Product Overview The Schneider Electric NT12H1 MasterPact Circuit Breaker is a high-capacity air circuit breaker (ACB) designed for low-voltage power distribution and electrical protection in industrial……
Schneider NT12H1 Circuit Breaker
  • Schneider
  • NT12H1
  • Circuit Breaker
  • France
  • 322 x 288 x 277 mm
  • 30 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 1

Our advantage

Schneider NT12H1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NT12H1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NT12H1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NT12H1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NT12H1 MasterPact Circuit Breaker is a high-capacity air circuit breaker (ACB) designed for low-voltage power distribution and electrical protection in industrial and commercial installations. Part of the MasterPact NT family, it provides circuit switching and protection against electrical faults in power distribution systems.

The NT12H1 is designed for applications where reliable protection of high-current electrical circuits is essential. It is suitable for use in industrial power distribution panels, main switchboards, generator distribution systems, and other installations requiring high-current circuit protection.

This model has a rated current of 1250 A and an H1 short-circuit performance rating of 42 kA at 440 V AC. It supports operating voltages up to 690 V AC at 50/60 Hz and is designed according to IEC 60947-2 requirements.

The configuration associated with the supplied dimensions and weight is the three-pole drawout basic frame without a trip unit. The frame provides the mechanical and electrical platform for the circuit breaker, while a compatible Micrologic control unit must be selected separately. The corresponding chassis is also required for the drawout installation.

The drawout arrangement allows the breaker to be withdrawn from its connected operating position for inspection, maintenance, or replacement without removing the entire switchboard assembly.

For electrical engineers, maintenance teams, and industrial equipment buyers, the NT12H1 is an important component in high-current distribution systems where fault interruption, operational reliability, and maintenance accessibility are key considerations.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series MasterPact NT
Model NT12H1
Product Type Air Circuit Breaker (ACB)
Product Reference 47230
Rated Current 1250 A
Number of Poles 3P
Breaking Capacity Class H1
Ultimate Breaking Capacity (Icu) 42 kA at 440 V AC
Rated Operational Voltage Up to 690 V AC
Rated Frequency 50/60 Hz
Mounting Type Drawout
Configuration Basic frame
Trip Unit Not included
Control Unit Not included
Rated Insulation Voltage 1000 V AC
Rated Impulse Withstand Voltage 12 kV
Short-Time Withstand Current Up to 42 kA, depending on duration and configuration
Utilization Category Category B
Applicable Standard IEC 60947-2
Dimensions 322 × 288 × 277 mm
Weight 30 kg

Important: This specification describes the three-pole drawout basic-frame configuration. The compatible chassis and Micrologic trip unit must be selected separately.

Function and Working Principle

The Schneider NT12H1 is designed to protect electrical distribution circuits by interrupting current when abnormal electrical conditions occur. As an air circuit breaker, it uses air as the insulating medium around its switching and arc-interruption components.

1. Overload Protection

An overload occurs when an electrical circuit carries more current than its intended operating capacity for an extended period.

In a complete MasterPact NT installation, the compatible Micrologic trip unit monitors electrical conditions and provides the configured protection functions. When the measured current exceeds the selected protection threshold, the trip mechanism can initiate circuit interruption.

This helps protect cables, busbars, transformers, and connected electrical equipment from excessive thermal stress.

2. Short-Circuit Protection

A short circuit can produce extremely high current within a very short period. Without appropriate protection, this fault current may cause severe equipment damage, overheating, and electrical hazards.

The NT12H1 belongs to the H1 performance class, with a documented ultimate breaking capacity of 42 kA at 440 V AC.

The breaker is designed to interrupt fault currents within its specified ratings when correctly selected and installed in accordance with the manufacturer’s requirements.

3. Air Arc Interruption

When circuit-breaker contacts separate under load or fault conditions, an electrical arc can form between them.

The MasterPact NT uses an air-based arc-interruption arrangement to extinguish the arc and isolate the affected circuit. Its internal switching and arc-control structure is designed to manage the energy generated during interruption.

Correct installation, maintenance, and operation within the specified electrical ratings are essential for reliable performance.

