Product Overview The Emerson A0760GP Industrial Accelerometer is a vibration sensor used in machinery condition monitoring and predictive maintenance. It measures machine vibration and converts mechanic……
Emerson A0760GP Industrial Accelerometer
  • Emerson
  • A0760GP
  • Industrial Accelerometer
  • USA
  • 42.2 × 17.3 mm
  • 0.051 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 2

Our advantage

Emerson A0760GP Industrial Accelerometer

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Emerson A0760GP Industrial Accelerometer

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Emerson A0760GP Industrial Accelerometer

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Emerson A0760GP Industrial Accelerometer

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Emerson A0760GP Industrial Accelerometer is a vibration sensor used in machinery condition monitoring and predictive maintenance. It measures machine vibration and converts mechanical acceleration into an electrical signal that can be analyzed by compatible vibration monitoring instruments. Typical applications include monitoring bearing housings, motor casings, pump assemblies, fans and other rotating equipment where changes in vibration can indicate developing mechanical problems.

The A0760GP has a nominal sensitivity of 100 mV/g with a tolerance of ±5% and a measurement range of ±50 g. Its frequency response extends from 0.5 Hz to 10 kHz within ±3 dB, allowing it to capture vibration across a broad range of machinery operating conditions. The sensor’s multipoint calibration supports applications where measurement consistency is important, particularly when vibration readings from different machines or measurement locations need to be compared.

The accelerometer uses a top-mounted, two-pin MIL-C-5015 electrical connector and a 1/4-28 UNF-2B mounting thread. Its stainless-steel housing and welded hermetic sealing suit industrial monitoring environments where the sensor must withstand mechanical shock and temperature variation. When integrated into a condition-monitoring system, the A0760GP supplies vibration data for trend analysis, fault investigation and maintenance planning.


Technical Specifications

Parameter Specification
Manufacturer Emerson
Model / Part Number A0760GP
Product Type Industrial Accelerometer
Product Category Machinery Vibration Sensor
Measurement Principle Piezoelectric acceleration measurement
Sensitivity 100 mV/g (10.2 mV/m/s²), ±5%
Measurement Range ±50 g (±490 m/s²)
Frequency Range (±3 dB) 0.50 to 10,000 Hz
Mounted Resonant Frequency 25 kHz nominal
Amplitude Linearity ±1%
Transverse Sensitivity ≤7%
Excitation Voltage 18 to 28 V DC
Constant Current 2 to 20 mA
Output Impedance Less than 200 ohms
Output Bias 8 to 12 V DC
Electrical Noise Resolution 350 μg, 1 to 10 kHz
Operating Temperature -54 to 121°C
Shock Limit 5,000 g peak
Sealing Welded hermetic
Sensor Element Ceramic, shear type
Case Material Stainless steel
Connector Type Top-mounted MIL-C-5015, 2-pin
Mounting Thread 1/4-28 UNF-2B
Mounting Torque 2 to 5 lb-ft (2.7 to 6.8 Nm)
Case Isolation Greater than 10⁸ ohms
Dimensions 42.2 × 17.3 mm
Weight 0.051 kg

Product Features

  • High sensitivity accuracy: Provides 100 mV/g sensitivity with a ±5% tolerance for consistent vibration measurements.
  • Wide measurement range: Measures acceleration up to ±50 g for machinery vibration analysis.
  • Broad frequency response: Covers frequencies from 0.5 Hz to 10 kHz within the specified ±3 dB range.
  • Multipoint calibration: Supports repeatable measurements when comparing vibration levels across machines and inspection locations.
  • Ceramic shear sensing element: Converts mechanical acceleration into an electrical signal for compatible monitoring equipment.
  • Hermetically sealed housing: Uses welded sealing to protect the internal sensing assembly.
  • Industrial temperature capability: Operates across a specified temperature range of -54 to 121°C.
  • Standard mounting interface: Uses a 1/4-28 UNF-2B thread for attachment to a suitable machine surface.
  • Two-pin electrical connection: Provides a defined interface for compatible sensor cables and vibration analyzers.

