Product Overview The Siemens 6AG2155-5AA01-4AB0 SIPLUS ET 200MP IM155-5 PN ST Interface Module is a PROFINET communication interface designed for distributed I/O applications within the SIMATIC ET 200MP……
Siemens 6AG2155-5AA01-4AB0 SIPLUS ET200MP IM155-5 PN ST Interface Module
  • Siemens
  • 6AG2155-5AA01-4AB0
  • SIPLUS ET200MP IM155-5 PN ST Interface Module
  • Germany
  • 35 × 147 × 129 mm
  • 0.312 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Siemens 6AG2155-5AA01-4AB0 SIPLUS ET200MP IM155-5 PN ST Interface Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Siemens 6AG2155-5AA01-4AB0 SIPLUS ET200MP IM155-5 PN ST Interface Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Siemens 6AG2155-5AA01-4AB0 SIPLUS ET200MP IM155-5 PN ST Interface Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Siemens 6AG2155-5AA01-4AB0 SIPLUS ET200MP IM155-5 PN ST Interface Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Siemens 6AG2155-5AA01-4AB0 SIPLUS ET 200MP IM155-5 PN ST Interface Module is a PROFINET communication interface designed for distributed I/O applications within the SIMATIC ET 200MP automation system. It connects ET 200MP electronic modules to a PROFINET IO controller, enabling a central PLC to exchange process data with remotely installed input and output modules.

This model belongs to the Siemens SIPLUS product range. It is based on the standard SIMATIC interface module 6ES7155-5AA01-0AB0 and incorporates additional environmental protection features, including conformal coating. Its specified operating temperature range is -40 to +70 °C, making it suitable for installations exposed to wider temperature variations than conventional indoor control environments.

The IM155-5 PN ST acts as the communication head of an ET 200MP station. It manages data exchange between the PROFINET network and the connected I/O modules. This arrangement allows sensors, actuators, measurement devices, and other field equipment to communicate with a central automation controller without requiring every signal to be wired directly to the main PLC cabinet.

The interface module supports an integrated two-port Ethernet switch, allowing PROFINET devices to be connected in a line topology. It also supports functions such as Shared Device, Media Redundancy Protocol (MRP), isochronous operation, and identification and maintenance data. These features provide flexibility for automation engineers designing distributed control architectures.

The module can support up to 12 I/O modules without an additional power supply module and up to 30 I/O modules when an additional power supply is installed, subject to the system configuration and applicable Siemens engineering requirements.

With its compact design, rail-mounted installation, PROFINET connectivity, and SIPLUS environmental protection, the 6AG2155-5AA01-4AB0 is intended for distributed automation installations where reliable communication and environmental resilience are important.

Technical Specifications

Parameter Specification
Brand Siemens
Product Series SIPLUS ET 200MP
Model 6AG2155-5AA01-4AB0
Product Name IM155-5 PN ST TX RAIL
Product Type PROFINET Interface Module
System SIMATIC ET 200MP
Base Model 6ES7155-5AA01-0AB0
Communication Protocol PROFINET IO
Interface Integrated 2-port Ethernet switch
Ethernet Connection RJ45
Supply Voltage 24 V DC
Maximum I/O Modules Without Additional Power Supply 12
Maximum I/O Modules With Additional Power Supply 30
Shared Device Supported
Media Redundancy Protocol (MRP) Supported
Isochronous Mode Supported
Identification and Maintenance Data I&M0 to I&M3
Environmental Protection Conformal coating
Operating Temperature -40 to +70 °C
Short-Term Temperature Capability Up to +85 °C for 10 minutes under specified conditions
Mounting Type Rail-mounted
Dimensions Provided 35 × 147 × 129 mm
Weight 0.312 kg
Typical Application Distributed I/O and industrial PROFINET networks

Note: Temperature limits and short-term operating conditions must be interpreted according to the manufacturer’s installation and environmental specifications. The supplied dimensions are retained as listing values.

Function and Working Principle

The primary function of the 6AG2155-5AA01-4AB0 is to connect an ET 200MP distributed I/O station to a PROFINET industrial network. It manages communication between the connected electronic modules and the central controller.

1. PROFINET Communication

PROFINET is an Industrial Ethernet communication standard used to exchange real-time process data between PLCs, distributed I/O stations, drives, and other automation devices.