4. Isolation and Circuit Switching

The NT12H1 is suitable for isolation in accordance with IEC 60947-2 when installed in the appropriate configuration.

It can be used as part of a power distribution arrangement where operators need to control the connection and disconnection of major electrical circuits.

Isolation procedures must always follow the equipment manufacturer’s instructions and applicable electrical safety regulations.

5. Drawout Mechanism

The drawout design allows the breaker to move between defined operating positions within its compatible chassis.

This arrangement supports maintenance and inspection by providing a means to withdraw the breaker from its connected position. It can also simplify replacement work in large distribution panels.

The correct chassis and mechanical interlocking accessories must be used to ensure safe operation.

Role in Industrial Power Distribution Systems

The NT12H1 is generally installed in the main or secondary distribution section of a low-voltage electrical system.

Its main purpose is to provide switching and protection for high-current circuits while allowing the electrical distribution network to be organized into manageable sections.

Main Distribution Protection

In an industrial facility, the main distribution board receives electrical power from a transformer, generator, or another upstream source.

The NT12H1 can be incorporated into an appropriately engineered distribution arrangement to protect a major outgoing feeder or distribution section.

Its 1250 A current rating makes it suitable for installations with substantial electrical loads, provided the actual load and protection requirements are within the complete breaker’s ratings.

Transformer Feeder Protection

Transformers supply electrical power to downstream distribution systems. The outgoing circuits require appropriate protection against overloads and short circuits.

A correctly selected MasterPact NT circuit breaker can form part of a transformer protection arrangement.

Protection coordination must consider transformer ratings, cable capacity, fault levels, and upstream and downstream protective devices.

Generator Distribution

Industrial generators are commonly connected to distribution systems through dedicated switching and protection equipment.

The NT12H1 may be used in suitable generator distribution applications when its voltage, current, interrupting capacity, and protection characteristics match the generator system.

Generator protection requires additional engineering consideration because generator fault-current characteristics differ from those of utility-fed systems.

Power Distribution Coordination

Large facilities often divide their electrical networks into multiple distribution sections.

A properly configured air circuit breaker helps isolate a faulted section while allowing unaffected parts of the system to continue operating where the protection coordination design permits.

The complete protection arrangement depends on the selected trip unit, settings, and coordination with other protective devices.

Industrial Applications

The Schneider NT12H1 is intended for high-current power distribution applications rather than small branch circuits.

1. Industrial Manufacturing Plants

Manufacturing facilities use large electrical distribution systems to supply production lines, motors, control panels, and auxiliary equipment.

The NT12H1 can be installed in a suitable main or sub-distribution switchboard to provide protection and switching for high-current feeders.

2. Data Centers

Data centers require reliable electrical distribution to support servers, cooling systems, UPS equipment, and other critical infrastructure.

Air circuit breakers can be used in main distribution and feeder arrangements where their electrical ratings and protection characteristics meet the system design.

The NT12H1 may be considered for appropriately rated distribution sections, subject to short-circuit studies and protection coordination.

3. Power Generation Facilities

Power generation installations use circuit breakers to manage connections between generators, transformers, and distribution networks.

The NT12H1 can form part of a suitable low-voltage distribution arrangement when the electrical system’s operating conditions fall within its ratings.

4. Commercial Buildings

Large commercial buildings often require high-capacity electrical distribution systems for HVAC equipment, elevators, lighting, and other building services.

A MasterPact NT circuit breaker can help protect major distribution feeders in appropriately designed switchboards.

5. Infrastructure and Utility Facilities

Water treatment plants, transportation infrastructure, and utility facilities depend on stable electrical distribution for pumps, motors, control systems, and auxiliary equipment.

The NT12H1 can be used in suitable low-voltage distribution panels where a 1250 A breaker with the required interruption capability is specified.

Installation and System Integration

Correct installation is essential for the electrical and mechanical performance of the NT12H1.

1. Verify the Electrical Ratings

Before installation, confirm that the electrical system is compatible with the breaker.

