Product Overview
In modern low-voltage power distribution systems, reliable protection devices are essential for preventing equipment damage, improving electrical safety, and ensuring continuous operation. The ABB PR122/P-LSIG E1-E6 1SDA058198R1 Overcurrent Release is an advanced electronic protection unit designed for ABB SACE Emax air circuit breakers, providing accurate monitoring and protection against electrical faults.
The PR122/P-LSIG E1-E6 combines multiple protection functions, including overload protection, short-circuit protection, instantaneous fault protection, and earth fault protection. It is designed to continuously monitor electrical parameters and quickly initiate circuit breaker operation when abnormal conditions occur.
This overcurrent release is suitable for industrial power distribution systems, energy facilities, manufacturing plants, and large electrical installations requiring reliable protection and precise fault management.
The ABB PR122/P-LSIG E1-E6 is compatible with ABB SACE Emax circuit breaker systems, including E1, E2, E3, E4, and E6 frame sizes. It provides a flexible protection solution for different low-voltage power applications.
With dimensions of 155 × 95 × 70 mm and a weight of 1 kg, the ABB PR122/P-LSIG E1-E6 offers a compact design for integration into industrial circuit breaker assemblies.
Technical Specifications
| Parameter |
Details |
| Manufacturer |
ABB |
| Model |
PR122/P-LSIG E1-E6 |
| Article Number |
1SDA058198R1 |
| Product Type |
Overcurrent Release |
| Protection Type |
Electronic Protection Unit |
| Suitable Circuit Breaker |
ABB SACE Emax |
| Compatible Frame Size |
E1, E2, E3, E4, E6 |
| Protection Functions |
LSI + Ground Fault Protection |
| Standard |
IEC |
| Installation Method |
Circuit Breaker Mounted |
| Dimension |
155 × 95 × 70 mm |
| Weight |
1 kg |
Function and Working Principle
The ABB PR122/P-LSIG E1-E6 operates as an intelligent protection module installed within an air circuit breaker system.
During normal operation, the overcurrent release continuously measures electrical parameters such as current values and system conditions. When abnormal current levels are detected, the internal electronic protection logic evaluates the fault type and sends a trip command to the circuit breaker mechanism.
The basic working process includes:
- Monitoring electrical current conditions
- Detecting overload situations
- Identifying short-circuit faults
- Detecting earth fault conditions
- Processing protection algorithms
- Sending trip commands to the breaker
Main protection functions include:
- L – Long-time protection: Protects against overload conditions caused by excessive current over time.
- S – Short-time protection: Provides delayed short-circuit protection.
- I – Instantaneous protection: Provides rapid response to severe short-circuit faults.
- G – Ground fault protection: Detects abnormal current leakage to ground.
Role in Industrial Power Systems
The ABB PR122/P-LSIG E1-E6 plays an important role in industrial electrical protection systems.
It is commonly integrated with:
| System Component |
Function |
| Air Circuit Breaker |
Performs electrical isolation and switching |
| Power Distribution Panel |
Manages electrical supply |
| Current Sensors |
Provide current measurement signals |
| Protection System |
Analyzes electrical faults |
| Monitoring System |
Displays operating conditions |
| Industrial Loads |
Receives protected power supply |
By providing fast and accurate fault detection, the module helps reduce equipment damage, improve electrical safety, and maintain system reliability.
Industrial Applications
The ABB PR122/P-LSIG E1-E6 Overcurrent Release is widely used in industrial power distribution applications.
| Industry |
Application |
| Manufacturing Plants |
Main power protection |
| Power Generation |
Distribution system protection |
| Oil and Gas |
Electrical equipment protection |
| Petrochemical |
High-reliability power systems |
| Data Centers |
Critical power protection |
| Mining Industry |
Heavy electrical equipment protection |
| Infrastructure |
Low-voltage distribution systems |
| Commercial Buildings |
Main switchboard protection |
The module is suitable for installations where accurate fault detection and dependable circuit protection are required.
Installation and System Integration
Proper installation and configuration are important for achieving reliable protection performance.
Recommended installation procedures:
- Install the release unit into the compatible ABB Emax circuit breaker
- Connect required electrical interfaces
- Verify current sensing connections
- Configure protection parameters
- Test trip functions
- Perform system commissioning
During commissioning, engineers should verify:
- Correct installation position
- Protection setting values
- Current measurement accuracy
- Trip response performance
- Alarm indications
- Communication functions
Correct configuration ensures effective protection and minimizes unnecessary circuit interruptions.
Protection Functions and Settings
The ABB PR122/P-LSIG E1-E6 provides multiple adjustable protection functions.
| Protection Function |
Description |
| Long-Time Protection |
Prevents damage caused by overload currents |
| Short-Time Protection |
Protects against delayed short circuits |
| Instantaneous Protection |
Provides rapid fault clearing |
| Ground Fault Protection |
Detects earth leakage conditions |
| Diagnostic Function |
Supports system monitoring |
These protection features allow engineers to optimize electrical safety according to different application requirements.
Compatible Automation and Electrical Systems
The ABB PR122/P-LSIG E1-E6 can be integrated into various electrical distribution architectures.
| System |
Application |
| ABB SACE Emax Circuit Breakers |
Low-voltage protection |
| Industrial Switchgear Systems |
Power distribution |
| Electrical Control Panels |
Equipment protection |
| Energy Management Systems |
Electrical monitoring |
| Industrial Automation Facilities |
Power reliability management |
Recommended Alternative Models
| Model |
Type |
Key Feature |
Application |
| ABB PR122/P-LSIG E1-E6 |
Overcurrent Release |
Advanced LSI + Ground Fault Protection |
Industrial power protection |
| ABB PR121/P |
Protection Release |
Basic electronic protection |
Standard circuit breakers |
| ABB PR123/P |
Advanced Protection Release |
Extended protection functions |
Complex power systems |
| ABB PR331/P |
Electronic Trip Unit |
Industrial breaker protection |
Distribution applications |
Key Advantages
- Advanced electronic overcurrent protection
- Supports overload and short-circuit protection
- Provides ground fault protection
- Compatible with ABB SACE Emax breakers
- Fast fault response capability
- Improves electrical system safety
- Compact industrial design
- Reliable operation in demanding environments
- Easy integration into low-voltage switchgear systems
Technical FAQs
What is the ABB PR122/P-LSIG E1-E6 used for?
The ABB PR122/P-LSIG E1-E6 is an electronic overcurrent release used for protecting ABB SACE Emax circuit breakers against overloads, short circuits, and ground faults.
What is the article number of ABB PR122/P-LSIG E1-E6?
The article number is 1SDA058198R1.
Which circuit breakers are compatible with the PR122/P-LSIG E1-E6?
The module is compatible with ABB SACE Emax circuit breakers including E1, E2, E3, E4, and E6 frame sizes.
What are the dimensions of the ABB PR122/P-LSIG E1-E6?
The dimensions are 155 × 95 × 70 mm.
What is the weight of the ABB PR122/P-LSIG E1-E6?
The total weight is 1 kg.
Conclusion
The ABB PR122/P-LSIG E1-E6 1SDA058198R1 Overcurrent Release is a reliable electronic protection solution designed for ABB SACE Emax low-voltage circuit breaker systems.
With advanced LSI and ground fault protection functions, accurate fault detection capability, and compact industrial design, the PR122/P-LSIG E1-E6 helps improve electrical safety, reduce equipment risks, and maintain stable power distribution performance.
For electrical engineers, automation professionals, and maintenance teams, the ABB PR122/P-LSIG E1-E6 provides an effective protection solution for modern industrial power systems.