• Allen Bradley 1756-CFM ControlLogix Configurable Flow Meter Module
  • Allen Bradley 1756-CFM ControlLogix Configurable Flow Meter Module
  • Allen Bradley 1756-CFM ControlLogix Configurable Flow Meter Module
  • Allen Bradley 1756-CFM ControlLogix Configurable Flow Meter Module
Product Overview The Allen-Bradley 1756-CFM ControlLogix Configurable Flowmeter Module is a specialized input/output module designed for high-speed flow measurement and process control in Rockwell Autom……
Allen Bradley 1756-CFM ControlLogix Configurable Flow Meter Module
  • Allen Bradley
  • 1756-CFM
  • ControlLogix Configurable Flow Meter Module
  • USA
  • 144.5 × 34.6 × 130.18 mm
  • 0.4 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 1

Our advantage

Allen Bradley 1756-CFM ControlLogix Configurable Flow Meter Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 1756-CFM ControlLogix Configurable Flow Meter Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 1756-CFM ControlLogix Configurable Flow Meter Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 1756-CFM ControlLogix Configurable Flow Meter Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Allen-Bradley 1756-CFM ControlLogix Configurable Flowmeter Module is a specialized input/output module designed for high-speed flow measurement and process control in Rockwell Automation ControlLogix systems. It provides an interface between a Logix controller and external flowmeter devices, allowing pulse-based flow signals to be measured, processed, and used in industrial control applications.

Unlike conventional digital input modules, the 1756-CFM is specifically designed to handle flowmeter signals and perform dedicated measurement functions. It supports two configurable flowmeter channels, two gate inputs for totalizer-related operations, and two current-sourcing outputs. This configuration allows the module to perform flow measurement and associated control functions without requiring all high-speed signal processing to be handled by the main controller.

The module accepts signals from several types of flowmeter equipment, including magnetic pickups, TTL-compatible devices, and preamplifier outputs. Its input configuration can be adjusted to match the electrical characteristics of the connected instruments. With a maximum flowmeter input frequency of 100 kHz, it is suitable for applications that require fast pulse acquisition and accurate frequency measurement.

The 1756-CFM supports operating modes that include totalizer and high-resolution frequency measurement. These functions make it useful in applications involving liquid measurement, batch filling, flowmeter proving, and process monitoring. Its configurable outputs can respond to selected measurement conditions, allowing external equipment to receive control signals based on flow-related events.

Designed for installation in a compatible ControlLogix chassis, the 1756-CFM communicates with the Logix controller through the system backplane. Its single-slot design makes it possible to add specialized flow measurement functionality to an existing modular automation architecture.

Technical Specifications

Parameter Specification
Brand Allen-Bradley
Manufacturer Rockwell Automation
Model 1756-CFM
Product Series ControlLogix 1756
Product Type Configurable Flowmeter Module
Module Function High-Speed Flow Measurement and Control
Flowmeter Channels 2
Gate Inputs 2
Total Input Points 4
Configurable Outputs 2 current-sourcing outputs
Supported Input Signals Magnetic pickup, TTL, preamplifier
Maximum Input Frequency 100 kHz
Frequency Resolution 0.0005 Hz
Flowmeter Input Impedance 5 kΩ ±30%
Flowmeter Input Voltage Up to ±30 V peak
Selectable Input Thresholds 50 mV, 1.3 V, and 4 V
Output Voltage 10–31.2 V DC or 4.5–5.5 V DC, depending on configuration
Maximum Output Current 1 A per output at 10–31.2 V DC
Total Output Current 2 A maximum
Backplane Current at 5.1 V DC 300 mA
Backplane Current at 24 V DC 16 mA for Series A; 25 mA for Series B
Maximum Power Dissipation 6 W for Series A; 3.12 W for Series B
Isolation Voltage 250 V continuous
Mounting ControlLogix chassis
Slot Requirement 1 slot
Terminal Connection 20-pin removable terminal block
Operating Temperature 0 to 60°C
Relative Humidity 5–95%, non-condensing
Dimensions Provided 144.5 × 34.6 × 130.18 mm
Weight Provided 0.4 kg

Note: Some electrical characteristics differ between hardware revisions. Check the module’s series and revision before applying the specifications to an existing installation.

