The 330130-040-12-05 is a 3300 XL series proximity transducer extension cable designed for industrial rotating machinery monitoring systems.
It is used to connect the proximity probe to the monitoring module (proximitor), ensuring stable transmission of eddy-current signals for vibration, shaft displacement, and position measurement.
Model structure meaning:
This model is widely used in critical industrial environments requiring explosion protection, sealing reliability, and high measurement stability.
System structure includes:
This system is designed for high-precision non-contact monitoring of rotating machinery conditions.
The 330130-040-12-05 extension cable is engineered to:
The FluidLoc + connector protector design (12) improves sealing and prevents fluid ingress, while the (05) certification ensures compliance for hazardous industrial environments such as oil & gas and chemical plants.
It is widely applied in mission-critical turbomachinery monitoring systems where downtime is costly and signal stability is essential.
| Parameter | Specification |
|---|---|
| Model | 330130-040-12-05 |
| Series | 3300 XL |
| Product Type | Extension Cable |
| Cable Length | 4.0 m |
| Cable Structure | 75 Ω triaxial cable |
| Connector Type | Coaxial locking connector |
| Cable Design | FluidLoc with connector protectors |
| Certification | CSA / ATEX / IECEx |
| Impedance | 75 Ω |
| Capacitance | 69.9 pF/m |
| Signal Type | Eddy-current vibration/displacement signal |
| Operating Temperature | -51°C to +177°C (system-rated range) |
| EMI Shielding | High-density triaxial shielding |
| Bend Radius | ≥25–50 mm |
| Outer Diameter | ~5–7 mm |
| Electrical Resistance | 0.88 Ω (core) / 0.26 Ω (shield) |
| Cable Type | Armored / sealed industrial grade |
| Dimensions | 26.3 × 5.8 × 2.8 cm |
| Weight | 0.034 kg (raw cable reference) / ~0.2–1.1 kg installed assembly |
The 330130-040-12-05 is widely used in:
It is especially suitable for hazardous industrial zones requiring certified instrumentation and stable signal transmission.
Supports CSA, ATEX, and IECEx standards for safety-critical environments.
Prevents oil and moisture ingress into connector and cable body.
Ensures stable eddy-current signal transmission without distortion.
Triaxial shielding reduces electromagnetic interference in industrial environments.
Designed for continuous operation under vibration, heat, and contamination.
Prevents accidental disconnection in high-vibration machinery.
| Model | Description | Key Difference |
|---|---|---|
| 330130-040-11-05 | Armored FluidLoc cable | Higher mechanical protection |
| 330130-040-10-05 | Standard FluidLoc cable | Non-armored design |
| 330130-040-03-05 | Armored cable version | Mechanical protection focused |
| 330130-040-02-05 | Basic certified cable | General industrial use |
| 330130-080-12-05 | 8.0 m FluidLoc cable | Extended distance |
| Model | Description | Key Parameters |
|---|---|---|
| 330101-00-08-10-02-00 | Proximity probe | High-resolution vibration measurement |
| 330180-51-00 | Proximitor sensor module | Signal conditioning unit |
| 330103-00-06-10-02-00 | Standard probe | General turbine monitoring |
| 330105-02-12-10-02-05 | High-temperature probe | High thermal resistance |
| 330500-00-20 | Velocity sensor | Machinery vibration monitoring |
| Parameter | 330130-040-12-05 | 330130-040-11-05 | 330130-040-10-05 | 330130-040-03-05 | 330130-080-12-05 |
|---|---|---|---|---|---|
| Cable Length | 4.0 m | 4.0 m | 4.0 m | 4.0 m | 8.0 m |
| Cable Type | FluidLoc + protector | Armored FluidLoc | FluidLoc | Armored | FluidLoc |
| Certification | CSA / ATEX / IECEx | Yes | Yes | Yes | Yes |
| Hazardous Area Use | Yes | Yes | Yes | Yes | Yes |
| Oil Resistance | High | High | High | Medium | High |
| Mechanical Protection | Medium | High | Medium | High | Medium |
| Impedance | 75 Ω | 75 Ω | 75 Ω | 75 Ω | 75 Ω |
| Temperature Range | -51~177°C | -40~100°C | -40~125°C | -40~125°C | -51~177°C |
| EMI Shielding | High | High | High | High | High |
| Weight (kg) | 0.034–1.1 | 0.45–1.1 | 0.15–0.45 | 0.45–1.1 | 0.6–1.5 |
A1: It connects the proximity probe to the monitoring system for vibration and displacement signal transmission.
A2: It indicates a 4.0-meter cable length.
A3: It indicates FluidLoc cable with connector protectors for improved sealing performance.
A4: It indicates hazardous area certification including CSA, ATEX, and IECEx approvals.
A5: It is used in turbines, compressors, pumps, and industrial rotating machinery systems.
A6: It carries eddy-current vibration and displacement signals.
A7: Yes, it is certified for hazardous area installations.
A8: No calibration is required when used within matched system components.
A9: Power generation, oil & gas, petrochemical, and heavy industry.
A10: It is designed for long-term continuous industrial operation under harsh conditions.