Working Principle

The A0760GP uses a piezoelectric sensing element to detect acceleration. When the sensor experiences vibration, mechanical stress acts on the ceramic element and generates an electrical charge proportional to the applied acceleration. The sensor’s internal electronics convert this response into a usable voltage signal, with a nominal sensitivity of 100 mV/g.

During a vibration inspection, the sensor is mounted securely to a suitable point on the machine, such as a motor bearing housing or pump casing. The connected analyzer supplies the required constant-current excitation and measures the resulting signal. Vibration data can then be evaluated in the time domain or converted into a frequency spectrum to help identify changes associated with imbalance, misalignment, bearing deterioration or looseness.

For example, maintenance personnel may record vibration at the same bearing housing during successive inspections. If the overall vibration level increases or a new frequency component appears, the readings can prompt further investigation before the condition affects production. Consistent mounting, sensor orientation and measurement settings are essential when comparing readings over time.

The A0760GP’s frequency response supports a range of vibration measurements, but the sensor alone does not identify a mechanical fault. Diagnosis depends on the measured signal, operating speed, machine characteristics and the analysis capabilities of the connected monitoring equipment.


Role in a Machinery Condition Monitoring System

The A0760GP acts as the vibration measurement point in a machinery condition-monitoring arrangement. It captures acceleration at the selected machine location and sends an electrical signal to a compatible analyzer or monitoring instrument for processing.

Machine Vibration → A0760GP Accelerometer → Sensor Cable → Vibration Analyzer → Condition Assessment and Maintenance Planning

System Component Function Relationship to the A0760GP
A0760GP Accelerometer Measures machine acceleration Converts vibration into an electrical signal
Sensor Mounting Stud Secures the sensor to the machine Establishes the mechanical connection required for measurement
Two-Pin Sensor Cable Carries the sensor signal and excitation Connects the accelerometer to compatible equipment
Vibration Analyzer Measures and processes the signal Calculates vibration levels and frequency information
Data Collector Stores readings from inspection routes Supports repeatable condition-monitoring measurements
Online Monitoring System Collects continuous vibration data where configured Uses compatible sensor inputs to monitor machinery trends
Machinery Bearing Housing Provides a vibration measurement location Transfers local machine vibration to the sensor
Motor or Pump Assembly Contains rotating and supporting components Supplies the mechanical condition being monitored
Signal Processing Software Analyzes vibration measurements Helps identify abnormal trends and frequency components
Maintenance Management System Records inspection findings and work orders Uses condition information to support maintenance decisions

Industrial Applications

Application Typical Equipment Role of the A0760GP
Electric Motor Monitoring Industrial motors and motor-bearing housings Measures vibration associated with rotating machinery
Pump Condition Monitoring Process pumps and utility pumps Supports vibration trending for bearing and mechanical condition
Fan and Blower Monitoring Industrial ventilation and process-air equipment Captures vibration that may indicate imbalance or mechanical looseness
Compressor Monitoring Industrial rotating compressor assemblies Supplies vibration data for condition assessment
Gearbox Inspection Industrial gear drives and transmission housings Supports vibration measurements at selected inspection points
Manufacturing Equipment Production machinery with rotating assemblies Helps maintenance teams compare vibration trends over time
Power Generation Auxiliary motors, pumps and rotating plant equipment Supports condition-based inspection of mechanical equipment
Process Industries Chemical, water-treatment and general process machinery Provides vibration data for maintenance investigations
Predictive Maintenance Programs Scheduled machinery inspection routes Supports repeatable vibration measurements and trend analysis

