment, conductors, and switchgear assemblies.

The NT10H1 H1 performance class provides a documented 42 kA ultimate breaking capacity at 440 V AC. This rating describes the breaker’s ability to interrupt a specified short-circuit current under defined test conditions.

The actual protection arrangement must be selected according to the prospective fault current at the installation point and the applicable electrical standards.

3. Protection Coordination

In a large distribution system, several circuit breakers may be installed at different levels. Their protection settings should be coordinated so that the breaker closest to a fault operates whenever possible.

This approach helps isolate the affected section while keeping unaffected parts of the electrical network in service.

The NT10H1 supports applications requiring coordinated protection, subject to the installed trip unit, system fault calculations, and protection-setting design.

4. Isolation and Switching

The MasterPact NT10H1 is suitable for isolation according to EN/IEC 60947-2. Its switching and isolation functions are important during electrical maintenance and system operation.

Isolation procedures must still follow the equipment manufacturer’s instructions and the facility’s electrical safety procedures. The breaker should never be treated as a substitute for all required lockout and verification measures.

5. Drawout Operation

The drawout construction allows the breaker to move between defined chassis positions, depending on the installed arrangement.

This design can make inspection and replacement more convenient than removing a complete fixed-mounted breaker from the switchgear. Mechanical and electrical interlocks help control the permitted operating sequence.

Operators must follow the prescribed racking procedure and confirm the breaker position before performing maintenance.

Role in Industrial Power Distribution Systems

The NT10H1 can serve as a main or feeder circuit protection device in industrial low-voltage distribution systems.

Main Distribution Protection

In a main distribution board, the breaker can protect a high-current incoming supply or a major distribution section. It helps isolate the downstream installation when an electrical fault occurs.

The selection of a main breaker requires evaluation of the supply characteristics, rated current, short-circuit level, and coordination with downstream protective devices.

Feeder Circuit Protection

The breaker can also be applied to protect high-current outgoing feeders supplying industrial equipment, secondary distribution boards, or large electrical loads.

Correct protection settings help ensure that faults are isolated appropriately without unnecessarily interrupting other parts of the facility.

Integration with Electrical Monitoring Systems

When equipped with compatible trip and communication accessories, MasterPact NT installations can be incorporated into broader electrical monitoring and energy-management systems.

Depending on the selected control unit and accessories, monitoring functions may include current measurements, trip indications, alarms, and other operating information.

The NT10H1 frame supplied without a control unit should not be assumed to include these monitoring or communication capabilities.

Industrial Applications

1. Manufacturing Facilities

Large manufacturing plants require reliable power distribution for production lines, motors, auxiliary systems, and process equipment.

The NT10H1 can be used in appropriately rated distribution switchgear to protect main feeders or high-current electrical sections.

2. Industrial Power Distribution Panels

Industrial distribution panels often contain several protective devices arranged to divide the electrical network into manageable sections.

The NT10H1’s 1000 A rating and drawout construction make it suitable for selected high-current distribution applications where its interrupting capacity meets the calculated fault level.

3. Commercial Buildings

Large commercial facilities may use low-voltage distribution equipment to supply HVAC systems, lighting distribution, elevators, and other electrical loads.

A suitable MasterPact NT10H1 configuration can provide protection for high-current distribution circuits within these installations.

4. Data Centers

Data centers depend on carefully designed electrical distribution systems to supply servers, cooling equipment, UPS systems, and supporting infrastructure.

Air circuit breakers can be used at selected distribution points to provide protection and facilitate maintenance. The NT10H1 should only be selected where its ratings and protection configuration meet the facility’s electrical design.

5. Infrastructure and Utility Facilities

Water treatment plants, transportation facilities, industrial substations, and other infrastructure installations require reliable low-voltage distribution.

The NT10H1 may be used in suitable switchgear assemblies to protect high-current feeders and distribution sections.

Installation and System Integration

Proper installation is essential for the safe and reliable operation of the NT10H1.

1. Verify Electrical Ratings

Before installation, confirm the system voltage, rated current, frequency, and prospective short-circuit current.