Function and Working Principle

The 1756-CFM processes pulse signals generated by flowmeters and converts them into measurement information that can be used by a ControlLogix controller. Its dedicated input circuitry and configurable operating modes allow it to perform high-speed measurement tasks within the automation system.

1. Flowmeter Signal Acquisition

The module provides two flowmeter inputs, identified as F0 and F1. Each channel can be configured for the signal type supplied by the connected measurement instrument.

Supported signal sources include:

  • Magnetic pickup devices.
  • TTL-compatible pulse outputs.
  • Powered preamplifier outputs.

Magnetic pickup sensors typically generate electrical pulses as a rotating target or toothed wheel passes the sensing element. TTL devices provide logic-level pulses, while preamplifiers may supply conditioned signals from industrial flow measurement equipment.

The 1756-CFM allows the input threshold to be selected according to the signal source. This helps the module recognize incoming pulses under different electrical conditions.

2. High-Speed Frequency Measurement

Flowmeters frequently generate pulse signals whose frequency is proportional to the flow rate. By measuring pulse frequency, the module can determine the rate at which fluid is moving through a process line.

The 1756-CFM supports flowmeter input frequencies up to 100 kHz. Its frequency measurement capability makes it suitable for applications where rapid changes in flow must be detected and processed.

The module also provides a frequency resolution of 0.0005 Hz. Actual measurement accuracy depends on the flowmeter, installation, signal quality, configuration, and operating conditions.

3. Totalizer Operation

Totalizer operation is used to calculate the accumulated quantity of fluid passing through a flowmeter over a period of time.

The module processes incoming pulses and maintains a running count. The controller can use this information to monitor cumulative flow, manage production quantities, or determine when a predefined batch volume has been reached.

This function is particularly useful in applications where a process requires accurate tracking of material consumption or liquid transfer.

4. Gate Input Processing

The 1756-CFM provides two gate inputs, Z0 and Z1. These inputs are used in totalizer-related applications, including flowmeter proving and controlled counting operations.

Gate signals can be used to define when counting should begin or end. For example, an external contact or control signal may indicate the start of a measurement interval.

The gate inputs support the coordination of measurement activity with external process equipment.

5. Configurable Output Control

Two current-sourcing outputs are available for fast-response control functions. These outputs can be assigned to selected flowmeter channels and configured to respond to user-defined trigger conditions.

Depending on the operating mode, output functions may include frequency-related events, acceleration conditions, prover status, and fill control.

Each output supports up to 1 A at the specified 10–31.2 V DC operating range, subject to the module’s total output-current limit. An external power supply is required for the outputs.

These configurable outputs allow the module to respond to flow-related conditions without relying exclusively on slower controller scan-based processing.

Role in Industrial Control Systems

The 1756-CFM is designed to extend the measurement capabilities of a ControlLogix automation system. It performs specialized flowmeter processing while exchanging data with the Logix controller through the chassis backplane.

Integration with ControlLogix Controllers

The module operates as a single-slot component in a compatible ControlLogix chassis. The controller receives measurement and status information from the module and can use this data within the application program.

For example, a PLC program may monitor the measured flow rate, compare accumulated volume with a production target, and coordinate valves or pumps according to the process sequence.

This arrangement separates high-speed flowmeter signal processing from the main control logic.

Integration with Flow Measurement Instruments

The module can interface with compatible magnetic pickups, TTL pulse devices, and preamplifier outputs.

This flexibility makes it suitable for different flowmeter technologies. However, the electrical characteristics of the instrument must be checked before connection. Signal amplitude, pulse frequency, wiring, shielding, and grounding all affect measurement reliability.

Coordination with Valves and Pumps

The 1756-CFM can provide measurement information and configurable output signals that support process equipment coordination.

For example, a filling system may use accumulated flow to determine when a target quantity has been reached. The control system can then issue a command to close a valve or stop a pump.

