Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The 330130-045-01-05 is a 3300 XL series proximity transducer extension cable designed for industrial machinery vibration and displacement monitoring systems.
It is used to connect a proximity probe to a proximitor (signal conditioning module), ensuring stable transmission of eddy-current signals used for shaft vibration, axial displacement, and machinery condition monitoring.
Model breakdown:
This model is widely applied in critical rotating equipment monitoring systems requiring enhanced mechanical protection and certified industrial compliance.
System structure:
This system provides high-accuracy non-contact measurement of rotating machinery vibration and shaft position.
The 330130-045-01-05 extension cable is engineered to:
It uses a triaxial shielded and armored cable structure, which significantly improves resistance to vibration, oil exposure, abrasion, and electromagnetic interference.
This makes it suitable for mission-critical machinery protection systems where both mechanical durability and signal accuracy are required.
| Parameter | Specification |
|---|---|
| Model | 330130-045-01-05 |
| Series | 3300 XL |
| Product Type | Extension Cable |
| Cable Length | 4.5 m |
| Cable Structure | Armored 75 Ω triaxial cable |
| Connector Type | Coaxial locking connector |
| Cable Protection | Armored + shielded |
| Certification | CSA / ATEX / IECEx |
| Signal Type | Eddy-current vibration/displacement signal |
| Impedance | 75 Ω |
| Capacitance | ~69.9 pF/m |
| Operating Temperature | -40°C to +85°C (typical industrial range) |
| EMI Shielding | High-performance triaxial shielding |
| Outer Diameter | ~5–8 mm |
| Bend Radius | ≥25–50 mm |
| Dielectric Strength | ~1500 V (typical industrial spec) |
| Dimensions | 16 × 16 × 12 cm |
| Weight | 0.323 kg – 2.0 kg (varies by packaging/vendor) |
The 330130-045-01-05 is widely used in:
It is especially suitable for high-vibration environments requiring both certification compliance and mechanical reinforcement.
Provides strong resistance against crushing, abrasion, and industrial wear.
Maintains accurate eddy-current signal transmission over 4.5 m distance.
Triaxial shielding reduces electromagnetic interference in industrial settings.
Supports CSA, ATEX, and IECEx approvals for regulated environments.
Works seamlessly with 3300 XL probes and proximitor modules.
Designed for continuous operation in harsh industrial environments.
| Model | Description | Key Difference |
|---|---|---|
| 330130-045-00-05 | Standard cable | No armored protection |
| 330130-045-10-05 | FluidLoc version | Improved sealing |
| 330130-045-11-05 | Armored FluidLoc | Balanced protection |
| 330130-040-01-05 | 4.0 m version | Shorter cable |
| 330130-080-01-05 | 8.0 m version | Extended reach |
| Model | Description | Key Parameters |
|---|---|---|
| 330101-00-08-10-02-00 | Proximity probe | High precision vibration sensing |
| 330180-51-00 | Proximitor sensor module | Signal conditioning unit |
| 330103-00-06-10-02-00 | Standard probe | General turbine monitoring |
| 330105-02-12-10-02-05 | High-temperature probe | Thermal resistance capability |
| 330500-00-20 | Velocity sensor | General vibration monitoring |
| Parameter | 330130-045-01-05 | 330130-045-00-05 | 330130-045-10-05 | 330130-040-01-05 | 330130-080-01-05 |
|---|---|---|---|---|---|
| Cable Length | 4.5 m | 4.5 m | 4.5 m | 4.0 m | 8.0 m |
| Cable Type | Armored | Standard | FluidLoc | Armored | Armored |
| Certification | Yes | Yes | Yes | Yes | Yes |
| Mechanical Protection | High | Medium | Medium | High | High |
| EMI Shielding | High | High | High | High | High |
| Impedance | 75 Ω | 75 Ω | 75 Ω | 75 Ω | 75 Ω |
| Temperature Range | -40~85°C | -40~85°C | -40~125°C | -40~85°C | -40~85°C |
| Dimensions | 16×16×12 cm | 16×16×12 cm | 26.3×5.8×2.8 cm | 16×16×12 cm | 32×6×3 cm |
| Weight (kg) | 0.32–2.0 | 0.2–1.5 | 0.15–0.45 | 0.3–1.2 | 0.6–1.8 |
A1: It connects the proximity probe to the monitoring system for vibration and displacement signal transmission.
A2: It indicates a cable length of 4.5 meters.
A3: It indicates an armored cable configuration with enhanced mechanical protection.
A4: It indicates agency approvals such as CSA, ATEX, and IECEx.
A5: It is used in turbines, compressors, pumps, and rotating machinery systems.
A6: It transmits eddy-current vibration and displacement signals.
A7: Yes, it is designed for certified industrial environments requiring explosion protection compliance.
A8: No calibration is required when used in a matched system.
A9: Power generation, oil & gas, petrochemical, and heavy industry.
A10: It is designed for long-term continuous operation under industrial conditions with minimal degradation.