The NT10H1 is rated at 1000 A at 40°C, with a 42 kA H1 breaking capacity at 440 V AC. The calculated fault current at the installation point must not exceed the applicable breaking-capacity rating.

2. Confirm the Trip Unit Configuration

The referenced NT10H1 configuration is supplied without a control unit. A compatible trip unit must be selected according to the protection functions required by the electrical system.

Engineers should verify the trip unit type, sensor rating, protection functions, and compatibility with the breaker frame.

3. Prepare the Drawout Chassis

The drawout chassis must be compatible with the breaker frame and the intended switchgear assembly.

Before installation, inspect the guide rails, primary contacts, secondary connections, mechanical interlocks, and position-indication mechanisms.

The chassis should be correctly mounted and aligned to ensure reliable electrical connections and safe racking operation.

4. Connect the Main Conductors

Incoming and outgoing conductors must be selected according to the current rating, installation environment, and applicable electrical standards.

Check the terminal arrangement, conductor preparation, connection hardware, and tightening requirements specified by the manufacturer.

Incorrect connections can cause excessive temperature rise, contact damage, and unreliable operation.

5. Configure Protection Settings

After installing the appropriate control unit, configure the protection settings according to the system coordination study.

Relevant settings may include long-time, short-time, instantaneous, and ground-fault protection, depending on the installed trip unit.

Protection settings should be reviewed and approved by qualified electrical engineers.

6. Perform Commissioning Tests

Before energizing the equipment, inspect the mechanical and electrical installation. Verify the breaker operating mechanism, trip unit configuration, auxiliary contacts, interlocks, and indication functions.

Testing should follow the manufacturer’s commissioning procedures and applicable electrical safety standards.

Compatible System Components

The NT10H1 is part of a larger electrical distribution assembly. The following components may be required depending on the selected configuration.

Component Function Compatibility Considerations
Compatible MicroLogic trip unit Provides electronic protection functions Must match the NT10H1 frame and required protection functions
Current sensors Measure circuit current for protection Confirm sensor rating and trip-unit compatibility
Drawout chassis Supports the breaker and its racking positions Must match the three-pole NT frame configuration
Auxiliary contacts Provide breaker status signals Verify contact type and accessory compatibility
Shunt trip release Enables remote tripping Confirm rated control voltage and accessory compatibility
Undervoltage release Trips or prevents closing under specified voltage conditions Confirm the correct voltage and release type
Motor mechanism Supports electrical charging or operation where configured Verify the required mechanism and supply
Electrical distribution busbars Carry current through the switchgear assembly Check current rating, connection design, and thermal limits
Switchgear enclosure Provides mechanical protection and electrical segregation Must accommodate the drawout breaker and required clearances
Protection and monitoring system Supports system-level monitoring and coordination Depends on the installed trip unit and communication accessories

The breaker frame does not necessarily include these accessories. Confirm the actual supply scope before procurement.

Alternative Models and Replacement Considerations

The MasterPact NT family includes several frame and performance options. A replacement must be selected according to the electrical system requirements rather than model similarity alone.

Related Model General Rating or Characteristic Replacement Consideration
MasterPact NT08H1 800 A frame, H1 performance Lower frame rating; not a direct substitute without load assessment
MasterPact NT10H1 1000 A frame, H1 performance Same model family and performance class
MasterPact NT10H2 1000 A frame, H2 performance Higher interrupting performance at certain voltage levels; verify system coordination
MasterPact NT10L1 1000 A frame, L1 performance Different current-limiting and breaking characteristics
MasterPact NT12H1 1250 A frame, H1 performance Higher frame rating; verify conductor and protection requirements
MasterPact NT16H1 1600 A frame, H1 performance Higher frame rating and potentially different installation requirements

Before replacing the NT10H1, compare:

  • Rated operational voltage.
  • Rated current and sensor rating.
  • Number of poles.
  • Ultimate and service breaking capacities.
  • Short-time withstand current.
  • Trip-unit type and protection settings.
  • Fixed or drawout mounting arrangement.
  • Chassis and connection compatibility.
  • Auxiliary contacts and release accessories.
  • Switchgear dimensions and busbar connections.