Installation and Maintenance

  1. Verify the sensor identification: Confirm that the A0760GP model and its sensitivity specification match the intended measurement system.
  2. Select the measurement location: Choose a suitable point on the bearing housing or machine casing where vibration can be measured consistently.
  3. Prepare the mounting surface: Ensure the mounting point is clean, flat and suitable for the specified threaded connection.
  4. Check the mounting thread: Verify that the 1/4-28 UNF-2B interface matches the mounting stud or threaded feature used in the installation.
  5. Secure the accelerometer: Tighten the sensor according to the specified mounting torque and avoid damaging the housing or thread.
  6. Inspect the electrical connector: Check the two-pin MIL-C-5015 connector for contamination, corrosion or mechanical damage.
  7. Verify cable compatibility: Use a suitable sensor cable and confirm the connector arrangement and wiring before connection.
  8. Check analyzer excitation: Ensure the connected instrument supports the required 18–28 V DC excitation and 2–20 mA constant-current range.
  9. Configure measurement sensitivity: Set the analyzer to the appropriate sensor sensitivity and confirm that its input range accommodates the expected acceleration.
  10. Establish a baseline measurement: Record vibration under known operating conditions so future readings can be compared consistently.
  11. Inspect signal quality: Check for loose mounting, cable movement, electrical interference or abnormal readings that could affect the measurement.
  12. Record inspection results: Document the sensor location, operating conditions, vibration values and any changes observed during maintenance inspections.

Related Components

Component Function Relationship to the A0760GP
Two-Pin Sensor Cable Carries the vibration signal and excitation Connects the accelerometer to the measurement instrument
1/4-28 UNF Mounting Stud Provides a threaded mounting interface Secures the sensor to a suitable machine surface
Vibration Analyzer Measures and analyzes sensor output Converts the signal into vibration data
Portable Data Collector Stores readings from inspection routes Supports repeated measurements at defined locations
Online Vibration Monitoring Module Acquires sensor signals continuously where supported Integrates vibration measurements into an installed monitoring system
Sensor Signal Conditioner Provides compatible excitation or signal conditioning where required Matches the sensor output to the receiving equipment
Machinery Health Analysis Software Processes vibration measurements Supports trend analysis and fault investigation
Machine Bearing Housing Provides the sensor mounting location Transfers vibration from the rotating assembly to the accelerometer

Recommended Related Models

Model / Product Product Type Relationship Selection Consideration
Emerson A0760GP Industrial Accelerometer Main product Suitable where 100 mV/g sensitivity and the specified frequency response meet the measurement requirements
Emerson A0710GP General Purpose Accelerometer Related sensor with side-exit connector configuration Compare mounting arrangement, frequency response and installation clearance
Emerson A0322L5 Industrial Accelerometer Related top-exit vibration sensor Compare sensitivity tolerance, calibration requirements and application needs
Emerson A0322RA Industrial Accelerometer Related accelerometer with an armored cable configuration Consider where an integral cable and additional cable protection are required
Emerson A0322RI Industrial Accelerometer Related accelerometer with an integral cable Compare cable arrangement and available cable-length options
Emerson AMS 2140 Machinery Health Analyzer Compatible vibration measurement equipment category Verify sensor input and excitation compatibility for the intended measurement setup

Key Advantages

  • Measures vibration across a frequency range of 0.5 Hz to 10 kHz.
  • Provides 100 mV/g sensitivity with a ±5% tolerance.
  • Supports repeatable vibration measurements through multipoint calibration.
  • Uses a hermetically sealed stainless-steel housing.
  • Operates across a specified temperature range of -54 to 121°C.
  • Connects to compatible vibration analyzers using a two-pin interface.
  • Supports machinery condition monitoring and predictive maintenance workflows.

Technical FAQs

What makes the A0760GP suitable for comparative vibration measurements?

Its sensitivity tolerance is ±5%, and the sensor uses multipoint calibration. These characteristics help maintain measurement consistency when comparing readings across inspection points or over time, provided the mounting and measurement conditions remain consistent.

What excitation does the A0760GP require?

The sensor specification lists an excitation voltage of 18–28 V DC and a constant-current range of 2–20 mA. The connected analyzer or monitoring instrument must support a compatible sensor interface.

How does mounting affect the measured vibration signal?

Mounting quality affects how effectively machine vibration reaches the sensing element. A secure installation on a suitable surface helps preserve the intended frequency response, while loose mounting or an unsuitable contact surface can distort readings.

Can the A0760GP identify a bearing fault by itself?

No. The accelerometer measures vibration but does not independently classify mechanical faults. Bearing assessment requires analysis of the measured signal alongside machine speed, operating conditions and relevant vibration patterns.