The actual valve and pump commands are normally handled by the broader PLC control strategy and associated output devices.

Monitoring and Diagnostics

The module includes status indicators that help maintenance personnel check input, output, and module operating conditions.

These indicators can assist with troubleshooting signal wiring, missing pulses, incorrect input configuration, and output operation. The controller can also use module status information as part of its diagnostic strategy.

Industrial Applications

The 1756-CFM is suitable for industrial processes that require pulse-based flow measurement and associated control functions.

1. Oil and Gas Processing

Flow measurement is important in oil and gas production, transfer, and processing systems. Compatible flowmeters can provide pulse signals to the 1756-CFM for flow-rate monitoring and totalized measurement.

The module’s totalizer and high-speed frequency capabilities can support measurement systems where flow information is used by a centralized ControlLogix controller.

Application suitability depends on the instrumentation, hazardous-area design, signal conditioning, and applicable measurement standards.

2. Chemical Processing

Chemical production often requires controlled transfer of liquids between tanks, reactors, and process lines.

The 1756-CFM can receive pulse signals from compatible flowmeters and provide measurement data for batch control and process monitoring.

The controller can use accumulated flow information to coordinate pumps, valves, and other equipment. Instrument selection must account for fluid properties, chemical compatibility, and required measurement performance.

3. Water and Wastewater Treatment

Water treatment systems use flow measurement to monitor supply lines, dosing processes, circulation loops, and discharge operations.

A ControlLogix system equipped with the 1756-CFM can process compatible flowmeter signals and use the resulting information for monitoring and control.

The module can support totalized volume measurement and flow-related output actions when configured for the application.

4. Batch Filling Systems

Batch filling requires a defined quantity of liquid or other measurable material to be delivered during each production cycle.

The 1756-CFM can accumulate flowmeter pulses and support fill-control operations based on configured measurement conditions.

When the target quantity is reached, the system can initiate a control action through the configured output or PLC program. Proper valve response, pipeline dynamics, and flowmeter calibration are important for achieving the required filling accuracy.

5. Food and Beverage Production

Food and beverage facilities use flow measurement in ingredient transfer, liquid blending, cleaning processes, and product filling.

The 1756-CFM can provide pulse-based measurement information for compatible flowmeters in a ControlLogix system.

For hygienic applications, the flowmeter and process connections must meet the facility’s sanitary requirements. The module itself is installed in the control cabinet rather than in direct contact with the process fluid.

6. Flowmeter Calibration and Proving

Flowmeter proving compares the output of a meter under test with a known reference or proving arrangement.

The 1756-CFM includes gate inputs and totalizer-related functions that can support flowmeter proving applications. These functions allow measurement counting to be coordinated with external proving signals.

The complete proving system must be designed and calibrated according to the applicable measurement procedures.

Installation and System Integration

Correct installation is essential for reliable pulse acquisition, accurate measurement, and stable communication with the ControlLogix controller.

1. Verify Chassis Compatibility

The 1756-CFM is a single-slot ControlLogix module. Before installation, confirm that the chassis has an available slot and that the controller configuration supports the module.

Check the module’s hardware series, firmware requirements, and applicable Add-On Profile or configuration software before commissioning.

2. Select the Correct Removable Terminal Block

The module uses a 20-pin removable terminal block arrangement. Confirm that the selected terminal block and housing are compatible with the module and the required wiring method.

The terminal block must be correctly seated and secured before the system is powered or returned to operation.

3. Connect Flowmeter Signals

Connect the flowmeter signal conductors to the appropriate F0 and F1 input terminals. The input configuration must match the sensor output type.

For magnetic pickups, TTL signals, and preamplifier outputs, use the appropriate threshold settings. Incorrect signal selection may result in missed pulses, unstable readings, or inaccurate measurements.

4. Configure Gate Inputs

Where totalizer or prover functions are required, connect the external gate signals to the appropriate Z0 and Z1 inputs.