A breaker with the same nominal current rating may still have different protection characteristics or mechanical interfaces. Replacement approval should be based on the complete electrical and mechanical design.

Key Advantages

High-Current Distribution Capability

The 1000 A rated current makes the NT10H1 suitable for selected high-current low-voltage distribution applications.

Short-Circuit Protection

Its H1 performance class provides a 42 kA ultimate breaking capacity at 440 V AC, subject to the specified operating conditions.

Drawout Construction

The drawout arrangement supports convenient withdrawal and maintenance when installed in a compatible switchgear chassis.

Industrial Power Distribution Design

The MasterPact NT family is designed for low-voltage power distribution protection in industrial and commercial installations.

Isolation Capability

The breaker is suitable for isolation according to EN/IEC 60947-2, supporting maintenance and switching arrangements when used with appropriate safety procedures.

Configurable Protection System

Compatible trip units and accessories allow the breaker assembly to be configured according to the protection and monitoring requirements of the installation.

Technical FAQs

1. What is the Schneider Electric NT10H1?

The NT10H1 is a MasterPact NT low-voltage air circuit breaker designed for power distribution protection. The referenced configuration is a three-pole, 1000 A, drawout-type breaker.

2. What is the rated current of the NT10H1?

Its rated current is 1000 A at 40°C.

3. What is the breaking capacity of the NT10H1?

The H1 performance class provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC. Its documented service breaking capacity is also 42 kA at this voltage.

4. What is the rated operational voltage?

The NT10H1 has a rated operational voltage of up to 690 V AC at 50/60 Hz.

5. Is the NT10H1 fixed or drawout?

The configuration described here is drawout type. Confirm the complete product reference before ordering because the MasterPact NT family also includes fixed-mounted versions.

6. Does the NT10H1 include a trip unit?

The referenced configuration is supplied without a control unit. A compatible trip unit must be selected separately according to the required protection functions.

7. What is the difference between H1 and H2?

H1 and H2 identify different performance classes within the MasterPact NT family. Their short-circuit breaking characteristics differ, so selection should be based on the installation’s calculated fault current and protection requirements.

8. Can the NT10H1 be used in a data center?

It may be used in suitable low-voltage distribution systems where its current rating, breaking capacity, trip-unit configuration, and switchgear arrangement meet the facility’s design requirements.

9. What should be checked before purchasing?

Confirm the complete model reference, pole count, drawout or fixed construction, rated current, trip-unit configuration, chassis, accessory list, and physical condition. For used equipment, request clear nameplate photographs and functional test information.

10. What are the dimensions and weight?

The supplied dimensions are 322 × 288 × 277 mm, and the listed weight is 30 kg. These values correspond to the documented three-pole drawout NT10H1 configuration.

Procurement and Maintenance Recommendations

When sourcing a Schneider Electric NT10H1, verify the complete product reference and determine whether the required trip unit and accessories are included. The NT10H1 designation alone does not establish the complete protection configuration.

For replacement projects, compare the original breaker’s electrical ratings, pole count, drawout arrangement, chassis, and trip-unit settings. A breaker with the same 1000 A rating may not be mechanically or electrically interchangeable.

For used or surplus units, inspect the operating mechanism, main contacts, arc chambers, drawout connections, trip unit, and auxiliary accessories. Request clear photographs of the nameplate and available test records.

Maintenance should follow Schneider Electric’s procedures and the facility’s electrical safety requirements. Regular inspection of contacts, mechanical mechanisms, connections, and protection settings can help identify deterioration before it affects system reliability.

Before returning the breaker to service, qualified personnel should perform the required mechanical, electrical, and protection tests. Record the installed accessories and final protection settings for future maintenance.

Conclusion

The Schneider Electric NT10H1 MasterPact Circuit Breaker is a three-pole, 1000 A drawout air circuit breaker designed for low-voltage industrial and commercial power distribution systems. With an H1 performance class, 42 kA breaking capacity at 440 V AC, and a drawout construction, it is suitable for selected high-current distribution applications.

For procurement and replacement, engineers should verify the complete breaker configuration, including the trip unit, chassis, and accessories. Correct electrical ratings, protection coordination, and mechanical compatibility are essential for safe and dependable operation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501