Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The ABB Bailey NKST01 INFI 90 SOE Time Synchronization Cable is a specialized cable assembly used in ABB Bailey INFI 90 distributed control systems to support time synchronization connections for Sequence of Events (SOE) applications.
In industrial process control systems, SOE functions are used to capture the exact order and timing of digital events, including equipment trips, alarm changes, protection actions, and process status transitions. Accurate time synchronization is essential when multiple system points generate events simultaneously or when engineers need to analyze the sequence of operations after an abnormal condition.
The NKST01 provides the physical connection required for transferring synchronization signals between compatible INFI 90 system components. Unlike SOE modules or controllers that process event information, the cable itself does not perform timestamp calculation or system synchronization logic. Its role is to maintain the signal path between time synchronization hardware and related control system equipment.
For engineers maintaining ABB Bailey INFI 90 installations, the NKST01 may be inspected during SOE timing issues, event record inconsistencies, system upgrades, or cable replacement projects. Troubleshooting should include synchronization modules, connected devices, cable routing, connectors, and system configuration.
| Parameter | Specification |
|---|---|
| Manufacturer | ABB Bailey |
| Model | NKST01 |
| Product Family | INFI 90 |
| Product Type | SOE Time Synchronization Cable |
| Main Function | SOE synchronization signal connection |
| System Role | Communication / Timing Interface Component |
| Application | Distributed Control System (DCS) |
| Cable Length | Optional |
| Shipping Weight | 3 kg |
The ABB Bailey NKST01 INFI 90 SOE Time Synchronization Cable supports timing-related connection requirements in INFI 90 event monitoring systems.
Key characteristics include:
The cable should be selected according to the installed synchronization hardware, system layout, and connection requirements.
The NKST01 functions as the physical transmission path for synchronization signals within an INFI 90 SOE system.
A typical connection path can be represented as:
Time Synchronization Source → NKST01 Cable → SOE System Hardware → Event Recording Function
During operation, synchronization signals are transferred through the cable to connected SOE-related components. These signals allow the control system hardware to maintain consistent timing references when recording digital events.
The cable itself does not generate time information or process event records. Its practical role is focused on:
The actual timing management and event processing are performed by the associated INFI 90 system modules.
The ABB Bailey NKST01 operates within the SOE timing synchronization layer of an INFI 90 distributed control system.
A simplified architecture can be viewed as:
Synchronization Source → NKST01 Cable → SOE Input Hardware → INFI 90 Control System → Event Records
SOE systems are widely used in applications where the exact order of equipment actions needs to be reviewed. For example, after a plant shutdown or equipment trip, engineers may analyze recorded events to determine which condition occurred first.
The NKST01 supports this process by maintaining the connection required for synchronization signals to reach the appropriate SOE system components.
The ABB Bailey NKST01 INFI 90 SOE Time Synchronization Cable is used in industrial facilities where accurate event timing is required.
| Application | Typical Use |
|---|---|
| Power Generation | Supporting SOE event sequence analysis |
| Process Plants | Maintaining synchronized event records |
| Oil and Gas Facilities | Supporting operational event monitoring |
| Chemical Processing | Connecting timing-related DCS hardware |
| Utility Systems | Maintaining control system time coordination |
| Industrial Automation | Supporting legacy INFI 90 installations |
| Critical Process Systems | Improving event investigation capability |
The final application depends on the installed INFI 90 architecture and SOE configuration.
Installation of the NKST01 requires confirmation of the correct synchronization connection points and system arrangement.
Recommended maintenance procedures include:
When SOE event timing becomes inaccurate, engineers should inspect the complete synchronization path rather than assuming the cable is the only possible cause.
The NKST01 works together with several ABB Bailey INFI 90 system components.
| Component | Function |
|---|---|
| INFI 90 SOE Modules | Capture and process digital events |
| Time Synchronization Hardware | Provides timing reference signals |
| INFI 90 Controller Modules | Execute control strategies |
| Communication Modules | Exchange system information |
| Field Contact Devices | Generate event signals |
| Operator Interface Systems | Display alarms and event history |
| Engineering Workstations | Configure system parameters |
These components operate together to maintain accurate event monitoring within the DCS environment.
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| ABB Bailey NKST01 | INFI 90 SOE Time Synchronization Cable | Timing signal connection |
| ABB Bailey NKSD01 Series | INFI 90 SOE Digital Input Cable | SOE module connection |
| ABB Bailey NKSE01 Series | INFI 90 Serial Extension Cable | Serial communication extension |
| ABB Bailey NKPL01 | INFI 90 Twinax Plant Loop Cable | Plant loop communication |
| ABB Bailey INFI 90 SOE Components | Event Monitoring Hardware | Sequence of events applications |
Selection should be based on the existing INFI 90 SOE architecture, connected modules, and required cable function.
Time synchronization allows multiple digital events from different system points to be recorded with consistent timing information, which helps engineers analyze equipment actions and abnormal conditions.
A damaged or disconnected cable may affect synchronization signals, causing inaccurate event timing or inconsistencies in SOE records.
No. The NKST01 is a passive cable assembly. Timing generation and event processing functions are performed by the connected INFI 90 system hardware.
Engineers should confirm the cable model, connection location, synchronization hardware compatibility, and final SOE event timing performance after installation.