Verify the gate voltage range, signal polarity, wiring arrangement, and input configuration. Ensure that the gate signal timing is appropriate for the measurement process.

5. Wire the Configurable Outputs

The two outputs are current-sourcing and require an external power supply. Check the voltage and current requirements of the connected devices before wiring.

Each output can support up to 1 A under the specified operating conditions, while the total output current is limited to 2 A. Do not exceed these limits.

6. Configure the Module in the Controller

After installation, configure the module in the ControlLogix project. Select the required operating mode, input signal settings, filter parameters, measurement conditions, and output trigger functions.

The configured parameters must match the physical instrumentation and the intended process operation.

7. Test and Commission

Before placing the system into normal service:

  • Verify the module’s seating and terminal connections.
  • Confirm the correct input signal type and threshold.
  • Check that flowmeter pulses are being detected.
  • Compare frequency readings with an appropriate reference.
  • Verify totalizer counting and gate input operation.
  • Test configured output responses.
  • Confirm controller communication and module status.
  • Record the final configuration for maintenance purposes.

Compatible System Components

The 1756-CFM is designed to work with a range of ControlLogix hardware and external flow measurement devices.

Component Function Integration Considerations
ControlLogix controller Executes process logic and receives measurement data Confirm controller and software compatibility
ControlLogix chassis Provides mounting and backplane communication Requires one available slot
ControlLogix power supply Supplies chassis backplane power Verify chassis power capacity
20-pin removable terminal block Provides field wiring connections Confirm the correct terminal block and housing
Magnetic pickup flowmeter Generates pulses related to flow Configure the appropriate input threshold
TTL pulse source Provides logic-level flow pulses Verify signal voltage and polarity
Preamplifier output Supplies conditioned flowmeter signals Confirm output voltage and electrical compatibility
External DC power supply Supplies the configurable outputs Match output voltage and load-current requirements
PLC digital output module Controls valves, pumps, or auxiliary devices Select according to load and control design
HMI Displays flow rate, accumulated volume, and alarms Communicates through the controller or system network

The actual system configuration depends on the application. Not every component listed above is supplied with the 1756-CFM module.

Alternative Models and Replacement Considerations

When replacing a 1756-CFM, the replacement must provide the flow measurement functions and electrical interfaces required by the existing application.

Alternative or Related Product Consideration
Allen-Bradley 1756-CFMK Related ControlLogix configurable flowmeter module with conformal coating; verify the exact environmental and configuration requirements
Allen-Bradley 1756 high-speed counter modules May be considered for pulse-counting applications, but dedicated flowmeter functions may differ
Allen-Bradley 1756 digital input modules Suitable for general digital signals, not necessarily for high-speed flowmeter measurement
External flow measurement instruments May provide alternative measurement or signal-conditioning arrangements, subject to system redesign
Other ControlLogix specialty I/O modules Must be evaluated for input frequency, signal compatibility, measurement modes, and controller integration

Before selecting a replacement, compare:

  • Number of flowmeter channels.
  • Number and function of gate inputs.
  • Maximum input frequency.
  • Input signal types and voltage thresholds.
  • Frequency resolution and measurement behavior.
  • Totalizer and prover functionality.
  • Number and electrical ratings of outputs.
  • Hardware series and firmware compatibility.
  • Terminal block and field wiring arrangement.
  • Controller configuration and application logic.

A general-purpose digital input module should not be treated as a direct replacement for the 1756-CFM unless the complete measurement function can be reproduced by an approved system design.

Key Advantages

Dedicated Flow Measurement

The 1756-CFM is designed specifically for pulse-based flowmeter applications, providing measurement functions beyond those of standard digital input modules.

Two Configurable Flowmeter Channels

Two flowmeter inputs allow the module to process signals from two compatible measurement sources within one ControlLogix slot.

High-Speed Input Capability

The maximum input frequency of 100 kHz supports applications where rapid pulse acquisition is required.

Multiple Signal Types

Support for magnetic pickup, TTL, and preamplifier signals provides flexibility when integrating different flow measurement instruments.