The IM155-5 PN ST operates as a PROFINET IO device. It communicates with a configured PROFINET IO controller, typically a SIMATIC S7-1500 PLC or another compatible controller.

During normal operation, the controller exchanges input and output data with the distributed station. Input signals collected by the I/O modules are transferred to the controller, while output commands are delivered to the relevant output modules.

This communication structure allows control equipment to be installed closer to the machinery or process area, reducing the need for long individual signal cables running back to a central cabinet.

2. Distributed I/O Management

The ET 200MP system uses a modular architecture. The interface module forms the communication connection between the PROFINET network and the electronic I/O modules installed in the station.

Depending on the selected module arrangement, the station can accommodate digital input, digital output, analog input, analog output, and other supported ET 200MP modules.

The interface module coordinates the station’s communication and makes the process data available to the central controller.

Its capacity depends on the installed system configuration:

  • Up to 12 I/O modules without an additional power supply module.
  • Up to 30 I/O modules with an additional power supply module.

The actual configuration must comply with Siemens system rules, power requirements, and supported module combinations.

3. Integrated Two-Port Ethernet Switch

The integrated two-port switch allows network devices to be connected in a line topology.

In a typical arrangement, the PROFINET cable from the controller or previous network device connects to one port, while the second port connects to the next device. This can simplify network cabling in distributed installations.

A line topology can reduce the need for separate switch hardware at every station. However, network planning should still consider cable length, device count, network loading, fault isolation, and the overall topology requirements.

4. Media Redundancy Protocol

The module supports Media Redundancy Protocol (MRP), a PROFINET network function used in ring topologies.

In an appropriately configured network, MRP can help maintain communication when a single network connection is interrupted. The network devices and controller must be configured to support the required redundancy arrangement.

MRP is not an automatic substitute for network engineering. The topology, participating devices, and redundancy settings must be planned and tested as part of the complete automation system.

5. Isochronous Operation

The IM155-5 PN ST supports isochronous mode. This function is relevant to applications where synchronized communication and predictable timing are important.

Isochronous communication can help coordinate distributed I/O data with the controller’s control cycle. It is useful in applications that require consistent timing between control processing and field-level data acquisition.

The achievable cycle performance depends on the complete PROFINET system, controller, network configuration, and connected devices.

6. Identification and Maintenance Data

The module supports I&M0 to I&M3 identification and maintenance data.

This information helps engineering and maintenance personnel identify installed hardware and manage device-related information during commissioning, troubleshooting, and equipment replacement.

Accurate identification data can simplify maintenance activities in systems containing multiple distributed I/O stations.

Role in Industrial Control Systems

The 6AG2155-5AA01-4AB0 functions as a communication interface within a distributed automation architecture. It connects field-level I/O modules to the PROFINET network and provides a communication path between local signals and the central controller.

PLC Communication

A PLC executes the control program and processes information received from the distributed I/O stations.

The interface module transfers input and output data between the ET 200MP station and the PROFINET IO controller. For example, a PLC may receive signals from temperature sensors, pressure transmitters, limit switches, and proximity sensors installed around a machine.

The PLC processes these signals and sends commands to output modules that control valves, contactors, indicator lights, and other field devices.

Distributed Signal Acquisition

In a large manufacturing facility, field devices may be located far from the main control cabinet. Installing ET 200MP stations near the equipment allows signal collection to be distributed across different areas.

The interface module provides the communication connection for each station, while the individual I/O modules handle the electrical signal interfaces.

This architecture can simplify cabinet organization and reduce the amount of individual field wiring routed to a central PLC.

Integration With SIMATIC Engineering

The module is configured as part of the ET 200MP station in a compatible Siemens engineering environment.

During engineering, the station’s device configuration, I/O module arrangement, network settings, and controller assignment must be defined. The configuration must match the physical hardware installed in the control cabinet.

After commissioning, diagnostic information can help engineers identify communication problems, module faults, and configuration mismatches.

Industrial Network Coordination

The integrated two-port switch and supported MRP functions provide options for designing PROFINET networks.

A suitable network architecture can connect multiple distributed stations while maintaining a clear communication structure. The correct topology depends on the number of devices, cable routing, network redundancy requirements, and the control system’s performance needs.

Industrial Applications

The SIPLUS ET 200MP IM155-5 PN ST is suitable for distributed automation systems where PROFINET communication and extended environmental operating conditions are required.

