The 330180-X2-05 (MOD 163358-02) is a high-sensitivity eddy current proximity transducer system designed for precise, continuous, non-contact measurement of shaft vibration and displacement in rotating machinery.
It is used in industrial condition monitoring systems where short-range, high-resolution measurement is required to ensure stable mechanical operation and early fault detection.
The system converts variations in the electromagnetic field between the probe tip and a conductive metal target into a proportional analog voltage signal, enabling micrometer-level displacement monitoring.
(Company name intentionally omitted as requested)
This series is widely used in heavy industrial applications due to its stability, durability, and high measurement accuracy.
The 330180-X2-05 (MOD 163358-02) is applied in multiple industrial environments, including:
| Parameter | Specification |
|---|---|
| Operating voltage | 24 V DC |
| Output signal | Analog linear voltage |
| Measurement principle | Eddy current induction |
| Output impedance | 50–100 Ω |
| Frequency response | Up to 10 kHz |
| Signal stability | High long-term stability |
| Parameter | Specification |
|---|---|
| Measurement range | 0 – 2 mm (short-range high sensitivity) |
| Resolution | ≤ 1 μm |
| Accuracy | ±0.25% – ±0.5% FS |
| Linearity | High linear response within calibrated range |
| Repeatability | Excellent stability under continuous operation |
| Parameter | Specification |
|---|---|
| Operating temperature | -40°C to +121°C |
| Storage temperature | -55°C to +125°C |
| Humidity | 5% – 95% non-condensing |
| Vibration resistance | Up to 20 g depending on installation |
| EMI protection | Strong electromagnetic shielding |
| Parameter | Specification |
|---|---|
| Signal conditioner dimensions | 100 mm × 160 mm × 50 mm |
| Probe material | Stainless steel housing |
| Cable type | Shielded coaxial cable |
| Cable length options | 3 m / 5 m / 9 m |
| Total system weight | ~2.0 kg |
| Probe weight | ~0.08 kg |
| Mounting type | Panel / rack installation |
The system operates based on eddy current electromagnetic induction:
This enables accurate non-contact measurement of very small displacement variations in rotating machinery.
| Parameter | 330180-X2-05 163358-02 | 330180-X2-00 | 330180-X2-05 163358-11 | 330180-X2-05 163358-19 | 330180-X2-05 163358-33 |
|---|---|---|---|---|---|
| Measurement type | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 0–2 mm | 0–5 mm | 0–2 mm | 0–2 mm | 0–2 mm |
| Accuracy | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS |
| Dimensions | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm | 100×160×50 mm |
| Weight (kg) | 2.0 kg | 2.0 kg | 2.0 kg | 2.0 kg | 2.0 kg |
| Parameter | 330780-100-00 | 330881-28-19-180-02-02 | 330103-00-15-10-02-00 | 330106-05-80-10-02-00 | 330104-00-15-10-02-00 |
|---|---|---|---|---|---|
| System type | Proximity probe | Signal module | Proximity probe | Proximity probe | Proximity probe |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency range | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 2–5 mm | 2–5 mm | 2–5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 90×140×40 mm | 110×170×55 mm | 85×130×35 mm | 85×130×35 mm | 85×130×35 mm |
| Weight (kg) | 1.6 kg | 2.3 kg | 1.2 kg | 1.2 kg | 1.2 kg |
| Parameter | 330901-00-22-10-02-05 | 330905-00-21-10-02-00 | 330909-00-70-10-02-05 | 330910-00-21-10-02-00 | 330930-00-14-10-02-00 |
|---|---|---|---|---|---|
| Product type | Proximity probe | Signal conditioner | High sensitivity probe | Vibration probe | Industrial probe unit |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 7 mm | 5 mm | 5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.25% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 95×150×45 mm | 120×180×60 mm | 100×160×50 mm | 95×150×45 mm | 90×140×40 mm |
| Weight (kg) | 1.8 kg | 2.5 kg | 2.1 kg | 1.7 kg | 1.5 kg |
The 330180-X2-05 (MOD 163358-02) is a high-sensitivity eddy current proximity transducer system designed for short-range precision displacement measurement. It provides excellent resolution, stable performance, and strong environmental resistance, making it suitable for critical rotating machinery monitoring applications.