Important parameters include:

  • Rated system voltage.
  • Rated operating current.
  • Available short-circuit current.
  • Required breaking capacity.
  • System frequency.
  • Number of poles.
  • Protection coordination requirements.

The 1250 A rating and 42 kA H1 performance class must be evaluated against the actual installation conditions.

2. Select the Correct Micrologic Trip Unit

The specified 47230 configuration is a basic frame supplied without a trip unit.

A compatible Micrologic control unit must be selected separately according to the required protection functions.

Depending on the selected unit, available functions may include long-time, short-time, instantaneous, and ground-fault protection, together with measurement or communication capabilities.

The selected trip unit must be compatible with the NT12H1 frame and the intended application.

3. Install the Compatible Chassis

The drawout breaker requires the corresponding chassis.

The chassis provides the mechanical mounting and electrical connection interface for the breaker. It also supports the defined connected, test, and disconnected positions where provided by the complete assembly.

Verify the exact chassis reference and mechanical compatibility before installation.

4. Busbar and Cable Connections

The breaker must be connected using appropriately rated conductors and busbars.

Connection design should account for:

  • Rated current and temperature rise.
  • Short-circuit withstand capability.
  • Electrical clearance and insulation.
  • Mechanical support.
  • Terminal and connection arrangements.
  • Applicable installation standards.

All connections should be tightened according to the manufacturer’s specified torque values.

5. Protection Coordination

The trip-unit settings should be coordinated with upstream and downstream protective devices.

Proper coordination helps reduce unnecessary interruption of unaffected circuits and supports selective fault isolation.

Protection settings must be determined through an appropriate electrical engineering assessment rather than copied from another installation.

6. Commissioning and Functional Testing

Before energizing the breaker, verify the mechanical installation, chassis alignment, electrical connections, grounding, and trip-unit configuration.

Functional checks should include the operating mechanism, interlocks, indication systems, and protection functions.

Commissioning should be performed by qualified personnel using the applicable Schneider Electric procedures.

Compatible System Components

The NT12H1 drawout basic frame requires additional components to form a complete operating circuit-breaker assembly.

Component Function Integration Considerations
Micrologic Trip Unit Provides electronic protection and monitoring Must be compatible with the NT12H1 frame
Drawout Chassis Supports the breaker and its operating positions Select the correct chassis reference
Main Busbar System Distributes electrical power Must meet current and short-circuit ratings
Auxiliary Contacts Provide breaker status signals Confirm contact configuration and ratings
Shunt Trip Enables electrical remote tripping Verify coil voltage and accessory compatibility
Undervoltage Release Trips or prevents closing under specified voltage conditions Select the correct operating voltage
Closing Release Supports electrical closing operation Verify compatibility and control voltage
Spring-Charging Motor Charges the operating mechanism Confirm accessory requirements
Switchboard Provides mounting and electrical distribution Check dimensions, clearances, and fault withstand ratings
PLC or Power Monitoring System Monitors system status and coordinates operations Requires suitable trip-unit or accessory interfaces

These components are not necessarily included with the basic-frame product. Confirm the complete bill of materials before purchasing.

Alternative Models and Replacement Considerations

When replacing or upgrading an NT12H1, electrical and mechanical compatibility must be checked carefully.

Alternative Model or Series Description Replacement Considerations
MasterPact NT12H1 3P Fixed Fixed-mounted NT12H1 configuration Requires a different mounting arrangement
MasterPact NT12H1 4P Four-pole version Suitable only where the system requires four-pole switching
MasterPact NT12H2 Related NT12 high-performance version Different short-circuit performance class
MasterPact NT16 Higher-current NT frame Requires electrical and physical compatibility assessment
MasterPact NW Series Larger MasterPact air circuit breaker family Not a direct mechanical replacement

Before selecting an alternative, compare rated current, voltage, breaking capacity, pole configuration, mounting type, chassis, trip-unit compatibility, and accessory arrangement.

A breaker with the same rated current is not necessarily a suitable replacement. The switchboard’s short-circuit rating and protection coordination must also be reviewed.

Key Advantages

High Current Capacity

The 1250 A rated current makes the NT12H1 suitable for appropriately designed high-current power distribution systems.