1. Manufacturing Production Lines

Manufacturing lines often contain multiple machines, conveyors, sensors, and actuators distributed across a production area.

The interface module can connect local ET 200MP I/O stations to a central PLC. Each station collects signals from nearby equipment and exchanges process data over the PROFINET network.

This arrangement can simplify machine wiring and make the overall control architecture easier to organize.

2. Process Automation

Industrial process facilities use distributed sensors and actuators to monitor and regulate production conditions.

An ET 200MP station can collect signals from pressure transmitters, temperature sensors, flow instruments, and other field devices. The interface module transfers the data to the central control system.

The SIPLUS environmental design may be useful in installations exposed to wider temperature variations, provided the actual site conditions remain within the product’s specified limits.

3. Energy and Utility Facilities

Power generation facilities, utility installations, and infrastructure systems may use distributed I/O stations to monitor equipment located in different areas.

The 6AG2155-5AA01-4AB0 can provide the PROFINET connection for a local I/O station, supporting communication with a central automation controller.

The extended temperature range can be relevant to installations where control equipment experiences seasonal or operational temperature changes.

4. Transportation and Railway-Related Installations

SIPLUS products are designed for applications requiring enhanced environmental resistance. The 6AG2155-5AA01-4AB0 product configuration is associated with railway-related environmental requirements.

It may be considered for suitable railway and transportation automation installations where the applicable system approvals, installation rules, and environmental requirements are met.

The use of this module in a particular transportation system must be confirmed against the project’s required standards and certification documentation.

5. Outdoor and Harsh-Environment Control Cabinets

Some automation cabinets are installed in areas where ambient temperatures vary considerably or where electronic assemblies may be exposed to challenging environmental conditions.

The conformal coating and specified operating temperature range provide additional protection compared with a standard indoor-oriented configuration.

Nevertheless, the module must still be installed in a suitable enclosure. Conformal coating does not make the product waterproof or suitable for direct exposure to every corrosive or contaminated environment.

6. Large Distributed Control Systems

Facilities with multiple production areas may use several ET 200MP stations connected through a PROFINET network.

The interface module provides communication for an individual station, allowing I/O to be distributed according to the plant layout.

This can be useful in automotive production, machinery manufacturing, packaging facilities, and other installations where control signals are spread across a large operating area.

Installation and System Integration

Proper installation and configuration are essential for stable communication and reliable operation.

1. Verify the Product Model

Before installation, confirm that the module is Siemens 6AG2155-5AA01-4AB0.

This model is based on the standard 6ES7155-5AA01-0AB0 interface module but belongs to the SIPLUS range and includes conformal coating and an extended temperature specification.

Do not treat the SIPLUS and standard versions as interchangeable without checking the project requirements and hardware configuration.

2. Confirm the Power Supply

The interface module uses a 24 V DC supply.

Verify that the power supply provides the correct voltage and sufficient current capacity for the complete station. Consider the power requirements of the interface module and all connected I/O modules.

The additional power supply arrangement may also affect the maximum supported number of I/O modules.

3. Install the Module on the Rail

Mount the interface module in the designated ET 200MP rail arrangement and follow the manufacturer’s mechanical installation instructions.

Ensure that the module is properly seated and that all relevant connections are secure.

Allow sufficient cabinet space for wiring access, ventilation, and maintenance. Avoid mechanical stress on the module and connected cables.

4. Connect the PROFINET Network

Connect the module to the PROFINET network using the integrated RJ45 ports.

Check the cable condition, connector installation, and network topology. In line topology installations, verify the connection path between the controller, interface module, and subsequent network devices.

For MRP ring configurations, confirm that the participating devices and controller support the selected redundancy arrangement.

5. Configure the ET 200MP Station

Use a compatible Siemens engineering environment to configure the interface module and connected I/O modules.

Typical engineering activities include:

  • Adding the correct interface module to the hardware configuration.
  • Selecting the connected ET 200MP I/O modules.
  • Assigning the PROFINET device name.
  • Configuring the IP address and network settings.
  • Defining the input and output addresses.
  • Setting up any required MRP or isochronous functions.
  • Checking the controller and device configuration.

The physical module arrangement must match the engineering configuration. Incorrect device names, module selections, or address assignments may prevent the station from operating correctly.

6. Commission and Test Communication

After installation, verify the 24 V DC supply, network connections, and module status indicators.