Totalizer and Prover Functions

Dedicated measurement modes support accumulated volume calculations and flowmeter proving applications.

Configurable Outputs

Two current-sourcing outputs can respond to selected measurement conditions, supporting fast process-related control actions.

ControlLogix Integration

The module communicates through the ControlLogix backplane, allowing flow measurement data to be incorporated into existing Logix control programs.

Modular Installation

Its single-slot design allows specialized flowmeter functionality to be added to a compatible ControlLogix chassis without requiring a separate standalone controller.

Technical FAQs

1. What is the Allen-Bradley 1756-CFM used for?

The 1756-CFM is a ControlLogix configurable flowmeter module designed for high-speed flow measurement. It processes pulse signals from compatible flowmeters and supports functions such as frequency measurement, totalization, and flow-related control.

2. How many flowmeter channels does the 1756-CFM support?

It supports two flowmeter input channels, F0 and F1. It also provides two gate inputs, Z0 and Z1, for totalizer-related and prover applications.

3. What types of flowmeter signals can it accept?

The module supports magnetic pickup signals, TTL-compatible signals, and preamplifier outputs. The correct input threshold must be selected according to the connected instrument.

4. What is the maximum input frequency?

The maximum flowmeter input frequency is 100 kHz. The actual operating frequency must remain within the module’s specified limits.

5. Does the 1756-CFM support totalizer operation?

Yes. Its totalizer functionality accumulates incoming flowmeter pulses to calculate the total quantity measured over a defined period.

6. What are the gate inputs used for?

The Z0 and Z1 gate inputs accept external signals used to control counting intervals in totalizer-related applications, including flowmeter proving and measurement coordination.

7. How many outputs does the module provide?

It provides two configurable current-sourcing outputs. Each output can support up to 1 A at the specified 10–31.2 V DC operating range, subject to the module’s total output-current limit.

8. Does the 1756-CFM require an external power supply?

The module receives its operating power through the ControlLogix backplane. Its configurable outputs require an external power supply, which must be selected according to the connected load and output configuration.

9. Can the 1756-CFM be installed in any ControlLogix chassis?

It is designed for compatible ControlLogix chassis and occupies one slot. Check chassis compatibility, controller configuration, firmware, and module revision before installation.

10. What should be checked when replacing an existing 1756-CFM?

Verify the catalog number, hardware series, terminal block, flowmeter signal types, input thresholds, controller configuration, and output wiring. The replacement must also support the measurement modes and performance required by the application.

Procurement and Maintenance Recommendations

When purchasing the Allen-Bradley 1756-CFM, verify the complete catalog number and hardware revision. The module’s series can affect certain electrical specifications, so it is important to match the replacement to the installed ControlLogix configuration.

For used or refurbished equipment, inspect the front panel, terminal connections, circuit board condition where accessible, and module status indicators. Request clear product photographs and functional test information where possible.

Confirm whether the removable terminal block and housing are included. These accessories may be ordered separately, and the existing field wiring arrangement should be checked before installation.

For maintenance, inspect flowmeter wiring, shielding, grounding, terminal connections, and external power supplies. Monitor signal stability and compare measurement readings with appropriate reference instruments. Investigate missing pulses, inconsistent frequency readings, or unexpected totalizer behavior before changing the controller program.

Keep a backup of the ControlLogix project and document the module’s configuration, input thresholds, operating modes, and output assignments. This information can reduce commissioning time if the module needs to be replaced.

Conclusion

The Allen-Bradley 1756-CFM ControlLogix Configurable Flowmeter Module is a specialized automation component designed for high-speed pulse-based flow measurement and control. With two flowmeter channels, two gate inputs, two configurable outputs, and a maximum input frequency of 100 kHz, it supports applications involving flow monitoring, totalization, batch filling, and flowmeter proving.

Its integration with the ControlLogix platform allows measurement information to be incorporated into PLC-based process control. For maintenance and replacement projects, engineers should verify the hardware revision, signal characteristics, terminal arrangement, and controller configuration to ensure reliable operation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501