The ABB DI880 (3BSE028586R1) is a high-performance digital input module designed for the S800 I/O system. It provides 16 channels of 24 V DC digital input with sourcing inputs and integrated short-circuit and open-circuit detection. Each channel delivers fast 1 ms response and 2 ms Sequence of Events (SOE) timestamp resolution. Encased in a slim housing measuring 45 × 102 × 119 mm and weighing 0.15 kg, the DI880 mounts on standard DIN rails and connects directly to ABB’s modular backplane, making it ideal for diagnostics-intensive installations.
Parameter | Specification |
---|---|
Model Number | DI880 (3BSE028586R1) |
Module Type | Digital Input Module |
Number of Input Channels | 16 |
Input Voltage Range | 20 to 30 V DC |
Input Signal Type | Sourcing (positive logic) |
Input Impedance | 2.2 kΩ |
Isolation | Optical per channel |
Short-Circuit Detection | Yes |
Open-Circuit Detection | Yes |
Response Time | ≤ 1 ms |
SOE Timestamp Resolution | 2 ms |
Power Dissipation | 3 W |
Dimensions (WxHxD) | 45 × 102 × 119 mm |
Weight | 0.15 kg |
Operating Temperature | –25 °C to +60 °C |
Mounting | DIN rail |
Communication Interface | ABB S800 backplane |
Series | S800 I/O |
Brand | ABB |
The DI880 module excels in applications requiring detailed diagnostics and event logging:
Power Plants: Monitoring turbine interlocks, breaker statuses, and protective relays.
Oil & Gas: Capturing high-speed signals from emergency shutdown valves and safety systems.
Process Automation: Logging on/off states of pumps, valves, and motor starters with precise timestamping.
Infrastructure: Integrating into traffic control or building management systems for fault analysis.
Batch Processing: Recording discrete events in chemical and pharmaceutical production for traceability.
Advanced Diagnostics
Integrated short-circuit and open-circuit detection on each channel reduces commissioning time and simplifies maintenance.
High-Resolution Event Logging
SOE with 2 ms resolution enables accurate sequence analysis for root-cause investigations.
Fast Signal Response
1 ms response time supports time-critical control and safety interlocks.
Robust Isolation
Optical barriers on each channel ensure immunity to electrical noise and prevent ground loops.
Compact & Lightweight
Slim 45 mm profile and 0.15 kg weight maximize cabinet space and ease installation.
ABB
S800 I/O
Model Number | Description | Channels | SOE Support | Weight | Notes |
---|---|---|---|---|---|
DI810 (3BSE008508R1) | Digital Input Module | 8 | No | 0.15 kg | Basic 8-channel input |
DI820 (3BSE008512R1) | Digital Input Module | 16 | No | 0.15 kg | Standard 16-channel input |
DI840 (3BSE020836R1) | Digital Input Module | 16 | Yes (1 ms) | 0.15 kg | SOE at 1 ms resolution |
DI880 (3BSE028586R1) | Digital Input Module | 16 | Yes (2 ms) | 0.15 kg | Short/open-circuit diagnostics |
DI825 (3BSE036373R1) | Digital Input Terminal Unit | 32 | No | 0.14 kg | High-density terminal module |
Model Number | Description | Key Parameters | Weight |
---|---|---|---|
AI810 (3BSE018501R1) | Analog Input Module | 8 × 4–20 mA | 0.20 kg |
AO810 (3BSE018503R1) | Analog Output Module | 8 × 0–10 V | 0.22 kg |
DO820 (3BSE008516R1) | Digital Output Module | 16 × relay outputs | 0.20 kg |
PM864 (3BSE018161R1) | AC 800M Controller | High-performance CPU | 0.60 kg |
IM818 (3BSE030263R1) | Interface Module | 1 × Profibus DP port | 0.25 kg |
Q1: What diagnostic features does the DI880 provide?
A1: It offers per-channel short-circuit and open-circuit detection for rapid fault isolation.
Q2: What is the SOE timestamp resolution?
A2: The module logs events with 2 ms timestamp accuracy.
Q3: How quickly does the module respond to input changes?
A3: Response time is 1 ms or less.
Q4: What voltage range must the inputs operate within?
A4: Inputs accept 20–30 V DC signals.
Q5: Can the DI880 be used in safety applications?
A5: Yes, its fast response and diagnostics support safety-related interlocks when paired with appropriate controllers.
Q6: How is the module mounted?
A6: It snaps onto a standard 35 mm DIN rail.
Q7: What is the weight and size of the DI880?
A7: The module measures 45 × 102 × 119 mm and weighs 0.15 kg.
Q8: Does the DI880 require external resistors?
A8: No, each channel includes built-in current limiting resistors.
Q9: What communication system does it use?
A9: It connects via ABB’s S800 I/O backplane.
Q10: How does the DI880 improve troubleshooting?
A10: On-board diagnostics and SOE logs with timestamps make fault analysis faster and more accurate.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.