Check whether the PROFINET IO controller recognizes the station and whether the configured I/O data is exchanged correctly.

Test input and output signals individually where possible. Confirm that diagnostic messages are clear and that the station behaves correctly during normal operation and expected network fault conditions.

7. Environmental Considerations

The specified operating temperature range is -40 to +70 °C, with short-term temperature capability up to +85 °C for 10 minutes under defined conditions.

The module should be installed within the environmental limits specified by Siemens. Maintain appropriate cabinet protection, electrical grounding, ventilation, and contamination control.

The conformal coating provides additional protection for electronic assemblies but does not remove the need for proper enclosure design and maintenance.

Compatible System Components

The 6AG2155-5AA01-4AB0 is designed to operate as part of a SIMATIC ET 200MP distributed I/O station.

Component Function Integration Considerations
SIMATIC S7-1500 PLC PROFINET IO controller Confirm controller compatibility and device configuration
ET 200MP digital input modules Collect discrete field signals Check module type, channel count, and electrical ratings
ET 200MP digital output modules Control discrete field devices Verify output type, load rating, and supply requirements
ET 200MP analog input modules Acquire analog measurement signals Match signal type and measurement range
ET 200MP analog output modules Provide analog control signals Confirm output range and connected equipment requirements
ET 200MP power supply modules Provide additional station power Required when the station configuration exceeds the applicable power limits
PROFINET Ethernet cables Connect the station to the industrial network Use suitable industrial Ethernet cabling and connectors
Industrial Ethernet switches Connect network devices Select according to topology and redundancy requirements
24 V DC power supply Supplies the interface and station electronics Verify voltage, current capacity, and protection
DIN rail or system rail Provides mechanical mounting Follow the ET 200MP mounting arrangement

Actual compatibility depends on the hardware version, firmware, engineering software, and system configuration. Confirm the approved module combinations before assembling the station.

Alternative Models and Replacement Considerations

The 6AG2155-5AA01-4AB0 is a SIPLUS version based on the standard 6ES7155-5AA01-0AB0 interface module.

When selecting a replacement, it is important to distinguish between standard ET 200MP hardware and SIPLUS hardware designed for extended environmental conditions.

Alternative Model Product Type Replacement Considerations
Siemens 6ES7155-5AA01-0AB0 Standard ET 200MP IM155-5 PN ST Functional base model, but environmental protection and temperature specifications differ
Siemens 6ES7155-5AA00-0AB0 ET 200MP PROFINET interface module Different configuration; verify I/O capacity and supported functions
Siemens 6ES7155-5AA00-0AC0 ET 200MP IM155-5 PN HF Higher-feature interface option; verify the required functionality and hardware compatibility
Siemens 6AG2155-5AA00-1AC0 SIPLUS ET 200MP IM155-5 PN HF T1 SIPLUS alternative with a different interface feature set and temperature specification
Siemens 6AG1155-5AA00-2AC0 SIPLUS ET 200MP IM155-5 PN HF Another SIPLUS interface option; verify mounting, system configuration, and environmental requirements

Before replacing the module, compare:

  • Complete order number and product version.
  • PROFINET interface functionality.
  • Supported I/O module count.
  • Required 24 V DC supply arrangement.
  • Firmware and engineering software compatibility.
  • Network topology and redundancy requirements.
  • Isochronous operation requirements.
  • Environmental temperature range.
  • Conformal coating and environmental protection.
  • Mechanical dimensions and mounting arrangement.

A standard interface module may provide similar basic communication functions but may not offer the same environmental protection as the SIPLUS version. For installations exposed to extreme temperatures, this distinction is especially important.

Key Advantages

Extended Operating Temperature Range

The specified -40 to +70 °C operating range supports installations exposed to wider temperature variations than many conventional control cabinet environments.

Conformal Coating

The SIPLUS configuration includes conformal coating, providing additional protection for electronic assemblies under suitable environmental conditions.

PROFINET Communication

The module provides a PROFINET IO connection between the ET 200MP distributed I/O station and the central controller.

Integrated Two-Port Switch

The integrated Ethernet switch supports line topology arrangements and can simplify network cabling in distributed installations.

Flexible I/O Expansion

The station supports up to 12 I/O modules without an additional power supply module and up to 30 with an additional power supply, subject to system configuration requirements.

Network Redundancy Support

MRP support provides an option for ring-based network redundancy when the complete network is configured with compatible devices.