Short-Circuit Interruption Capability

Its H1 performance class provides a documented 42 kA ultimate breaking capacity at 440 V AC.

Drawout Construction

The drawout arrangement supports inspection, maintenance, and replacement activities by allowing the breaker to be withdrawn from its compatible chassis.

Modular Protection Configuration

The basic frame can be combined with a compatible Micrologic trip unit selected according to the installation’s protection and monitoring requirements.

Industrial Power Distribution Application

The MasterPact NT family is designed for low-voltage distribution applications in industrial and commercial environments.

Isolation Capability

The breaker is suitable for isolation under the applicable IEC 60947-2 requirements when installed in the correct configuration.

Technical FAQs

1. What is the Schneider NT12H1?

The NT12H1 is a MasterPact NT air circuit breaker designed for low-voltage power distribution protection. The configuration covered here is a 1250 A, three-pole, drawout basic frame without a trip unit.

2. What is the rated current?

The rated current is 1250 A at the specified reference temperature of 40°C.

3. What is the breaking capacity of the NT12H1?

The H1 version has an ultimate short-circuit breaking capacity of 42 kA at 440 V AC. The actual suitability must be checked against the system’s prospective fault current.

4. Does this model include a Micrologic trip unit?

No. The 47230 basic-frame configuration is supplied without a trip unit. A compatible Micrologic unit must be ordered separately.

5. Does the NT12H1 require a chassis?

Yes. The drawout configuration requires the corresponding chassis for mounting and electrical connection.

6. What is the difference between fixed and drawout versions?

A fixed breaker is installed directly in its mounting arrangement. A drawout breaker is installed in a compatible chassis and can be moved between defined operating positions, supporting maintenance and replacement operations.

7. Can the NT12H1 be used in a 690 V AC system?

Its documented rated operational voltage extends up to 690 V AC. However, the applicable breaking capacity and installation conditions must be checked at the actual operating voltage.

8. What standards does the breaker follow?

The product is designed according to IEC 60947-2 requirements for low-voltage circuit breakers.

9. What should be checked before purchasing?

Confirm the complete reference, pole configuration, drawout or fixed mounting type, rated current, breaking capacity, trip-unit requirements, chassis compatibility, and accessory configuration.

10. Is the NT12H1 suitable for generator protection?

It may be used in an appropriately engineered generator distribution arrangement. The generator’s fault-current characteristics, voltage, current rating, and protection coordination must be evaluated before selection.

Procurement and Maintenance Recommendations

When purchasing the Schneider NT12H1, buyers should first confirm whether they require a complete operating circuit breaker or only the basic frame.

The 47230 configuration is a three-pole drawout basic frame without a trip unit. It must be combined with the correct chassis and a compatible Micrologic control unit before it can function as a complete protected circuit breaker.

For replacement projects, compare the existing equipment’s nameplate and product reference. Confirm the rated current, pole configuration, H1 breaking capacity, mounting arrangement, and installed accessories.

For used or refurbished units, inspect the operating mechanism, contact condition, insulation components, drawout connections, and mechanical interlocks. Request appropriate test documentation where the breaker will be used in a critical distribution system.

During maintenance, follow the manufacturer’s inspection schedule. Check contact wear, connection tightness, mechanism operation, auxiliary contacts, trip-unit settings, and chassis condition.

Electrical maintenance and commissioning should be performed by qualified personnel. Always isolate the equipment and follow the applicable safety procedures before inspection or servicing.

Conclusion

The Schneider Electric NT12H1 MasterPact Air Circuit Breaker is a high-current protection device designed for industrial and commercial low-voltage power distribution systems. With a rated current of 1250 A and an H1 ultimate breaking capacity of 42 kA at 440 V AC, it is suitable for appropriately engineered distribution applications.

The 3-pole drawout configuration provides a practical arrangement for switchboard installation and maintenance. However, the basic frame does not include a Micrologic trip unit or the required chassis. Correct component selection and electrical compatibility verification are therefore essential when purchasing, installing, or replacing the NT12H1.