Isochronous Operation

Support for isochronous mode makes the interface suitable for automation systems requiring synchronized communication.

Maintenance Information

I&M0 to I&M3 support helps identify the installed module and manage maintenance-related information.

Technical FAQs

1. What is the Siemens 6AG2155-5AA01-4AB0?

It is a SIPLUS ET 200MP IM155-5 PN ST PROFINET interface module. It connects ET 200MP distributed I/O modules to a PROFINET IO controller in an industrial automation system.

2. What is the difference between 6AG2155-5AA01-4AB0 and 6ES7155-5AA01-0AB0?

The 6AG2155-5AA01-4AB0 is the SIPLUS version based on the standard 6ES7155-5AA01-0AB0. The SIPLUS version includes conformal coating and an extended operating temperature range of -40 to +70 °C.

3. What communication protocol does this module use?

It uses PROFINET IO to exchange process data between the ET 200MP station and the configured PROFINET IO controller.

4. How many I/O modules can be connected?

The station can support up to 12 I/O modules without an additional power supply module and up to 30 I/O modules with an additional power supply, subject to the manufacturer’s system configuration requirements.

5. What power supply does the interface module require?

The module uses a 24 V DC supply. The complete station’s power requirements should be calculated according to the installed interface and I/O modules.

6. Does the module have an integrated Ethernet switch?

Yes. It has an integrated two-port Ethernet switch with RJ45 connections, allowing suitable PROFINET devices to be connected in a line topology.

7. Does it support MRP?

Yes. The module supports Media Redundancy Protocol. The complete ring network must be designed and configured with compatible devices and a suitable PROFINET controller.

8. What is the operating temperature range?

The specified operating temperature range is -40 to +70 °C. A short-term capability of up to +85 °C for 10 minutes is specified under defined conditions.

9. Can this module be used with an S7-1500 PLC?

It is designed for PROFINET IO communication and can be used in a suitable system with a compatible PROFINET IO controller, including appropriately configured SIMATIC S7-1500 controllers. Confirm the engineering software, firmware, and hardware compatibility for the specific project.

10. Is the 6AG2155-5AA01-4AB0 suitable for harsh environments?

It is designed for extended environmental conditions compared with the standard base model. Its SIPLUS design, conformal coating, and -40 to +70 °C operating range support suitable installations with wider temperature variations. It must still be installed within the manufacturer’s environmental and electrical limits.

Procurement and Maintenance Recommendations

When purchasing the Siemens 6AG2155-5AA01-4AB0, verify the complete order number and ensure that the supplied unit is the SIPLUS ET 200MP IM155-5 PN ST TX RAIL version. The standard 6ES7155-5AA01-0AB0 and the SIPLUS version have related functions but different environmental specifications.

For replacement projects, compare the original module’s order number, hardware version, firmware requirements, PROFINET configuration, and environmental operating conditions. Confirm that the replacement supports the installed ET 200MP I/O modules and the required network functions.

When sourcing new, surplus, or refurbished units, inspect the housing, connectors, rail mounting features, and terminal condition. Check for signs of physical damage, contamination, or improper storage. Confirm whether the product is supplied with its original packaging and request appropriate product identification information.

During routine maintenance, inspect the PROFINET cables, RJ45 connectors, power supply connections, and module status indicators. Keep the control cabinet clean and ensure that the installation remains within the specified temperature and environmental limits.

It is also advisable to maintain an updated hardware configuration and backup of the PLC engineering project. Recording the module order number, device name, IP address, I/O configuration, and firmware information can make future troubleshooting and replacement work more efficient.

Conclusion

The Siemens 6AG2155-5AA01-4AB0 SIPLUS ET 200MP IM155-5 PN ST is a PROFINET interface module designed for distributed I/O communication in industrial automation systems. Based on the standard 6ES7155-5AA01-0AB0, it adds SIPLUS environmental protection features, including conformal coating and an extended operating temperature range of -40 to +70 °C.

With an integrated two-port Ethernet switch, MRP support, isochronous operation, and flexible ET 200MP I/O expansion, the module provides a communication interface for distributed control architectures.

For industrial procurement, installation, and maintenance, checking the complete order number and environmental requirements is essential. Selecting the correct SIPLUS configuration helps ensure that the interface module meets the communication and operating conditions of the intended automation system.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501